920 ~5010

360
525
~1200 ~200
Existing screws and fixing washers
on gearbox flange should be substituted
with new ones supplied
Ø457,2
Permanent threadlocking (Loctite 243)
~5080

4900

has to be applied where indicated


in order to avoid any fixation loosening

~4000
or flange movement during time
M Tightening torque
screws M10 Ts= 75 Nxm cl 12.9
fork torque wrench 17
N washers Nord-Lock

Angular speed of boom rotation ca. 0,59 rpm


which corresponds to a max peripheral
speed on boom tip of ~ 18 m/min
30

Ø19
900

170
900 RAL 5010 blue for column
RAL 1006 yellow for arm

Anchor type and size: HVU + HAS(-E) (5.8) M16


Installation torque: 0,080 kNm Static loads caused by the jib crane work on the
Hole diameter in the fixture: df = 19 mm
customer structures
Hole diameter in the base material: 18 mm
(To be checked by the building designer)
Hole depth in the base material: 125 mm
M = bending overturning moment at the rotating base
Minimum thickness of the base material: 170 mm
with jib arm (~270°)= 7565 kgxm
Drilling method: Hammer drilled
N = vertical compression load
Cleaning: Manual cleaning of the drilled hole according
to instructions for use is required. at the base = 2305 kg
All loads on the base given during quotation phase are calculated with the application of the
Drilled hole cleaning must be performed according to instructions Conventional Loads (coefficient according to UNI EN 13001) for the Lifting and Transport
for use (blow 4 times with the hand pump, brush 4 times, blow Equipment.
Consider loads as entirely unintentional. The given loads are therefore not amplified with
again 4
any coefficient (SLS or ULS).
times with the hand pump). It will be the responsibility of the structure designer to apply the coefficients related to the
type of load combination being studied.
diego

All dimensions in mm

CTE 100/5 24/10/2022 1 1 : 50

BORN TO LIFT Load Capacity 1000 kg CV 22G1488


OMIS FAC s.r.l. - Jib Cranes
Range from axis of rotation to cap 5000 mm CTE100-5_H490_TC_KQ10SD-3_ENGLISH.DWG
Via Galvani 37 - 36066 Sandrigo (VI) Italy