REINFORCED CONCRETE

COVER SLAB.
450 X 600
450 X 600 manhole cover.
COVER.
GL COVER. GL.
INLET 150mm r.c cover slab.
M.H OUTLET GL.
INLET LEVEL OF

390
INCOMING DRAIN. M.H 140mm stone wall.

260
TO SOAK

390
HEIGHT VARIES

650
PIT. (3M - 6M)
CONC 1:3:6 MIX

260

F2
F1
1,040
MASONRY WITH 10MM
WATER PROOF RENDERING 200 MM STONE BLOCKS
ON BOTH SIDES. FOR LOOSE GROUND OR
WHERE SPECIFIED.

CONCRETE BASE.

FRONT ELEVATION SIDE ELEVATION


SECTION X- X THRU' THE SEPTIC TANK SECTION THRU' THE SOAK PIT

A B C
X7 X7

E
TANK CONSTRUCTION
BACK ELEVATION PLAN PARAMETERS.
North Elevation
S-01

11,800 SIDE ELEVATION SEPTIC TANK AND SOAK PIT


200 3,650 200 3,700 200 3,650 200 Roof Construction DETAILS
Roof pitch 25 degrees
100x50mm wall plate, tie beams and king posts
50x75 timber purlins.
200

50x50mm ratfers, ties and strutts.


200

50x75 timber ceiling joist @ 600 c/c.

RIVER
STUDY 50x50 timber brandering @ 600 c/c.
2,500

200

AREA 28 G box profile sheets to clients approval.

STREAM
1,600

KITCHEN
PANTRY
2.4x1.2 chip board ceiling.
200x25 timber fascia board. 33,500
3,350

BEDROOM
East Elevation

grill / louvres

2
200

200
West Elevation

I.C.
I.C.
KITCHEN DINING
2,750

2,750

200

AREA EXISTING HOUSE.

2,100
1,000

RIVER
W/C
200

200
9,700

9,700

STREAM
200

1,130 1,300

GATE
I.C.
I.C.

35,000

35,200
W
1,000

1,000

A
CL IN LK
O VERANDAH SH Existing toilet
SOAK
1,680

PIT

SE
W/C T
SITTING with septic tank
STUDY GATE
ROOM KITCHEN beneath.

2,900
ROOM
200

200

VERANDAH
120

MASTER
3,350

BEDROOM SITTING
BEDROOM
2,750

RIVER
TV STAND

ROOM 1
4,570

STREAM
200 3,650 200 3,700 200 3,650 200 CHINGA FARM
34,500
200

200

Substructural Construction.
200

100mm high skirting


25mm natural cement screed
SITE / BLOCK PLAN
1,200

Entry Porch 125mm (1:3:6) floor concrete slab


BRC -A142 laid throughout the floor slab. LOCATION MAP
1000G polythene damp proof membrane
50 approved compacted murram blind.
SECTION - 01 250mm well compacted hardcore.
Front Elevation 200x600 (1:2:4) rc strip concrete foundation footing
GROUND PLAN
S-01

NOTES 5. Walls below 200 mm thick to be reinforced with hoop TITLE PROPOSED RESIDENTIAL BUNGALOW DOOR AND WINDOW SCHEDULE DRWG NO.
DRAWN BY;

15
iron at every alternate course. ON PLOT BLOCK NO......... Item Description Type length widthquantity
1. All dimensions are in millimeters unless SUBUKIA/CHINGA FARM
otherwise stated. 6. DPC to be laid under all walls and to be min. 150mm DOORS MURAYA JOSEPH G.
D1 Steel metal casement Double leaf 2100 1200 1
above finished ground level. SUBUKIA SUB-COUNTY josephmuraya60@gmail.com
2. All dimensions should be checked on site D2 '' '' '' Single leaf 2100 1000 1
and any discrepancies to be reported to the 7.All new works to match existing works. D3 Solid panel door '' 2000 900 6 +254-708-762-355.
architect immediately. D4 Semi solid flash door '' 2000 850 3
+254-789-544-441.
8. All reinforced concrete works is to be in accordance with WINDOWS
3. All works to be carried out in accordance structural engineer details. CLIENT ALEX MWANGI KIRAGU W1 Steel metal casement Two way 1400 1200 2
with the local authority regulations. P.O. BOX 65 W2 '' '' '' Two way 1200 1200 4
9. 1000 gauge polythene (damp prove membrane) and anti DATE
4. DO NOT SCALE from the drawing, SUBUKIA. W3 '' '' (Store window) One way 500 800 1
termite treatment to be provided under ground floor
Use figured dimensions only. concrete slab.
W4 '' '' (w/c windows) One way 500 600 3 August, 2022
SIGN .................................... DATE ..................................... W5 '' '' (study window) Two way 1000 600 2

GSPublisherVersion 0.5.100.100