Walk-On
Walk-On
8VHU,QVWUXFWLRQV
ENGLISH
76103-578 Issue 1
C
12.04.2002
©Salter Brecknell Weighing 2002. All rights reserved.
The information contained herein is the property of Salter
Brecknell Weighing and is supplied without liability for errors or
omissions. No part may be reproduced or used except as
authorised by contract or other written permission. The
copyright and the foregoing restriction on reproduction and use
extend to all media in which the information may be embodied.
Declaration of Conformity
Safety
Warnings 3
Safe installation 3
Safe use 3
Cleaning the machine 3
EMC compliance 4
2 Weighing
2.1 Hold function 10
3 Setup mode
3.1 Function setup 12
3.2 Calibration 14
Type PS250
corresponds to the requirements of the following EC directives:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and if not installed and used in accordance with
the instructions manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the following
measures:
Safe use
To avoid the possibility of electric shock or damage to the
machine, always switch off the machine and isolate from the
power supply before carrying out any routine maintenance.
EMC compliance
The following warning may be applicable to your machine.
WARNING:This is a class A product. In a domestic environment
this product may cause radio interference in which case the
user may be required to take adequate measures.
1.2 Display
SALTER
Brecknell
ON-OFF
Net
ZERO
888888.8
HOLD UNITS TARE
0 kg/x è0ç T
kg
Low lb oz
Low
Low battery kg weighing mode
TARE
T
Tare key. Applies a tare value
UNITS
kg/x
Units key Selects weighing units
HOLD
Hold key Retains average weight display.
1.5 Specification
Capacity/resolution 250kg x 0.1kg
550lb x 0.2lb
Display Height 25mm
7 segment LCD
Operating temperature 5º C to 35º C
Weight 22kg
Dimensions
Platform 900mm x 550mm x 50mm
Display head 270mm x 90mm x 45mm
Power supply 6 x 1.2V metal hydride
rechargeable batteries
Recharge adaptor 1 x 100V-240V AC/13V DC
AC adaptor
The 100V/240V recharge adaptor supplied with the PS250 is
provided with four convertion connectors:
2 pin European
3 pin UK
2 pin USA
2 pin Australia
2 Weighing
For best results, always weigh on a hard flat and level surface.
The platform has four adjustable feet for levelling.
ZERO
Press è0ç to switch on the scale. The display will show
ZERO
To switch off the scale, press and hold è0ç .
ZERO
è0ç 0
0.0 kg
2.
15.3 kg
Using tares
3.
ZERO
è0ç 0
0.0 kg
4.
15.3 kg
TARE net
T
0.0
0
kg
5.
net
5.1 kg
6. To cancel a tare
net
15.3 kg
ZERO
è0ç
0
0.0 kg
Weighing units
UNITS
Press kg/x to toggle between kg, lb and oz.
1.
0.0 kg
2.
HOLD
0.0
0
kg
3.
16.3 kg
16.3 kg
HOLD
0
0.0 kg
3 Setup mode
3.1 Function setup
In setup mode you can configure the following functions:
• weighing unit
• auto shut-off
• calibration weight
Auto shut-off switches off the scale if no activity is sensed
during the period set. The time values are in seconds. To
disable auto shut-off, select 2)).
Calibration weight allows you to select full load, 0.5 load or
0.25 load of the machine capacity for calibration. The table
lists the actual weight value you should use.
Calibration weights
Set
kg lb oz
Setup menu
2. Release
TARE
T , display shows 81,7.
UNITS
3. Press kg/x to move across to the option or value you
require.
HOLD
4. Press to select an option and save.
UNITS
Press kg/x until you see End.
HOLD
Press to save your changes and return to weighing
mode.
3.2 Calibration
1. In setup mode, select &$/and then select whether you you
want to use 1/2, full or 1/4 load for calibration (see
’Calibration weights’on page 12). The example shown in
these instructions uses kg weight units and 1/2 load. Save
your selection and then switch off the scale.
1.
Hold
ZERO
è0ç
4076
kg/x x3
lb
2.
TARE
T
0
0 lb
3.
to select alternate units
0
0
UNITS
kg/x
lb
0 kg
4.
100kg
7978 kg
5.
TARE
T
cal kg
lb oz
100.0 kg