Professional Documents
Culture Documents
Article 2
Article 2
ABSTRACT
Aim: this study was to determine influence of different restorative protocols on fracture
resistance of maxillary premolars with MOD cavities.
Materials & Methods: three direct resin-based composites were used in this study; sonically
activated bulk-fill resin composite (Sonic-fill TM Kerr, USA), short fiber-reinforced composite,
everX-Posterior (G.C., Tokyo, Japan), and nanoceramic resin-based composite, Ceram.X® one
(DENTSPLY, Germany). An indirect CAD/CAM composite block Grandio Blocs (VOCO GmbH,
Germany) was also used. Sixty extracted maxillary premolars were collected. According to
restorative protocol tested, premolars were randomly divided into six groups (ten each) and stored
at room temperature in distilled water containing 0.2% sodium azide for three months.
Results: One-Way ANOVA followed by Tukey’s post-hoc test showed a statistically significant
difference between study groups (P < 0.001). The positive control, Grandio blocs (IGG), and
Ever-X- posterior (BEG) groups yielded the significantly highest mean values for maximum load.
The mean value of the Sonic-fill (BSG) group did not differ from those of the IGG and BEG groups.
Ceram-X-one (NCG) group had a substantially lower mean value than the positive control, IGG,
BEG, and BSG groups, but a greater mean value compared to the negative control group. The
negative control produced the lowest mean value among all study groups.
Conclusion: The current results illustrated that the fracture resistance of maxillary premolars
with MOD cavities is highly dependent on the restorative material used. Accordingly, by selecting
the suitable restorative material, the restored tooth can be reinforced to a level comparable to that
of a sound tooth.
Clinical significance: Establishing a standard restorative protocol and evaluating the efficacy
of restorative materials used to repair deficient with variable remaining tooth structure to improve
their fracture resistance under occlusal load.
KEYWORDS: fracture resistance, bulk fill resin composite, fiber reinforced composite,
nano-ceramic resin composite
* Lecturer of Restorative Dentistry, Faculty of Dentistry, The British University in Egypt, Cairo, Egypt
Sonic-fill TM Nanohybrid Matrix: Glass, oxide, chemicals (10–30%), 3-trimethoxysilyl- Kerr Corp,
bulkfill composite propyl methacrylate (10–30%), silicon dioxide (5–10%), ethox- Orange, CA,
material ylatedbisphenol A dimethacrylate (1–5%), bisphenol A bis (2-hy- USA
droxy-3- methacryloxypropyl) ether (1–5%), and TEGDMA
(1–5%)
Filler: 83.5 % by weight
EverX-Posterior Short-fiber Resin matrix: Semi-interpenetrating polymer network (semi- GC, Tokyo,
reinforced resin IPN): netpoly (methyl meth’acrylate)-inter-net-poly (bis-glycid- Japan
composite yl- A-dimethacrylate): Bis-GMA, TEGDMA, and PMMA
Fillers: E-glass fiber, barium borosilicate
Grandio Bloc Nano-ceramic 86% Nanohybrid Filler 14% UDMA+ DMA VOCO GmbH,
hybrid CAD / CAM Germany,
composite Cuxhaven
TABLE (2): Mean ± S.D. and P-value for the effect restorative material and tooth interface and the po-
of restoration type on fracture resistance tential to support the fragile and unsupported tooth
of MOD cavities in maxillary premolars structure. (20, 21) There are contradictory opinions re-
(Newtons). garding the most suitable restorative materials for
restoring these teeth and achieving this goal. In the
Maximum load present study, different restorative materials sys-
Restoration type
(Newtons) tems were used to restore MOD cavities in maxil-
Sound Teeth (Positive Control) 992.84 ± 117.16a lary premolar teeth, and their fracture resistance
MOD Cavity (Negative Control) 459.52 ± 90.66d
was evaluated.
randomly dispersed in numerous directions within a and visible cracks, so as not to affect the inherent
semi-interpenetrating resin matrix. (9) fracture resistance of the tooth structure. Moreover,
Furthermore, one Nano-ceramic, which is rec- premolars in this study received MOD cavity design
to weaken the remaining tooth structure and increase
ommended for incremental packing technique,
the risk of cuspal fracture.
was selected to be compared to the two bulk-fill
composite materials evaluated in this study to ana- The cavity widths were also standardized to be
lyze both the incremental and bulk-fill placement within 5% of one another to standardize the amount
techniques. Ceram.X® one composite is a nanoc- of remaining tooth structure that consequently af-
eramic composite composed of a combination of fects the fracture resistance of the restored teeth. On
conventional filler (1 μm), nanofillers (10 nm), the other hand, the cavity depth was chosen to be 4
and, most importantly, organically modified ce- mm to evaluate the manufacturers’ claim of apply-
ramic nanoparticles (2-3 nm). This combination of ing bulk-fill composite up to 5 mm in one step. (28, 29)
fillers based on nanoceramic technology has posi- According to the monoblock concept, a monob-
tively improved the mechanical properties of this lock unit can bond strongly to available interfaces
material. (24) and the substrate. The successful binding effect of
On the other hand, an indirect CAD\CAM com- the adhesive joint that brings tooth structure togeth-
posite restorative material was selected to be com- er helps in favorable stress distribution and higher
pared to the previously mentioned direct composite fracture resistance. Accordingly, the adhesive,
materials to have more comparable data between which the manufacturer recommends for each tested
direct and indirect restorative protocols in restoring resin-based composite material, was used to provide
MOD cavities in upper premolar teeth. Moreover, it the required monoblock restoration to successfully
was reported that the modulus of elasticity of resin function as a mechanically homogenous unit.
composite CAD/CAM blocks is close to that of The more accurately a test simulates the
enamel and dentine when compared to CAD/CAM clinical condition, the more likely the results are
ceramic blocks, implying that resin composite clinically relevant. Adding moisture and controlled
CAD\CAM blocks are closer to the tooth structure temperature to the environment is important when
stiffness, leading to higher flexibility and fracture measuring the fracture resistance of direct resin-
toughness of those type of blocks. (25) Grandio blocs based composites. That is why thermocycling wad
are nano-hybrid composite CAD/CAM blocks that performed for all the restored specimens.
contain 86 % wt. inorganic fillers in a polymer ma-
All the restored groups showed lower fracture
trix and 14% UDMA+DMA. They are recommend-
resistance mean values than the intact sound group
ed for the fabrication of inlays and onlays restora-
(positive control group) in this study. It could be
tions. Grandio blocs were chosen for their higher
attributed to the inability of available restorative
filler loading. (26)
materials to fully restore lost mechanical properties,
In this study, maxillary premolar teeth were which might result from the heterogeneity between
chosen to be evaluated because they were reported the tooth structure and the restorative material,
to be the second most prone teeth for vertical multiple interfaces, and all faced challenges during
fractures due to their complex anatomy. (27) All adhesion. (30, 31) On the other hand, regardless of the
premolars used in this study were extracted from resin-based composite material used, all restored
patients aged 15 to 30 years old, and examined groups had significantly greater mean values for
using 10X magnification, were free from caries substantial fracture resistance mean values than the
(1914) E.D.J. Vol. 6, No. 2 Radwa Nagy Ahmed and Hend S. Ahmed
prepared but unrestored teeth (negative control). It a reduction in the frequency and size of critical
could prove that adhesive restorations could partially voids. Sonicfill resin exhibits a low polymerization
restore the lost tooth stiffness. 32 The findings of this shrinkage of only 1.6%, decreasing gap formation
study have shown that CAD/CAM composite blocks, and the risk of cracking that leads to fracture. (37)
short fiber-reinforced composite, and sonic fill bulk-
Although both Ever X posterior and Ceram.X®
fill composite yielded much higher maximum load
one composites had filler loadings of 77% and 76%
mean values than Ceram.X® one. In contrast, these
wt, respectively, the results of this study showed
groups revealed no significant difference between
that Ceram X had the lowest significant fracture
each other. Thus, the null hypothesis was rejected
resistance mean values. It could be because their
because the different restorative protocols did affect
chemical compositions are diverse.
the fracture resistance.
Ever X posterior containing E-glass fibers of 1–2
According to the literature review, it was reported
mm in length impregnated within the nanohybrid
that both filler loading and the elastic modulus of
composite could be used in 4 mm increment.
the restorative material are considered key factors
The e-glass fibers presented in EverX post short
affecting mechanical properties of composites.
fiber-reinforced composites enhance the fracture
The variation in strength between different resistance of restored teeth through transferring the
composites may be explained due to the differences subjected stresses from the resin polymer matrix to
in the chemical composition of their matrix, filler the fibers, hence preventing the crack propagation.
content, filler size, and loading. The increase in the Moreover, the e-glass fibers are incorporated in this
filler loading is directly proportional to an increment resin composite in a random orientation, reinforcing
in fracture and compressive strength. (33, 34) The filler the restoration in multiple directions and enhancing
loadings of the Grandio blocs and Sonic-fill were its strength.38
found to be within the same range of 86% and
83% wt, respectively, which may explain why the On the other hand, Ceram.X® one RBCs can be
fracture resistance mean values did not differ much considered a Nanoceramic composite with pre-po-
between them. Moreover, it was revealed that the lymerized fillers (a trimodal resin composite) based
filler weight percentages of CAD/CAM composite on the modified version of the polysiloxane matrix.
blocks have a considerable role in mechanical The filler system is a blend of three different filler
properties than their microstructural constituents types: the spherical, pre-polymerized SphereTEC™
do. Further, CAD/CAM composites combine the fillers (≈15 μm), non-agglomerated bariumalumin-
strength of ceramic blocks with a lower modulus ium- borosilicate glass fillers (1.1- 1.5 μm), and
of elasticity of composite, resulting in a reduced meth-acrylate functionalized silicone dioxide nano-
hardness that may also explain the higher fracture filler (10 nm).
resistance of Grandio blocs in this study. (35,36) Ceram.X® one RBCs compositions with a lower
According to the manufacturer, Sonic activation filler loading may have a lower significant fracture
significantly reduces the viscosity of the SonicFill™ resistance due to incorporating pre-polymerized
composite dramatically up to 87%. It can be due filler particles. Traditionally, mechanical properties
to the presence of special rheological modifiers are generally inferior with resin composite materials
that react to sonic activation delivered through containing pre-polymerized particles. It may be
the SonicFill™ handpiece during its placement, owing to the unfavorable stress transfer between the
leading to better adaptation to the cavity walls and resin matrix and filler particles. (39, 40)
FRACTURE RESISTANCE OF MOD CAVITIES IN MAXILLARY PREMOLAR TEETH RESTORED (1915)
All authors declare no conflict of interests. 12. Santana FR, Pereira JC, Pereira CA, Fernandes Neto AJ,
Soares CJ. Influence of method and period of storage on
the microtensile bond strength of indirect composite resin
REFERENCES restorations to dentine. Braz Oral Res. 2008;22(4):352-
1. Plotino G, Buono L, Grande NM, Lamorgese V, Somma 357. http://www.ncbi.nlm.nih.gov/pubmed/19148392.
F. Fracture resistance of endodontically treated molars re- 13. Humel MMC, Oliveira MT, Cavalli V, Giannini M. Ef-
stored with extensive composite resin restorations. J Pros- fect of storage and disinfection methods of extracted bo-
thet Dent. 2008;99:225-232. vine teeth on bond strength to dentin. Brazilian J Oral Sci.
2. Sarabi N, Taji H, Jalayer J, Ghaffari N. Fracture Resistance 2007;6(22):1402-1406.
and Failure Mode of Endodontically Treated Premolars 14. Soares CJ, Pizi ECG, Fonseca RB, Martins LRM. In-
Restored with Different Adhesive Restorations. JDMT. fluence of root embedment material and periodon-
2015;4(1):13-20. tal ligament simulation on fracture resistance tests.
3. Kaisarly D, Gezawi M El. Polymerization shrinkage assess- Braz Oral Res. 2006;19(1):11-16. doi:10.1590/s1806-
ment of dental resin composites: a literature review. Odontol- 83242005000100003.
ogy. 2016;104(3):257-270. doi:10.1007/s10266-016-0264-3. 15. Alshiddi IF, Aljinbaz A. Fracture resistance of endodonti-
4. Jarisch J, Lien W, Guevara PH, Greenwood WJ, Dunn cally treated teeth restored with indirect composite inlay
WJ. Microcomputed tomographic comparison of posterior and onlay restorations – An in vitro study. Saudi Dent J.
composite resin restorative techniques: Sonicated bulk fill 2016;28(1):49-55. doi:10.1016/j.sdentj.2015.09.001.
versus incremental fill. Gen Dent. 2016;64(5):20-23.
16. Fahad F, Majeed MA-R. Fracture Resistance of Weakened
5. Frankenberger R, Zeilinger I, Krech M, et al. Stability of Premolars Restored with Sonically - Activated Compos-
endodontically treated teeth with differently invasive res- ite, Bulk - Filled and Incrementally - Filled Composites:
torations: Adhesive vs. non-adhesive cusp stabilization. A Comparative in Vitro Study. J Baghdad Coll Dent.
Dent Mater. 2015;31(11):1312-1320. doi:10.1016/j.den- 2014;26(4):22-27. doi:10.12816/0015250.
tal.2015.08.160.
17. PRICE(d) FARMGCAGARBT, (a). Light curing in den-
6. Goracci C, Cadenaro M, Fontanive L, et al. Polymer- tistry and clinical implications: a literature review Polym-
ization efficiency and flexural strength of low-stress erization. Braz Oral Res. 2017;31(61):64-91.
(1916) E.D.J. Vol. 6, No. 2 Radwa Nagy Ahmed and Hend S. Ahmed
18. Gale MS, Darvell BW. Thermal cycling procedures 30. VIANNA ALS de V, PRADO CJ do, BICALHO AA,
for laboratory testing of dental restorations. J Dent. PEREIRA RA da S, NEVES FD das, SOARES CJ. Ef-
1999;27(2):89-99. doi:10.1016/S0300-5712(98)00037-2. fect of cavity preparation design and ceramic type on the
19. Wu Y, Cathro P, Marino V. Fracture resistance and pat- stress distribution, strain and fracture resistance of CAD/
tern of the upper premolars with obturated canals and re- CAM onlays in molars. J Appl Oral Sci. 2018;26:1-10.
stored endodontic occlusal access cavities. J Biomed Res. doi:10.1590/1678-7757-2018-0004.
2010;24(6):474-478. doi:10.1016/S1674-8301(10)60063-2. 31. 31. Suksaphar W, Banomyong D, Jirathanyanatt T,
20. Mergulhão V, de Mendonça L, de Albuquerque M, Braz R. Ngoenwiwatkul Y. Survival rates against fracture of end-
Fracture Resistance of Endodontically Treated Maxillary odontically treated posterior teeth restored with full-cov-
Premolars Restored with Different Methods. Oper Dent. erage crowns or resin composite restorations: a systematic
2019;44(1):E1-E11. doi:10.2341/17-262-l. review. Restor Dent Endod. 2017;42(3):157. doi:10.5395/
rde.2017.42.3.157.
21. Bilal H. Ibrahim HJA-A. Fracture Resistance of Endodon-
tically Treated Premolar Teeth with Extensive MOD Cavi- 32. Ástvaldsdóttir Á, Dagerhamn J, Van Dijken JWV, et al.
ties Restored with Different Bulk Fill Composite Restora- Longevity of posterior resin composite restorations in
tions (An In vitro Study). J Bagh Coll Dent. 2017;29(2):26- adults - A systematic review. J Dent. 2015;43(8):934-954.
32. doi:10.14744/eej.2018.70299. doi:10.1016/j.jdent.2015.05.001.
22. Van Ende A, De Munck J, Diogo /, Lise P, Meerbeek B 33. Habib E, Wang R, Zhu XX. Correlation of resin viscos-
Van. Bulk-Fill Composites: A Review of the Current Lit- ity and monomer conversion to filler particle size in den-
erature. J Adhes Dent. 2017;19(2):95-109. doi:10.3290/j. tal composites. Dent Mater. 2018;34(10):1501-1508.
jad.a38141. doi:10.1016/j.dental.2018.06.008.
23. Didem A, Gözde Y, Nurhan Ö. Comparative Mechani- 34. Kyo-Han Kim, MS, PhD,a Joo L. Ong, MS, PhD,b and
cal Properties of Bulk-Fill Resins. J Compos Mater. Osamu Okuno, MS P. The effect of filler loading and mor-
2014;4:117-121. phology on the mechanical properties of contemporary
24. Patel CJMPPDP. Comparative Analysis of Fracture Resis- composites. J Prosthet Dent. 1992;87(6).
tance of Maxillary Premolars with Class II MOD Cavities 35. Grzebieluch W, Mikulewicz M, Kaczmarek U. Resin
Restored with Novel Nanocomposites Including Fibre Re- Composite Materials for Chairside CAD/CAM Restora-
inforced Composite Restorative System: A Step Ahead in
tions: A Comparison of Selected Mechanical Properties. J
Composite Dentistry. Adv Hum Biol. 2014;4(2):14-21.
Healthc Eng. 2021;8:882-895. doi:10.1155/2021/8828954.
25. Alamoush RA, Silikas N, Salim NA, Al-Nasrawi S, Sat-
36. Shereen Hafez, Amir Hafez HA and HAA. Effect of Dif-
terthwaite JD. Effect of the Composition of CAD/CAM
ferent Filler Loading on Fracture Resistance of Cad/Cam
Composite Blocks on Mechanical Properties. Biomed Res
Resin Composite Restoration In Premolar Teeth: An In Vi-
Int. 2018;10. doi:10.1155/2018/4893143.
tro Study. Egypt Dent J. 2019;65(1:9):2457-2465.
26. Voco, Germany scientific compendium, 2021, Grandio
37. Manchester M. Post-cure depth of cure of bulk fill den-
Blocs.
tal. Dent Mater. 2013;30(2):149-154. doi:10.1016/j.den-
27. Emamieh S, Hojati P, Ghasemi A, Torabzadeh H. Effect of tal.2013.10.011.
cusp coverage and water storage on compressive strength
of composite restorations of premolars. J Clin Exp Dent. 38. Jafarnia S, Valanezhad A, Shahabi S, Abe S, Watanabe
2018;10(4):2-6. doi:10.4317/jced.54668. I. Physical and mechanical characteristics of short fiber-
reinforced resin composite in comparison with bulk-fill
28. Nazari A, Bajaj D, Zhang D, Romberg E, Arola D. Ag- composites. J Oral Sci. 2021;63(2):148-151. doi:10.2334/
ing and the reduction in fracture toughness of human josnusd.20-0436.
dentin. J Mech Behav Biomed Mater. 2009;2(5):550-559.
doi:10.1016/j.jmbbm.2009.01.008. 39. Dentsply, DeTrey, Scientific Compendium 2016 for Ceram
Universal Nano-Ceramic Restorative.
29. Mollaverdi F, Bassir M, Labibzadeh A. The effect of
amount of lost tooth structure and restorative technique 40. Blackham JT, Vandewalle KS, Lien W. Properties of Hy-
on fracture resistance of endodontically treated premo- brid Resin Composite Systems Containing Prepolymer-
lars. J Conserv Dent. 2015;16(5):413. doi:10.4103/0972- ized Filler Particles. Oper Dent. 2009; 34(6):697-702.
0707.117494. doi:10.2341/08-118-l