Example of ANSI inspection plan.

A given characteristic is inspected per the following plans for a 3000 units lot.

Using ANSI/ASQ Z1.4, Level I 0.65% AQL


Letter H
Normal inspection: 80
Tightened inspection: 125
Reduced: 32
Using ANSI/ASQ Z1.4, Level S-1 0.65% AQL
Letter C
Normal inspection: 20
Tightened inspection: 32
Reduce:8