2020 AR 01 500 Old Greenville Hwy February Submittal
2020 AR 01 500 Old Greenville Hwy February Submittal
dwg(A-1) 1\15\20-10:08am(cpolanski)
SERVING
DINING ROOM KITCHEN
CUSTOMER
PICK-UP
COOLER
OFFICE
STOCK
FREEZER
FLOOR PLAN
SCALE: 1/4" = 1'-0"
BURGER KING
500 OLD GREENVILLE HWY
CLEMSON, S. CAROLINA 29631
CARROLS, LLC
SYRACUSE, NEW YORK
FLOOR PLAN
& MISC. DETAILS
TYPICAL INTERIOR PARTITION
3 SCALE: NOT TO SCALE
.
SSUE
1/9/20
JAMES W. MANGUSO
ARCHITECT
J A M E S W. M A N G U S O
ARCHITECT
4080 Ridge Lea Road
B u f f a l o, N. Y. 1 4 2 2 8
(716) 837 - 0833
PLAN DETAIL
PLAN DETAIL 2 Date: 12/10/2019 Drawing No.
1 SCALE: 1 1/2" = 1'-0"
A-1
SCALE: 1 1/2" = 1'-0" D r a w n By : CJP
C h e c k e d By: JWM
Job Number: 19057
J:\2019 jobs\19057 BK CLEMSON SC\Drawings\14 A-3 Building sections.dwg(A-3P) 1\15\20-1:54pm(cpolanski)
DINING ROOM
GAYLORD
KITCHEN
BUILDING SECTION
1
BURGER KING
500 OLD GREENVILLE HWY
CLEMSON, S. CAROLINA 29631
CARROLS, LLC
SYRACUSE, NEW YORK
BUILDING
CROSS SECTIONS
BUILDING SECTION
2
.
SSUE
1/9/20
JAMES W. MANGUSO
ARCHITECT
J A M E S W. M A N G U S O
ARCHITECT
4080 Ridge Lea Road
B u f f a l o, N. Y. 1 4 2 2 8
(716) 837 - 0833
A-3P
SITE CROSS SECTION D r a w n By : CJP
3 C h e c k e d By: JWM
Job Number: 19057
SECURITY
LIGHTING™ RWSC
LED RADIUS WALL SCONCE
The RWSC LED radius wall sconce series offers a combination of light
distributions that wash the building facade while the radial soft form housing
accentuates building architectural design elements in all commercial and
residential applications.
The RWSC LED provides excellent illumination with a high efficiency LED
light source of 72 or 36 mid power LEDS that deliver up to 2,400 lumens and
up to 109 lumens per watt.
The RWSC LED fixture has become a building standard and is stocked as a
quick ship item in many colors and distributions.
Features
• Durable cast aluminum housing
• Integrated design eliminates high angle brightness
• Completely sealed, flat tempered glass lenses, UL listed for use in wet
locations
• DLC, Downlight only, full cut-off
Operating Temperature
• -30°C to 40°C Dimensions
Electrical:
• Dimming is an option (consult factory) B C
Mounting
RWSC features Intelligent Mounting Bracket which helps save time and
A
money by allowing only one person to easily install. The small mounting
bracket is very user friendly and features an integrated level bubble on the
bracket ensuring fixture installation will always be perfect.
A B C
Certifications/Listings 7.25" 18.0" 9.0"
4.2
RWSC DO
RWSC Radius Wall 36L1 36 Mid-Power LED's 3K 3000K DO Down only U Universal 120/277V DB Dark Bronze PC Photocontrol6,7
Sconce
72L2 72 Mid-Power LED's 5K 5000K UD Up/Down WH White
BK Black
PS Platinum Silver
Quick Ship:
RA RAL Color4
RWSC36LU5KDOBK
CC Custom Color5
1 RWSC36LU5KDOWH
36L Only available in DO distribution
2
72L Only available in UD distribution RWSC36LU5KDODB
3
One remote inverter required to operate every 8 down only or 5
RWSC36LU5KDOPS Accessories
up/down fixtures requiring EM operation
4
Must provide RAL color at time of ordering RWSC72L5KUDUWH LG125T Remote Emergency Inverter (grid
5
Must provide color sample at time of ordering mount only)3
RWSC72LU5KUDBK
6
PC must be factory installed LG125S Remote Emergency Inverter
7
PC available on down only RWSC72LU5KUDDB (surface mount only)3
RWSC72LU5KUDPS
Web: www.securitylighting.com
2100 Golf Road, Suite 460, Rolling Meadows, IL 60008-4704
Phone: 1-800-LIGHT IT, 1-800-544-4848, Fax: 847-279-0642
Copyright ©2016 Security Lighting, a division of Hubbell Lighting, Inc.
All Rights Reserved. • Specifications subject to change without notice. • Printed in U.S.A. • SLS0027 04/18
SECURITY
LIGHTING™ RWSC
LED RADIUS WALL SCONCE
Performance Data
5K 3K
(5000K nominal, 80 CRI) (3000K nominal, 80 CRI)
Drive Current
# of LEDS System Watts Distribution Type Lumens LPW1 B U G Lumens LPW1 B U G
(Milliamps)
36 350 14.4 down 1565 108.7 0 0 0 1561 109.1 0 0 0
72 350 25 up/down 2400 96 n/a n/a n/a 2391 97.6 n/a n/a n/a
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown.
1
Photometric Data
LUMINAIRE DATA ISOMETRIC FOOT CANDLES POLAR GRAPH
RWSC-36L-5K-DO-U-PS
Wall Mounting Outdoor Fixture 3
DRIVER LED30W-085-C0350
Lamp LED .1
141
2
Lumens 1565 .2
Watts 14.4
.5
Efficacy 109 281
1 1
Mounting Wall 2
Spacing Criterion (0-180) 1.20
5 422
0
ZONE LUMENS % FIXT.
1
Front Low (0-30) 218.6 14.0
562
Front Medium (30-60) 424.2 27.1 1
Front High (60-80) 135.5 8.7 Maximum Candela = 562 Located At Horizontal Angle = 0, Vertical Angle = 0
# 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.)
Front Very High (80-90) 4.2 0.3 # 2 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.)
Back Low (0-30) 218.6 14.0 1.75
2
Back Medium (30-60) 424.2 27.1
Back High (60-80) 135.5 8.7
Back Very High (80-90) 4.2 0.3 2.75
Uplight Low (90-100) 0.0 0.0 3
4
0 1 2 2.25 3 3.75 4
IES ROAD REPORT
Distance In Units Of Mounting Height IES ROAD REPORT
PHOTOMETRIC FILENAME : RWSC-72L-5K-UD-U-PS.IES
Values Based On 10 Foot Mounting Height PHOTOMETRIC FILENAME : RWSC-72L-5K-UD-U-PS.IES
Efficacy 96 1 1
Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc. Page 5
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
LIGHTBAND
BK 2020
LED IMAGE LIGHTING
1016
I N S T A L L AT I O N G U I D E
918.622.4978
www.lektroninc.com
sales@lektroninc.com
GETTING STARTED CONTENTS
Following these few simple steps will ensure a successful Getting Started, Component Identification & Required Tools
installation each time. Remember: No more than 32 boards per
power supply. SECTION PAGE
1. Read ALL instructions, before starting installation.
2. Inspect the boxes for damage and check the parts against 1. Component Identification & Required Tools......................... 2
the supplied parts list.
2. Proper Measuring & Placement of the Lightband................. 3
NOTE: Report damaged parts or shortages immediately to
prevent job slowdown/stoppage to 1-800-634-4059 ext. 0 3. Installation of Cut Sections & Sizing the LED Band.............. 4
3. Refer to attached provided print and confirm job
measurements. 4. Setting the Power Supply........................................................ 5
4. Layout your job on paper, making note of power supply
5. Testing Each Section................................................................ 6
placement.
Power supplies can be placed at the end of runs or side by side 6. Lens Installation........................................................................ 7
to power allowable linear footage in each direction.
NOTE: If job measurements do not correspond to provided 7. End Cap Installation................................................................. 8
drawing, call Lektron Immediately at 1-800-634-4059.
INSTALLATION SEQUENCE
Page 1
C O M P O N E N T I D E N T I F I C AT I O N
SEC. 1 & REQUIRED TOOLS
Die-stamped
Aluminum
2.50 Housing
Prefinished
#12 x 2” .75
HEX HEAD
191-7011 SCREW
ALUMINUM 16 Ga.
HOUSING Galvinized
8’ LENGTH
185-7022 #10 x 3/4” Steel
FLAT RED POLYCARBONATE LENS HEX HEAD
CONTINUOUS LENGTH SCREW Red Lens
SEAL TIGHT
CONDUIT
185-0017
185-2006
25V LOW VOLTAGE
16 Ga.
J-BOX TRANSFORMER Galvinized
185-0007 Steel
PLTC 15.00 13.38
CABLE
Aluminum
#8 x 1/2”
LEFT PAN 191-1136 191-2040 Housing
END
CAP
HEAD 3” 5L RED BOARD
TRACK
CLIP Prefinished
SCREW
BK Silver
#6 x 1/2”
RIGHT
PAN
12” 20 LAMP RED MAIN BOARD
END
HEAD
CAP
SCREW
O.S. 191-1025
CORNER O.S. CORNER
.88
HOUSING CAP
I.S. 191-1026
CORNER I.S. CORNER
HOUSING CAP
Page 2
PROPER MEASURING &
SEC. 2 PLACEMENT OF THE LIGHTBAND
1. Determine if your location is typical or high wind zone. 3. Install the first 8’ aluminum fixture housing by aligning to
2. Mark mounting bracket locations. Housings will share the edge of the mounting bracket and approximately 1/4”
a bracket. Set bracket 1/4” from the end of the run. from the end of the run. Insure that housing is plumb and
3. Install using a dab of caulk beneath each #12 x 2 level, shim if required. Fasten each with 5 #10 x 3/4” Hex
screw penetration as shown. Head tek screws, spaced approximately 2 in. apart,
through the mounting bracket.
2-#12 X 2” 4. Using four #10 x 3/4” tek screws, screw through housing
and the fixture coupling while holding the seam together,
put one screw into each fixture, joining the pieces together
securely.
5. Apply second bracket to the backside of the housing fixture
using a dot of caulk for each screw to waterproof. Secure
with two #10 x 3/4” tek screws.
TYPICAL
MOUNTING
48” 6. Slide brackets until the housing is plumb. Clamp the
adjustment bracket together and run two #10 x 3/4” tek
screws through the assembly to hold securely.
7. Repeat the process.
48” 32”
32” COUPLING 2 8ft SECTIONS
32”
HIGH WIND
MOUNTING IMPORTANT: DO NOT SKIP ANY STEPS IN THIS SECTION.
FIXTURES MAY BE LIFTED AND BLOWN OFF PRIOR TO ALL
ATTACHMENTS BEING SECURELY MADE.
1. Set corner housing onto 4 mounting brackets NOTE: Adjustment brackets should be mounted at equal
2. Attach corner to brackets with #10 x 3/4” tek screws. intervals, to the mounting brackets. The purpose of the
adjustment bracket is to keep the light band vertically
NOTE: BRACKETS ENLARGED TO SHOW DETAIL straight, as well as provide stability to the light band.
TIP: APPLY ALL BOTTOM BRACKETS FIRST, ALL TOP
BRACKETS NEXT AND THEN SECURE IN THE MIDDLE.
1. Measure and mark locations for the Adjustment Brackets,
install 1/2 of the Adjustment Bracket. Use two #12 x 2” tek
screws, applied through a dot of caulk.
Page 3
I N S T A L L AT I O N O F C U T S E C T I O N S
SEC. 3 & SIZING THE LED BAND
4. Additional adjustment brackets are needed for 3. Install full 1 foot boards until less than 1 foot of space
support. remains.
VERY IMPORTANT:
Insulate or remove unused wires at end of
run to prevent shorting. Do not connect
wires together or to next circuit.
Page 4
SETTING THE
SEC. 4 P O W E R S U P P LY
NOTE: Any primary voltage supply greater than 120, “STOP” call Lektron at 918-622-4978
1. Attach J-Boxes with supplied screws to available support member. TO J-BOX
2. Attach transformers inside of J-Boxes.
3. Drill 7/8” hole through the housing.
4. Install Liquid-Tight Connector for low voltage wire. Connect conduit.
5. Install low voltage wire into the conduit and connect to LED.
Side by Side mounting location shown below can reduce primary and secondary wiring labor time.
NOTE: One transformer per 32 boards maximum or less. No less than 8 boards per transformer
WIRE CONNECTIONS
Recognized 24Vac
Liquid-Tight Voltage Primary
Black & White wires = Primary
UL Class 2
voltage wires from
Connector
100va
power supplies. connection only by Electrician
Connect to low
voltage cable
(Non-Polarized)
Silicone
top of
J-Box 25 VAC Low !
A conduit fitting
Voltage
DO NOT CONNECT
installed so that conduit 120 VOLTS TO LEDs.
can be used. LEDs are 25Vac only
VERY IMPORTANT: KEEP LOW VOLTAGE CIRCUITS ELECTRICALLY SEPARATE, DO NOT CONNECT TRANSFORMERS
OR LEDs FROM DIFFERENT 32 BOARD CIRCUITS TOGETHER OR CONNECT MORE THAN 32 BOARDS TO A TRANSFORMER!
Page 6
LENS
SEC. 6 I N S T A L L AT I O N
FIGURE 1 FIGURE 2
Page 7
END CAP
SEC. 7 I N S T A L L AT I O N
1. Fasten the silver end cap to the top of the 1. Place top edge of end cap inside housing lip.
housing using (2) #8 x 1/2” silver self-tapping
2. Attach bottom trim to hold in place.
screws.
ISO. VIEW -
INSIDE CORNER &
INSIDE CORNER CAP
NOTE: Do not install the NOTE: Trim is on the outside of the lens
Page 8
sales@lektroninc.com 918.622.4978 www.lektroninc.com
PLANS PREPARED BY:
200'
XXX
VICINITY MAP
SIGN LEGEND
±815.5
814.0
818.3
LAND USE:
RESTAURANT
ZONING:
CLEMSON, SC 29631
CITY OF CLEMSON
818.0
819.0
EXISTING
SHOPPING
CENTER
PARKING LOT DEVELOPER:
CARROLS, LLC
968 JAMES STREET
SYRACUSE, NY 13203
CONTACT: TOM BROGAN
(315) 424-0513 x 2257
GRADING NOTE:
822.0
821.0
821.5
823.0
R
SITE PLAN
S
C
G
SP-1
(N
The Owner has the option to delete any portion of the contract prior to signing the contract EXISTING 22" OAK OPTIONAL METAL DRIVE ANCHORS, SIT ROOTBALL ON 6" MOUND OF UNDISTURBED SOIL
INSTALLED PER MANUFACTURES DIRECTIONS TO PREVENT SETTLING
or beginning work. This will be a unit price contract. SECTION 19-905. BUFFERYARD, SCREENING AND LANDSCAPING SPECIFICATIONS TO REMAIN
AREA TWICE THE WIDTH OF ROOT BALL
PLANT QUALITY All plants shall be nursery grown, have a full habit of G. Vehicular use area
MULCH RING 2FT BEYOND TREE PIT
growth as is characteristic of that species, and shall be free of disease 1. At least 10% of the total interior square footage of all vehicular use area shall be EXISTING 22" OAK
or insects. General plant quality shall be as specified in the "USA Standard TO REMAIN
for Nursery Stock" (published by the American Association of Nurserymen). dedicated to landscaping
21,700 square feet x 10% = 2,170 SECTION: TREE PLANTING DETAIL
Please contact the Landscape Architect if there is difficulty in locating a
particular plant. If necessary, a substitute plant will be recommended by 2,385 square feet provided CROSS SECTION
LEASE LINE
the Landscape Architect.
H. Landscape requirements of vehicular use area EXISTING 21" OAK
PLANTING HOLES Trees and shrubs: Remove rock and construction debris from planting area. 1. Sufficient upper story trees within and around vehicular use area to ensure any TO REMAIN
Dig holes two to three times as wide as the rootball and only as dep as the height of the EXISTING 12" MAPLE
root ball. Soil at the bottom ot the hole is left undisturbed. See planting detail portion is within 40 ft of a planted, or retained tree trunk
additional information. TO REMAIN
4. Shrubs within a landscape buffer abutting a street right-of-way or within a perimeter SEALS
GLH-48 TOP OF BALL 1"-2" ABOVE GRADE SHAPE OF SHRUB IN THIS DRAWING
SETTING OF PLANTS The root ball of container grown plants shall be scarified of the vehicle use area shall be arranged to form a continuous row (SHRUBS SPACED 4' 0.C.) NOT TYPICAL FOR ALL VARIETIES
in several places prior to planting. Plant shrubs and trees so that the top of the root ball VL-90
will be even with or slightly above the adjacent soil line. SINGLE PLANTING HOLE - backfill REMOVE PAPER, PLASTIC, OR METAL
bottom half of space around the rootball with loosened original soil (use amended soil only when DYH-7 CONTAINER THAT MAY BE AROUND ROOTS
necessary for good soil tilth, (See ORGANIC AMENDMENTS). Tamp lightly. Finish filling the hole MULCH AND WATER ENTIRE BED
with loose soil and gently tamp again. SHRUB BEDS - Backfill bottom half of bed surrounding EXISTING 19" OAK AMENDED BACKFILL MIXTURE OF
1/3 ORGANIC MATTER AND
shrubs with amended backfill (see ORGANIC AMENDMENTS). Tamp lightly and water to settle soil TO REMAIN
Y
STH-3 2/3 SOIL FROM SITE
W
Finish filling hole with loose amended backfill and gently tamp again. Water shrub bed to settle soil. VL-148
H
PLANTINGS NOT DONE IN THIS MANNER SHALL BE REMOVED AND PROPERLY REPLANTED. DIAMETER OF HOLE SHALL
G
BALLS GREATER THAN 2' IN DIAMETER BE TWICE THE DIAMETER
N
ORGANIC AMENDMENTS Organic amendments should be added to backfill for all shrub beds and SGJ-24 SHALL SIT ON MOUND OF UNDISTURBED OF THE ROOT BALL.
LL
)
SOIL TO PREVENT SETTLING. BALLS
KI
W
when deemed necessary to improve soil tilth of single planting holes. Organic matter should comprise
R/
(SHRUBS SPACED SMALLER THAN 2' MAY SIT ON
VI
VL-41
T IC
approximately 10 to 20 percent of this total soil volume. 4' O.C.) COMPACTED SOIL MIXTURE.
O L
ER
EN
D UB
DYH-7
SC (P
PREPARATION OF GROUND COVER AND SEASONAL COLOR BEDS : The existing soil in AREA DOUBLE THE WIDTH OF ROOT BALL
93
RE
G
Y
ground cover and seasonal color beds shall be thoroughly cultivated 6 inches deep, STH-3
W
WO-1
R
H
to a fine texture ( no clods over 1/2") with a mechanical tiller. A plant mix of 60%
G
C
BU
SECTION: SHRUB PLANTING DETAIL
S
screened shredded topsoil, 20% sand, and 20% well rotted sawdust or peat shall then WO-1 1. REV PER ARCH BOARD MTG
LD
be thoroughly incorporated into the existing soil with the tiller so that the soil mix (6" deep) VL-35 01/16/20
is 1/2 original soil and 1/2 plant mix. N.T.S.
O
All groundcover and seasonal color beds shall receive a 2" layer of fine textured, REVISIONS
screened, pine bark mulch, or equal.
PLANTINGS NOT DONE IN THIS MANNER SHALL BE REMOVED AND PROPERLY REPLANTED.
FERTILIZING Upon completion of plantings, all shrubs shall receive 1/6 cup of 16-4-8 VL-80
fertilizer (50% of nitrogen slow release) evenly broadcast at the base of the plants. EXISTING 23" OAK GLH-16
Trees shall receive 1/4 cup of 16-4-8 fertilizer (50% of nitrogen slow release) per (SHRUBS SPACED 4' O.C.) CGD-13
TO REMAIN
inch of caliper. Ground cover beds shall be fertilized at the rate of 20 pounds of TM-2 CLJ-5
16-4-8 ( 50% of nitrogen slow release) per 1000 square feet. CGD-9
LOR-11
SOD
STAKING OF TREES Trees should only be staked if necessary, such as when planted in areas of SOD BE-1 DBH-5
high winds or steep slopes. Under certain circumstances, others may be staked at the discretion SOD
of the Landscape Contractor or Landscape Architect. The Landscape Contractor is responsible
for all wind damage to trees, (provided winds are less than 60 mph) during the guarantee period,
and may stake other trees (for his own protection) at his option. Landscape Contractor will be
responsible for removal of all staking material one year after installation.
TRANSPLANTS All plant material to be transplanted shall be transplanted according to guidelines
SC Highway 93
contractor. Pinestraw: All beds to receive a 4" layer (prior to compaction) of pinestraw. After
natural compaction, pinestraw should have a depth of 2". SOD VL-20
All trees located in lawn areas shall receive a 3' diameter ring of mulch. Mulch in these areas STH-11
is to follow the above listed guidelines.
BNS-5
GRADING All final grading shall be the responsibility of the landscape contractor. The responsibility
for any additional grading (if needed) shall be determined prior to bidding. STH-5 BNS-18
BE-1
BACKFILL Landscape contractor to verify any additional backfill/topsoil needed prior to beginning SOD
work. A unit price for topsoil shall be included in all bid documents to allow for circumstances that
might arise during installation. WO-1
SOD
INSPECTION It shall be the contractor's responsibility to provide for inspection BE-1
of the plant material by the Landscape Architect prior to installation. GLH-23
All plant material will be inspected. Plants not conforming precisely to the plant list SOD
(SHRUBS SPACED AT 4' O.C.)
will not be accepted and shall be replaced at the contractor's own expense.
LICENSES The contractor will be responsible for obtaining all licenses necessary to complete
the work.
SOD SOD
CLEAN UP Final clean up of any disturbances occurring as a result of landscape operations shall be
the responsibility of the landscape contractor. WO-1
INSURANCE With the submittal of bid documents, the landscape contractor shall also submit a
certificate of insurance for workman's compensation and a contractor's general liability. Contractors BE-1
not providing evidence of such insurance will be ineligible to recieve the contract for the job
GUARANTEE All plant material and workmanship to be guaranteed for one year from STH-5
the date of acceptance by the Owner. Plant replacement to occur only once.
The contractor will not be responsible for defects resulting from neglect by the Owner,
abuse or damage by others, or unusual phenomena or incidents beyond the landscape
contractors control which result from natural causes such as floods, lightning, storms, SOD
freezing rains, or winds over 60 miles per hour, fire, vandalism or theft.
PLANT LIST
IRRIGATION Adequate irrigation to support the required plant material shall be required.
KEY QUANTITY COMMON NAME BOTANICAL NAME MINIMUM SIZE AT TIME OF PLANTING
TREE CANOPY TREE CANOPY BE 5 BOSQUE ELM ULMUS PARVIFOLIA 'UPMTF' 2" CALIPER
DRIP-LINE DRIP-LINE EXISTING EXISTING TM 2 TRIDENT MAPLE ACER RUBRUM BUERGERANUM 2" CALIPER
TRANSFORMER MAPLE WILLOW OAK QUERCUS PHELLOS 2" CALIPER
WO 6
BNS 23 BIRD'S NEST SPRUCE PICEA ABIES 'NIDIFORMIS' 3 GALLON
UNDISTURBED AREA CGD 19 CINNAMON GIRL DISTYLIUM DISTYLIUM 'PIIDIST-V' pp27,631 3 GALLON
S:\BURGER KING\CLEMSON\FILES IN\01-17-20 from Georgia\for plotting.dwg | Layout: L1.0
Prepared By : Date :
Optical System
• State-of-the-Art one piece silicone optic sheet delivers industry leading
optical control with an integrated gasket to provide IP66 rated sealed optical
chamber in 1 component.
• Proprietary silicone refractor optics provide exceptional coverage and
uniformity in IES Types 2, 3, 5W, FT and FTA. Product Dimensions
• Silicone optical material does not yellow or crack with age and provides a 16"
typical light transmittance of 93%. (407mm)
• Zero uplight. 4 15/16"
• Available in 5000K, 4000K, 3000K, and 2700K color temperatures per ANSI (126mm)
C78.377. Also Available in Phosphor Converted Amber with Peak intensity
at 610nm.
• Minimum CRI of 70. 28-11/16" (729mm)
• Integral Louver (IL) option available for improved back-light control without
sacrificing street side performance. See page 5 for more details.
& Brackets
LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsi-industries.com • (513) 372-3200 • ©LSI Industries Inc. All Rights Reserved. 11/19/19
Burger King OP018857
Clemson, SC
01/15/20
Design Option A
+-15'-6" - REMODELED EXISTING MONUMENT SIGN Graphic Layout
Page 2
+-7'-4" - REMODELED FASCIA PANELS
Remodeled Existing Sign with New aluminum fascia panels +-5’-0” FASCIA PANEL
and Brake Formed aluminum Box Trim at top and bottom +-2'-7" - REMODELED
each section extended from the existing sign. 4’-0” BK LOGO FASCIA PANELS
New 4’ Dia. LED Illuminated BK Logo installed each side of sign.
4’-0” BK LOGO
End of Existing
MATCH EXISTING
DIMENSIONS TO
Monument Sign
MET
MET
C US