Download as pdf or txt
Download as pdf or txt
You are on page 1of 31

SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...

\FB142 - <offline> 10/28/2004 12:54:52

FB142 - <offline>
"M code Misc"
Name: Family:
Author: Mectron Version: 0.1
Block version: 2
Time stamp Code: 04/04/30 17:05:05Χ΋
Interface: 03/05/27 19:21:37Χ΋
Lengths (block/logic/data): 01702 01404 00004

Address Declaration Name Type Initial value Comment


in
out
in_out
0.0 stat ExU_1_ST BOOL FALSE External Unit 1 Start Command
0.1 stat ExU_2_ST BOOL FALSE External Unit 2 Start Command
0.2 stat Tool_I BOOL FALSE Tool Monitor Input Signal
0.3 stat ToolMon BOOL FALSE Tool Monitor
0.4 stat Tool_A BOOL FALSE Tool Broken Alarm
0.5 stat ToolSen_A BOOL FALSE Tool Sensor Broken Error
0.6 stat ExCnt BOOL FALSE External Counter
0.7 stat ExCntOff BOOL FALSE External Counter Count Off Timer
1.0 stat ExCntUp BOOL FALSE External Counter Count Up
1.1 stat M25Hold BOOL FALSE
1.2 stat OV_Cancel BOOL FALSE Override Cancel
1.3 stat AirBlow1 BOOL FALSE
1.4 stat AirBlow2 BOOL FALSE
1.5 stat AirBlow1S BOOL FALSE
1.6 stat AirBlow2S BOOL FALSE
1.7 stat clamp1sw_ILK BOOL FALSE Clamp 1 switch interlock
2.0 stat clamp1sw BOOL FALSE Clamp 1 switch
2.1 stat clamp1_IR BOOL FALSE Clamp 1 switch assist
2.2 stat clamp1_unclamp BOOL FALSE Clamp 1 unclamp signal
2.3 stat clamp1_clamp BOOL FALSE Clamp 1 clamp signal
2.4 stat clamp2sw_ILK BOOL FALSE Clamp 2 switch interlock
2.5 stat clamp2sw BOOL FALSE Clamp 2 switch
2.6 stat clamp2_IR BOOL FALSE Clamp 2 switch assist
2.7 stat clamp2_unclamp BOOL FALSE Clamp 2 unclamp signal
3.0 stat clamp2_clamp BOOL FALSE Clamp 2 clamp signal
3.1 stat AirLT_1 BOOL FALSE M80 Keep
3.2 stat AirLT_1_E BOOL FALSE Air Limitte 1 Error
3.3 stat AirLT_2 BOOL FALSE M82 Keep
3.4 stat AirLT_2_E BOOL FALSE Air Limitte 2 Error
3.5 stat Count_up BOOL FALSE Count_up
0.0 temp clamp1_unclamped BOOL Unclamp 1 sensor
0.1 temp clamp1_clamped BOOL clamp 1 sensor
0.2 temp clamp1_unclampedFIN BOOL clamp 1 unclamp FIN
0.3 temp clamp1_clampedFIN BOOL clamp 1 clamp FIN

Page 1..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Address Declaration Name Type Initial value Comment


0.4 temp clamp1_err BOOL
0.5 temp clamp2_unclamped BOOL
0.6 temp clamp2_clamped BOOL
0.7 temp clamp2_unclampedFIN BOOL
1.0 temp clamp2_clampedFIN BOOL
1.1 temp clamp2_err BOOL
1.2 temp AirLT_1_I BOOL Air Limiter 1 Input signal
1.3 temp AirLT_2_I BOOL Air Limiter 2 Input signal

Block: FB142 M code Misc.

Rev. 2002-4-23 : YSNC


1: M70/M71 : External Unit Drive
2: M200/M201/M206: Tool Monitor
Dummy signal should be fixed!!!
3: M25 : External Counter
Dummy signal is used as a macro program information signal.
4: M48/M49 : Override Cancel
5: M32~M35 : Air Blow 1/2

Page 2..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 1 Clamp 1 switch interlock


DB120.DBX247.4: 1= 1 switch controls clamp/unclamp.
DB121.DBX2.1 : STL
DB36.DBX64.6 : Spindle reversing
DB36.DBX64.7 : Spindle forwarding
/Unclamp1-SW & /Clamp1-SW & /STL & /SP-REV & /SP-FWD & /RSTS ===> clamp1sw_ilk

DB121.DBX2 DB36.DBX64 DB36.DBX64 #clamp1sw_


I4.3 I4.2 .1 .6 .7 M10.0 ILK

DB120.DBX2
47.4

#clamp1sw_
ILK

Symbol information
I4.3 UNCLP1SW Unclmp1 Switch
I4.2 CLMP1SW Clamp1 Switch
DB36.DBX64.6 "SP".E_TCMinus Traverse command minus
DB36.DBX64.7 "SP".E_TCPlus Traverse command plus
M10.0 RSTS In reset state

Network: 2 Clamp 1 switch


DB120.DBX247.4: 1= 1 switch controls clamp/unclamp.

Clamp1-SW & clamp1sw_ILK & PLC-MD ===(P)===> clamp1sw

#clamp1sw_ DB120.DBX2
I4.2 ILK 47.4 #clamp1_IR #clamp1sw
P

Page 3..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Symbol information
I4.2 CLMP1SW Clamp1 Switch

Network: 3

DB120.DBX2 #clamp1sw_ DB76.DBX1. #clamp1_cl


I4.2 47.4 ILK 3 M3.0 amp

#clamp1_un
clamp #clamp1sw

#clamp1_cl #clamp1_un
amp clamp

DB76.DBX1.
2

Symbol information
I4.2 CLMP1SW Clamp1 Switch
DB76.DBX1.2 "MDECODE".M10 M10 DECODE
DB76.DBX1.3 "MDECODE".M11 M11 DECODE
M3.0 MReady Machine Ready (w/o timer)

Page 4..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 4
M11 and so on & /M10 & MRDY ===> clmap1_unclamp

DB120.DBX2 #clamp1sw_ DB76.DBX1. #clamp1_un


I4.3 47.4 ILK 2 M3.0 clamp

#clamp1_un
clamp #clamp1sw

#clamp1_cl #clamp1_un
amp clamp

DB76.DBX1.
3

Symbol information
I4.3 UNCLP1SW Unclmp1 Switch
DB76.DBX1.3 "MDECODE".M11 M11 DECODE
DB76.DBX1.2 "MDECODE".M10 M10 DECODE
M3.0 MReady Machine Ready (w/o timer)

Network: 5

#clamp1_cl #clamp1_un
amp clamp Q7.1

Symbol information
Q7.1 CLMP1 Clamp1 SOL

Page 5..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 6

#clamp1_cl #clamp1_un
amp clamp Q7.0

Symbol information
Q7.0 UNCP1 Unclamp1 SOL

Network: 7 Clamp 1 status: unclamp


DB120.DBX247.1: 1=Clamp1 with a LS to monitor unclamp status

#clamp1_un
I11.0 clamped

DB120.DBX2
47.1

Symbol information
I11.0 SQ25 Unclamp1 SQ

Page 6..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 8 Clamp 1 status: clamp


DB120.DBX247.0: 1=Clamp1 with a LS to monitor clamp status

#clamp1_cl
I11.1 amped

DB120.DBX2
47.0

Symbol information
I11.1 SQ26 Clamp1 SQ

Network: 9 Clamp 1 clamping complettion

#clamp1_un T25 #clamp1_un


clamped Q7.0 S_ODT clampedFIN
S Q

DB120.DBW5
0 TV BI
R BCD

Symbol information
Q7.0 UNCP1 Unclamp1 SOL

Page 7..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 10

#clamp1_un
clampedFIN Q2.2

Network: 11 Clamp 1 unclamping complettion

#clamp1_cl T26 #clamp1_cl


amped Q7.1 S_ODT ampedFIN
S Q

DB120.DBW5
2 TV BI

R BCD

Symbol information
Q7.1 CLMP1 Clamp1 SOL

Page 8..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 12
DB120.DBX247.0: 1=Clamp1 with a LS to monitor clamp status
DB120.DBX247.1: 1=Clamp1 with a LS to monitor unclamp status

DB120.DBX2 #clamp1_cl #clamp1_er


47.0 amped Q7.0 r

DB120.DBX2 #clamp1_un
47.1 clamped Q7.1

Symbol information
Q7.0 UNCP1 Unclamp1 SOL
Q7.1 CLMP1 Clamp1 SOL

Network: 13 Clamp 1 Sensor Time-out Error

#clamp1_cl T27 DB2.DBX182


Q7.1 amped M10.1 S_ODT .0
S Q
#clamp1_un DB120.DBW5
Q7.0 clamped 4 TV BI
R BCD
#clamp1_er
r

DB2.DBX182
.0

Page 9..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Symbol information
Q7.1 CLMP1 Clamp1 SOL
Q7.0 UNCP1 Unclamp1 SOL
DB2.DBX182.0 "ALMSG_DB".A7000xx[16] Alarm 700000-700063 (user area 0)
M10.1 Alm_RST Alarm Resetting State

Network: 14 M10 FIN

DB76.DBX1. #clamp1_cl DB2.DBX182 DB76.DBX1.


2 ampedFIN .0 2
R

Symbol information
DB76.DBX1.2 "MDECODE".M10 M10 DECODE
DB2.DBX182.0 "ALMSG_DB".A7000xx[16] Alarm 700000-700063 (user area 0)

Network: 15 M11 FIN

DB76.DBX1. #clamp1_un DB2.DBX182 DB76.DBX1.


3 clampedFIN .0 3
R

Symbol information
DB76.DBX1.3 "MDECODE".M11 M11 DECODE
DB2.DBX182.0 "ALMSG_DB".A7000xx[16] Alarm 700000-700063 (user area 0)

Page 10..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 16 Clamp/Unclamp 2 doorsill

Network: 17 Clamp 2 switch interlock


DB120.DBX247.5: 1= 1 switch controls clamp/unclamp.
DB121.DBX2.1 : STL
DB36.DBX64.6 : Spindle reversing
DB36.DBX64.7 : Spindle forwarding

DB121.DBX2 DB36.DBX64 DB36.DBX64 #clamp2sw_


I4.5 I4.4 .1 .6 .7 M10.0 ILK

DB120.DBX2
47.5

#clamp2sw_
ILK

Symbol information
I4.5 UNCLP2SW Uuclamp2 Switch
I4.4 CLMP2SW Clamp2 Switch
DB36.DBX64.6 "SP".E_TCMinus Traverse command minus
DB36.DBX64.7 "SP".E_TCPlus Traverse command plus
M10.0 RSTS In reset state

Page 11..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 18 Clamp 2 switch


DB120.DBX247.4: 1= 1 switch controls clamp/unclamp.

#clamp2sw_ DB120.DBX2
I4.4 ILK 47.5 #clamp2_IR #clamp2sw
P

Symbol information
I4.4 CLMP2SW Clamp2 Switch

Network: 19

DB120.DBX2 #clamp2sw_ DB76.DBX9. #clamp2_cl


I4.4 47.5 ILK 7 M3.0 amp

#clamp2_un
clamp #clamp2sw

#clamp2_cl #clamp2_un
amp clamp

DB76.DBX9.
6

Symbol information
I4.4 CLMP2SW Clamp2 Switch
DB76.DBX9.6 "MDECODE".M78 M78 DECODE
DB76.DBX9.7 "MDECODE".M79 M79 DECODE
M3.0 MReady Machine Ready (w/o timer)

Page 12..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 20

DB120.DBX2 #clamp2sw_ DB76.DBX9. #clamp2_un


I4.5 47.5 ILK 6 M3.0 clamp

#clamp2_un
clamp #clamp2sw

#clamp2_cl #clamp2_un
amp clamp

DB76.DBX9.
7

Symbol information
I4.5 UNCLP2SW Uuclamp2 Switch
DB76.DBX9.7 "MDECODE".M79 M79 DECODE
DB76.DBX9.6 "MDECODE".M78 M78 DECODE
M3.0 MReady Machine Ready (w/o timer)

Network: 21

#clamp2_cl #clamp2_un
amp clamp Q7.3

Symbol information
Q7.3 CLMP2 Clamp2 SOL

Page 13..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 22

#clamp2_un #clamp2_cl
clamp amp Q7.2

Symbol information
Q7.2 UNCP2 Unclamp2 SOL

Network: 23 Clamp 2 status: unclamp


DB120.DBX247.1: 1=Clamp1 with a LS to monitor unclamp status

#clamp2_un
I11.2 clamped

DB120.DBX2
47.3

Symbol information
I11.2 SQ27 Unclamp2 SQ

Page 14..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 24 Clamp 2 status: clamp


DB120.DBX247.0: 1=Clamp1 with a LS to monitor clamp status

#clamp2_cl
I11.3 amped

DB120.DBX2
47.2

Symbol information
I11.3 SQ28 Clamp2 SQ

Network: 25 Clamp 2 clamping complettion

#clamp2_un T28 #clamp2_un


clamped Q7.2 S_ODT clampedFIN
S Q

DB120.DBW5
6 TV BI
R BCD

Symbol information
Q7.2 UNCP2 Unclamp2 SOL

Page 15..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 26

#clamp2_un
clampedFIN Q2.3

Network: 27 Clamp 2 unclamping complettion

#clamp2_cl T29 #clamp2_cl


amped Q7.3 S_ODT ampedFIN
S Q

DB120.DBW5
8 TV BI

R BCD

Symbol information
Q7.3 CLMP2 Clamp2 SOL

Page 16..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 28
DB120.DBX247.0: 1=Clamp1 with a LS to monitor clamp status
DB120.DBX247.1: 1=Clamp1 with a LS to monitor unclamp status

DB120.DBX2 #clamp2_cl #clamp2_er


47.2 amped Q7.2 r

DB120.DBX2 #clamp2_un
47.3 clamped Q7.3

Symbol information
Q7.2 UNCP2 Unclamp2 SOL
Q7.3 CLMP2 Clamp2 SOL

Network: 29 Clamp 2 Sensor Time-out Error

#clamp2_cl T30 DB2.DBX182


Q7.3 amped M10.1 S_ODT .1
S Q
#clamp2_un DB120.DBW6
Q7.2 clamped 0 TV BI
R BCD
#clamp2_er
r

DB2.DBX182
.1

Page 17..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Symbol information
Q7.3 CLMP2 Clamp2 SOL
Q7.2 UNCP2 Unclamp2 SOL
DB2.DBX182.1 "ALMSG_DB".A7000xx[17] Alarm 700000-700063 (user area 0)
M10.1 Alm_RST Alarm Resetting State

Network: 30 M68 FIN

DB76.DBX9. #clamp2_cl DB2.DBX182 DB76.DBX9.


6 ampedFIN .1 6
R

Symbol information
DB76.DBX9.6 "MDECODE".M78 M78 DECODE
DB2.DBX182.1 "ALMSG_DB".A7000xx[17] Alarm 700000-700063 (user area 0)

Network: 31 M69 FIN

DB76.DBX9. #clamp2_un DB2.DBX182 DB76.DBX9.


7 clampedFIN .1 7
R

Symbol information
DB76.DBX9.7 "MDECODE".M79 M79 DECODE
DB2.DBX182.1 "ALMSG_DB".A7000xx[17] Alarm 700000-700063 (user area 0)

Page 18..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 32 Doorsill

Network: 33 M70 External Unit 1 Start Signal


DB125.DBX0.5/6: The 2nd Ref. Point of X & Y. (J100 P.38 R.9)

DB125.DBX0 DB125.DBX0 DB76.DBX8.


.5 .6 6 #ExU_1_ST

DB120.DBX2 Q6.5
44.2

Symbol information
DB125.DBX0.5 "ZRN".ZRN2_X X axis is on the 2nd reference point.
DB125.DBX0.6 "ZRN".ZRN2_Y Y axis is on the 2nd reference point.
DB76.DBX8.6 "MDECODE".M70 M70 DECODE
Q6.5 E.ST1 External Unit Start CMD 1

Page 19..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 34 M71 External Unit 2 Start Signal


DB125.DBX0.5/6: The 2nd Ref. Point of X & Y. (J100 P.38 R.9)

DB125.DBX0 DB125.DBX0 DB76.DBX8.


.5 .6 7 #ExU_2_ST

DB120.DBX2 Q6.6
44.2

Symbol information
DB125.DBX0.5 "ZRN".ZRN2_X X axis is on the 2nd reference point.
DB125.DBX0.6 "ZRN".ZRN2_Y Y axis is on the 2nd reference point.
DB76.DBX8.7 "MDECODE".M71 M71 DECODE
Q6.6 E.ST2 External Unit Start CMD 2

Network: 35 M70 FIN signal

DB76.DBX8. DB76.DBX8.
6 #ExU_1_ST I10.4 6
R

Symbol information
DB76.DBX8.6 "MDECODE".M70 M70 DECODE
I10.4 MFIN2 M Function FIN Sig.2

Page 20..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 36 M71 FIN signal

DB76.DBX8. DB76.DBX8.
7 #ExU_2_ST I10.5 7
R

Symbol information
DB76.DBX8.7 "MDECODE".M71 M71 DECODE
I10.5 MFIN3 M Function FIN Sig.3

Network: 37 Doorsill (no meaning)

Network: 38 Tool Monitor Input

Dummy should be fixed!!! Macro Program Input UI0. T.K


P.10 R.7

I10.6 #Tool_I

Symbol information
I10.6 TLMONT Tool Monitor Sig.IN

Page 21..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 39 Tool Monitor (M200)

DB76.DBX14
.0 M10.0 #ToolMon

DB76.DBX14
#ToolMon .1

Symbol information
DB76.DBX14.0 "MDECODE".M200 M200 DECODE
DB76.DBX14.1 "MDECODE".M201 M201 DECODE
M10.0 RSTS In reset state

Network: 40 Tool Broken Alarm (M200)

#ToolMon #Tool_I M10.1 #Tool_A

#Tool_A DB2.DBX182
.7

Symbol information
M10.1 Alm_RST Alarm Resetting State
DB2.DBX182.7 "ALMSG_DB".A7000xx[23] Alarm 700000-700063 (user area 0)

Page 22..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 41 Tool Sensor Broken Alarm (M206)

DB76.DBX14
.6 #Tool_I M10.1 #ToolSen_A

#ToolSen_A DB2.DBX180
.6

Symbol information
DB76.DBX14.6 "MDECODE".M206 M206 DECODE
M10.1 Alm_RST Alarm Resetting State
DB2.DBX180.6 "ALMSG_DB".A7000xx[6] Alarm 700000-700063 (user area 0)

Network: 42 M206 FIN

DB76.DBX14 DB76.DBX14
.6 #Tool_I .6
R

Symbol information
DB76.DBX14.6 "MDECODE".M206 M206 DECODE

Network: 43 Doorsill (no meaning)

Page 23..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 44

DB76.DBX3.
1 #M25Hold
S

Symbol information
DB76.DBX3.1 "MDECODE".M25 M25 DECODE

Network: 45

#ExCntOff #M25Hold
R

Network: 46 External Counter

#M25Hold #ExCntOff M10.1 #ExCnt

#ExCnt T39
S_ODT #ExCntOff
S Q

DB120.DBW1
26 TV BI
R BCD

Page 24..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Symbol information
M10.1 Alm_RST Alarm Resetting State

Network: 47 External Counter Count Up


DB120.DBX244.3: Count-up Timing 0=immediately, 1=Cycle-End
M1.3 is used instead of "Target Part Number Reached" signal (#3514.7).
This signal isn't supportted in YS840/830DI.
Therefore, YS840/830DI HMI should be customized for that.

DB130.DBX2 DB120.DBX2
.0 44.3 I10.7 #ExCntUp

#ExCntUp

DB120.DBX2
44.3

Symbol information
DB130.DBX2.0 "Basic2".M2_M30_FIN M2 or M30 decode with delay
I10.7 ECTUPS Ex.Counter Count UP sig.IN

Network: 48
Dummy signal should be changed to a suitable address to notice "Count-up" to a
macro program.

#ExCntUp #Count_up

Page 25..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 49 Doorsill (no meaning)

Network: 50 Override Cancel M49

DB76.DBX6. DB76.DBX3.
1 M10.0 6 #OV_Cancel

DB76.DBX6.
#OV_Cancel 0

Symbol information
DB76.DBX6.1 "MDECODE".M49 M49 DECODE
DB76.DBX6.0 "MDECODE".M48 M48 DECODE
M10.0 RSTS In reset state
DB76.DBX3.6 "MDECODE".M30 M30 DECODE

Page 26..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 51 Override Cancel Condition


M49 or TAP or PMON1_area at Auto/MDI mode

DB82.DBX37
#OV_Cancel .2 M2.5

DB36.DBX84
.3

DB123.DBX2
.5 M1.1

Symbol information
DB82.DBX37.2 "CMM_PLC".CMM_OUT.dry_run_activ dry run activ
DB36.DBX84.3 "SP".E_Tapping Tapping without compensating chuck
DB123.DBX2.5 "OP_MODE".AutoMDI Selecting Auto or MDI mode
M1.1 AlwaysON Always on signal
M2.5 OVC Override cancel request signal

Network: 52 Doorsill (no meaning)

Page 27..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 53 Air Blow 1 internal relay set


M32 & Not-Rst-state => AirBlow1 until M33 comes.

DB76.DBX4.
0 M10.0 #AirBlow1

DB76.DBX4.
#AirBlow1 1

Symbol information
DB76.DBX4.0 "MDECODE".M32 M32 DECODE
DB76.DBX4.1 "MDECODE".M33 M33 DECODE
M10.0 RSTS In reset state

Network: 54 Air Blow 2 internal relay set


M34 & Not-Rst-state => AirBlow2 until M35 comes.

DB76.DBX4.
2 M10.0 #AirBlow2

DB76.DBX4.
#AirBlow2 3

Symbol information
DB76.DBX4.2 "MDECODE".M34 M34 DECODE
DB76.DBX4.3 "MDECODE".M35 M35 DECODE
M10.0 RSTS In reset state

Page 28..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 55 Air Blow 1 set


M00/M01 condition & Door Interlock condition & AirBlow1 ===> AirBlow1S set

DB21.DBX32 DB144.DBX2
.5 .1 #AirBlow1 #AirBlow1S

DB120.DBX2 DB120.DBX2 Q8.3


43.2 43.4

Symbol information
DB21.DBX32.5 "CHAN".E_M01 M0/M1 active
DB144.DBX2.1 "Dr_INLK".Dr_ILK_1 Door Interlock 1
Q8.3 AIRBL1 Air Blow 1

Network: 56 Air Blow 2 set

DB21.DBX32 DB144.DBX2
.5 .1 #AirBlow2 #AirBlow2S

DB120.DBX2 DB120.DBX2
43.3 43.5

Symbol information
DB21.DBX32.5 "CHAN".E_M01 M0/M1 active
DB144.DBX2.1 "Dr_INLK".Dr_ILK_1 Door Interlock 1

Page 29..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Network: 57 Air Limitter 1 Input


Dummy should be fixed!!!
P.11 R.16

I11.4 #AirLT_1_I

Symbol information
I11.4 ALT1 Air Limitter 1

Network: 58 Air Limitter 2 Input


Dummy!!! T.K
P.11 R.18

I11.5 #AirLT_2_I

Symbol information
I11.5 ALT2 Air Limitter 2

Network: 59 Air Limitter 1 Confirmation

DB76.DBX10
.0 M10.0 #AirLT_1

DB76.DBX10
#AirLT_1 .1

Page 30..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FB142 - <offline> 10/28/2004 12:54:52

Symbol information
DB76.DBX10.0 "MDECODE".M80 M80 DECODE
DB76.DBX10.1 "MDECODE".M81 M81 DECODE
M10.0 RSTS In reset state

Network: 60 Air Limitter 1 Error

#AirLT_1 #AirLT_1_I M10.1 #AirLT_1_E

#AirLT_1_E DB2.DBX181
.0

Symbol information
M10.1 Alm_RST Alarm Resetting State
DB2.DBX181.0 "ALMSG_DB".A7000xx[8] Alarm 700000-700063 (user area 0)

Page 31