Professional Documents
Culture Documents
Weiss Operating Theatre Canopies
Weiss Operating Theatre Canopies
Your Partner for Tomorrow's OT Air Your advantage: at Weiss, you get
Supply Systems everything from a single source.
Choose an ULA.4 or FFA.4 canopy unit,
For over four decades, the Weiss and combine it with one of our reliable
company has been setting research Weiss air conditioners.
and development standards in air-con-
ditioning systems for the most deman- Experienced engineers and plant
ding applications. In the seventies and specialists advise you from the start,
eighties, the Weiss supported air nozzle ensuring customized, well thought-out
canopy became a synonym for OT concepts and their implementation.
canopies. In the eighties, Weiss imple-
mented laminar flow solutions.
The latest concepts in room air supply,
In 2007, Weiss is setting standards in to the national and international stan-
the development of OT air-conditioning dards DIN 1946 T4, HTM 03-01 and
systems again, with the optimized SNIP
ULA.4 and FFA.4 canopies. Weiss OT
clean air systems are functioning safely Modern hospital hygiene focuses its
and reliably in more than 6,000 opera- interest in air-conditioning on a limited
ting theatres around the world. With protection zone, in which air-borne
their perfect design, in accordance with germs must be excluded rigorously
the latest scientific findings, these from operation wounds, and in which
systems are among the most modern patients may continue to pose concrete
and reliable installations anywhere. dangers (as sources of the spread of
infections to the surroundings). For
this OT area, it is required that the ent-
Deciding on Weiss – A Good Choice ire aseptic environment of surgery in
operating rooms, including the tables
If you make decisions about OT air- for materials and instruments, a free
conditioning equipment, whether as a zone for clean room hand-overs of ste-
hospital operator, the head of technical rilized materials and of the OT team in
services, the architect, or as a specialist steri-lized garb be shielded securely
planner, you should always consider a from the surroundings by a sufficiently
solution from Weiss Klimatechnik as large low-turbulence displacement air
one of the options. flow.
2
MEDICLEAN®
Weiss OT Clean Air Canopy. Photo courtesy of the pediatric cardiac center of the Justus Liebig
University hospital, Gießen, Germany
3
OT Clean Air Canopy ULA.4
Suspended ceiling
Weiss ULA.4
OT circulating air canopye
Suspended ceiling
Suspended ceiling
Surround lighting
4
MEDICLEAN®
> > > > > > > > > > >
>
>
>
>
>
>
>
>
>
>
>
Suspended ceiling
>
> Fresh air
System unit
Schematic diagram of the mode of operation of an ULA.4 clean air canopy in an OT . The pro-
tection zone (the entire aseptic surroundings of a surgical operation, including the materials
and instruments tables, a free zone for clean room hand-over of sterilized material and the OT
team in sterile garb) is shielded by a sufficiently large low-turbulence displacement air flow.
5
ULA.4 – Dimensions and Design
ULA.4 Length A Width B Clean air volume flow Circulating Clean air volume flow Circulating Weight Weight Qty
(m3/h) acc. to air portion (m3/h) acc. to air portion
Size (mm) (mm) DIN 1946 T41) (m3h) HTM 03-012) (m3h) (kg) 3) (kg) 4) partitions
1)
At outflow speed of 0.24 m/s
2
) At outflow speed of 0.38 m/s
3)
At height 550 mm, pressure chamber, height circulating air module 550 mm
4)
At height 550 mm, pressure chamber, height circulating air module 690 mm
Other unit sizes available on request. We reserve the right to make technical improvements.
6
MEDICLEAN®
Supply air
Clean air
Clean air
Height pressure chamber Height circulating No. of nozzles Width of nozzles Height of nozzles Luminaire
H (mm) air module H1(mm) C (mm) D (mm) penetration E (mm)
X/Y = 300 mm (for two-lamp Trilux luminaire) or 416 mm (for three-lamp Trilux luminaire)
7
OT Clean Air Canopy FFA.4
FFA.4 – The New Optimized Filter Area FFA.4 canopies feature full-surface
Canopies HEPA filters installed horizontally at the
ends, which are located directly ahead
The new FFA.4 is one of the optimized of the fabric diffusers (single layer or
OT clean air canopies. It is employed double layer or differential flow if
mainly where there is no room avail- required, polyester fabric). The hori-
able for air circulation modules, due zontal HEPA filter area and the fabric
to the size of the OT. provide a uniform diffusion of the air.
As in the ULA.4 circulating air canopy, The resistance of the HEPA filters in the
in the FFA.4 the clean, filtered air also filter area canopies is considerably less
flows from above into the OT, forming than that of end-mounted channel fil-
a protection zone (operating and ters, and averages 60 Pa at an outflow
instrument table and working area for speed of 0.24 m/s.
the surgical team in sterile clothing).
Weiss FFA.4
OT Filter Area Canopy
Surround lighting
Surround lighting
Suspended ceiling
8
MEDICLEAN®
> > > > > > > > > > > >
>
>
>
>
>
>
>
>
>
>
>
Suspended ceiling
>
> Fresh air
System unit
Schematic diagram of the mode of operation of an FFA.4 clean-air canopy in an OT . The protec-
tion zone (the entire aseptic surroundings of a surgical operation, including the materials and
instruments tables, a free zone for clean room hand-over of sterilized material and the surgical
team in sterile garb) is shielded by a sufficiently large low-turbulence displacement air flow.
9
FFA.4 – Dimensions and Design
FFA.4 Length A Width B Clean air volume flow Width of nozzles Width of nozzles Clean air volume flow Width of nozzles Weight (kg)
(m3/h) acc. to C 3) (mm) C3) (mm) (m3/h) acc. to C 3) (mm)
Size (mm) (mm) DIN 1946 T41) (450 mm) (300 mm) HTM 03-012) (450 mm) (450 mm)
1)
At 0.24 m/s outflow speed
2)
At 0.38 m/s outflow speed
3)
Without slatted flap; with slatted flap, nozzle width on request
Other unit sizes available on request. We reserve the right to make technical improvements.
10
MEDICLEAN®
Supply air
Supply
air
Clean air
Clean air
Clean air
300 80 578
450 200 578
11
Connection Details
Bare ceiling
Unconditioned
air side
1
Circulating
air module
2
Clean air side
3 3
Media column
Bare ceiling
Unconditioned
air side
2
Clean air side
3 3
OT OT protection zone
12
FFA.4 + Circulating Air Wall Module(s) MEDICLEAN®
13
Perfectly Matched Components
OT-clean air canopy with air-guide skirting of laminated safety glass. Hygienic recessed
luminaires (protection class IP 65), circulating air suction of painted perforated sheet metal.
14
MEDICLEAN®
15
Competent Immediate information We will be pleased to advise you about:
mediclean@wkt.com
www.wkt.com