N A T IO N A L F O A M

DATA SHEET
#NDD340
DISCHARGE CLOSURE
MCS TYPE FOAM CHAMBERS
Description
The National Foam Discharge Closure is designed to pro- tween two 150# ANSI class flanges without any special
vide a positive seal between the foam chamber and the disc holder. The discharge closure shall consist of a scored
product storage tank. It is designed to install directly be- stainless steel disc covered by a Teflon film. Non-asbes-
tween the foam chamber discharge flange and the tank tos gaskets shall be permanently attached to both sides of
shell. It is primarilly used on tanks containing products the disc. A tab shall be provided with a namplate identifing
which can polymerize or solidify in the chamber nozzle the disc serial number, burst pressure and other relavent
and in situations where the product stored is not compat- information. The disc shall be designed to rupture with a
ible with the foam chamber construction materials. pressure differential of 1.5 to 2.0 PSI at 72°F. The disc
shall be reversible and shall rupture at the same pressure
Features from either direction. Back pressure shall not exceed a
12” to 17” water column.
· Easy installation, even on existing tanks.
· Prevents product from entering chamber. The foam chamber shall require the installation of a stud
· Ease of maintenance. flange which allows the deflector to remain on the inside
· Reversible, can not be installed incorrectly. of the tank when the foam chamber is unbolted during in-
stallation of the discharge closure.
Applications
· Storage tanks containing products such as styrene
Technical Data
which can polymerize. Setting:
· Storage tanks containing products which attack the
Rupture Pressure ............. 1.5 to 2.0 PSI (.1 to.13 bar)
foam chamber standard construction materials.
Max. Back Pressure ......... 12”-17” (305-431 mm) wa-
ter column
Technical Specification Materials of Construction:
The discharge closure shall be a flat composite disc with Disc ................................... Stainless Steel & Teflon
gaskets attached to both sides. It shall mount directly be- Gaskets ............................. Non-Asbestos

9 /3 2 " O . D .
(7 m m )
A p p ro x . I. D .
A A N O N -A S B E S T O S G A S K E T
.0 0 1 T E F L O N S E A L
S /S D IS C
.0 0 1 T E F L O N S E A L
N O N -A S B E S T O S G A S K E T

Note: See Ordering Information for O.D. and I.D. sizes.

MCS Chamber Discharge Closure

www.Kidde-Fire.com
D IS C H A R G E C L O S U R E
S T U D F L A N G E
G A S K E T

L E A D W A S H E R
M C S
T Y P E B
F O A M
C H A M B E R H E X N U T

D E F L E C T O R
(R E F E R T O M C S C H A M B E R
IN S T A L L A T IO N IN S T R U C T IO N S
F O R D E F L E C T O R M O U N T IN G
T A N K P R O C E D U R E S )
W A L L

Installation Illustration

Ordering Information
Chamber Discharge Closure Stud Flange
Type Size Part Number O.D. I.D. with Nut * Gasket *
MCS-9 ....................... 4” ............. 1232-5200-4 ............. 6-3/4” ..... 4” .......... 1253-1821-3 ......... 1268-5734-1
MCS-9SS .................. 4” ............. 1232-5200-4 ............. 6-3/4” ..... 4” .......... 1253-1821-4 ......... 1268-5734-1
MCS-17 ..................... 6” ............. 1232-5200-6 ............. 8-5/8” ..... 6” .......... 1253-2821-3 ......... 1268-5804-2
MCS-17SS ................ 6” ............. 1232-5200-6 ............. 8-5/8” ..... 6” .......... 1253-2821-5 ......... 1268-5804-2
MCS-33 ..................... 8” ............. 1232-5200-8 ........... 10-7/8” ..... 8” .......... 1253-3821-3 ......... 1268-5844-2
MCS-33SS ................ 8” ............. 1232-5200-8 ........... 10-7/8” ..... 8” .......... 1253-3821-4 ......... 1268-5844-2
MCS-55 .................... 10” ............ 1232-5201-0 ........... 13-1/4” .... 10” ......... 1253-4821-3 ......... 1268-5854-0

* Stud flange mounting nuts and gaskets are provided with bolted, split deflector chambers. The stud flange
and gasket must be ordered separately when used with solid deflector chambers.

This information is only a general guideline, and each installation may require modifications to meet the applications or requirements of that situation.
The company reserves the right to change any portion of this information without notice. Terms and conditions of sale apply and are available on request.

6/01 Printed in U.S.A. (NDD3400.P65)

NATIONAL FOAM, INC.


P.O. Box 695 • Exton, PA 19341-0695 • (610) 363-1400 • Fax: (610) 524-9073
www.nationalfoam.com