Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

7/12/2021 OceanStor 5500 V5, 5600 V5, and 5800 V5 - OceanStor V5 V500R007 Kunpeng Capacity Expansion Guide - Huawei

de - Huawei Data Storage

Data Storage Infocenter

OceanStor Infocenter
Search

Popular Keywords:
Specifications
File System Share
HyperMetro
Host Connectivity

Capacity Expansion Guide

Capacity Expansion Guide


>
Capacity Expansion by Adding Disk Enclosures
> Planning and Evaluation
>
Drafting the Connection Topology for High-Density Disk Enclosures
> OceanStor 5500 V5, 5600 V5, and
5800 V5

OceanStor 5500 V5, 5600 V5, and 5800 V5


You can either create a loop or use the existing loop to expand a disk enclosure. You are advised to
create a loop for the expansion.

NOTICE:

The number of disk enclosures in all expansion modes cannot exceed the specifications. Otherwise,

new disks cannot be added to the storage system.

High-density disk enclosures are deployed in dual-uplink networking.

All cascading cables are connected in forward mode. For details, see Connecting High-Density Disk

Enclosures to 2 U Controller Enclosures.

You can obtain more network diagrams from Huawei Storage Product Networking Assistant

(https://support.huawei.com/onlinetoolsweb/sna/#/home ).
OceanStor 5300 V5 (SAS) (Optional) Performing the Pre-expansion Evaluation

Ports and Slots for Cascading Disk Enclosures


https://support-it.huawei.com/docs/en-us/oceanstor-v500r007-kunpeng/capacity-expansion-guide/exp_046.html 1/5
7/12/2021 OceanStor 5500 V5, 5600 V5, and 5800 V5 - OceanStor V5 V500R007 Kunpeng Capacity Expansion Guide - Huawei Data Storage
Ports and Slots for Cascading Disk Enclosures

You can cascade high-density disk enclosures to onboard SAS ports or install SAS expansion modules in

slots IOM 3, IOM 4, and IOM 5 to connect to disk enclosures, as shown in the yellow area in the figure.

The priorities of the slots for installing expansion modules are as follows: IOM 5 > IOM 4 > IOM 3.

Expanding Capacity in a New Loop

The following example describes how to add a disk enclosure using the remaining idle expansion ports.

Figure 1 Adding a disk enclosure to a new loop

OceanStor 5300 V5 (SAS) (Optional) Performing the Pre-expansion Evaluation

https://support-it.huawei.com/docs/en-us/oceanstor-v500r007-kunpeng/capacity-expansion-guide/exp_046.html 2/5
7/12/2021 OceanStor 5500 V5, 5600 V5, and 5800 V5 - OceanStor V5 V500R007 Kunpeng Capacity Expansion Guide - Huawei Data Storage

Expanding Capacity in Existing Loops

If the controller enclosure has no available expansion ports, and the number of disk enclosures in each

loop does not surpass the specification limits, you can expand capacity by adding disk enclosures to the
OceanStor 5300 V5 (SAS) (Optional) Performing the Pre-expansion Evaluation
existing loops.
https://support-it.huawei.com/docs/en-us/oceanstor-v500r007-kunpeng/capacity-expansion-guide/exp_046.html 3/5
7/12/2021 OceanStor 5500 V5, 5600 V5, and 5800 V5 - OceanStor V5 V500R007 Kunpeng Capacity Expansion Guide - Huawei Data Storage

The following example describes how to add a disk enclosure to an existing loop.

Figure 2 Adding a disk enclosure to an existing loop

OceanStor 5300 V5 (SAS) (Optional) Performing the Pre-expansion Evaluation

https://support-it.huawei.com/docs/en-us/oceanstor-v500r007-kunpeng/capacity-expansion-guide/exp_046.html 4/5
7/12/2021 OceanStor 5500 V5, 5600 V5, and 5800 V5 - OceanStor V5 V500R007 Kunpeng Capacity Expansion Guide - Huawei Data Storage

Is this page helpful?


Yes
No

OceanStor 5300 V5 (SAS) (Optional) Performing the Pre-expansion Evaluation

https://support-it.huawei.com/docs/en-us/oceanstor-v500r007-kunpeng/capacity-expansion-guide/exp_046.html 5/5