Beam

detection
others look
up to

THE WORLDS MOST TRUSTED BEAM

FFE Ltd. A global innovator in the design and


manufacture of world class fire detection solutions. FFEUK.COM
FFE is a global innovator in the design and
manufacture of world class fire detection solutions.

FIRERAY®­¯ Trusted by installers, distributors and organisations


for over 40 years, our Talentum®, Fireray®, Aviation
Fire Extinguishers and Vibration Switches help

WE STRIVE FOR¯ to protect high value buildings and assets. Our


commitment to fire detection and prevention led to

FIRERAY®­¯
the development of the world’s most trusted smoke

EXCELLENCE IN¯
detection beam, Fireray® the favoured choice
of many of the world’s leading smoke detection
distributors and installers. Our Talentum® range
was developed to provide early detection for

EVERYTHING¯ industries where fast flame detection is critical.

BEAM DETECTION¯ WE DO¯


Our solutions are designed and manufactured in
the UK and our customers are fully supported by
our team of fire protection experts. We provide
consultancy, training and full technical support, so
that you always have peace of mind in knowing that

OTHERS LOOK¯
your assets are given the best possible protection
from fire.

UP TO¯

CONTENT
03 About FFE 05 F
 ireray® range 06 Our products 12 Technical Specifications
04 Why use Fireray®? of flame detectors 10 Accessories 14 Worldwide protection
WORLD’S MOST TRUSTED BEAM

Beam Smoke Detectors are the wide area selling and the insight to help you choose
HOW DOES¯
WHY USE A¯ smoke detection technology of choice.
With a coverage of up to 1800m². Beam
the best Fireray® product to suit your needs.
Customers across numerous industries rely
A BEAM SMOKE¯
smoke detectors offer simplified wiring, on Fireray® for their accuracy and ease of use

BEAM SMOKE¯ installation and maintenance than other


detection types and are therefore the
best fire detection technology for wide
and end users trust the Fireray® name when
choosing a beam smoke detector. Choose
Fireray® to take advantage of an accurate
DETECTOR¯
WORK?­¯
DETECTOR?¯
area coverage. and reliable product, backed by 40 years
of experience.
Why choose Fireray®? A beam smoke detector works by sending an
Lifetime, cost, accuracy and reliability are Installations invisible infra-red (IR) beam of light across the
considerations that are crucial to making Fireray® protects many different buildings area being protected that the receiver then
the right product choice. Our commitment and establishments around the world measures. If smoke is present in the air, this
to these factors drives customer decisions which include: obscures, or blocks, the light received by the
to choose Fireray®. All of our products are – Derby Velodrome receiver. When enough smoke is in the air, FIRERAY®¯ Fireray® One Fireray® 5000 Fireray® 3000 Fireray® 3000 Exd
manufactured in the UK. As a result, we – Windsor Castle the IR light level will drop below a set level,
have full control of the products we are – Doha Airport which then triggers an alarm condition.
BEAM SMOKE¯
DETECTORS¯
BENEFITS¯ See page 12 for complete
range of technical specification

The Low level controller allows remote


access for maintenance and testing when
beams are situated high-up
Compensates for building movement
or lens contamination by readjusting the
AUTO - ALIGNMENT INTERGRATED LIGHT CANCELLATION beam to achieve the correct received
PROTECTS LARGE SPACES
Protects Large Spaces
LCT Integrated Integrated
Visible Laser Visible Laser Protects Large Spaces signal
Protects Large
Spaces during itsVisible
Integrated installed lifetime
Laser Protects Large Spaces
LCT Auto-Alignment VISIBLE LASER LCT Auto-Alignment Integrated Visible Laser TECHNOLOGY™ LCT
FirerayFireray Fireray Fireray Fireray
Fireray Fireray Firerayalarms from sunlight Fireray
Fireray Fireray Fireray Fireray FirerayPrevents nuisance
Ensures precise alignment Ease of installation Excels at detecting smoke by actively cancelling the ambient light
te; Prevents nuisance alarms from Seeinfrared
where the infrared beam isAligns Operating range Minimises
of 5m to 120m false alarms in
Prevents nuisance alarms
Aligns from
itself in less than athe
minute; Prevents isnuisance alarms itself in range
from less than awhere
minute; Prevents
is nuisance alarms from and only
toindicating a fault condition
beam is when
sunlightofby
the detector
actively andSee
cancelling
where the when
pointing
beam
aligning
giving beams of
confidence
Operating
over largeSee
of 5m
areas
to 120m
in the infrared beam applications
See
where Operating range ofthe5m
where 120mthe infrared
cancellation capacity is exceeded
Operating range of 5m to 120m
sunlight by activelyfaster
cancelling
installation and better sunlight
pointing giving confidence faster installation and
of by actively cancelling better sunlight
pointing giving confidence of by actively cancelling pointing giving confidence of
ambient
reflector lightoptical path
in the from a distance
alignment wide indoor spaces reflective surfaces
ambientorlight
direct
ambient light performance alignment and a quickerand ambient
a quickerlight performance alignment and a quicker alignmentcondensation
An additional and a quicker heater
installation installation installation
sunlight are present installation forming on
prevents condensation
optical surfaces for areas with changing
temperature and humidity
Considerable savings in installation and cost

04 visit: ffeuk.com | +44 (0) 1462 444 740 visit: ffeuk.com | +44 (0) 1462 444 740 05
INGRESSION DETECTS DETECTS HIGH RESISTANCE
HIGH RESISTANCE DETECTS HIGH RESISTANCE
WORLD’S MOST TRUSTED BEAM

Fireray® One KEY FEATURES


Fireray® 5000 KEY FEATURES
The Beam Detector – Integrated visible laser and
auto-alignment for ultimate
Motorised Reflective – 
Allows for 2 detectors
per system controller
that aligns itself ease of alignment
– Integrated user interface
Auto-Aligning – 
Each detector configurable
from 8m to 100m
PN: 6010-000 – Prevent nuisance alarms with
Light Cancellation Technology™
Beam Smoke Detector – 
Separate fire and fault relays
per detector
With no specialist tools or knowledge needed which compensates for sunlight PN: 5000-101 (for up to 50m) – 
Integral laser alignment
for installation and operation, the Fireray ® One and artificial light sources PN: 5000-102 (for up to 100m) – 
Auto-align fast automatic
is a standalone beam detector that prioritises – Building Movement Tracking™ beam alignment
continuously maintains alignment The Fireray® 5000 is one of the most advanced – 
Contamination compensation
ease of installation. Using the Fireray ® One, it
when buildings settle or flex due – 
Low level system controller
couldn’t be easier to bring the benefits of beam fire detection products in the world, combining
to temperature variations – 
Logs the 50 most recent events
detection to your application: – Contamination compensation a transmitter/receiver in the same detector per detector
to correct for gradual build-up head with an automatic alignment motor. This – 
Programmable sensitivity
– Auto-Alignment - using the integrated user of dust on optics combination allows for quick, simple installation and fire thresholds
interface - just steer the laser onto the – Clean detectors quickly and and requires wiring and power at only one side – 
20mm cable gland knockouts
reflector, then at the flick of a switch, it aligns easily without affecting alignment on system controller
– Low power consumption; can
(the opposite side is covered by a reflector). – 
2-wire interface from system
itself. 8 times faster than previous detectors
– One person installation - everything be powered from the loop controller to detector
can be done by one person – Prevent interference between The Fireray® 5000 beam automatically
beams with dynamic beam compensates for environmental effects on IDEAL APPLICATIONS
– One standalone product - no specialist
phasing; install beams facing – Education and Heritage
tools required; minimal prior knowledge the beam signal, keeping the unit in the best
each other or in irregular Establishments
and training needed configurations possible working order. This is achieved through
– Industrial Units and Warehousing
– Detection range of up to 120m the combination of software (contamination – Aviation Hangers
compensation) and motorised realignment – Glass Atria in Hotels and
IDEAL APPLICATIONS of the beam. Retail Complexes
– Education and Heritage – Chemical Processing and
Establishments Storage Facilities
Other installation aids include the detector and
– Industrial Units and Warehousing
– Aviation Hangers controller first-fix systems, as well as a visible
– Glass Atria in Hotels laser to aid the user in alignment. The laser
and Retail Complexes also allows the reflective prism to be positioned
– Chemical Processing

Efficient
quickly and with confidence. This device can be
and Storage Facilities
installed by a single engineer, thus offering further
Operating range up to 50m or 120m saving on installation and commissioning costs.
with the Long Range Kit. PN: 1010-000
The system is fully customisable with both the
and effective UL
wide-area fire
®
alarm thresholds (sensitivity) and delay to alarm/
fault being controlled from the ground level

detection
system controller. The low level controller F

incorporates a LCD display, which offers a


full icon-based, easy-to-use interface unit.

06 visit: ffeuk.com | +44 (0) 1462 444 740 visit: ffeuk.com | +44 (0) 1462 444 740 07
WORLD’S MOST TRUSTED BEAM

Fireray® 3000 KEY FEATURES


Fireray® 3000 Exd KEY FEATURES
End-to-End Beam Smoke – R ange 5 to 120 metres,
configurable per set of detectors
End-To-End Explosive – 
Separate transmitter and
receiver unit certified to Exd
Detector – Light Cancellation Technology™
– Integral laser alignment
Proof Beam Smoke – 
Allows for 2 detectors per
system controller
PN: 3000-101
– 
in receiver
2-wire interface between
Detector – 
Separate fire and fault
relays per detector
controller and receiver PN: 3000-115 – 
R ange 5 to 80 metres,
The Fireray® 3000 is our solution to the most technically – Single and twin detector options configurable per set of detectors
challenged installation enviroments. The system uses – Separate fire and fault relays – 
Integral laser alignment
The Fireray® 3000 Exd is ideally suited for the
a paired set of transmitter/receiver heads to cover the per detector in receiver
– Low level controller protection of large areas, with potentially explosive – 
2-wire interface between
protected area. The transmitter emits a narrow beam
with LCD display atmospheres, against smoking fires. The Fireray® controller and receiver
of infra-red (IR) light in order to monitor for smoke
– Programmable sensitivity 3000 Exd comprises an infra-red transmitter and – 
Remote/low level controller
and is controlled using a compact low level controller. and fire threshold with LCD display (Safe Area)
receiver, both of which are ATEX-certified for use
Both detector heads (transmitter and receiver) have – Contamination compensation – 
Programmable sensitivity and
– First-fix design for transmitter, in group 2 hazardous areas. There is a separate, fire/fault delay
integral thumbwheels for ease of alignment. Using
receiver and controller safe area, wall-mounted remote/low level control – 
Contamination compensation
these thumbwheels provides a smooth and repeatable
– Multiple cable gland knockouts unit to allow adjustment and testing from a for dust and building movement
alignment process. for ease of wiring – 
Multiple cable gland knockouts
convenient non-hazardous location.
– Optional transmitter powering for ease of wiring
The Fireray® 3000 model has been designed to be from controller – 
Transmitter can be powered
The Fireray® 3000 Exd is designed for large from controller
installed by a single engineer. It incorporates a visible
IDEAL APPLICATIONS enclosures within oil rigs, refineries, ordnance – 
Complies with ATEX
laser as an alignment aid, with alignment LEDs offering
– Education and Heritage stores and similar premises. It provides an early and EN54:12
visual feedback. – 
Light Cancellation Technology™
Establishments warning of smouldering or strongly smoke-
– Industrial Units and Warehousing generative fires, which may not be picked
The Fireray® 3000 is fully customisable, with both the – Aviation Hangers IDEAL APPLICATIONS
up by flame detectors. – Petrochemical Installations
alarm thresholds (sensitivity) and delay to alarm/fault – Glass Atria in Hotels
and Retail Complexes – Ordinance Stores
being controlled from the low level controller. This – Flour mills
– Chemical Processing
controller incorporates a LCD display, which offers – Dusty Environments
and Storage Facilities
a full icon-based, easy-to-use interface unit. – Aviation Hangers
– Chemical Processing
and Storage Facilities
This controller enables ease of commissioning, testing
and maintenance of the beam detection system.

UL
®

08 visit: ffeuk.com | +44 (0) 1462 444 740 visit: ffeuk.com | +44 (0) 1462 444 740 09
WORLD’S MOST TRUSTED BEAM

FIRERAY®­¯ Fireray® One Fireray®


End-to-End:
ACCESSORIES¯ Product Range
Should typically be considered
To complement your Fireray® installation, we Our Fireray® range is the perfect solution for where there are reflective
protecting open areas with high ceilings such as
also offer a comprehensive range of accessories surfaces close to the beam’s
and tools for your specialist application. auditoriums, warehouses, airports and historical
buildings. With its easy first-fix system, and path,
Fireray or where the beam
Detector path
Reflector
knockout features, it allows for both ease of
Our standard range of accessories include: would be restricted due to fixed
wiring and quick alignment.
Protective Wire Cage Fireray One Back Box Prism Heater Anti-Condensation Reflective Detector obstructions.
PN: 1100-000 PN: 1260-000 PN: 1090-000 Heater Adjustment Bracket Fireray® One:
The beam detector that aligns itself
PN: 1060-000 PN: 1170-000
Fireray® 5000: Transmitter Receiver
Motorised reflective auto-aligning
Fireray 5000
®
beam smoke detector
To protect, Fireray® 3000:

clean and End-to-End


beam smoke detector

secure Fireray® 3000 Exd:


End-to-End explosive proof
beam smoke detector
Adjustment Bracket Protective Wire Cage Anti-Condensation 4 Reflector Reflector Wall Bracket Reflective:
PN: 5000-201 PN: 1000-018 Heater Adjustment Bracket PN: 1031-000 Most widely used and
PN: 5000-204 PN: 1050-000 requires less wiring,
which offers reduced
installation cost and time.
Fireray® 3000 Fireray® 3000 Exd

Fireray Detector Reflector

Flush Mount Plate Heater Bracket Adjustment Bracket Protective Wire Cage Detector Pack
Transmitter Receiver
PN: 3000-202 PN: 3000-204 PN: 3000-201 PN: 1000-019 PN: 3000-026

10 visit: ffeuk.com | +44 (0) 1462 444 740 visit: ffeuk.com | +44 (0) 1462 444 740 11
WORLD’S MOST TRUSTED BEAM

Fireray Range Fireray® One Fireray® 5000 Fireray® 3000 Fireray® 3000 Exd
Specifications 6010-000 5000-101 (50m). 5000-102 (100m) 3000-101 3000-115
MECHANICAL SPECIFICATION
Dimensions 130(W) x 181(H) x 134(D)mm - Detector. 100(W) x 100(H) x 9(D)mm - Single reflector 134(W) x 131(H) x 134(D)mm - Detector. 202(W) x 230(H) x 87(D)mm - System Controller 203(W) x 124(H) x 71.5(D)mm - System Controller 203(W) x 124(H) x 73.50(D)mm - System Controller
200(W) x 200(H) x 9(D)mm - Four reflectors 100(W) x 100(H) x 10(D)mm - Reflector 78(W) x 77(H) x 161(D)mm - Transmitter & Receiver 149(W) x 172(H) x 190(D)mm - Transmitter & Receiver
Weight 0.7kg - Detector. 0.1kg - Reflector 1.0kg - System controller. 0.5kg - Detector. 0.1kg - Reflector 606g - System controller. 207g - Transmitter & Receiver 606g - System controller. 3.7kg - Transmitter & Receiver Including brackets
Operation Range 5m to 50m from Detector to Reflector (Prism), 8m to 50m from Detector to Reflector with the 5000-101, 5m to 120m from Transmitter and Receiver 10m to 80m from Transmitter and Receiver
50m to 120m with Reflective Long Range Kit 50m to 100m from the Detector to Reflector with the 5000-102

Beam path clearance 1m in diameter from centre line between Detector and Reflector (Prism) 1m in diameter from centre line between Detector and Reflector (Prism) 60cm in diameter from centre line between Transmitter and Receiver 60cm in diameter from centre line between Transmitter and Receiver
Optical wavelength – smoke detection 850nm 850nm 850nm 850nm
Signal output Individual Alarm and Fault relays (VFCO) 2A @ 30 VDC Individual Alarm and Fault relays (VFCO) 2A @ 30 VDC Individual Alarm and Fault relays (VFCO) 2A @ 30 VDC Individual Alarm and Fault relays (VFCO) 2A @ 30 VDC
Cable gauge and type 2 core, dedicated, 0.5 to 1.6mm (24 to 14 AWG) 2 core, dedicated, 0.5 to 1.6mm (24 to 14 AWG) 2 core, dedicated, 0.5 to 1.6mm (24 to 14 AWG) 2 core, dedicated, 0.5 to 1.6mm (24 to 14 AWG)
System compatible with fireproof and non-fireproof cable meeting local installation standards 100m in Length from System Controller to Detector 100m in Length from System Controller to Detector 100m in Length from System Controller to Detector SPECIALIST­¯
Cable entry 3 knock-out locations capable of accepting M20, ½” or ¾” glands 4 x 20mm cable gland knock-outs on system controller 4 x 20mm cable gland knock-outs on system controller 3 x 20mm cable gland knock-outs on system controller
4 drill-out locations capable of accepting glands up to 21mm diameter APPLICATIONS­¯
ELECTRICAL SPECIFICATION
Operating voltage 14 to 36 VDC 14 to 36 VDC 12 to 36 VDC +/- 10% 12 to 36 VDC +/- 10% As manufacturers of Beam Smoke
Operating current all operational modes 5mA to 33mA (constant) 5mA to 6mA for 1 Detector. 7.5mA to 8.5mA for 2 Detectors 14mA (constant) with 1 or 2 Receivers 14mA (constant) with 1 or 2 Receivers Detectors technology, our experts
35mA to 37mA for alignment modes with 1 or 2 Detectors 8mA per Transmitter 8mA per Transmitter can provide you with fire protection
Contact Voltage - Fire & Fault relays (VFCO) VFCO, 2A at 30 VDC resistive VFCO, 2A at 30 VDC resistive VFCO 2A at 30 VDC resistive VFCO, 2A at 30 VDC resistive technology for any type of application.
Contact Current - Fire & Fault relays (VFCO) 10mA at 20mV (min) 1A at 30 VDC (max) 10mA at 20mV (min) 1A at 30 VDC (max) 10mA at 20mV (min) 1A at 30 VDC (max) 10mA at 20mV (min) 1A at 30 VDC (max) In addition to our design consultation
PROGRAMMABLE USER SETTINGS service, we can also provide you with a
complete technical design service, along
Alarm response threshold levels 25% / 1.25dB – Fastest response to smoke. 35% / 1.87dB – Default value 35% (default) 1 min (min) 5 min (typical) 59 min (max) - Laser Time-out 1 min (min) 5 min (typical) 59 min (max) - Laser Time-out
55% / 3.46dB – High immunity to false alarms, slow response to smoke 10% / 0.45dB (min) - Fastest response to smoke 35% (min) 60% (typical) - Response Sensitivity/ Threshold 25% (min) 35% (typical) 60% (max) - Response Sensitivity/ Threshold with drawings to assist you with your
85% / 8.23dB – Highest immunity to false alarms, slowest response to smoke 60% / 3.98dB (max) - Highest immunity to false alarms, installation.
Configured via the integrated user interface slowest response to smoke
Delay to Alarm/fault 10 seconds for momentary partial obstruction of the beam path 10 seconds (default). 2 seconds (min). 30 seconds (max) 10 seconds (default). 2 seconds (min). 30 seconds (max) 10 seconds (default). 2 seconds (min). 30 seconds (max)
USER FEATURES
Alignment Aid/ Tool Laser Laser Laser Laser

HELP FROM FFE­¯


System status indication Green LED = Normal operation Green LED = Normal operation Red LED = Fire (control unit) Red LED = Fire (control unit)
Red LED = Alarm condition Red LED = Alarm condition Amber LED = Fault (control unit) Amber LED = Fault (control unit)
Yellow LED = Fault condition Yellow LED = Fault condition Green LED = System OK (control unit) Green LED = System OK (control unit)
ENVIRONMENTAL SPECIFICATIONS As additional support, we provide
Operating temperature -20°C to +55°C -10°C to +55°C -20°C to +55°C (UL). -10°C to +55°C (EN54) -10°C to +55°C comprehensive training programmes for
Storage temperature -40°C to +85°C -40°C to +85°C -40°C to +85°C -40°C to +85°C the Fireray® range, tailored to suit your own
Relative humidity (non-condensing) 0 to 93% 0 to 93% 0 to 93% 0 to 93% specific requirements. We are happy to train
individuals or your entire installation team.
IP rating IP55 IP54 IP54 (Controller) IP54 (Controller). IP66 (Transmitter/Receiver)
Housing flammability rating: UL94 V0 UL94 V0 UL94 V2 PC UL94 V2 PC Contact us at:
OPTICAL SPECIFICATIONS e technical@ffeuk.com
Fault level / Rapid obscuration (∆ ≤ 2 seconds) ≥85% ≥87% ≥85% ≥85%
Maximum angular alignment Range ±4.5° - Detector (±70° with adjustment bracket accessory) ±3.5° - Detector ±10° - Receiver and Transmitter ±10° - Receiver and Transmitter
Maximum angular misalignment ±0.5° - Detector ±0.41° - Detector ±0.7° - Transmitter. ±2.5° - Receiver ±0.7° - Transmitter. ±2.5° - Receiver
Maximum angular misalignment of Reflector (Prism) ±5° ±5° N/A N/A

12 visit: ffeuk.com | +44 (0) 1462 444 740 visit: ffeuk.com | +44 (0) 1462 444 740 13
WORLD’S MOST TRUSTED BEAM

PROTECTING LIVES. INSTALLATIONS¯


WORLDWIDE¯
Dubai International Airport, Dubai

Doha International Airport, Qatar

 ZOO NEGARA, MALAYSIA  COPENHAGEN HOSPITAL, DENMARK Wroclaw Airport, Poland

Zoo Negara’s panda enclosure in Kuala Lumpur One of Copenhagen’s leading hospitals has
Barclays Center Arena, USA

has installed FFE’s Fireray® beam smoke been fitted with four Fireray® 5000 advanced
detectors in the panda enclosure and viewing infra-red beam smoke detectors as part of its fire Van Andel Arena, USA

area. The detectors are designed to trigger a protection system. Serving nearly half a million Worcester Cathedral, UK

smoke spill fan in the event of a fire. Because patients, the hospital has grown in size over the
of the atrium’s high ceiling, conventional smoke last few years. The detectors were selected as Portsmouth Historic Dockyard, UK

detectors were not suitable for this installation, the ideal choice to protect the building in the Hyundai Corporate Offices, USA

a sprinkler system was also not an option due most efficient way.
to their slower response times. Beam detectors National Portrait Gallery, UK

were therefore best for this installation due to  WINDSOR CASTLE, UK Vienna City Hall, Austria

their extremely fast response times. The longest-occupied palace in Europe
Longtan Hydropower Station, China

and one of the most visited tourist attraction
 VELODROME, UK in England is being protected by 18 of FFE’s Shree Swaminarayan Temple,
 
Derby Velodrome has been fitted with nine Fireray® beam smoke detectors. They are LA, USA
Fireray® 5000 advanced infra-red beam smoke installed throughout the palace, from banqueting
Socotab Tobacco Warehouse,
 
detectors as part of its fire protection system. rooms, atria and kitchens to hallways, stairwells
They provide wide area detection and are used and staff accommodation areas.
Bulgaria
when it is impractical, inappropriate or not cost WASSIT power station, Iran

effective to use traditional point-type detectors.
Blenheim Place, Oxfordshire, UK

They are ideally suited to large arenas with high
ceilings, such as the Derby Velodrome, as they Pathé Arena, Amsterdam

enable coverage of a large area at minimal cost.
Budapest Central Wastewater
 
Treatment Plant, Hungary
Parliament of Republic of Macedonia,
 
Macedonia
‘DISCREET Detroit Wastewater Treatment
 
INSTALLATION, plant, USA

MINIMAL
DISRUPTION’

14 visit: ffeuk.com | +44 (0) 1462 444 740 visit: ffeuk.com | +44 (0) 1462 444 740 15
Worldwide Technical Support US Sales and Distribution Head Office HQ
TECHNICAL SUPPORT¯ FFE Limited FFE Limited
e technical@ffeuk.com 1455 Jamike Ave Ste 200 9 Hunting Gate
Erlanger Hitchin, Hertfordshire
FFE Ltd is proud to be able to offer a high level of Technical Support to all our KY 41018-3147 SG4 0TJ
customers, from distributors to end-users. We can advise with any aspect of USA England
our Fireray® Optical Beam Smoke Detectors and Talentum® Flame Detectors.
t +1 859 957 1570 t +44 (0) 1462 444 740
Our Technical Support includes: e america@ffeus.com e sales@ffeuk.com
www.ffeus.com www.ffeuk.com
Reviewing and advising on correct installation and alignment of FFE Beam Detectors
and Flame Detectors.

Troubleshooting problems during the operation of Beam and Flame Detectors WORLDWIDE¯
after correct installation and alignment Advising the attributes of various types
of Beam and Flame Detectors to suit different applications. Explaining good
installation and operation practice for Beam and Flame Detectors. OFFICES¯
On a proactive level, Fireray® or Talentum® product training is available to any FFE
customer including installers, distributors and end users and can be arranged with
your FFE Sales Manager or by contacting FFE directly. Each training course is modular
and the duration can be agreed according to the customer’s requirements.

These personalised training courses can be targeted to all levels; Directors, Sales
& Marketing or Technical, and are tailored for mixed audiences too. They include
information on Technical Support as well as Troubleshooting for advanced users.

In the UK, courses are typically delivered at the FFE Headquarters in Hitchin, Herts.
For other venues, including overseas, please discuss with your Sales Manager.

Certificates

OHSAS 18001:2017 OHS 580021


RMA Request
Should you need to return a product to us,
please email warranty@ffeuk.com
Middle East Sales Office India Sales Office
Dubai Bangalore
UAE India
e middleeast@ffeuk.com e india@ffeuk.com
www.ffeuk.com www.ffeuk.com

Document No: 24-0306-02