(12V100Ah)

RA 12-100H (392w/cell)
RA12-100H is high rate series with 10 years floating design
life, especially designed for high rate load discharge
applications . By using strong grid and specific paste plate to
insure high performance during big current discharge
requirement when electricity is off ., High Rate series offering
extra-durable stable performance under high rate discharge.
Specification
Cells Per Unit 6
Voltage Per Unit 12
o
Capacity 392 W@15min-rate to 1.67V per cell @25 C
Weight Approx. 32Kg
Max. Discharge Current 1000 A (5 sec)
Internal Resistance Approx. 4 mΩ
o o
Operating Temperature Range Discharge: -20 C ~60 C
Charge: 0 oC~50 oC
Storage: -20 oC~60 oC

Normal Operating Temperature Range 25 oC±5 oC


Float charging Voltage 13.6 to 13.8 VDC/unit Average at 25 oC
Recommended Maximum Charging 30 A
Current Limit
Equalization and Cycle Service 14.6 to 14.8 VDC/unit Average at 25 oC
Self Discharge RITAR batteries can be stored for more than 6 months
o
at 25 C. Self-discharge ratio less than 3% per month
o
at 25 C. Please charge batteries before using.
Terminal Terminal F5/F12
Constainer Material A.B.S. (UL94-HB), Flammability resistance of UL94-V2
can be available upon request.

Dimensions
Unit: mm Dimension: 328(L)×172(W)×222(H) Terminal F12

Terminal F5

o
Constant Current Discharge Characteristics : A(25 C)
F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
9.60V 698.6 5 2 1 .5 406.4 3 4 7 .4 298.9 220.6 177.7 128.3 6 9 .0 7 55.10
10.0V 651.1 4 8 7 .6 379.4 3 2 9 .1 282.7 211.1 167.4 123.5 6 6 .5 0 53.20
10.2V 630.8 4 7 3 .1 367.7 3 2 1 .2 275.8 207.1 162.9 121.4 6 5 .3 6 52.25
10.5V 598.0 4 4 8 .6 355.6 3 0 9 .2 262.3 199.9 160.5 119.5 6 5 .1 7 51.59
10.8V 565.1 4 2 3 .8 343.4 2 9 7 .0 248.7 192.5 157.9 117.5 6 4 .8 9 51.02
11.1V 532.3 3 9 9 .2 331.3 2 8 4 .9 235.3 185.4 155.5 115.6 6 4 .5 1 50.35

Constant Power Discharge Characteristics : W(25 oC)


F.V/Time 2MIN 4MIN 6MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
9.60V 7518 5612 4 373 3738 3 211 2373 19 42 1402 7 5 5 .3 604.2
10.0V 7007 5247 4 081 3541 3 042 2272 18 29 1350 7 2 6 .8 580.8
10.2V 6789 5091 3 957 3457 2 967 2228 17 80 1327 7 1 4 .2 570.0
10.5V 6434 4826 3 827 3326 2 821 2150 17 53 1306 7 1 1 .4 564.3
10.8V 6081 4560 3 696 3196 2 675 2072 17 26 1284 7 0 7 .4 558.6
11.1V 5726 4295 3 566 3067 2 530 1994 17 00 1262 7 0 4 .5 552.9

All mentioned values are average values.


RA12-100H 12V100Ah
Storage characteristic

10 100
Supplementary charge required
8 (Carry out supplementary charge
0℃
before use if 100% capacity is
6 80 requires)

Capacity (%)
10℃
Life Expectancy (years)

Supplementary charge required


4 60 before use.
This supplementary charge will help
to recover the capacity and should
20℃ be made as early as possible.
40 40℃ 30℃
2 Supplementary charge may often
fail to recover the capacity.
The battery should never be left
20 standing till this state is reached

0
Supplementary charge and storage
0 10 20 30 40 50 2 4 6 8 10 12 14 16 18 20 22 24 guidelines

Battery Temperature (℃) Storage Time (months)

15 7.5 5.0 120 0.24


Chcrge Volume 13 6.5 4.3

14 7.0 4.7 100 0.20


Chcrge Voltage
Term inal Voltage (V)
12 6.0 4.0
C harge Voltage ( V )

C harge Volum e (% )

C harge C urrent (C A)

13 6.5 4.3 80 0.16


① Discharge
100%(0.05CA×20h) 11 5.5 3.7
12 6.0 4.0 50%(0.05CA×10h) 60 0.12 0.05C
② Charge 0.16C 0.093C
Chcrge Voltage2.275V/C 0.35C
Charge Current0.1CA 10 5.0 3.3 0.62C
11 5.5 3.7 40 0.08
③ Temperature 25℃
3C 1C

10 5.0 3.3 20 0.04 9 4.5 3.0


Charge Current
0.6 1.2 3 6 12 30 1 2 5 10 20 24
9 4.5 3.0 0 0
0 2 4 6 8 10 12 14 16 18 20 24 28 min Hr

Charge Time(h) Discharge Time

Capacity Factors With Different Temperature


Battery Type -20℃ -10℃ 0℃ 5℃ 10℃ 20℃ 25℃ 30℃ 40℃ 45℃
GEL 6V&12V 50% 70% 83% 85% 90% 98% 100% 102% 104% 105%
Battery 2V 60% 75% 85% 88% 92% 99% 100% 103% 105% 106%
AGM 6V&12V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109%
Battery 2V 55% 70% 80% 85% 92% 99% 100% 104% 108% 110%

Discharge Current VS. Discharge Voltage Maintenance & Cautions

Final Discharge Float Service :


1.75V 1.70V 1.60V
Voltage V/cell
※  Every month, recommend inspection every battery voltage.
Discharge (A)≥1.0C
(A)≤0.2C 0.2C<(A)<1.0C
Current (A) ※  Every three months, recommend equalization charge for one time.

Equalization charge method:


Charge the batteries at least once every six months,
o
if they are stored at 25 C. Discharge: 100% rate capacity discharge.

Charging Method: Charge: Max. current 0.3CA, constant voltage 2.4-2.45V/Cell charge 24h.

Constant Voltage -0.2Cx2h +2.4~2.5V/Cellx24h,Max. Current 0.3CA ※  Effect of temperature on float charge voltage: -3mV/℃/Cell.

Constant Current -0.2Cx2h+0.1CAx12h ※  Length of service life will be directly affected by the number of discharge
.
Fast -0.2Cx2h+0.3CAx4.0h cycles, depth of discharge, ambient temperature and charging voltage.