Efficiency calculation
Agenda
Fan Inspection
Pressures and Calculations
Measurements
Efficiency Calculation
© by LOESCHE GmbH
Fan Inspection
compensator(s) compensator(s)
1
Fan Inspection
a b c
© by LOESCHE GmbH
Rev.1 - 13/11/2010 13/10/2011 4
Fan Inspection
Fan Inspection
© by LOESCHE GmbH
2
Fan Inspection
© by LOESCHE GmbH
correct if damper above is closed or opened!
Rev.1 - 13/11/2010 13/10/2011 7
Fan Inspection
Impeller
easy to turn by hand
alingment against: Inlet nozzle
circumferential gap
horizontal alignment
© by LOESCHE GmbH
Fan Inspection
Inlet nozzle Attention: different values for cold and hot condition, left and right,
top and bottom!
© by LOESCHE GmbH
3
Agenda
Fan Inspection
Pressures and Calculations
Measurements
Efficiency Calculation
© by LOESCHE GmbH
Rev.1 - 13/11/2010 13/10/2011 10
Pressures
Static, dynamic and total pressure
+ =
ps + pd = pt
© by LOESCHE GmbH
kg m² kg
Pa+ ⋅ = = Pa
m³ s² m⋅ s²
Rev.1 - 13/11/2010 13/10/2011 11
Pressures
Total static pressure
+ =
pa + ps = pst
© by LOESCHE GmbH
Ambient pressure available in decent laboratory or weather station near to plant site (internet).
Standard (DIN 1343) ambient pressure = 101325 Pa.
Pa + Pa = Pa
Rev.1 - 13/11/2010 13/10/2011 12
4
Calculations
Gas density
/ (R * T) = ρ
pst / (R*T) = ρ
© by LOESCHE GmbH
J
R(air)=287,1 kg ⋅ K
Pa ⋅ kg ⋅ K N ⋅ kg ⋅ K kg
= =
J ⋅K m² ⋅ N ⋅ m ⋅ K m³
Calculations
Gas velocity
As dynamic pressure = pd = (ρ/2)*v2
/ ρ = v
Sqrt ((2pd) / ρ) = v
Pa ⋅ m³ N ⋅ m³ kg ⋅ m ⋅ m³ m² m
= = = =
kg m² ⋅ kg m² ⋅ kg ⋅ s ² s² s
Calculations
Volume flow
.
v * A = V
v * A = volume flow
.
v*A= V
© by LOESCHE GmbH
m ⋅m² m³
=
s s
Rev.1 - 13/11/2010 13/10/2011 15
5
Calculations
Δ p total
2 – 1 + 2 – 1 = Δpt
© by LOESCHE GmbH
Index 1 = fan inlet
Index 2 = fan outlet
Pa= Pa
Rev.1 - 13/11/2010 13/10/2011 16
Calculations
Hydraulic power vs. power at shaft
.
Δpt *V = hydraulic power Pel * ηmech = Power at shaft
Δpt *V
.=P
h Pel * ηmech = Pmech
Agenda
Fan Inspection
Pressures and Calculations
Measurements
Efficiency Calculation
© by LOESCHE GmbH
6
Measurements
What and how to measure?
To be measured: By:
Ambient pressure Barometer
Static pressure Pitot static tube/Prandtl
Dynamic pressure (S-Type)
Temperature (Anemometer)
PT100
© by LOESCHE GmbH
Source: www.electro-mation.de and http://www.testo.de/view/product/de/05604160/testo-416
Agenda
Fan Inspection
Pressures and Calculations
Measurements
Efficiency Calculation
© by LOESCHE GmbH
Measurements
What and how to measure?
Location of measurement:
Laminar flow required for measurement
Strait duct portion: Tree up to five times of diameter (depending on source) up- and
down-stream of measurement location
Near inlet AND near outlet of fan
Other Requirements:
grid-point measurement
Fan running at/around nominal load
No changes during measurement/stable operation
© by LOESCHE GmbH
To be considered:
Preparation time around three days. + Measurement around three hours. + Calculation
and report around two days. = Minimum five days!
7
Efficiency Calculation
What to consider for calculation?
Grit-point measurement:
Two different possible arrangements –
1. variaton of measurement points
2. Calcualtion of measured cross sections
Are used to equalise the measured values for average figures.
Order of calculations:
1. total static pressure (pst) at all points
2. density at all points
3. velocity at all points
4. average velocity and density according to weight of cross section
5. Volume flow
6. Δ p total
7. Hydraulic power of fan
© by LOESCHE GmbH
Calculation of fan efficiency:
Ph
ηf =
Pmech
Rev.1 - 13/11/2010 13/10/2011 22
Efficiency Calculation
Example:
1 2 3 4 5 6 crosssection
p_d(left) 464 461 443 449 447 443 3,0728m
p_d(right) 434 458 436 433 425 410 3,0728m
p_d(out) 1792 2249 2141 1344 2239 2175 3,120356m
Ambient 95913
© by LOESCHE GmbH