Professional Documents
Culture Documents
Two Way Slap Design
Two Way Slap Design
1 year ago
DESIGN OF TWO-WAY SLAB BY ACI-COEFFICIENTS
FF SLAB DESIGN
PANEL No :
Input Data:
Slab Dimensions
Short Span = 10 ft
Long Span = 20 ft
Span Ratio = 10 / 20 = 0.5
Slab Thickness (reqd) = 2 x (10+20) x 12 / 180 = 4. in
Slab Thickness (prvd) = 6. in in
Edge Conditions
Short Span Edge Condition = One Edge Continuous
Long Span Edge Condition = One Edge Continuous
Applied Loads
Slab self wt = 75.00 psf
Service Dead Load = 0.075 psf
Service Live Load = 220 psf
Material Strengths
Concrete Strength = 4 ksi
Steel Yield Strength = 60 ksi
Design Moments
Loads
Total Ultimate DL =1.4(75 + 0.075) = 105.105 psf
Total Ultimate LL =1.7(220) = 374 psf
Total Ultimate Load =105.105 + 374 = 479.105 psf
Reinforcement Calculations
Along Short Span
Positive Steel
Mu=4.36 k-ft ; b=12 in ; d=5.313 in ; fc'=4ksi ; fy= 60 ksi
Shear Check
Total load on the panel = 10 x 20 x 479.105 = 95.8 kips
Shear Capacity of the section fVc = 0.85 x 2 x ( 4000 )^� x 12 x 5.25 / 1000 = 6.77
k/ft
MATERIAL STRENGTH
Concrete Strength f'c 4 ksi Mu(-ve) = 2. k-ft
Steel Yeild Strength 60 ksi Asmin = 0.13
# 3 @ 10. in?