Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Avionics

IFR 6000 Ramp Test Set

The IFR 6000 is a compact, lightweight and weatherproof unit designed for testing transponder
modes A/C/S, TCAS I and II as well as DME.

• One main user screen for each test mode


• Detachable antenna
• Large display
• Simple user interface
• Lightweight and compact <8 lbs. (3.6 kg)
• Battery 6 hours plus duration
• Fully FAR part 43 appendix F compliant
• European Elementary and Enhanced
Surveillance

The IFR 6000 features an extremely easy to use


interface where every parameter the user com-
monly needs to view is displayed on screen.
Controls
Dedicated Mode keys for XPDR, DME and TCAS
allow quick selection of the operational mode.
Operational Modes
The application dependant softkeys and data
Each operational mode has one main user screen. The operational
select/slew keys provide an intuitive man machine
modes are:
interface.
XPDR (Sub-Modes: ADS-B MON, ADS-B GEN & GICB)
DME mode is provided with dedicated keys for
frequency/channel selection and RF level control. DME
For frequently varied parameters in DME and
TCAS 1, 2 (Sub-Modes: TIS)
TCAS modes, such as Range and Rate, dedicated
keys are provided. Most tests can be completed without leaving the main user screens.
This simplifies the line technician's testing task.

For the very latest specifications visit


XPDR - AUTO TEST P AS S BAT 2.5 Hr BAT 2.5 Hr
XP DR - CO NF IG

C O N F IG :G E N E R IC M O D E S LEVEL=4 1 G E N E R IC A T C R B S
A N TE N N A : B O TTO M 2 A TC R B S C LA S S A
REPL IE S =A,C,S FREQ =1090.12 MHZ 3 A TC R B S C LA S S B
TOP ERP =57.1 dBm MTL = -74.0 dBm 4 G E N E R IC M O D E S
BOT ERP =56.0 dBm MTL = -73.1 dBm 5 M O D E S C LA SS A
A CODE =1234 C AL T =35000 ft 6 M O D E S C LA SS B
S CODE =1234 S AL T =3500 0 ft 7 M O D E S C L B O PT FR EQ
T AIL =N12345 DF17 DETEC TED=NO 8 M O D E S C L B O PT PW R
F L T ID =AA -50 AA=AC3 421(5303204 1)
F S =5 – NO AL ERT SPI IN AIR
VS=IN AIR COUNTRY=United States

RUN TEST SELECT


TEST LIST CONFIG A NT INFO RETURN

Mode S and ATCRBS Transponder User selects config required for test.
XPDR Auto-Test: If the class of the transponder is unknown, the generic config may be
Every parameter the user commonly needs to view is displayed on one selected which applies to the widest limits.
screen. The test set will automatically determine the Mode S transponder
The auto-test performs all tests defined by FAR Part 43 Appendix F, level.
including the proposed Eurocontrol additional tests. The selected config parameters may be displayed by pressing the
The tests are tailored automatically according to reported transpon- INFO softkey.
der level to avoid erroneous failures. Eight predetermined configs are provided to meet the currently field-
ed transponder test needs.
XPDR – T EST LIST B AT 2.5 Hr
XPDR – ELEMENT SU R V1 P AS S B AT 2.5 Hr
1 A /C D E C D R /S L S - PA SS
2 A /C F 1 /F 2 S P A C E /W ID T H - PA SS B D S = 1 ,0 SU B N ETW O R K VER =1
3 P O W E R /F R E Q - PA SS E N H P R O T IN D = L V L 2 -4
4 S A L L -C A L L - PA SS SPEC SER V C A P =Y E S
5 S R E P L Y T IM IN G - PASS U E L M C A P A B IL IT Y = 1 6 /1 s
6 S R E PLY - PA SS D E L M C A P A B IL IT Y = 1 6 /5 0 0 m s
7 U F0 - PA SS A IR C R A F T ID C A P = YES
8 U F4 - PA SS S U R V ID E N T C A P =Y E S
9 U F5 - PA SS C O M M U S E G IC B R E P = 1
10 U F 11 - PA SS D TE =Y E S
11 U F 16 - PA SS C O N T FLA G =Y E S
12 U F 20 - PA SS S Q U IT T E R C A P =Y E S

SELECT NEXT
TEST PAGE RETURN
RUN PREV NEXT
TEST TEST TEST RETURN

The test list is selected from the auto-test screen. This provides an
easy means of selecting any of the individual tests that comprise the
XPDR– EL EMENT SUR V2 P AS S B AT 2.5 Hr
auto-test.
B D S = 1 ,7 :0 ,5 :0 ,6 :0 ,7 :0 ,8 :0 ,9
Tests on the 2nd screen (not shown) include: :0 ,A :2 ,0 :2 ,1 :4 ,0 :4 ,1 :4 ,2 :4 ,3
:4 ,4 :4 ,5 :4 ,8 :5 ,0 :5 ,1 :5 ,2 :5 ,3
:5 ,4 :5 ,5 :5 ,6 :5 ,F :6 ,0
13 UF21 B D S 1 ,8 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0
B D S 1 ,9 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0

14 UF24 B D S 1 ,A = 0 0 0 0 0 0 0 0 0 0 0 0 0 0
B D S 1 ,B = 0 0 0 0 0 0 0 0 0 0 0 0 0 0
B D S 1 ,C = 0 0 0 0 0 0 0 0 0 0 0 0 0 0
15 ELEMENTARY SURVEILLANCE 1 B D S = 2 ,0
B D S = 3 ,0
F L IG H T ID = U A 6 6 1
A R A = 111010 10000000 R A C = 101 0
R A T=0
16 ELEMENTARY SURVEILLANCE 2
RUN PREV NEXT

17 ENHANCED SURVEILLANCE TEST TEST TEST RETURN

0 XPDR – A/C SPAC/WDT H F AI L B AT 2.5 Hr The Eurocontrol Elementary Surveillance DAP's (Downlink Aircraft
Parameters) are displayed on two screens.
F 1 W ID T H ·  A = 0 .3 0 0 u s C = 0 .4 5 0 u s
F 2 W ID T H A = 0 .4 0 0 u s  C = 0 .6 0 0 u s
F 1 -F 2 A = 2 0 .3 0 0 u s C = 2 0 .3 0 0 u s
XPDR – ENH ANC ED SUR V P AS S B AT 2.5 Hr
R E PLY D ELA Y A = 3 .0 5 u s  C = 3 .5 5 u s
R E PLY J IT T E R A = 0 .2 5 0 u s C = 0 .0 0 0 u s
R E PLY R A T IO A = 100 % C = 10 0% B D S 4 ,0 M C P /F C U S E L A L T = 6 5 5 2 0 ft
-8 1 d B m R E P L Y R A T IO A =0% C =0% B A R O PR ES SET =
B D S 5 ,0 R O LL A N G LE = 4 0 .1 d e g
A T C R B S A L L -C A L L A =P A S S C =P A S S T R U E T R A C K A N G L E = 9 0 .3 d e g
G R O U N D SPEED = 5 1 2 k ts
P U LS E A M P V A R A = 0 .0 d B C = 0 .0 d B TR A C K A N G LE R A TE = 4 .0 0 d e g /s
T R U E A IR S P E E D = 5 1 2 k ts
RUN PREV NEXT B D S 6 ,0 M A G N E T IC H E A D IN G = 1 8 0 .3 d e g
TEST TEST TEST RETURN IN D A IR S P E E D = 5 1 2 k ts
M ACH NO = 0 .3 0 0
IN E R T V E R T V E L = -1 4 0 0 ft/m in
B A R O A LT R A TE = -1 4 0 0 ft/m in

Individual tests may be reviewed for failures which are identified by RUN PREV NEXT
TEST TEST
an arrow symbol. TEST RETURN

Eurocontrol Enhanced Surveillance DAP’s are displayed on one


screen.
T CAS BAT 2.5 Hr
SCENARIO: 0 - CUSTOM
T CAS T YP E:T CAS II %RE PLY: 100
XPDR - UFO P AS S BAT 2.5 Hr INTRUDER TYPE:MODE S
RANG E ST ART : 10.00 nm STOP: 0.00 nm
RANG E RAT E : 350 kts
DF = 0 AL T ST ART : +10 00 ft STOP: 0 ft
VS = 0 – IN AIR AL T RAT E : 600 fpm CONVERGE :OFF
CC = 0 – NOT SUPPORTED UUT AL T : 3 1200 ft AL T DET ECT : O N
SL = 0 – NO TCAS SENS LEVEL REPORTED FREQ= 1030.000 MHz ERP= 57.0 dBm
RI = 12 – AIRS P EE D 301 T O 600 KNO T S RANGE= 21.00 nm IN ALT= +1000 ft Ð
T CAS ST AT US= T RACKING
ST AT US = NO N - T HRE AT ENCOUNTER= 0: 00
AC = 03 A0(016 40) 1 0700 FT
MO DE C AL T CO MP ARE = P AS S
AA = AC3421(5 3032041)
RUN PREV NEX T STORE/
DF 11 ADDRESS COMPARE = PASS TEST PARAM PARAM MON RECALL

RUN PREV NEX T


TEST TEST TEST RETURN
TCAS
TCAS types…
No more HEX data field interpretation!
TCAS 1 MODE C
All Mode S Format tests display parameter in engineering units.
TCAS 2 ATCRBS
XPDR– UF11 P AS S BAT 2.5 Hr
TCAS 2 MODE S
DF=11 The Auto-Altitude feature interrogates Mode S XPDR of A/C under
CA=0 - LE VEL
PI = 02F08D
2 CA MODE
test to obtain current altitude.
AA=AC3 421(5303 2041)
II LOCKOUT TIMER=18S
II MAT CH=P AS S
Select pre-stored named scenarios directly from the auto-test screen.
S I L O CKO UT T IMER=18 S
S I MAT CH=P AS S

ADS-B and GICB


RUN PREV NE X T
ADS-B MON: Used to monitor DF17 extended squitter from
TEST TEST TEST RETURN transponders and DF18 extended squitter from 1090 MHz ADS-B
emitters.
Comprehensive II / SI code and lockout timer test ADS-B GEN: Used to generate DF17/DF18 extended squitter, sim-
ulating transponders and 1090 MHz ADS-B emitters.
XPDR – S AL L - C A L L P AS S B AT 2.5 Hr GICB: Used to monitor DAP's (all fields).
IT M R E P L Y
D ELA Y A = 1 2 8 .0 8 u s C = 1 2 8 .0 7 u s
J IT T E R A = 0 .5 1 0 u s C = 0 .5 1 0 u s ADS -B MON DF17 BAT 2.5 Hr
ADDRESS A = 2 A C 421 C = 2 A C 421
1 0,5 AIRBORNE POS - AVAIL
R A T IO A = 100 % C = 100 %
2 0,6 SURFACE POS - NOT CAP
-8 1 d B m A =0% C =0%
3 0,8 IDENT & CAT - AVAIL
4 0,9 AIRBORNE VEL - AVAIL
M O D E S A L L -C A L L = P A S S 5 6,1 A/C ST AT US - AVAIL
ADDRESS = 2A C 421 6 6,2 T ARG ST AT E - AVAIL
T A IL = N 1 2 3 4 5 7 6,3 A/C O P ST AT US - NO SQTR
C O U N T R Y = U n ite d S ta te s

RUN PREV NEXT


TEST TEST TEST RETURN

RUN BDS
TEST DATA RETURN

DME B AT 2.5 Hr

V O R : 1 0 8 .0 0 M H z R F L V L : -2 .0 d B m ADS-B MON:
F R E Q : 978 M H z R A T E : 6 5 0 k ts IN
C H A N : 17X R A N G E:450.00 nm The ADS-B MON LIST shows BDS formats supported.
% R EPLY: 100 ECHO :OFF
SQT R : ON IDENT : OFF The BDS status is annunciated to indicate if the squitter has been
T X FREQ = 1041.0 0 MHZ ER P=5 5.0 d Bm captured, not available or not seen.
P1 WIDT H= 3.50 0 us PRF =150 Hz
P2 WIDT H= 3.50 0 us
P1 - P2 = 3 6.00 us( Y) The BDS DATA key displays the BDS DATA screen for the selected
UUT LVL = -38.2 dBm BDS number.
RUN PREV NEXT STOP
TEST PARAM PARAM RATE IN/OUT

DME
All the user needs are on one screen.
• RF level control for track sensitivity tests
• Supports all DME/TACAN channels selectable in VOR paired
channels
• Full UUT measured parameters are displayed.

For the very latest specifications visit


ADS -B MON BDS 0,5 AVAIL BAT 2.5 Hr
The BDS DATA key displays the BDS DATA screen for the selected
BDS=0,5 AIRBORNE POS TYPE=14
BDS number.
DF1 7 AA=3 AC42 1 (1654 2041) COUNT=1000
ME=00000000000000 PERIOD=DEFAULT
L AT = 37 39 00 N LONG= 97 25 48 W
PO S=G L O BAL S AF =1 T=N/UTC GICB BDS 3,0 AVAIL BAT 2.5 Hr
SURV E IL L ANCE ST AT US = NO INF O
BARO P RES ALT=131025 ft BDS=3,0 ACAS ARA
GNSS ALT = N/A DF2 0 AA=3 AC42 1 (1654 2041)
MB=00000000000000
T IDB= 70 d eg
T IDA= 32000 ft TIDR= 1.00 nm
ARA=11101010000000 TID=3A4518
RAC=1010 RAT =1 MTE=3
T HR E AT ADDRE S S=N/A
T T I=2 - AL T /RANG E/BE ARING DAT A
RUN PREV NEX T
TEST TEST TEST RETURN

ADS-B MON: RUN PREV PREV


TEST TEST TEST RETURN

The BDS DATA screen displays full content of selected BDS format
being received via DF17 or DF18 extended squitters.
GICB:

ADS-B GE N DF17 BAT 2.5 Hr BDS DATA screens display full content of the selected BDS format
1
2
0,5
0,6
AIRBORNE POS
SURFACE POS
- DISABLED
- ENABLED
being received via GICB DF20 or DF21 in RTCA/ICAO engineering
3
4
0,8
0,9
IDENT & CAT
AIRBORNE VEL
- ENABLED
- E NABL E D
units.
5 6,1 A/C ST AT US - ENABLED
6 6,2 T ARG ST AT E - ENABLED
7 6,3 A/C O P ST AT US - ENABLED
T IS BAT 2.5 Hr

T ARG ET S:5 UUT HDG:180 deg


1 2 3 4 5
BRG(deg) : 120 90 234 182 23
RNG(nm) : 6.00 4.00 3.00 2.00 1.00
AL T (ft) : 3500 2000 1000 500 0
RUN BDS BDS AL T RAT E:CL IMB LEVEL LEVEL CLIMB LEVEL
TEST DATA ON RETURN HDG(deg) : 234 178 56 22 0
T RAF F IC : PRO X PROX PROX PROX TRFC

ADDR=3 AC421 (16542 041) N1 2345


The BDS ENABLE/DISABLE key enables or disables the selected TSCR= 5 TSDR= 1
T IS ST AT US =CO NNECT ING
AL T =126700
INFO=0000
ft

BDS number for squittering via DF17 or DF18 extended squitters.


The BDS DATA key displays the BDS DATA screen for the selected RUN PREV NEX T
TEST PARAM PARAM
BDS number.

ADS -B GEN BDS 0,5 BAT 2.5 Hr


BDS=0,5 AIRBORNE POS TYPE: 9
TIS
DF1 7 AA:3 AC421 (1 6542041) COUNT=1000
ME=490844AE8319EA
L AT : 37 39 0 0 N
P ERIO D: 1.00 s
LONG: 97 25 48 W Up to 5 static intruders may be simulated relative to the A/C (UUT).
POS: S AF:1 T:N /UTC
SURV E IL L ANCE ST AT US : NO INF O
BARO P RES ALT:126700 ft General
GNSS ALT : N/A
Radiated Testing:

The IFR 6000 is supplied with a lightweight fully sealed directional


antenna that may be test set mounted, hand held or tripod mounted.
RUN BDS PREV NEX T
TEST OFF PARAM PARAM RETURN
Direct Connect Testing:

ADS-B GEN: The IFR 6000 may be directly connected to the UUT via a supplied
RF coax cable via the RF I/O port.
BDS DATA screens display full content of the selected BDS format in
RTCA/ICAO engineering units.
The NEXT & PREV PARAM keys select data fields for editing via the
data slew keys.

GICB DF20 B AT 2.5 Hr

1 0,5 AIRB ORN E POS - AV AI L


2 0,6 SURF AC E POS - NOT CAP
3 0,7 S Q T R ST AT US - AV AI L
4 0,8 ID E NT & C AT - AV AI L
5 0,9 AIRB ORN E VEL - AV AI L
6 1,0 D AT A L NK C AP - AV AI L
7 1,7 COM GICB CAP - AV AI L
8 1,8 SPEC SER V C AP #1 - AV AI L
9 1,9 SPEC SER V C AP #2 - AV AI L
10 1,A SPEC SER V C AP #3 - AV AI L
11 1,B SPEC SER V C AP #4 - AV AI L
12 1,C SPEC SER V C AP #5 - AV AI L

RUN BDS
TEST DATA RETURN

GICB:
The BDS LIST shows BDS formats supported.
Transit Case: REPLY PULSE SPACING
The IFR-6000 is supplied in a rugged plastic transit case which pro- P1 to P2
vides stowage for the test set, directional antenna, RF coax cable, 12 µs (±100 ns) (X Channel) @ 50% peak
antenna shield, breakout box, and power supply/charger. P1 to P2
30 µs (±100 ns) (Y Channel) @ 50% peak

REPLY PULSE WIDTH


P1/P2
3.5 µs (±0.5 µs)
ECHO REPLY
Control
On/Off
Position
30 nmi (±1 nmi)
Amplitude
-11 dB (±1 dB) relative to reply level
REPLY PULSE RISE AND FALL TIMES
ALL PULSES
Rise Time
2.5 µs (±0.25 µs) (10% to 90%)
SPECIFICATION Fall Time
DME MODE SPECIFICATIONS 2.5 µs (±0.25 µs) (90% to 10%)

SIGNAL GENERATOR REPLY DELAY


A 5-minute warm-up period is required for all specifications. X CHANNEL
Fixed Reply Delay
OUTPUT FREQUENCY 50 µs (±100 ns)
Y CHANNEL
REPLY FREQUENCY
Fixed Reply Delay
Range
56 µs (±100 ns)
962 to 1213 MHz
Accuracy RANGE DELAY
±10 kHz X AND Y CHANNEL
Range
OUTPUT LEVEL
0 to 450.00 nmi
ANTENNA PORT Resolution
Range 0.01 nmi
-67 to -2 dBm at Antenna port Accuracy
Resolution ±0.01 nmi
1 dB
RANGE RATE
Accuracy
X AND Y CHANNEL
±2 dB
Range
Distance to UUT antenna
10 to 6500 kts
6 to 300 ft with supplied antenna
Resolution
RF I/O PORT
1 kts
Range
Accuracy
-115 to -47 dBm
±0.01% typical, tested to ±0.5%
Resolution
1 dB SQUITTER
Accuracy PRF
-95 dBm to –47 dBm ±1 dB 2700 Hz
Accuracy Accuracy
-115 dBm to <-95 dBm ±2 dB ±2%
Distribution
Per ARINC 568

For the very latest specifications visit


REPLY EFFICIENCY INTERROGATION PRF
Range Range
0 to 100% 1 to 300 Hz
Resolution Resolution
1% increments 1 Hz
Accuracy Accuracy
±0.5% ±2 Hz
IDENT TONE TRANSPONDER MODE SPECIFICATIONS
Selection SIGNAL GENERATOR
Selectable three letter code
Frequency RF OUTPUT FREQUENCY
1350 Hz Interrogation Frequency
Accuracy 1030 MHz
±2 Hz Accuracy
±10 kHz
UUT MEASUREMENTS
RF OUTPUT LEVEL
ERP ANTENNA CONNECTOR
Range MTL + 6 dB typical, automatically controlled for a MTL range of -83 to
+47 to +64 dBm -68 dBm
Resolution Range
0.1 dB -67 to -2 dBm at antenna connector
Accuracy Resolution
±2 dB 0.5 dB
Accuracy
DIRECT CONNECTION PEAK PULSE POWER
±2 dB
Range Distance to UUT antenna
+47 to +64 dBm 6 to 200 ft with supplied antenna
Resolution RF I/O CONNECTOR
0.1 dB MTL + 6 dB typical, automatically controlled
Accuracy Range
±1 dB -115 to -47 dBm
FREQUENCY Resolution

Range 0.5 dB

1025.00 to 1150.00 MHz Accuracy

Resolution -95 to –47 dBm, ±1 dB

10 kHz Accuracy

Accuracy -115 to <-95 dBm, ±2 dB

±20 kHz ATCRBS/MODE S INTERROGATION PULSE SPACING


INTERROGATION PULSE WIDTH MODE A
P1 to P2
P1 AND P2 PULSE WIDTHS
2.00 µs (±25 ns)
Range
P1 to P3
2.00 to 5.00 µs
8.00 µs (±25 ns)
Resolution
MODE C
1 ns P1 to P2
Accuracy 2.00 µs (±25 ns)
±50 ns P1 to P3
INTERROGATION PULSE SPACING 21.00 µs (±25 ns)
MODE S
P1 to P2 Spacing
P1 to P2
10 to 14 µs (X Channel)
2.00 µs (±25 ns)
P1 to P2 Spacing
P1 to P6
34 to 38 µs (Y Channel)
3.50 µs (±25 ns)
Resolution P1 to SPR
10 ns 4.75 µs (±25 ns)
Accuracy P5 to SPR
±20 ns 0.40 µs (±50 ns)
INTERMODE INTERROGATION PULSE SPACING INTERROGATION TEST SIGNALS
MODE A MODE S
P1 to P3 PRF
8.00 µs (±25 ns) 50 Hz (±5 Hz)
P1 to P4 ATCRBS
10.00 µs (±25 ns) PRF
MODE C 235 Hz (±5 Hz)
P1 to P3 UUT MEASUREMENTS
21.00 µs (±25 ns)
P1 to P4 ERP (@ 1090 MHZ)
23.00 µs (±25 ns) Range
INTERROGATION PULSE WIDTHS +45.5 to +59 dBm (35.5 to 800 watts)
Resolution
MODE A,C,S,INTERMODE
0.1 dB
P1,P2,P3
Accuracy
0.80 µs (±50 ns)
±2 dB
MODE S
Direct Connection Peak Pulse Power (@ 1090 MHz)
P6 (Short DPSK Block)
Range
16.25 µs (±50 ns)
+46.5 to +59 dBm (45 to 800 watts)
P6 (Long DPSK Block)
Resolution
30.25 µs (±50 ns)
0.1 dB
P5
Accuracy
0.80 µs (±50 ns)
±1 dB
INTERMODE
P4 (Short) TRANSMITTER FREQUENCY
0.80 µs (±50 ns) Range
P4 (Long) 1087.000 to 1093.000 MHz
1.60 µs (±50 ns) Resolution
INTERROGATION PULSE RISE AND FALL TIMES 10 kHz
Accuracy
ALL MODES
±50 kHz
Rise Time
50 to 100 ns RECEIVER SENSITIVITY, RADIATED MTL
Fall Time Range
50 to 200 ns -79 to -67 dBm into 0 dBi antenna
PHASE MODULATION Resolution
0.1 dB
ALL MODES
Accuracy
Transition Time
±2 dB, typical
≤80 ns
Phase Shift RECEIVER SENSITIVITY, DIRECT CONNECTION MTL
180° (±10°) Range
SLS LEVELS -79 to -67 dBm
Resolution
ATCRBS
0.1 dB
SLS Level (P2)
Accuracy
-9 dB, -1 to +0 dB relative to P1 level
±2 dB
0 dB, -0 to +1 dB relative to P1 level
OFF REPLY DELAY
MODE S ATCRBS
SLS Level (P5) Range
-12 dB, -1 to +0 dB relative to P6 level 1.80 to 7.00 µs
+3 dB, -0 to +1 dB relative to P6 level Resolution
OFF 10 ns
Note: SLS level is automatically controlled in the SLS LEVEL test. Accuracy
±50 ns

For the very latest specifications visit


REPLY DELAY, MODE S AND ATCRBS MODE S ALL-CALL PULSE AMPLITUDE VARIATION
Range Range, Mode S (Relative to P1)
125.00 to 131.00 µs -3 to +3 dB
Resolution Range, ATCRBS (Relative to F1)
10 ns -3 to +3 dB
Accuracy Resolution
±50 ns 0.1 dB (0.01 dB via RCI)
Accuracy
REPLY DELAY JITTER
±0.5 dB
ATCRBS
DF 11 SQUITTER PERIOD
Range
0.00 to 2.30 µs Range
Resolution 0.10 to 4.88 sec
Resolution
1 ns
10 ms
Accuracy
Accuracy
±20 ns
±10 ms
MODE S AND ATCRBS MODE S ALL-CALL
Range DIVERSITY ISOLATION
0.00 to 6.00 µs Range
Resolution 0 to >20 dB (Depending on Test Distance)
1 ns Test Distance
Accuracy 1.83 m (6ft) to 28.96 m (95 ft)
±20 ns Resolution
0.1 dB
PULSE SPACING
Accuracy
F1 TO F2 ±3 dB
Range
TCAS MODE SPECIFICATIONS
19.70 to 21.60 µs
Resolution SIGNAL GENERATOR
1 ns
Accuracy
OUTPUT FREQUENCY
±20 ns REPLY FREQUENCY
MODE S PREAMBLE 1090 MHz
Range, P1 to P2 Accuracy
0.8 to 1.2 µs ±10 kHz
Range, P1 to P3 OUTPUT LEVEL (SIMULATED ERP)
3.3 to 3.7 µs
ANTENNA CONNECTOR Note 1
Range, P1 to P4 Radiated power at 0dBi UUT antenna
4.3 to 4.7 µs -68 dBm typical @ 10 Nmi Range, automatically controlled
Resolution Range
1 ns -67 to -2 dBm at Antenna connector
Accuracy Resolution
0.5 dB
±20 ns
Accuracy
PULSE WIDTHS ±2 dB
F1 AND F2 Distance to UUT antenna
6 to 300 ft with supplied antenna
Range
RF I/O CONNECTOR
0.25 to 0.75 µs Automatic mode
Resolution -68 dBm @ 10 Nmi Range, automatically controlled
1 ns Manual mode Range
Accuracy -115 to -47 dBm
±20 ns Resolution
0.5 dB
MODE S PREAMBLE
Range Accuracy

0.25 to 0.75 µs -95 to –47 dBm, ±1 dB


Resolution Accuracy
1 ns -115 to <-95 dBm, ±2 dB
Accuracy
±20 ns
REPLY PULSE SPACING REPLY PULSE AMPLITUDES
MODE C ATCRBS
F1 to F2 ±1 dB relative to F1
20.30 µs (±25 ns) Mode S
F1 to C1 ±1 dB relative to P1
1.45 µs (±25 ns) REPLY PULSE RISE AND FALL TIMES
F1 to A1
ALL MODES
2.90 µs (±25 ns)
Rise Time
F1 to C2
50 to 100 ns
4.35 µs (±25 ns)
Fall Time
F1 to A2
50 to 200 ns
5.80 µs (±25 ns)
F1 to C4 PERCENT REPLY
7.25 µs (±25 ns) Range
F1 to A4 0 to 100%
8.70 µs (±25 ns) Resolution
F1 to B1 10%
11.60 µs (±25 ns) Accuracy
F1 to D1 ±1%
13.05 µs (±25 ns)
REPLY DELAY
F1 to B2
ATCRBS
14.50 µs (±25 ns)
3.0 µs (±50 ns)
F1 to D2
Mode S
15.95 µs (±25 ns)
128 µs (±50 ns)
F1 to B4
17.40 µs (±25 ns) RANGE DELAY
F1 to D4 Range
18.85 µs (±25 ns) 0 to 260 nmi
MODE S Resolution
P1 to P2 0.1 nmi
1.00 µs (±25 ns) Accuracy
P1 to P3 ±0.02 nmi
3.50 µs (±25 ns)
RANGE RATE
P1 to P4
4.50 µs (±25 ns) Range
P1 to D1 -1200 to +1200 kts
8.00 µs (±25 ns) Resolution
D1 to Dn (n=2 to 112) 10 kts
1.00 µs times (n-1) (±25 ns) Accuracy
10%
REPLY PULSE WIDTHS
ALTITUDE RANGE
MODE C
All Pulses Range
0.45 µs (±50 ns) -1000 to 126,000 ft
MODE S Resolution, Mode C
P1 through P4 100 ft
0.50 µs (±50 ns) Resolution, Mode S
D1 through D112 25 ft
0.50 µs (±50 ns), 1 µs chip width ALTITUDE RATE
Reply Modes Range
TCAS I / II Mode C (with altitude reporting) -10,000 to +10,000 fpm
TCAS II Mode S formats 0, 11, 16 Resolution
100 fpm
Accuracy
10%

For the very latest specifications visit


SQUITTER MODE S
Range
Control
+43 to +58 dBm (20 to 631 watts)
On/Off
Resolution
Rate
0.1 dB
0.8 to 1.2 seconds, randomly distributed
Accuracy
RECEIVER
±1 dB
PULSE SPACING
FREQUENCY
ATCRBS (Mode C All Call)
Range
S1 to P1 2.0 µs
1029.900 to 1030.100 MHz
Accepts ≤±200 ns
Resolution
Rejects ≥±1.0 µs
1 kHz
P1 to P3 21.0 µs
Accuracy
Accepts ≤±200 ns
±10 kHz
Rejects (<10% Replies) ≥±1.0 µs
P1 to P4 23.0 µs TCAS BROADCAST INTERVAL
Accepts ≤±200 ns Range
Rejects (<10% Replies) ≥±1.0 µs 1.0 to 12.0 sec
Mode S Resolution
P1 to P2 2.0 µs 0.1 sec
Accepts ≤±200 ns Accuracy
Rejects (<10% Replies) ≥±1.0 µs ±0.2 sec
P1 to SPR 4.75 µs
MISCELLANEOUS INPUT/OUTPUTS
Accepts ≤±200 ns
Rejects (<10% Replies) ≥±1.5 µs RF I/O
Type
SUPPRESSION
Input/Output
ATCRBS (P2 or S1) Impedance
>0.5dB above level of P1 <10% Replies 50 Ω typical
UUT MEASUREMENTS Maximum Input Level
4 kW peak
ERP (@ 1030 MHZ) 10 W average
ATCRBS VSWR
Range <1.3:1
+43 to +58 dBm (20 to 631 watts) ANTENNA
Resolution Type
0.1 dB Input/Output
Accuracy Impedance
±2 dB 50 Ω typical
MODE S Maximum Input Level
Range 10 W peak
+43 to +58 dBm (20 to 631 watts) 0.5 W average
Resolution VIDEO
0.1 dB Type
Accuracy Output
±2 dB Impedance
DIRECT CONNECTION PEAK PULSE POWER (@ 1030 MHZ) 50 Ω typical
Generate Video Level
ATCRBS
1.1 Vpp (±0.4 V) into 50 Ω
Range
Receive Video Level
+43 to +58 dBm (20 to 631 watts)
Proportional to IF level
Resolution
Baseline
0.1 dB
±0.5 V referenced to ground
Accuracy
±1 dB
TEST ANTENNA
VSWR
<1.5:1
Gain PHYSICAL CHARACTERISTICS
6 dB, Typical DIMENSIONS
TIME BASE (TCXO) Height
Temperature Stability 11.2 inches (28.5 cm)
±1 ppm Width
Aging 9.1 inches (23.1 cm)
±1 ppm per year Depth
Accuracy 2.7 inches (6.9 cm)
±1 ppm Weight (Test set only)
Test Limit <8 lbs. (3.6 kg)
±0.3 ppm SUPPLEMENTAL INFORMATION
BATTERY Test Set Certifications
Type Altitude, operating MIL-PRF-28800F Class 2
Li Ion Altitude, not operating MIL-PRF-28800F Class 2
Duration Bench Handling MIL-PRF-28800F Class 2
>4 hrs continuous operation Blowing Dust MIL-STD-810F Method 510.4,
Procedure I
>6 hrs, Typical
Drip-proof MIL-PRF-28800F Class 2
INPUT POWER (TEST SET) Explosive Atmosphere MIL-STD-810F Method 511.4,
Input Range Procedure 1
11 to 32 Vdc Relative Humidity MIL-PRF-28800F Class 2
Power Consumption Shock, Functional MIL-PRF-28800F Class 2
55 W Maximum Vibration Limits MIL-PRF-28800F Class 2
16 W Nominal at 18 Vdc with charged battery Temp, operating NOTE 4 MIL-PRF-28800F Class 2
Fuse Requirements Temp, not operating NOTE 5 MIL-PRF-28800F Class 2
5 A, 32 Vdc, Type F Transit Drop MIL-PRF-28800F Class 2
Safety Compliance UL-61010B-1
INPUT POWER (SUPPLIED EXTERNAL AC TO DC EN 61010-1
CONVERTER) CSA 22.2 No 61010-1
Input Range EMC EN 61326
100 to 250 VAC, 1.5 A Max, 47 to 63 Hz External AC-DC Converter Certifications
Mains Supply Voltage Fluctuations Safety Compliance UL 1950 DS
≤10% of the nominal voltage CSA 22.2 No. 234
Transient Overvoltages VDE EN 60 950
According to Installation Category II EMI/RFI Compliance FCC Docket 20780 Curve “B”
EMC EN 61326
ENVIRONMENTAL (TEST SET)
Transit Case Certifications
Use Drop Test FED-STD-101C Method 5007.1
Pollution Degree 2 Paragraph 6.3,
Altitude Procedure A,
≤4800 meters Level A
Operating Temperature
NOTE 2
Falling Dart Impact ATA 300 Category I
-20°C to 55°C
Vibration, Loose Cargo FED-STD-101C Method 5019
Storage Temperature Vibration, Sweep ATA 300 Category I
NOTE 3
-30°C to 71°C Simulated Rainfall MIL-STD-810F Method 506.4
Relative Humidity Procedure II of 4.1.2
95% (±5%) from 5° to 30°C FED-STD-101C Method 5009.1
75% (±5%) from 30° to 40°C Sec 6.7.1
45% (±5%) from 40° to 55°C
Immersion MIL-STD-810F Method 512.4
ENVIRONMENTAL (SUPPLIED EXTERNAL AC TO DC
CONVERTER)
Use
Indoors
Altitude
≤10,000 meters
Operating Temperature
0° to 40°C
Storage Temperature
-20°C to 71°C

For the very latest specifications visit


VERSIONS AND ACCESSORIES
When ordering please quote the full ordering number information.
Ordering
Numbers Versions
6000-110 IFR 6000 Mode A/C/S Transponder and DME
Ramp Test Set, with US Mains Leads
6000-220 IFR 6000 Mode A/C/S Transponder and DME
Ramp Test Set, with European Mains Leads
6000OPT2 TCAS (TIS)
6000OPT3 ADS-B
Extended Standard Warranties with Calibration for 6000
W6000/203C Extended standard warranty 36 months with
scheduled calibration
W6000/205C Extended standard warranty 60 months with
scheduled calibration
Accessories for 6000
AC0820 Desk Top Stand
AC0826 Tripod
AC24006 Tripod, Dolly, Stand
AC0824CD IFR 6000 Maintenance Manual - CD
AC0825CD IFR 6000 Operation Manual - CD
AC0829 25ft TNC/TNC COAX
AC0830 50ft TNC/TNC COAX

Notes
NOTE 1 Simulates a 50.5 dBm XPDR ERP at 10 nMi range.
NOTE 2 Battery charging temperature range: 5°C to 40°C (controlled by internal
charger).
NOTE 3 Li Ion Battery must be removed below -20°C and above 60°C.
NOTE 4 Temperature range extended to -20°C to 55°C.
NOTE 5 Temperature range reduced to -30°C to 71°C.

You might also like