Download as pdf
Download as pdf
You are on page 1of 4
Issue: Jun 02/89 COMPONENT MAINTENANCE SHEET No. | Date REVISIONS CHECK-VALVE service | No. | Date BULLETIN 1. Manufacturer ABG-SEMCA S.A. P/N 41063E01 408, Avenue des Etats-Unis B.P. 2010 31016 TOULOUSE Cedex FRANCE, cHamrer 7 (0.03 man a5) 4.50.2 (0.169 190.185 in) 510.186 int 655002 2577 02579in) 7 VERTICAL AXIS —— Net i Check-Valve Figure 1 21-26-30 INSTALLATION Position © ——+ 12.380 to 2.3580.) 19.205 (0.736 100.775 ind T (076 100267 mil '@ ABG-SEMCA TP1 Page 1 Jur 02/89 © ABG-SEMCA COMPONENT MAINTENANCE SHEET 41063E01 A. The check valve fitted to a line admits the air supply downstream the air conditioning system and prevents reverse flow if the fluid supply is interrupted B. The check valve consists of a cylindrical body supporting a spindle complete with two pivoting flaps. Flaps are kept against their seat machined on body by a return spring C. For attachment, check valve body is machined with a flanged end. 3. Technical Data A. Dimensions Refer to figure 1. B. Weight 0,058 kg (0.127 1b). Cc. Pressures - Working flu:d : air. - Max. operating pressure : 3 bar (43.5 psig) - Min. opening pressure : less than 2,7 mb (0.04. psig) - Max. leakage : 10 1/min with 496 mb (7.2 psig) upstream pressure. - Max. pressure drop : 12,11 mb (0.175 psig) with 10 kg/min (22.046 1b/min) at 20°C (68°F) and 2 bar abs. (29 psia) D. Temperatures Operating temperatures : -40°C to +200°C (-40°F to +362°F) 4. Maintenance A. On aircraft : not applicable. B. Repair : if damaged, unit will be replaced by a new one. 5. Cleaning Clean unit using an approved chlorinated solvent (trichloroethane (OT620C and/or MIL-T-81533/A) . 21-26-30 sun 08789 6. 1 Test A. Func! © ABG-SEMCA COMPONENT MAINTENANCE SHEET 41063E01 tional Check Visually check unit. Then, with its axle in the vertical position, check flaps move freely and check they are returned by spring into their closing position B. Inte! qa) (2) Storage nal Leakage Test (Ref. Fig. 2) Test equipment Use a test set-up including the following elements : - a pressure gage capable of reading a 1 bar (14.5 psig pressure, a flowmeter for a 2 1/min to 20 1/min (0.0704 cu.£t/min to 0.704 cu.ft/min) reading, a shut-off valve, - a pressure source delivering 500 mb (7.25 psig) with a 10 1/min (0.352 cu.ft/min) airflow, a sealed test box made up of two half-shells fixed by a clamp. Test method (a) Apply a 496 mb (7.2 psig) test pressure downstream non-return valve, read on pressure gage (b) Check leakage read on flowmeter does not exceed 10 L/min (0.352 cu.ft/min) . A. General (1) Pack unit according to the ATA 300, class 2, standard (2) No special storage conditions required B. Storage Life over 10 years. C. Destorage Unpack unit : perform a visual check. 21-26-30 26d Jun 02/89 © ABG-SEMCA COMPONENT MAINTENANCE SHEET 41063E01 SHUT OFF VALVE PRESSURE GAGE ain pressure —rEsT 80x P cranl FLOWMETER PREFORMED PACKING ‘CHECK VALVE Internal Leakage Test Figure 2 21-26-30 Paae,s Jun 02/89

You might also like