BOOSTER SETS WITH
Aquapack 1000 2 TO 4 LCR PUMPS
FUNCTION
When a tap is opened, water is taken from the diaphragm tank. Then
the pressure drops to the first cut-in pressure, and the first pump is
cut in. As the consumption rises, more pumps will be cut in until the
performance of the pumps in operation corresponds to the
requirement.
Pr1
Air handling Reduces risk of dry-running Pr2
Pr3
Spacer coupling Allows easy disassembly of motor from
One pump in Two pumps Three pumps
pump (for 11 kW motor onwards)
operation in operation in operation
Q
Sleeve sealing Provides high resistance to pressure
pulses and withstands temperature FIG. 1 OPERATION WITH CUT-IN AND CUT-OUT
fluctuations as well as external forces
LE 1000 CONTROLLER FOR 2 TO 4 PUMPS
Tungsten carbide Wear resistance, improved dry-running The Lubi LE 1000 Controller supervises a given number of mains-
bearings capability and handling of thermal shocks operated pumps.
enable longer operating time
The LE 1000 Controller offers the following features/functions:
Reinforced shaft Strong axial locking force and high torque
lock ring lock system enable robust and reliable Attractive control box with a dust proof & water proof IP 58
operation of rotating assembly protection & lockable key.
OPERATING CONDITIONS Cascade control, only the required number of pumps are in
Flow range :
Up to 232 m³/h operation at any time.
Operating pressure :
Max. 16 bar
Ambient temperature :
Max. + 40°C Highly reliable magnetic motor contactors.
Liquid temperature range :
0°C to +90°C
Maximum suction lift (H) :
The maximum suction lift (H) can be Single phase prevention & overload motor rotection.
calculated as follows:
H = 10.33 m - NPSH of the pump - other Dry run protection & low pressure protection.
suction losses - a safety margin of
Delay & minimum run timers to eliminate unnecessary pump
0.5 metres
Maximum inlet pressure : 6 bar cycle.
The Variable Frequency Drive also provides a smooth, ramp up Outer sleeve
of speed when the pump motor is started. These drastically
Tiebolts
reduces the starting current requirement for the pump motor. It
also reduces wear and tear on motor bearings & pump rotating Impellers
components. Base
SHAFT SEAL
The operating range of the shaft seal depends on operating
pressure, pump type, type of shaft seal and liquid temperature. The
following table apply to clean water and water with anti-freeze liquids.
SHAFT Max. temperature
DESCRIPTION range [°C]
SEAL
BBQE Bellow type shaft seal, Carbon/Sic/SS 316/EPDM -40°C to +120°C
BBQV Bellow type shaft seal, Carbon/Sic/SS 316/FKM -40°C to +120°C
FIG. 2 LE 1000V CONTROLLER DISPLAY FOR 2 TO 4 PUMPS HQQE Cartridge type shaft seal, Sic/Sic/SS 316/EPDM -40°C to +120°C
PROTECTION HBQE Cartridge type shaft seal, Carbon/Sic/SS 316/EPDM 0°C to +120°C
HBQV Cartridge type shaft seal, Carbon/Sic/SS 316/FKM 0°C to +90°C
A pressure switch or a level switch at the suction side can be used as HQQV Cartridge type shaft seal, Sic/Sic/SS 316/FKM -20°C to +90°C
dry-running protection. When the water level or pressure has been
restored, automatic or manual resetting is possible. CONSTRUCTION
TIME CONTROL Aquapack 1000 is built up on a common base frame. The pumps are
fixed to the base frame by means of bolts. The control cabinets are
To adapt the booster set operation to the actual conditions, the divided into three groups based on construction.
following settings can be made with the touch screen display:
Systems with the control cabinet mounted on the pump base frame.
Start-up delay : Prevents simultaneous start-up of all pumps. Systems with the control cabinet mounted on a separate base frame.
Systems with the control cabinet without a base frame, therefore
Stop delay : Prevents simultaneous stop of all pumps. suitable for floor mounting.
After-run delay : Keeps pumps in operation for few seconds, after A discharge manifold is mounted on the discharge side of the pumps.
cut-out pressure is reached. An isolating valve and non-return valve are mounted between the
discharge manifold and the individual pumps. The non-return valve may
Time control is particularly convenient to reduce the number of starts be mounted on the suction side on request.
and stops per hour, to prevent water hammer and negative pressure
in the suction manifold as well as other problems that can arise under A suction manifold is mounted on the suction side of the pumps. An
certain conditions. isolating valve is mounted between the suction manifold and the
individual pumps.
BOOSTER SETS WITH
Aquapack 1000 2 TO 4 LCR PUMPS
SYSTEM COMPONENTS
A
DELT
VERSIONS
8 1 POS. DESCRIPTION QTY.
“G” “L” “N”
1 Control panel 1 Metal, painted Metal, painted Metal, painted
2 Panel stand 2 Galvanized steel Galvanized steel 1.4301 (AISI 304)
3 Suction manifold 1 Galvanized steel 1.4301 (AISI 304) 1.4401 (AISI 316)
9 4 Isolating valve 2 per Brass NiCr- plated Brass NiCr- plated 1.4401 (AISI 316)
pump or cast iron or cast iron and cast iron
5 Base frame 1 Galvanized steel/Painted Galvanized steel/Painted 1.4301 (AISI 304)
6 Non-return valve 1 per Brass NiCr- plated Brass NiCr- plated 1.4401 (AISI 316)
7 2
pump or cast iron or cast iron
7 Discharge manifold 1 Galvanized steel 1.4301 (AISI 304) 1.4401 (AISI 316)
8 Pump 1-4 LCR LCRI LCRN
9 Diaphragm tank 1 As per customer requirement
3
6
5 4
FIG. 4 SYSTEM COMPONENTS
PERFORMANCE RANGE
400
10 100
9 90 300
8 80
p (kgf/cm²)
7 70 100
p (ps i)
H mts.
H ft.
90
6 60 200
80
5 50 70
LCR 2 LCR 4 LCR 10 LCR 20 LCR 45 LCR 90
60
4 40
LCR 3 LCR 5 LCR 15 LCR 32 LCR 64
50
3 30 100
40
90
80
70 30
2 20
3
2 3 4 6 8 10 20 30 40 60 80 100 200 300 400 500 Q (m /h)
1 2 4 6 8 10 20 40 60 80 100 Q (l/sec)
40 60 80 100 200 400 600 800 1000 2000 4000 6000 Q (l/min)