1. BEFORE INSTALLATION
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
• Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.
• Be sure to observe the warnings and cautions specified here as they include important items related to safety.
• After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.
WARNING (Could lead to death, serious injury, etc.)
N Do not install the unit by yourself (user). N Do not install the unit in a place where inflammable gas N Do not discharge the refrigerant into the atmosphere. If
Incomplete installation could cause fire, electric shock, injury may leak. refrigerant leaks during installation, ventilate the room.
due to the unit falling, or leakage of water. Consult the deal- If gas leaks and accumulates in the area around the unit, it If refrigerant comes in contact with a fire, harmful gas could
er from whom you purchased the unit or a qualified installer. could cause an explosion. be generated.
N Perform the installation securely referring to the instal- N Do not use intermediate connection of the power cord N Check that the refrigerant gas does not leak after instal-
lation manual. or the extension cord and do not connect many devices lation has been completed.
Incomplete installation could cause fire, electric shock, injury to one AC outlet. If refrigerant gas leaks indoors, and comes into contact with
due to the unit falling, or leakage of water. It could cause a fire or an electric shock due to defective the flame of a fan heater, space heater, stove, etc., harmful
N When installing the unit, use appropriate protective contact, defective insulation, exceeding the permissible cur- substances will be generated.
equipment and tools for safety. rent, etc. N Use appropriate tools and piping materials for installation.
Failure to do so could cause injury. N Be sure to use the parts provided or specified parts for The pressure of R410A is 1.6 times more than R22. Not us-
N Install the unit securely in a place which can bear the the installation work. ing appropriate tools or materials and incomplete installation
weight of the unit. The use of defective parts could cause an injury or leakage of could cause the pipes to burst or injury.
If the installation location cannot bear the weight of the unit, water due to a fire, an electric shock, the unit falling, etc. N When pumping down the refrigerant, stop the compres-
the unit could fall causing injury. N When plugging the power supply plug into the outlet, make sor before disconnecting the refrigerant pipes.
N Electrical work should be performed by a qualified, expe- sure that there is no dust, clogging, or loose parts in both If the refrigerant pipes are disconnected while the compressor is
rienced electrician, according to the installation manual. the outlet and the plug. Make sure that the power supply running and the stop valve is open, air could be drawn in and the
Be sure to use an exclusive circuit. Do not connect other plug is pushed completely into the outlet. pressure in the refrigeration cycle could become abnormally high.
electrical appliances to the circuit. If there is dust, clogging, or loose parts on the power supply This could cause the pipes to burst or injury.
If the capacity of the power circuit is insufficient or there is incom- plug or the outlet, it could cause electric shock or fire. If loose N When installing the unit, securely connect the refriger-
plete electrical work, it could result in a fire or an electric shock. parts are found on the power supply plug, replace it. ant pipes before starting the compressor.
N Earth the unit correctly. N Attach the electrical cover to the indoor unit and the If the compressor is started before the refrigerant pipes are
Do not connect the earth to a gas pipe, water pipe, lightning rod service panel to the outdoor unit securely. connected and when the stop valve is open, air could be
or telephone earth. Defective earthing could cause electric shock. If the electrical cover of the indoor unit and/or the service panel drawn in and the pressure in the refrigeration cycle could
N Do not damage the wires by applying excessive pres- of the outdoor unit are not attached securely, it could result in a become abnormally high. This could cause the pipes to
sure with parts or screws. fire or an electric shock due to dust, water, etc. burst or injury.
Damaged wires could cause fire or electric shock. N When installing, relocating, or servicing the unit, make N Fasten a flare nut with a torque wrench as specified in
N Be sure to cut off the main power in case of setting up sure that no substance other than the specified refriger- this manual.
the indoor P.C. board or wiring works. ant (R410A) enters the refrigerant circuit. If fastened too tight, a flare nut may break after a long pe-
Failure to do so could cause electric shock. Any presence of foreign substance such as air can cause riod and cause refrigerant leakage.
N Use the specified wires to connect the indoor and abnormal pressure rise and may result in explosion or injury. N The unit shall be installed in accordance with national
outdoor units securely and attach the wires firmly to the The use of any refrigerant other than that specified for the wiring regulations.
terminal block connecting sections so the stress of the system will cause mechanical failure, system malfunction, or
wires is not applied to the sections. Do not extend the unit breakdown. In the worst case, this could lead to a seri-
wires, or use intermediate connection. ous impediment to securing product safety.
Incomplete connecting and securing could cause fire.
CAUTION (Could lead to serious injury in particular environments when operated incorrectly.)
N Install an earth leakage breaker depending on the instal- If there is defect in the drainage/piping work, water could N Do not install the outdoor unit where small animals may
lation place. drop from the unit, soaking and damaging household goods. live.
If an earth leakage breaker is not installed, it could cause N Do not touch the air inlet or the aluminum fins of the If small animals enter and touch the electric parts inside the
electric shock. outdoor unit. unit, it could cause a malfunction, smoke emission, or fire.
N Perform the drainage/piping work securely according to This could cause injury. Also, advise user to keep the area around the unit clean.
the installation manual.
54 mm or more/
<Indoor unit> wire (A) from contacting Wall hole
100 m
metal parts in the wall and sleeve (C)
(using spacer)
m Fix the pipe to wall
(1) Installation plate 1 or mo
re to prevent damage by with pipe fixing
Installation plate fixing screw rodents in case the wall is band (E).
(2) 5 hollow.
4 × 25 mm
Cut off the Pipe fixing band
110 m
(3) Remote controller holder 1 or mo m extra length. (E)
re
Fixing screw for (3) 3.5 × 16 mm Fixing screw
(4) 2
(Black) (F)
or more
(5) Battery (AAA) for (6) 2
10 mm
(6) Wireless remote controller 1
After the leak test, apply Outdoor unit installation
Felt tape insulating material tightly
(7) 1 840 mm
(For left or left-rear piping) so that there is no gap. 169 mm 500 mm
(8) Air cleaning filter 2
(D) When the piping is to be at- Air inlet
(7) (C) tached to a wall containing
PARTS TO BE PROVIDED
360 mm
metals (tin plated) or metal
330 mm
392 mm
AT YOUR SITE (G) netting, use a chemically
(A) Indoor/outdoor unit connecting wire* 1 (E) treated wooden piece 20
(B) Extension pipe 1 mm or thicker between the
wall and the piping or wrap Air outlet
(C) Wall hole sleeve 1 (F) 7 to 8 turns of insulation vi- 2/4-10 mm × 21mm slot 40 mm
(D) Wall hole cover 1 nyl tape around the piping.
(E) Pipe fixing band 2 to 5 To use existing piping, per-
(F) Fixing screw for (E) 4 × 20 mm 2 to 5 form COOL operation for
30 minutes and pump down
(G) Piping tape 1 before removing the old air
500 mm
(H) Putty 1 or more conditioner. Remake flare
Drain hose according to the dimension
(I) (or soft PVC hose, 15 mm inner 1 or 2 for new refrigerant.
diameter or hard PVC pipe VP16) mm
10 100more
(J) Refrigeration oil 1 or m0 mm or
ore (K)
(K) Power supply cord* 1 (A)
(I)
* Note:
Place indoor/outdoor unit connecting wire (A)
and power supply cord (K) at least 1 m away (B)
mm 35
from the TV antenna wire. 500more or m0 mm
o r ore
Ceiling 54 mm or more
130 mm or more for left and left
Bind the line to the center hole. back piping (using spacer)
Installation plate (1) Lead wire
Level
Indoor/outdoor unit
connecting wire (A)
100 mm 110 mm
or more or more Indoor terminal block
• For future servicing, give extra length to the
Wall 100 mm Wall
connecting wires. Earth wire
• Make earth wire a little longer than others. (More (green/yellow)
than 60 mm)
• Do not fold the excess wire, or cram it into small
space. Take caution not to damage the wires. Indoor/outdoor
Note: Do not place the wires between the in- unit
door unit and the installation plate (1). Damaged connecting wire
Insert Align the Center of
Fixing screw (2) Align the plumb wire could cause heat generation or fire. (A)
the scale with ø 65 mm hole
line with the scale. *
mark . the line. *
Plumb
* Same for left hole.
Outdoor terminal block
2-3. CONNECTING WIRES FOR INDOOR UNIT 2-4. PIPE FORMING AND DRAIN PIPING Liquid pipe
You can connect indoor/outdoor lead wire without removing the front panel. Pipe Forming Gas pipe
1) Open the front panel. • Place the drain hose below the refrigerant piping.
2) Remove VA clamp. • Make sure that the drain hose is not heaved or snaked. Indoor/outdoor unit
3) Pass indoor/outdoor unit connecting wire (A) from the back of the indoor unit and proc- • Do not pull the hose when applying the tape. connecting wire (A)
ess the end of the wire. • When the drain hose passes the room, be sure to wrap Felt tape (7)
insulation material (obtainable at a store) around it. Piping tape (G)
Rear, right, or downward piping Left or left-rear piping
Cut off in case of
1) Put the refrigerant piping and the drain hose right piping. Note:
together, then firmly apply piping tape (G) Be sure to reattach the drain
Piping tape (G) Cut off in case of left
from the end. hose and the drain cap in case piping.
2) Insert the piping and the drain hose into the Cut off in case of of left or left-rear piping. Felt tape (7)
downward piping. Drain cap
wall hole sleeve (C), and hook the upper part Otherwise, it could cause drops
of the indoor unit on the installation plate (1). of water to drip down from the
3) Check if the indoor unit is hooked securely on the installation plate (1) by moving drain hose.
the unit to left and right. Drain cap
4) Thrust the lower part of the indoor unit into the installation plate (1). 1) Put the refrigerant piping and the drain hose together,
then firmly apply felt tape (7) from the end.
Felt tape (7) overlap width should be 1/3 the tape
Drain Piping
width. Use a bandage stopper at the end of felt tape (7).
• If the extension drain hose has to pass through a room, be sure to wrap it with com-
2) Pull out the drain cap at the rear right of the indoor unit. Fig. 1
mercially sold insulation.
(Fig. 1)
• The drain hose should point downward for easy drain flow. (Fig. 1)
• Hold the convex section at the end and pull the
• If the drain hose provided with the indoor unit is too short, connect it with drain hose (I)
that should be provided at your site. (Fig. 2) drain cap.
• When connecting the drain hose to the hard vinyl chloride pipe, be sure to insert it 3) Pull out the drain hose at the rear left of the indoor unit.
securely into the pipe. (Fig. 3) (Fig. 2) Drain hose
• Hold the claw marked by the arrows and pull out the
drain hose forward. Fig. 2
Drain Drain hose
hose
4) Put the drain cap into the section to which the drain
Hard vinyl chloride
70 cm or
pipe I.D. 30 mm
hose is to be attached at the rear of the indoor unit.
Downward more (Fig. 3)
slope
Soft hose • Insert not sharp-edged tools such as screwdrivers
I.D. 15 mm Insert cap
securely
into the hole at the end of the cap and insert the cap
Different fully into the drain pan. Fig. 3
diameter joint 5) Insert the drain hose fully into the drain pan at the rear Drain hose
Fig. 1 Fig. 2 Fig. 3 right of the indoor unit. (Fig. 4)
• Check if the hose is hooked securely to the projec-
tion of its inserting part at the drain pan.
Do not make drain p
piping
p g as shown below. Fig. 4
6) Insert the drain hose into wall hole sleeve (C), and
hook the upper part of indoor unit on installation plate
Do not raise Accumulated
A (1). Then, move the indoor unit completely to the left in
drain water Tip of drain At least order to make placing the piping in the back space of
hose dipped 50 mm the unit easier.
Air
in water
er gap
7) Cut out a piece of cardboard from the shipping box, roll
it up, hook it onto the back rib, and use it as a spacer 5
Water Water Water to lift the indoor unit. (Fig. 5)
leakage leakage Waving leakage Ditch 8) Connect the refrigerant piping with the extension pipe (B).
9) Thrust the lower part of the indoor unit into the installation plate (1).
3) Run the vacuum pump. (Vacuumize for more than 15 minutes.) 4-4. EXPLANATION TO THE USER
4) Check the vacuum with gauge manifold valve, then close gauge manifold valve, and • Using the OPERATING INSTRUCTIONS, explain to the user how to use the air condi-
stop the vacuum pump. tioner (how to use the remote controller, how to remove the air filters, how to remove
5) Leave as it is for one or two minutes. Make sure pointer gauge manifold valve remains or put the remote controller in the remote controller holder, how to clean, precautions
in the same position. Confirm that pressure gauge shows –0.101 MPa [Gauge] (–760 for operation, etc.)
mmHg). • Recommend the user to read the OPERATING INSTRUCTIONS carefully.
6) Remove gauge manifold valve quickly from service port of stop valve.
7) After refrigerant pipes are connected and evacuated, fully open all stop valves on both
sides of gas pipe and liquid pipe. Operating without fully opening lowers the perform-
ance and this causes trouble.
8) Refer to 1-3., and charge the prescribed amount of refrigerant if needed. Be sure to
charge slowly with liquid refrigerant. Otherwise, composition of the refrigerant in the
system may be changed and affect performance of the air conditioner.
9) Tighten cap of service port to obtain the initial status.
10) Leak test
CAÅN THAÄN (coù theå daãn ñeán thöông toån nghieâm troïng trong tröôøng hôïp laép ñaët khoâng ñuùng)
O Laép boä ngaét roø noái ñaát tuøy thuoäc vaøo vò trí laép ñaët. Neáu coù sai soùt, nöôùc coù theå roø ræ töø maùy ñieàu hoøa vaø O Khoâng laép ñaët boä phaän ñieàu hoøa ngoaøi phoøng nôi
Neáu khoâng laép boä ngaét roø noái ñaát coù theå seõ gaây ra ñieän laøm hö hoûng ñoà duøng trong nhaø. ñang coù caùc ñoäng vaät nhoû sinh soáng.
giaäät.
g O Khoâng ñöôïc chaïm tay vaøo cöûa huùt hoaëc caùnh nhoâm Neáu caùc ñoäng vaät naøy ñeán ggaàn vaø chaïïm vaøo caùc linh
O Laép oáng thoaùt nöôùc/noái oáng an toaøn theo höôùng taûn nhieät cuûa boä phaän ñieàu hoøa ngoaøi phoøng. kieän ñieän beân trong maùy ñieàu hoøa coù theå daãn ñeán hö
daãn laép ñaët. Ñieàu naøy coù theå gaây ra thöông toån. hoûn g maù y, laøm phaùt sinh khoùi hoaëc gaây chaùy noå. Ngoaøi
ra, neân veä sinh khu vöïc xung quanh maùy ñieàu hoøa.
1-3. THOÂNG SOÁ KYÕ THUAÄT Söï cheânh leäch giöõa chieàu daøi vaø chieàu cao oáng
Thoâng soá kyõ thuaät Kích thöôùc oáng
Kieåu maùy Nguoàn ñieän *1 Chieàu daøi toái ña cuûa oáng 30 m
cuûa daây ñieään *2 ( ä daøy *3, *4))
(ñoä
Daây noái boä phaän Chieàu cao toái ña cuûa oáng 15 m
Boä phaän ñieàu Boä phaän ñieàu Ñieän aùp ñònh möùc Taàn soá Coâng suaát Nguoàn ñieän trong/ngoaøi phoøng Khí/chaát loûng
hoøa trong phoøng hoøa ngoaøi phoøng boä ngaét Soá löôïng co oáng toái ña *5, *6 10
3-loõi 4-loõi ø12,7 / 6,35 mm Ñieàu chænh moâi chaát laøm laïnh A*7 20 g/m
MSY-GH18VA MUY-GH18VA 220 V 50 Hz 16 A
2,0 mm2 1,0 mm2 (0,8 mm) Ñoä daøy taám caùch nhieät *8, *9 8 mm
*1 Noái coâng taéc ñieän coù khe hôû hôn 3mm ñeå ngaét nguoàn *4 Söû duïng oáng ñoàng hoaëc oáng hôïp kim ñoàng khoâng Moâi chaát laøm laïnh naïp theâm = A x (chieàu daøi oáng(m)
ñieän. (Khi nguoàn ñieän bò ngaét, noù seõ ngaét toaøn boä caùc ñöôïc haøn noái. – 7)
pha.) *5 Caån thaän ñeå traùnh laøm eùp hoaëc beû oáng khi laép ñöôøng *8 Vaät lieäu caùch nhieät: Xoáp caùch nhieät coù khoái löôïng
*2 Söû duïng daây ñieän theo tieâu chuaån thieát keá 60245 IEC oáng cong. rieâng 0,045.
57. *6 Baùn kính uoán cong cuûa oáng daãn moâi chaát laøm laïnh *9 Phaûi söû duïng lôùp caùch nhieät coù ñoä daøy theo quy ñònh.
*3 Khoâng neân söû duïng oáng coù ñoä daøy nhoû hôn quy phaûi töø 100mm trôû leân. Quaù daøy coù theå daãn ñeán vieäc laép ñaët khoâng hôïp lyù
ñònh. Vì aùp suaát trong oáng raát lôùn. *7 Neáu chieàu daøi oáng vöôït quaù 7m, caàn phaûi naïp theâm boä phaän ñieàu hoøa trong phoøng, neáu khoâng ñuû daøy seõ
moâi chaát laøm laïnh (R410A). (Khoâng caàn naïp theâm gaây ra hieän töôïng nhoû söông.
neáu chieàu daøi oáng nhoû hôn 7m.))
1-4. SÔ ÑOÀ LAÉP ÑAËT Chaéc chaén söû duïng oáng Boää pphaän Naép che loã töôøng (D)
loàng loã töôøng (C) ñeå traùnh ñieàu hoøa
CAÙC PHUÏ KIEÄN trong phoøong
n Laøm kín khe hôû loã
mieáng ñeäm)
100m töôøng (C) Coá ñònh oáng vaøo
(1) Taám treo maùy ñieàu hoøa 1 m kim loaïi beân trong töôøng töôøng vôùi baêng keo
(2) Vít ñònh vò taám treo 4 × 25mm 5 vaø ñeå traùnh bò hö haïi daây coá ñònh oáng (E).
(3) Giaù giöõ remote ñieàu khieån töø xa 1 do moái moït.
Caét boû phaàn Baêng keo coá
Treân
Vít ñònh vò (3) 3,5 × 16mm 110m chieàu daøi dö. ñònh oáng (E)
(4) 2 m
(maøu ñen)
Vít ñònh
(5) Pin (AAA) (6) 2 vò (F)
Treân 10mm
(6) Remote ñieàu khieån töø xa khoâng daây 1
Baêng keo (duøng cho vieäc noái oáng
(7) 1 Sau khi kieåm tra roø ræ, boâi Laép ñaët boä phaän ñieàu hoøa ngoaøi phoøng
beân traùi hoaëc beân traùi phía sau)
vaät lieäu caùch nhieät phuû 840mm
(8) Taám loïc saïch khoâng khí 2 toaøn boä beà maët oáng. 169mm 500mm
NHÖÕNG LINH KIEÄN ÑÖÔÏC CUNG CAÁP TAÏI (D) Khi ñöôøng oáng ñöôïc gaén
Cöûa hut khí
CHOÃ (7) (C) vaøo töôøng coù chöùa kim
loaïi (maï thieát) hoaëc löôùi
360mm
330mm
392mm
Daây noái boä phaän ñieàu hoøa trong (G) kim loaïi, duøng goã coù ñoä
(A) 1
phoøng/ngoaøi phoøng* (E) daøy hôn 20mm ñöôïc xöû lyù
(B) OÁng noái daøi 1 hoùa chaát ñeå ñaët vaøo giöõa
oáng vaø töôøng hoaëc quaán
(C) OÁng loàng loã töôøng 1 (F) oáng töø 7 ñeán 8 voøng baèng Cöûa thoaùt khí
(D) Naép che loã töôøng 1 Khe roäng 2/4-10mm × 21mm 40mm
keo caùch nhieät vinyl. Ñeå
(E) Baêng coá ñònh oáng 2 ñeán 5 söû duïng ñöôøng oáng hieän
(F) Vít ñònh vò (E) 4 × 20mm 2 ñeán 5 höõu, cho maùy hoaït ñoäng
ôû cheá ñoä COOL trong 30
(G) Baêng keo noái oáng 1
Treân phuùt vaø bôm xuoáng tröôùc
(H) Keo treùt töôøng 1 500mm khi thaùo maùy ñieàu hoøa cuõ
OÁng xaû ra. Thay môùi oáng loe phuø
(I) (hoaëc oáng PVC meàm ñöôøng kính trong 1 ñeán 2 hôïp vôùi theå tích moâi chaát
15mm hoaëc oáng PVC cöùng VP 16) laøm laïnh môùi.
ân
Tre Tre 0mm
(J) Daàu maùy ñieàu hoøa 1 100 ân 10
m m (K)
(K) Daây nguoàn* 1 (A)
(I)
* Chuù yù:
Laép daây noái boä phaän ñieàu hoøa trong/ngoaøi (B)
phoøng (A) vaø daây nguoàn (K) caùch daây anten ân Tre
Tre0mm 350 ân
ít nhaát 1m. 50 m m
3-2. COÂNG VIEÄC LOE OÁNG Noái oáng ñieàu hoøa trong phoøng
1) Caét oáng ñoàng moät caùch chính xaùc baèng dao caét oáng. Noái caû ñöôøng oáng daãn chaát loûng vaø chaát khí vaøo boä phaän ñieàu hoøa trong phoøng.
(Hình 1,2) OÁng ñoàng • Boâi moät lôùp moûng daàu maùy laïnh ((J)) leân beà maët cuûa oáng.
2) Laøm saïch toaøn boä ba vôù theo tieát dieän caét oáng. • Ñeå noái oáng, tröôùc tieân canh chænh thaúng taâm, sau ñoù xieát chaët ñai oác loe 3 ñeán 4 voøng.
(Hình 3) Hình 1 • AÙp duïng baûng thoâng soá löïc xieát döôùi ñaây cho caùc ñoaïn noái boä phaän ñieàu hoøa trong phoøng,
• Höôùng ñaàu oáng xuoáng sau khi ñaõ laøm saïch ñeå vaø xieát chaët baèng hai côø leâ löïc. Xieát quaù chaët coù theå laøm hö hoûng ñoaïn oáng loe.
traùnh ba vôù rôi vaøo trong oáng.
3) Thaùo oáng loe ñöôïc gaén vaøo boä phaän ñieàu hoøa trong Noái oáng boä phaän ñieàu hoøa beân ngoaøi phoøng
Toát Khoâng toát
vaø ngoaøi phoøng, sau ñoù ñaët vaøo caùc oáng daãn ñaõ Noái oáng vaøo ñaàu noái van chaën chaën cuûa boä phaän ñieàu hoøa
ñöôïc laøm saïch ba vôù. (khoâng theå ñaët vaøo ñöôïc sau ngoaøi phoøng theo caùch thöùc nhö ñaõ thöïc hieän ñoái vôùi boä phaän
khi loe.) ñieàu hoøa trong phoøng.
4) Coâng vieäc loe (Hình 4,5). Giöõ chaët oáng ñoàng theo • Ñeå xieát chaët, duøng côø leâ löïc hoaëc chìa vaën vôùi löïc xieát töông
chieàu nhö trong hình veõ. Choïn A mm töø baûng tuøy töï nhö aùp duïng cho boä phaän ñieàu hoøa trong phoøng.
Bò Khoâng Coù ba vôù
thuoäc vaøo duïng cuï baïn söû duïng. nghieâng nhaün
5) Kieåm tra CAÛNH BAÙO
• So saùnh oáng ñaõ ñöôïc loe roäng vôùi hình 6. Khi laép ñaët maùy ñieàu hoøa, noái oáng daãn moâi chaát laøm laïnh
Hình 2 tröôùc khi khôûi ñoäng maùy neùn.
• Neáu coù sai soùt, caét boû ñoaïn vöøa ñöôïc loe vaø laøm
laïi.
Duïng cuï loe 3-4. CAÙCH NHIEÄT VAØ BOÏC ÑÖÔØNG OÁNG
1) Boïc ñaàu noái oáng baèng voû boïc oáng.
Ba vôù OÁng ñoàng
2) Ñoái vôùi boä phaän ñieàu hoøa ngoaøi phoøng, neân caùch nhieät taát caû ñöôøng oáng coù van ñieàu tieát.
Dao khoeùt döï phoøng
3) Söû duïng baêng quaán oáng (G), boïc oáng töø ñaàu vaøo cuûa boä phaän ñieàu hoøa ngoaøi phoøng.
Thieát bò
caét ong
cat oáng
• Duøng keo dính ñeå daùn ñaàu baêng keo boïc oáng (G).
• Khi phaûi laép ñöôøng oáng treân traàn nhaø, phoøng veä sinh hoaëc khi nhieät ñoä vaø ñoä aåm
keïp chaët Loaïi ñai oác xieát quaù cao, haõy quaán theâm vaät lieäu caùch nhieät baùn ngoaøi thò tröôøng ñeå ngaên hieän
Hình 3 Hình 4 töôïng ngöng tuï nöôùc trong ñöôøng oáng.
4. QUY TRÌNH XAÛ KHÍ, KIEÅM TRA ROØ RÆ VAØ CHAÏY THÖÛ
4-1. QUY TRÌNH XAÛ KHÍ VAØ KIEÅM TRA ROØ RÆ 4-2. CHAÏY THÖÛ
1) Môû cöûa van chaën treân thaønh oáng daãn khí cuûa boä phaän ñieàu hoøa ngoaøi trôøi (van 1) Caém daây nguoàn vaøo oå caém ñieän vaø/hoaëc hoaëc baät CB.
chaën seõ khoâng hoaït ñoäng nhö traïng thaùi ban ñaàu khi xuaát xöôûng, hoaøn toaøn bò Kieåm tra xem ñeøn LED coù saùng khoâng. Neáu ñeøn LED
ñoùng naép.) nhaáp nhaùy, kieåm tra xem thanh höôùng gioù ngang coù
2) Noái van oáng noái coù ñoàng hoà vaøo coång vaän haønh cuûa van chaën treân oáng daãn khí cuûa laép ñaët hôïp lyù khoâng. Tham khaûo phaàn höôùng daãn söû
boä phaän ñieàu hoøa ngoaøi phoøng. duïng ñeå bieát theâm chi tieát.
2) Nhaán E.O.SW. Chaïy thöû trong voøng 30 phuùt. Neáu cöù
moãi 0,5 giaây, ñeøn chæ baùo phía treân hoaït ñoäng nhaáp
AÙp keá ño hôïp chaát nhaùy, kieåm tra daây noái boä phaän ñieàu hoøa trong phoøng/
–0,101 MPa (cho R410A)
*4 ñeán 5 voøng Naép van chaën (–760 mmHg) ngoaøi phoøng (A) xem coù ñaáu noái sai hay khoâng. Sau
(löïc xieát 19,6 ñeán Van chaën AÙp keá (cho R410A) khi chaïy thöû, cheá ñoä khaån caáp (24ºC) seõ khôûi ñoäng. Coâng taéc ñieàu
*Ñoùng 29,4 Nm, 200 duøng cho
*Môû Van oáng noái 3) Ñeå döøng hoaït ñoäng, nhaán E.O.SW nhieàu laàn cho ñeán khieån döï phoøng
ñeán 300 kgf•cm) CHAÁT LOÛNG (E.O.SW)
coù ñoàng hoà khi ñeøn LED taét. Tham khaûo phaàn höôùng daãn söû duïng
Tay naém
(cho R410A) ñeå bieát theâm chi tieát.
phía döôùi Tay naém phía treân
Côø leâ luïc giaùc Kieåm tra tín hieäu nhaän cuûa remote ñieàu khieån (baèng tia hoàng ngoaïi)
Van chaën OÁng naïp Nhaán nuùt ON/OFF ôû remote ñieàu khieån töø xa (6) vaø kieåm tra aâm thanh phaùt ra töø boä
duøng cho (cho R410A)
KHÍ
phaän ñieàu hoøa trong phoøng. Nhaán nuùt ON/OFF laàn nöõa ñeå taét maùy ñieàu hoøa.
• Khi maùy neùn döøng hoaït ñoäng, thieát bò ngaên khôûi ñoäng laïi seõ hoaït ñoäng vì theá maùy
Naép cöûa vaän haønh neùn seõ khoâng hoaït ñoäng trong 3 phuùt ñeå baûo veä maùy ñieàu hoøa.
( löïc xieát 13,7 ñeán Boä chænh löu
17,7 Nm, 140 ñeán ngaên löu löôïng
180 kgf•cm) phía sau Bôm chaân khoâng (hoaëc bôm 4-3. CHÖÙC NAÊNG TÖÏ KHÔÛI ÑOÄNG LAÏI
chaân khoâng coù chöùc naêng Loaïi maùy ñieàu hoøa naøy coù chöùc naêng töï khôûi ñoäng laïi. Khi nguoàn ñieän Bò ngaét khi
ngaên löu löôïng phía sau) ñang hoaït ñoäng, maùy seõ töï khôûi ñoäng laïi theo ñuùng cheá ñoä Ñaõ caøi ñaët tröôùc khi maát
nguoàn. (Tham khaûo phaàn höôùng daãn söû duïng ñeå bieát theâm chi tieát.)
Löu y
yù khi söû duïng van ñieàu khieåån Khi ggaén van ñieàu khieån vaøo cöûa vaään
haønh,, loõi van coù theå bòò bieán daïïng Caån thaän:
hoaëëc loûng neáu aùp löïïc quaù
q lôùn. Ñieàu • Sau khi chaïy thöû hoaëc kieåm tra nhaän tín hieäu cuûa remote ñieàu khieån töø xa, taét
naøy coù theå g
gaây ra hieään töôïïng roø ræ. maùy ñieàu hoøa baèng E.O.SW hoaëc remote ñieàu khieån töø xa tröôùc khi taét nguoàn
ñieän. Neáu khoâng, maùy ñieàu hoøa seõ töï khôûi ñoäng khi coù nguoàn ñieän trôû laïi.
Khi gaén van ñieàu khieån vaøo cöûa Daønh cho ngöôøi söû duïng
Cöûa vaän haønh vaän haønh, kieåm tra ñeå chaéc chaén • Sau khi laép maùy ñieàu hoøa, haõy giaûi thích cho ngöôøi söû duïng hieåu roõ chöùc naêng
A raèng loõi van ôû vò trí ñoùng, sau ñoù
Van ñieàu khieån töï khôûi ñoäng cuûa maùy.
xieát chaët boä phaän A. Khoâng xieát • Coù theå taét chöùc naêng töï khôûi ñoäng neáu thaáy khoâng caàn thieát. Tham khaûo ñaïi lyù
Môû
chaë t boä phaän A hay xoay thaân mua maùy ñeå bieát caùch taét chöùc naêng naøy. Tham khaûo phaàn höôùng daãn söû duïng
Ñoùng OÁng naïp
Thaân van khi loõi van ôû vò trí môû. ñeå bieát theâm chi tieát.
3) Vaän haønh bôm chaân khoâng. (Huùt chaân khoâng trong khoaûng 15 phuùt.)
4) Kieåm tra chaân khoâng baèng van oáng noái coù ñoàng hoà, sau ñoù ñoùng van oáng noái coù 4-4. HÖÔÙNG DAÃN CHO NGÖÔØI SÖÛ DUÏNG
ñoàng hoà vaø ngöøng chaïy bôm chaân khoâng. • Xem phaàn HÖÔÙNG DAÃN SÖÛ DUÏNG, vaø giaûi thích cho ngöôøi söû duïng caùch söû duïng
5) Ñeå nhö vaäy trong khoaûng 1 ñeán 2 phuùt. Ñaûm baûo duy trì van oáng noái coù ñoàng hoà maùy (laøm theá naøo ñeå söû duïng remote ñieàu khieån töø xa, laøm theá naøo ñeå thaùo taám loïc
ôû vò trí cuõ. Kieåm tra xem aùp keá coù chæ –0,101 MPa [aùp keá] ) –760 mmHg) khoâng khí, laøm theå naøo ñeå thaùo vaø laép remote ñieàu khieån töø xa vaøo giaù giöõ, laøm theá
6) Thaùo van oáng noái coù ñoàng hoà khoûi cöûa vaän haønh cuûa van chaën. naøo ñeå veä sinh vaø caùc ñeà phoøng trongg quaù trình söû duïïng maùy ñieàu hoøa…)
7) Sau khi noái oáng vaø huùt chaân khoâng oáng daãn moâi chaát laøm laïnh, môû heát taát caû van • Khuyeân ngöôøi söû duïng neân ñoïc kyõ HÖÔÙNG DAÃN SÖÛ DUÏNG.
chaën treân caû thaønh oáng khí vaø oáng chaát loûng. Vaän haønh maø khoâng môû hoaøn toaøn
caùc van seõ laøm chaäm quaù trình hoaït ñoäng vaø gaây hö hoûng.
8) Tham khaûo 1-3 vaø naïp moâi chaát laøm laïnh theo haøm löôïng ñaõ ñöôïc chæ ñònh khi caàn
thieát. Neân naïp töø töø. Neáu khoâng coù theå laøm thaønh phaàn cuûa moâi chaát laøm laïnh thay
ñoåi vaø aûnh höôûng ñeán hoaït ñoäng cuûa maùy.
9) Vaën chaët naép cöûa vaän haønh cuûa van ñeå traû veà traïng thaùi ban ñaàu.
10) Kieåm tra roø ræ
5-2. THAÙO BOÄ PHAÄN ÑIEÀU HOØA TRONG PHOØNG CAÛNH BAÙO
Thaùo phaàn döôùi cuûa boä phaän ñieàu hoøa trong phoøng ra Khi bôm moâi chaát laøm laïnh xuoáng, taét maùy neùn tröôùc khi thaùo. oáng daãn moâi chaát
khoûi taám treo maùy. Khi thaùo phaàn goùc, thaùo caû hai goùc laøm laïnh. Maùy neùn coù theå bò noå neáu khoâng khí…loït vaøo trong.
beân traùi vaø beân phaùi phía döôùi cuûa boä phaän ñieàu hoøa
trong phoøng, sau ñoù keùo noù höôùng xuoáng vaø ra tröôùc
nhö minh hoïa trong hình beân phaûi.