Catalog - Low Res

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

PRODUCT

CATALOG

www.mayairgroup.com
World Health Organization, 25 MARCH 2014

7 millions premature deaths annually linked to air pollution.

Our research and development efforts focus on creating technologies that will effectively remove air pollutants swiftly.
As a result, we have emerged as the preferred choice to provide air quality solutions for industrial clean rooms and
laboratories around the world.

Our products are vigorously tested to achieve untainted effectiveness. As such, we have successfully built a reputation
for meeting the strictest requirements, including highly sensitive environment such as biological cleanrooms and
operation theaters in hospital.

Our aim is to produce the best quality products and we will take all necessary measures to ensure that there is no
compromisation. We confidently stand by our promise to our valuable customers – combat air pollutants and create a
healthier environment for them.
Combating Air Pollutants, Purifying And Changing

The Environment For A Better Future

MayAir Group is well-known in leading the industry for manufacturing,


developing and providing air filtration equipment as well as clean air solutions.

With more than 20 years of experience and breakthrough, MayAir stands proven as a dependable producer and
developer of highly effective air filtration equipment and clean air solutions.

Our mission – Deliver clean and health-worthy air.


Creating Clean Air Solutions For
A Sustainable Future
At MayAir, we believe that we all deserve a healthier environment and better quality of life.
This is why we work constantly to continue to create and innovate our highly effective clean air solutions.
Clean Air. Our Future.
Keeping indoor air clean can reduce the chance of spreading coronavirus, according to Shelly Miller,
professor of Mechanical Engineering, University of Colorado Boulder

Coronavirus disease (COVID-19) is an infectious disease caused by a newly discovered coronavirus


that can trigger what doctors call a respiratory tract infection. It can affect your upper respiratory
tract (sinuses, nose, and throat) or lower respiratory tract (windpipe and lungs).

It spreads the same way other coronaviruses do, mainly through person-to-person contact.
Infections range from mild to deadly.

Most people infected with the COVID-19 virus will experience mild to moderate respiratory illness
and recover without requiring special treatment. Older people, and those with underlying medical
problems like cardiovascular disease, diabetes, chronic respiratory disease, and cancer are more
likely to develop serious illness.

Scientists have been warning for months that the coronavirus could be spread by aerosols – tiny
respiratory droplets that people emit when they talk or sneeze and that can linger in the air.

The best way to prevent and slow down transmission is to be well informed about the COVID-19
virus, the disease it causes and how it spreads. Protect yourself and others from infection by washing
your hands or using an alcohol based rub frequently and not touching your face.

But in addition to these precautions, making sure the air inside is as clean as possible can also help.

airqualitynews.com | WHO | theconversation.com


Core Values
Our core values drive our performance and
central our client servicing strategy.

Excellence Innovation Commitment


We always pursuing and performing the We continually challenge ourselves to We are passionate in providing the best
best effort to create highly effective clean explore new and better ways in delivering products and solution to our customer.
technology solutions. Excellence is the the best-fit servicing so that our customer Our priority is to provide the customer with
gradual result of always striving to do can realize their vision. We believe that full support throughout their whole
better. innovation will lead us ahead in the procurement journey.
market.

Reliability Customer satisfaction Teamwork


We emphasize the quality of measure- Every customer is treated with honor. Every employee playing an important
ment by ensuring all products are Meeting their needs remain our highest role, where accountability, integrity and
produced with the highest grade along priority.We work to understand each unity are the key factors to inherent.
with conforming every standards & need, recommend the best solutions, and Teamwork is the secret that makes
requirement. ensure fulfilment of requirement. common people achieve uncommon
results.
Standards Comparisons Chart

U.S. STANDARDS EUROPEAN STANDARDS APPLICATIONS

Air Filter ASHRAE Particle Size Test Aerosol


EN779 EN1822
Standard 52.2 (2017) Efficiency Information

3-10um 1-3um 0.3-1um

Primary Filter MERV 1 <20% Average G1 <65% Gross filter,


Arrestance domestic
MERV 2 <20% of synthentic G2 65-80% and
dust commercial
MERV 3 <20%

MERV 4 <20%

MERV 5 >20% G3 80-90% Commercial,


industrial,
MERV 6 >35% paint shop

MERV 7 >50% G4 >90%

MERV 8 >70% >20%

Secondary Filter MERV 9 >75% >35% Average M5 40-60% IAQ


Efficiency at concerned
MERV 10 >80% >50% 0.4um particles commercial,
Test Aerosol : industrial,
MERV 11 >85% >65% >20% DEHS M6 60-80% medical

MERV 12 >90% >80% >35%

MERV 13 >90% >85% >50% F7 80-90% IAQ


concerned
MERV 14 >95% >90% >75% F8 90-95% commercial,
industrial,
MERV 15 >95% >90% >85% F9 >95% medical,
food etc.
MERV 16 >95% >95% >95%

EPA Filter Integral E 10 85%


Efficiency
at MPPS E 11 95% All types of
Test Aerosol : cleanrooms
DOP E 12 99.5%

HEPA Filter H 13 99.95%

H 14 99.995%

ULPA Filter

U 15 99.9995%

U 16 99.99995% Superior
cleanroom
U 17 99.999995%

ASHRAE 52.2
Filter testing was originated from America in 1930 (ASHVE and AFI code). It was then reviewed and modified in 1967 and 1968. ASHRAE collaborated
with American National Standard Institude (ANSI) in 1992 to create ASHRAE-ANSI 52.1. Final update for ASHRAE 52.2 was in 2017.

EN 779
It was the first European's Air filter test method in 1993, built on the foundations of Eurovent 4/5. This standard was modified later in 2002 and 2012.
Only covers primary and secondary filters.

EN 1882
It is the improvisation from Eurovent 4/4 in 1998. This standard was modified only once in 2010. It covers high efficiency filters (E10 and above).

www.mayairgroup.com | info@mayair.com.my
6
Application - Commercial Buildings

1 2 3

6
8 7
9

MayAir has the right expertise to recommend the best solutions and products
for commercial buildings to generate clean air.

Recommended range of products:

1 2 3 4

Primary Filter Electronic Air Cleaner Secondary and Fresh Air System
and Nano Photocatalyst HEPA Filter
Page24 Page 12 - Page 21

5 6 7 8

Ceiling-mounted Air Purifier Online Monitoring System Intelligent Fresh Air System High Air Flow
D-Breath 4 & D-Breath 7 contact MayAir contact MayAir Germicidal Air Purifier
Page 27 - Page 28 for product specifications for product specifications D-Guard 5
Page 26

Air Purifier 401

www.mayairgroup.com | info@mayair.com.my
7
Application - Residential Buildings

3
6
1

MayAir has the capabilities to provide tailor-made solutions


for residential buildings based on our clients’ needs.

Recommended range of products:

1 2 3 4

Intelligent Fresh Air System Air Purifier 401 Air Purifier 301 Online Monitoring System
contact MayAir contact MayAir
for product specifications for product specifications

5 6

Fresh Air System High Air Flow


Germicidal Air Purifier
D-Guard 5
Page 26

www.mayairgroup.com | info@mayair.com.my
8
Application - School

7
6
5
4

3
2
1

MayAir has the right expertise to recommend the best solutions and products
for schools to generate clean air.

Recommended range of products:

1 2 3 4

Primary Filter Electronic Air Cleaner Secondary and Online Monitoring System
and Nano Photocatalyst HEPA Filter contact MayAir
Page24 Page 12 - Page 21 for product specifications

5 6 7

Ceiling-mounted Air Purifier Air Purifier 401 High Air Flow


D-Breath 4 & D-Breath 7 Germicidal Air Purifier
Page 27 - Page 28 D-Guard 5
Page 26

www.mayairgroup.com | info@mayair.com.my
9
Application - Hospital

Primary Filter
Secondary Filter
Semi HEPA/HEPA
Germicidal Photocatalytic
1 2 3 4

Fresh Air/Return Air

Ceiling

7
HEPA BIBO

3 8

5 6 Ceiling Mounted

Supply Air Return Air HEPA Replaceable Ceiling Module Isolation Room
Electrostatic Germicidal

9 9
D-Guard 5 D-Guard 5
10
NFU 11
D-Edge

12
AP401
EHU
13

MayAir clean solution technology fit well into


Hospitals by delivering effective filtration products and equipment.

Recommended range of products:

1 2 3 4 5

Primary Filter Secondary Filter HEPA Filter Electronic Ceiling-mounted Air Purifier
Page 12 - Page 21 Air Cleaner D-Breath 4 & D-Breath 7
Page 27 - Page 28

6 7 8 9 10

HEPA Replacement BIBO M-NML High Air Flow NFU


Ceiling Module Page 24 Germicidal Air Purifier
D-Guard 5
Page 26

11 12 13 14

D-Edge Air Purifier 401 EHU Air Duct EAC


Page 25

www.mayairgroup.com | info@mayair.com.my
10
HEPA
FILTER
www.mayairgroup.com
Semi-High Efficiency Air Filter Product Features
with Separator

M-SHI
Operating Conditions
Continuous operating temperature: Max. 176°F (80°C)
Operating relative humidity: ≤100 (%RH)

Frame
Material: Galvanised steel / aluminium / stainless steel /
plywood
Nominal Thickness (inch) : 31 7 , 3¾, 6, 82 3, 11½
Header: Non-header / single header / double header
thickness (inch) : 4 5

Media
Material: Fiberglass

Efficiency (EN1822:2009)
E10, E11, E12

Sealant
Applications Material: Polyurethane glue

Separator
Cleanroom Industrial Material: Corrugated aluminium foil / paper*

Commercial
General
Building

Graph Of Initial Pressure Drop Versus Air Flow

1.00

0.80
E12
E11
0.60
Pressure drop (in. w.g.)

E10
0.40

0.20

930 m³/h (545 CFM) 1400 m³/h (825 CFM) 1860 m³/h (1095 CFM) 2320 m³/h (1365 CFM)
According to model M-SHI-24x24x11½(inch) Non-header Air flow

Product Specifications
Nominal Actual Face Air Recommended Final
Dimension Dimension Velocity Flow Initial Pressure Drop Pressure Drop
(inch) (inch) (FPM) (CFM) (in. w.g.) (in. w.g.)
WxHxD WxHxD H10 H11 H12
12x24x3 12x24x3 1 7 71 120 0.40 0.52 0.56 1.81
24x24x3 24x24x3 1 7 71 245 0.40 0.52 0.56 1.81
12x24x6 12x24x6 152 245 0.40 0.52 0.56 1.81
24x24x6 24x24x6 152 530 0.40 0.52 0.56 1.81
12x24x9 12x24x8 2 3 236 385 0.40 0.52 0.56 1.81
24x24x9 24x24x8 2 3 236 825 0.40 0.52 0.56 1.81
12x24x12 12x24x11 1 2 315 505 0.40 0.52 0.56 1.81
24x24x12 24x24x11 1 2 315 1095 0.40 0.52 0.56 1.81

Remarks: 1. Tolerance of initial pressure drop is ± 10%.


2. Tolerance of dimension is ± 0.12 inch.
3. Other dimensions are available upon request.

www.mayairgroup.com | info@mayair.com.my
12
Semi-High Efficiency Mini-Pleated Product Features
Air Filter

M-SHII
Operating Conditions
Continuous operating temperature: Max. 176°F (80°C)
Operating relative humidity: ≤100 (%RH)

Structure/Arrangement
Ultra-slim and compact design
Faceguard: Epoxy powder coated steel mesh

Frame
Material: Galvanised steel / extruded aluminium /
stainless steel
Nominal Thickness (inch): 2, 2 ¾, 31 7 , 3½, 3¾, 4, 41 3

Media
Material: Fiberglass

Efficiency (EN1822:2009)

Applications E10, E11, E12

Sealant

Cleanroom Industrial Material: Polyurethane glue

Separator
Material: Hot melt bead
Commercial
General
Building

Graph Of Initial Pressure Drop Versus Air Flow

1.00

0.80 E12
E11
0.60
Pressure drop (in. w.g.)

E10

0.40

0.20

700 m³/h (410 CFM) 1050 m³/h (620 CFM) 1400 m³/h (825 CFM) 1750 m³/h (1030 CFM)
According to model M-SHII-24x24x3 3 4 (inch) Non-header Air flow

Product Specifications
Nominal Actual Faceguard Air Flow Face Velocity Initial Pressure Drop
Dimension Dimension
(inch) (inch) (CFM) (FPM) (in. w.g.)

WxHxD WxHxD E10 E11 E12


12x24x2 12x24x2 290 167 0.38 0.49 0.58
24x24x2 24x24x2 605 167 0.38 0.49 0.58
Double/ Single Faceguard

12x24x2.8 12x24x2 3 4 335 197 0.38 0.49 0.58


24x24x2.8 24x24x2 3 4 705 197 0.38 0.49 0.58
12x24x3 12x24x3 1 7 335 197 0.38 0.49 0.58
24x24x3 24x24x3 1
7 705 226 0.38 0.49 0.58
12x24x4 12x24x3 1 2 390 226 0.38 0.49 0.58
24x24x4 24x24x3 1 2 825 226 0.38 0.49 0.58
12x24x4 12x24x3 3 4 390 226 0.38 0.49 0.58
24x24x4 24x24x3 3
4 825 226 0.38 0.49 0.58
12x24x4 12x24x4 390 226 0.38 0.49 0.58
24x24x4 24x24x4 825 226 0.38 0.49 0.58

Remarks: 1. Tolerance of initial pressure drop is ± 10%. 2. Tolerance of dimension is ± 0.12inch. 3. Other dimensions are available upon request.

www.mayairgroup.com | info@mayair.com.my
13
Semi-High Efficiency V-Shaped Product Features
Mini-Pleated Air Filter

M-SHV
Operating Conditions
Continuous operating temperature: Max. 176°F (80°C)
Operating relative humidity: ≤100 (%RH)

Structure/Arrangement
Mini-pleated media assembled into V-bank configuration
for greater air flow and longer service life

Frame
Material: Galvanised steel / aluminium / ABS
Nominal Thickness (inch): 11½
Header: Non-header / single header / double header
thickness (inch) : 4 5

Media
Material: Fiberglass
Separator: Hot melt bead
Applications
Efficiency (EN1822:2009)
E10, E11, E12
Cleanroom Industrial
Sealant
Material: Polyurethane glue
Commercial
General
Building

Graph Of Initial Pressure Drop Versus Air Flow

1.20

E12
1.04

0.88 E11
Pressure drop (in. w.wg.)

E10
0.72

0.56

0.40

0.24

1350 m³/h (795 CFM) 2025 m³/h (1190 CFM) 2700 m³/h (1590 CFM) 3375 m³/h (1990 CFM)
According to model M-SHV-594x594x292(mm) Single header with gross media area of 18.3m² Air flow

Product Specifications
Nominal Actual Initial Pressure Drop Recommended
V-Shape Header Air Flow
Dimension Dimension at 2.5 m/s Final Pressure Drop
(inch) (inch) (V) (Non/Single/Double) CFM (in. w.g.) (in. w.g.)

WxHxD WxHxD E10 E11 E12

12x24x12 112 7 x 23 1 3 x 111 2 2V Single Header 705 0.60 0.72 0.86 1.81

24x12x12 23 1 3 x 112 7 x 111 2 4V 705 0.60 0.72 0.86 1.81

24x20x12 23 1 3 x 192 7 x 111 2 4V Single Header 1295 0.60 0.72 0.86 1.81

24x24x12 23 1
3 x 231
3 x 11
1
2 4V 1590 0.60 0.72 0.86 1.81

12x24x12 12x24x111 2 2V 825 0.60 0.72 0.86 1.81


Non-Header
24x24x12 24x24x111 2 4V 1765 0.60 0.72 0.86 1.81

Remarks: 1. Tolerance of initial pressure drop is ± 10%.


2. Tolerance of dimension is ± 0.12 inch.
3. Other dimensions are available upon request.

www.mayairgroup.com | info@mayair.com.my
14
High Efficiency Particulate Air Filter Product Features
with Separator

M-HI
Operating Conditions
Continuous operating temperature: Max. 176°F (80°C)
Operating relative humidity: ≤100 (%RH)

Frame
Material: Galvanised steel / aluminium / stainless steel /
plywood
Nominal Thickness (inch): 3 1 7 , 6 , 8 2 3 , 11½
Header: Non-header / single header / double header
Thickness (inch): 4 5

Media
Material: Fiberglass

Efficiency (EN1822:2009)
H13, H14

Sealant
Applications Material: Polyurethane glue

Separator
Cleanroom Industrial Material: Corrugated aluminium foil / paper*

Commercial
General
Building

Graph Of Initial Pressure Drop Versus Face Velocity (Standard Air Flow)

1.60

1.40 H14

1.20 H13

1.00
Pressure drop (in. w.g.)

0.80

0.60

0.40

0.20

0.00

0.4 m/s (79 FPM) 0.8 m/s (157 FPM) 1.2 m/s (236 FPM) 1.6 m/s (315 FPM) 2.0 m/s (394 FPM) 2.4 m/s (472 FPM)
According to model M-HI-24x24x11½ (inch) Standard air flow Face velocity

Graph Of Initial Pressure Drop Versus Face Velocity (High Air Flow)

1.80
H14-H
1.60
H13-H
1.40
1.20
Pressure drop (in. w.g.)

1.00
0.80
0.60
0.40
0.20
0.00

0.625 m/s (128 FPM) 1.25 m/s (246 FPM) 1.875 m/s (369 FPM) 2.5 m/s (492 FPM) 3.125 m/s (615 FPM) 3.75 m/s (738 FPM)
According to model M-HI-24x24x11½ (inch) High air flow Face velocity

www.mayairgroup.com | info@mayair.com.my
15
Graph Of Initial Pressure Drop Versus Face Velocity (High Air Flow & Low Pressure Drop)

2.40
2.20
H14-HL
2.00
1.80 H13-HL
Pressure drop (in. w.g.)

1.60
1.40
1.20
1.00
0.80
0.60
0.40

1.25 m/s (246 FPM) 1.875 m/s (359 FPM) 2.5 m/s (492 FPM) 3.125 m/s (615 FPM)
According to model M-HI-24x24x11½ (inch) High air flow & low pressure drop Face velocity

Product Specifications (Standard Air Flow)


Nominal Actual Face Initial
Dimension Dimension Air Flow Velocity Pressure Drop
(inch) (inch) (CFM) (FPM) (in. w.g.)
WxHxD WxHxD H13 H14
12x24x3 12x24x3 1 7 120 71 1.00 1.13
24x24x3 24x24x3 1 7 250 71 1.00 1.13
12x24x6 12x24x6 250 152 1.00 1.13
24x24x6 24x24x6 530 152 1.00 1.13
12x24x9 12x24x8 2 3 383 236 1.00 1.13
24x24x9 24x24x8 2 3 825 236 1.00 1.13
12x24x12 12x24x11½ 505 315 1.00 1.13
24x24x12 24x24x11½ 1095 315 1.00 1.13

Product Specifications (High Air Flow)*


Nominal Actual Face Initial
Dimension Dimension Air Flow Velocity Pressure Drop
(inch) (inch) (CFM) (FPM) (in. w.g)
WxHxD WxHxD H13 H14
12x24x3 12x24x3 1
7 235 118 1.00 1.13
24x24x3 24x24x3 1 7 470 118 1.00 1.13
12x24x6 12x24x6 325 197 1.00 1.13
24x24x6 24x24x6 690 197 1.00 1.13
12x24x9 12x24x8 2
3 500 305 1.00 1.13
24x24x9 24x24x8 2 3 1070 305 1.00 1.13
12x24x12 12x24x11½ 660 394 1.00 1.13
24x24x12 24x24x11½ 1410 394 1.00 1.13

Product Specifications (High Air Flow & Low Pressure Drop)


Nominal Actual Face Initial
Dimension Dimension Air Flow Velocity Pressure Drop
(inch) (inch) (CFM) (FPM) (in. w.g)
WxHxD WxHxD H13 H14

12x24x12 12x24x11½ 1000 492 1.33 1.53

24x24x12 24x24x11½ 2000 492 1.33 1.53

Remarks: 1. Tolerance of initial pressure drop is ± 10%.


2. Tolerance of dimension is ± 0.12 inch.
3. Other dimensions are available upon request.

www.mayairgroup.com | info@mayair.com.my
16
High Efficiency Particulate V-Shaped Product Features
Mini-Pleated Air Filter

M-HV
Operating Conditions
Continuous operating temperature: Max. 176°F (80°C)
Operating relative humidity: ≤100 (%RH)

Structure/Arrangement
Mini-pleated media assembled into V-bank
configuration for greater air flow and longer service life

Frame
Material: Galvanised steel / aluminium / ABS
Nominal Thickness (inch) : 11½
Header: non-header / single header / double header
Thickness (inch): 4 5

Media
Material: Fiberglass
Separator: Hot melt bead

Applications Efficiency (EN1822:2009)


H13, H14

Cleanroom Industrial Sealant


Material: Polyurethane glue

Commercial
General
Building

Graph Of Initial Pressure Drop Versus Face Velocity (Standard Air Flow)

1.60

1.40
H14
1.20 H13

1.00
Pressure drop (in. w.g.)

0.80

0.60

0.40

0.20

0.00

1.0 m/s (197 FPM) 1.5 m/s (295 FPM) 2.0 m/s (394 FPM) 2.5 m/s (492 FPM)
According to model M-HV-24x24x11½ (inch) Single header with 202 ft2 (Standard air flow) Face velocity

Graph Of Initial Pressure Drop Versus Face Velocity (High Air Flow)

1.40
H14-H
H13-H
1.20
Pressure drop (in. w.g.)

1.00

0.80

0.60

0.40

1.5 m/s (295 FPM) 2.0 m/s (394 FPM) 2.5 m/s (492 FPM) 3.0 m/s (591 FPM)
According to model M-HV-24x24x11½ (inch) Single header with 202 ft2 (High air flow) Face velocity

www.mayairgroup.com | info@mayair.com.my
17
Graph Of Initial Pressure Drop Versus Face Velocity (High Air Flow & Low Pressure Drop)

1.60

1.40

1.20 H14-HL
1.00 H13-HL
Pressure drop (in. w.g.)

0.80

0.60

0.40

0.20

0.00

2.0 m/s (394 FPM) 2.5 m/s (492 FPM) 3.0 m/s (591 FPM) 3.5 m/s (689 FPM)
According to model M-HV-24x24x11½ (inch) Single header with 253 ft2 (High air flow & low pressure drop) Face velocity

Product Specifications (Standard Air Flow)*


Nominal Actual Face Initial
Dimension V-Shape Air Flow Velocity Pressure Drop
Dimension
(inch) (inch) (V) (CFM) (FPM) (in. w.g.)
WxHxD WxHxD H13 H14
12x24x12 112 7 x23 1 3 x11½ 2V 590 1.0 1.1
24x12x12 23 1 3 x112 7 x11½ 4V 590 1.0 1.1
24x20x12 23 1 3 x11 2 7 x11½ 4V 1060 394 1.0 1.1
24x24x12 23 1
3 x19 2
7 x11½ 4V 1295 1.0 1.1
24x24x12 24x24x11½ 4V 1410 1.0 1.1
12x24x12 12x24x11½ 2V 705 1.0 1.1

Product Specifications (High Air Flow)*


Nominal Actual Face Initial
Dimension Dimension V-Shape Air Flow Velocity Pressure Drop
(inch) (inch) (V) (CFM) (FPM) (in. w.g.)
WxHxD WxHxD H13 H14
12x24x12 112 7 x23 1 4 x11½ 2V 705 1.0 1.1
24x12x12 23 1 3 x112 7 x11½ 4V 705 1.0 1.1
1 2
24x20x12 23 3 x19 7 x11½ 4V 1295 492 1.0 1.1
24x24x12 23 1 3 x23 1 3 x11½ 4V 1590 1.0 1.1
24x24x12 24x24x11½ 4V 1765 1.0 1.1
12x24x12 12x24x11½ 2V 825 1.0 1.1

Product Specifications (High Air Flow & Low Pressure Drop)


Nominal Actual Face Initial
Dimension Dimension V-Shape Air Flow Velocity Pressure Drop
(inch) (inch) (V) (CFM) (FPM) (in. w.g.)
WxHxD WxHxD H13 H14
24x12x12 24x12x11½ 5V 1060 1.0 1.1
650
24x24x12 24x24x11½ 5V 2355 1.0 1.1

Remarks: 1. Tolerance of initial pressure drop is ± 10%.


2. Tolerance of dimension is ± 0.12 inch.
3. Other dimensions are available upon request.

www.mayairgroup.com | info@mayair.com.my
18
High Efficiency Particulate Mini-Pleated Product Features
Air Filter

M-HII
Operating Conditions
Continuous operating temperature: Max. 176°F (80°C)
Operating relative humidity: ≤100 (%RH)

Structure/Arrangement
Ultra-slim and compact design

Frame
Material: Anodised aluminium
Nominal Thickness (inch): 2, 2¾, 3½, 4 1 3

Media
Material: Ultrafine fiberglass

Efficiency (EN1822:2009)
H13, H14
Applications
Sealant
Material: Polyurethane glue
Cleanroom General

Separator
Material: Hot melt glue
Semiconductor

Graph Of Initial Pressure Drop Versus Face Velocity

0.80
0.70
0.60
H14
0.50
H13
Pressure drop (in. w.g.)

0.40
0.30
0.20
0.10
0.00

0.35 m/s (69 FPM) 0.4 m/s (79 FPM) 0.45m/s 0.45 m/s (89 FPM) 0.5m/s 0.5 m/s (98 FPM)
According to model M-HII-22 4 9 x22 4 9 x2 3 4 (inch) Face Velocity (m/s) Face velocity

www.mayairgroup.com | info@mayair.com.my
19
Product Specifications

Nominal Dimension Actual Dimension Thickness Air Flow Face Velocity Initial Pressure Drop

(inch) (inch) (inch) (CFM) (FPM) (in. w.g.)


WxHxD WxH H13 H14
1x2 12x24 120 69 0.43 0.46
2x2 22 4 9 x22 4 9 215 69 0.43 0.46
2.5x2 30x24 315 69 0.43 0.46
3x2 36x24 2 380 69 0.43 0.46
4x2 46x22 4 9 455 69 0.43 0.46
4x3 46x34 1 4 710 69 0.43 0.46
4x4 46x46 965 69 0.43 0.46
1x2 12x24 150 89 0.40 0.44
2x2 22 4 9 x22 280 89 0.40 0.44
2.5x2 30x24 405 89 0.40 0.44
3x2 36x24 2 3
4 490 89 0.40 0.44
4x2 46x224 9 590 89 0.40 0.44
4x3 46x341 4 910 89 0.40 0.44
4x4 46x46 1235 89 0.40 0.44
1x2 12x24 150 89 0.30 0.32
2x2 224 9 x224 9 280 89 0.30 0.32
2.5x2 30x24 405 89 0.30 0.32
3x2 36x24 31 2 490 89 0.30 0.32
4x2 46x22 4 9 590 89 0.30 0.32
4x3 46x34 1
4 910 89 0.30 0.32
4x4 46x46 1235 89 0.30 0.32
1x2 12x24 150 89 0.24 0.26
2x2 224 9 x22 4 9 280 89 0.24 0.26
2.5x2 30x24 405 89 0.24 0.26
3x2 36x24 41 3 490 89 0.24 0.26
4x2 46x22 4 9 590 89 0.24 0.26
4x3 46x34 1 4 910 89 0.24 0.26
4x4 46x46 1235 89 0.24 0.26

Remarks: 1. Tolerance of initial pressure drop is ± 10%.


2. Tolerance of dimension is ± 0.12 inch.
3. Other dimensions are available upon request.

www.mayairgroup.com | info@mayair.com.my
20
High Efficiency Particulate Mini-Pleated Product Features
Air Filter (PTFE)

M-HII-PTFE
Operating Conditions
Continuous operating temperature: Max. 176˚F (80°C)
Operating relative humidity: ≤100 (%RH)

Frame
Material: Anodized extruded aluminium profile
Nominal Thickness (inch): 11 6 , 2, 23 4

Media
Material: PTFE with low outgassing

Efficiency (EN1822:2009)
H13, H14

Faceguard
Material: Epoxy powder coated steel, aluminium

Applications
Low Initial Pressure Drop

Cleanroom Industrial
Sealant
Material: Polyurethane glue
Semiconductor
General

Graph Of Initial Pressure Drop Versus Face Velocity

0.64
0.56

0.48

0.40
Pressure drop (in. w.g.)

0.32
H13/H14
0.24

0.16

0.08

0.00

0.35 m/s (69 FPM) 0.4 m/s (79 FPM) 0.45 m/s (89 FPM) 0.5 m/s (98 FPM)
According to model M-HII-PTFE-22 4 9 x224 9 x2 3 4 (inch) Face velocity

Product Specifications
Nominal Actual Thickness
Face Initial
Dimension Dimension Velocity Pressure Drop
(inch) (inch) (inch) (FPM) (in. w.g.)
WxH WxH H13 H14
2x2 22 4 9 x22 4 9 70 0.30 0.30
2x4 22 4 9 x46 11 6 70 0.30 0.30
4x4 46x46 70 0.30 0.30
2x2 22 4
9 x22 4
9 90 0.25 0.25
2x4 224 9 x46 2 90 0.25 0.25
4x4 46x46 570x570 90 0.25 0.25
2x2 224 9 x22 4 9 90 0.15 0.15
2x4 22 4
9 x46 2 3
4 90 0.15 0.15
4x4 46x46 90 0.15 0.15

Remarks: 1. Tolerance of initial pressure drop is ± 10%.


2. Tolerance of dimension is ± 0.12 inch.
3. Other dimensions are available upon request.

www.mayairgroup.com | info@mayair.com.my
21
Optional Feature for HEPA Filter (Argenzil Silver Ion)

Throughout the global medical and health sector, in North America and European countries particularly,
silver ion sterilization technology has been well developed and implemented. Application of silver ion is
proven stable with no side effects. It has been recognized as the safest sterilization agent by NASA and is
widely applied in biotechnology, medical health, aerospace warships and other fields.

For years, MayAir has been introducing its advanced Argenzil Silver-ions sterilizing technology for various
application and industries. Integrated with ultrafine fiberglass filter material, the technology can inhibit the
growth and reproduction of bacteria and microorganisms in the air by interfering the synthesis of their
microbial cell wall and protein.

1. A layer of antimicrobial active substance 2. When all kinds of microorganisms come


is attached to the surface of the filter media. into contact with the surface of filter media,
they will be killed by the antimicrobial active
substances.

4. Advanced sustained-release technology for 3. Broad spectrum. Highly efficient towards the
long-term antimicrobial effect. inhibition of microbial reproduction.
Number of colonies on the filter

Traditional air filter


vs
Air filter with silver-ions

Time

www.mayairgroup.com | info@mayair.com.my
22
AIR
PURIFICATION
UNIT
www.mayairgroup.com
Fan Coil Unit Type Product Features
(FP Series)

M-NML
Efficiency
Germicidal efficiency: >99%
Formaldehyde / TVOC removal efficiency: >95%

Applications

Commercial
Industrial
Building

Healthcare &
General
Hospital

Principles
UV-C Light (Ultraviolet Sterilisation)
UV light are catagorised into 4 different wavebands.
C waveband (UV-C): With sterilisation effect at the wavelength of 200-275 nm,
UV light at the wavelength of 254nm comes with high germicidal effect as it easily absorbed by living organisms. The photon energy ables to
disintegrate DNA and RNA molecular structure of microorganisms. By breaking down the structure through photochemical reaction, the
microorganisms lose the ability to reproduce and thus lead to death of the cells & sterilisation effect occured.

Photocatalytic (Photocatalyst)
Nano photocatalyst is activated when specific wavelength of light is emitted. This will lead to the generation of electron-hole pairs and it
then allows the photo-catalyst to react with the surrounding H2O and O2 molecules. The production of hydroxyl free radicals will enable the
harmful contaminants to be captured and subsequently disintegrate the molecular structure and inhibit the growth of germs and viruses.

UV-C Light Spectrum Diagram

X-Ray UV Light Visible Light Infrared

100 200 280 315 400 780 wavelength (nm)

Highest Peak of Sterilisation 254nm

UV-C at wavelength of 254nm comes with the best sterilisation effect

Electron
Transition Decomposition

UV Absorption
Nano Form
Electron- Hydroxyl Redox Yield
Fresh
Light Photocatalyst hole
Yield
Radicals Air

Transition
Sterilisation
Hole

Product Specifications (Single-Ended Probe)


Air Volume Outer Dimension (with ballast) Input Voltage (V) Power Weight
Serial Number
(CFM) HXD (inch x ±2%) / Current (A) (W) (Ibs)
NML-265x50-FP-6 175 10x2 6 2.2
NML-360X50-FP-15 880 14x2 15 2.6
NML-275x50-FP-6 175 11x2 6 2.4
1Ph/220V/50Hz
NML-370X50-FP-15 880 15x2 15 2.9
NML-490x50-FP-23 1470 19x2 23 3.3
NML-605X50-FP-28 2355 24x2 28 4.2

www.mayairgroup.com | info@mayair.com.my
24
Portable Exhaust Product Features
Air Handling Unit

EHU
EC Fan with High Air Volume
Stable performance

Nylon Pre-Filter
Washable and do not require replacement

High quality
High quality sheet metal with good welding & spray
coating

Efficiency (EN1822:2009)
H13, H14

Good Sealing
Good rust and good moisture resistance

Applications Customization Available


Diversified controls and optional add ons
Cleanroom Industrial

Semiconductor
General

Structure Layout Operating Principle Diagram

Indoor Recirculating Exhaust Air Outlet


Air Outlet
Fan
Negative pressure isolation ward

Casing Antimicrobial HEPA Filter Clean air


Touch Screen Inspection Access Panel Outdoor air
Panel Clean air
Indoor air
On/Off Switch recirculation Exhaust air

Pre-Filter
Contaminated
Indoor air air
Circuit Board recirculation

UV

Plug

Wheels

Product Specifications EHU (Standard)

Fan Speed Low Medium High


Power Supply 1Ph/120V/60Hz
Power (W) 21 70 142
Air Volume (ft³/min) 120 235 350
Noise Level (dB (A) ) 40 53 61
Aerosol Removal Efficiency 99.91% 99.95% 99.60%
Particulate Matter CADR (CFM) 88 154 198
Negative Pressure (Pa) (¼ Exhaust) 50 98 123
Outer Dimension (inch) 41(H)x24(W)x12(D)
Casing Material SPCC
Pre-filter Size (inch) 17.7x17.7x0.4
Antimicrobial HEPA Filter Size (inch) 19.0x19.0x2.8
Air Outlet Size (inch) 8x4
Exhaust Vent Size (inch) Ø4
Coverage Area (ft²) 431 (¼ Exhaust) ~ 1076 (Full Exhaust)
Weight (Ibs) 71

www.mayairgroup.com | info@mayair.com.my
25
Germicidal Air Purifier Product Features

D-Guard 5 Structure/Arrangement
Filter arrangement: Pre-filter, germicidal HEPA filter,
formaldehyde VOC air filter
Efficiency
PM2.5 purification effeciency: 99.90%
Formaldehyde removal efficiency: 99%
Sterilization efficiency (Staphylococcus albus): 99.89%
Clean Air Output Ratio (CADR): 1160m3/h

Low Energy Consumption

Low Noise Level

Anti-bacterial Or Anti-fungal Growth

Applications Multiple Filtration Layer


Effectively remove PM0.3, PM2.5, TVOC, HCHO and microbes.
Commercial Industrial grade ultrafine fiberglass, 99.99% removal efficiency for
General
Building particle size above 0.3µm.

Healthcare &
Hospital

Clean Air Delivery Rate (CADR) Structure Layout


Tips: CADR stands for clean air delivery rate. It refers to the total amount
of clean air output after filtration. The unit is m³/h. Pre-Filter Air Outlet
Purified Air
HEPA Filter
CADR of particulate matter- Dust Carbon Filter
CADR CADR of gaseous contaminants - HCHO, TVOC Contaminated Air

D-Guard 5 (CADR):1159.92m³/h Air Inlet (Motor)


Suggested coverage area:100㎡

Removal
Removal Removal
efficiency of
efficiency of efficiency of
Microbes - MULTIPLE operating speed:
TVOC- 90% PM2.5- 99.9%
99.98% User friendly touch screen panel for
operating speed controlling. D-Guard

Product Specifications (Stand Alone Type)

Product Name D-Guard 5

Casing Material Powder Coated Steel Alloy


Dimension (WxHxD) (Inch) 40x62x7
Colour Pearl-White
Weight (Ibs) 187
Display Panel 3 control mode
Speed High Medium Low
Air Volume (ft3/min) 880 395 140
Noise Level (dB(A)) 55 45 30
Power Consumption (W) 206 40 15
Power Input 1PH / 120V / 60Hz
Recommended Area Served (ft2) 1076 - 2153
Filtration Cycle / Hour 5 times
Controller Touch panel

www.mayairgroup.com | info@mayair.com.my
26
Germicidal Air Purifier Product Features
(Mechanical Type)

D-Breath 4.1
Structure/Arrangement
Filter arrangement: Pre-filter, HEPA filter,
chemical filter

Efficiency
PM2.5 purification effeciency: 99% (30m3, 20mins)

Low Energy Consumption

Low Noise Level

Anti-bacterial Or Anti-fungal Growth


Applications

Commercial
General
Building

Healthcare &
Hospital

Structure Layout

33/12
33/26

12
33 /26

Product Specifications (Ceiling-mounted Type)

Product Name D-Breath 4.1

Dimension (WxHxD) (inch) 33x33x12 26x26x12


Colour Pearl-White Pearl-White
Speed High Medium Low High Medium Low
Air Volume (ft /min)
3 590 29543 175 470 295 205
Noise Level (dB(A)) 52 43 32 50 43 35
Power Consumption (W) 69 49 25 56 40 24
Power Input 1PH / 220V / 50Hz
Casing Material Galvalume
Controller Remote control, Touch Panel, Group control system

Remarks: 1. The parameters are subjected to change without prior notice.

www.mayairgroup.com | info@mayair.com.my
27
Ceiling mount re-circulating Product Features
air purifier

D-Breath 7 Utilize media type air filter, no ozone production.

Ceiling mount installation, lower installation risk, no airflow


obstructions.

Standalone equipment, readily re-positioned, dismantled or installed


based on office modification.

German EBM fan, excellent performance, longer lifetime, lower noise


and lower power consumption.

Stable operating condition, vibration lower than 0.6mm/s.

Various control method, can be integrated into centralized group


control system.

Air purifier installation schematic diagram

Applications
Slab

Commercial
General
Building
Air filter Air purifier Duct

Return air Ceiling Air outlet


Healthcare &
Hospital

MayAir’s Customized Air Filter Selection

HCHO removal filter


Patented Decotec™ Filter Technology
Normal carbon filter will continue to absorb HCHO from the surrounding air until it is saturated. Under certain
temperature and humidity condition, the contaminants might be released again. MayAir’s HCHO removal
filter with patented Decotec™ technology utilizes the media incorporated with patented Decotec technology
It absorbs the HCHO from the air and completely decompose them into air and water. Secondary pollution
can be prevented.

Germicidal filter
Patented Inactec™ Filter Technology
MayAir’s HEPA filter with patented Inactec™ technology utilizes the media incorporated with ionic silver
technology. It captures and collects the tiny particles within the media and to enhance it with sterilizing
effect with the aim to prevent secondary contamination.

Product Specifications (Stand Alone Type)

Product Series D-Breath 7

Casing Material Paint Coated Steel Panel


Dimension (LxWxH) (Inch) 38 x 20 x 14
Duct Diameter (Inch) Ø 10
Weight (Ibs) 62
Power Supply Input 1PH/220V/50Hz
Control Method Wall Mount Control Panel / Computerised Group Control System
Operating Mode High Medium Low
Power Consumption (W) 229 86 21
Air Handling Volume (CFM) 589 383 235
Noise dB(A) 48 43 38
PM2.5 Single Pass Efficiency >95%

www.mayairgroup.com | info@mayair.com.my
28
5
MayAir Manufacturing (M) Sdn Bhd
No.35, Jalan P4/6, Seksyen 4, Bandar
Teknologi Kajang, 43500 Semenyih,
Selangor, Malaysia.

Tel: +603-8210-7373 / 7376


Fax: +603-8210-7337

Email: info@mayair.com.my
Website:www.mayair.com.my
Website:www.mayairgroup.com

You might also like