Professional Documents
Culture Documents
FC106
FC106
FC106 - <offline>
"MCP functions 2"
Name: Family:
Author: Mectron Version: 0.1
Block version: 2
Time stamp Code: 04/04/30 17:08:00Χ΋
Interface: 02/04/28 19:48:50Χ΋
Lengths (block/logic/data): 00326 00212 00002
1: Patrol Lights
2: Auto Power OFF
3: Lamp for ATC area
DB2.DBX189
.0 M0.3 Q0.3
DB2.DBX189
.1
M10.3
Symbol information
DB2.DBX189.0 "ALMSG_DB".A7001xx[8] Alarm 700100-700163 (user area 1)
DB2.DBX189.1 "ALMSG_DB".A7001xx[9] Alarm 700100-700163 (user area 1)
Page 1..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FC106 - <offline> 10/28/2004 13:02:41
DB121.DBX2 DB21.DBX35
.5 .0 Q8.2
Symbol information
DB21.DBX35.0 "CHAN".E_ProgRunn Program running
Q8.2 GREL Warning Light Green
DB76.DBX0.
2 M3.0 M1.5
DB76.DBX3.
6
Symbol information
DB76.DBX0.2 "MDECODE".M2 M02 DECODE
DB76.DBX3.6 "MDECODE".M30 M30 DECODE
M1.5 YELLOW Signal Tower Yellow sub
I2.2 STB Cycle Start
I11.6 EX.STB EX.Cycle Start sig.
Page 2..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FC106 - <offline> 10/28/2004 13:02:41
DB21.DBX32 DB120.DBX2
.5 48.0 M3.0 Q8.1
M1.5
Symbol information
DB21.DBX32.5 "CHAN".E_M01 M0/M1 active
M1.5 YELLOW Signal Tower Yellow sub
M3.0 MReady Machine Ready (w/o timer)
Q8.1 YELL Warning Light Yellow
DB120.DBX2
Q8.1 48.1 Q8.0
M10.3
Symbol information
Q8.1 YELL Warning Light Yellow
M10.3 Alarm1 Alarm 1
Q8.0 REDL Warning Light Red
Page 3..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FC106 - <offline> 10/28/2004 13:02:41
DB130.DBX2
.0 M10.7 M10.6
M10.3
M10.6
Symbol information
DB130.DBX2.0 "Basic2".M2_M30_FIN M2 or M30 decode with delay
M10.3 Alarm1 Alarm 1
M10.6 APOF_En Auto Power Off Function Enable
M10.7 APOF_Set Auto Power Off Function Set
DB121.DBX2 DB123.DBX1
.1 .6 I3.7 M10.7
M10.7
Symbol information
DB123.DBX1.6 "OP_MODE".Auto Selecting Auto Mode
M10.7 APOF_Set Auto Power Off Function Set
I3.7 APOF AUTO Power off select
Page 4..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FC106 - <offline> 10/28/2004 13:02:41
T45
M10.6 S_ODT M10.5
S Q
M10.5 M10.7 DB120.DBW2
2 TV BI
R BCD
Symbol information
M10.6 APOF_En Auto Power Off Function Enable
M10.5 EStopOn ESTOP Forced Sign
M10.7 APOF_Set Auto Power Off Function Set
T46
M10.5 S_ODT Q6.7
S Q
DB120.DBW2
4 TV BI
R BCD
Symbol information
M10.5 EStopOn ESTOP Forced Sign
Q6.7 APOFF AUTO Power OFF/Tripping Output
Page 5..
SIMATIC N3883001\SIMATIC 300(1)\PLC315-2DP M/S 2AF03\...\FC106 - <offline> 10/28/2004 13:02:41
M4.1 Q0.2
DB205.DBX4 DB123.DBX1
.2 M0.3 .1
Symbol information
M4.1 PMON1 ATC area
M0.3 Flicker_0.5s Flicker Time 0.5 msec
DB123.DBX1.1 "OP_MODE".SW_TC_MAN Dial SW ATC Manual position
Q0.2 AREAL ATC Area Lamp
Page 6