Supplementary data of the Perfect Harmony Drive

Motor data provided by Customer

Motor type AC Induction


Motor voltage V 6300
Motor base frequency Hz 50
Motor shaft power kW 895
Motor efficiency % 96
Motor power factor cos phi % 85
Motor service factor 1
Motor current A 91.65

Line data provided by Customer

Number of phases   3 AC
Input voltage   6.9 kV
Input voltage tolerance   +10 %, -5 %1) of nominal rated input voltage
Input frequency Hz 50
Input frequency tolerance   +/-5 %
1) Input voltage falls below 90% to 65% of rated value
• output power is rolled-back linearly from 100% power @ 90% input voltage down to 50% power @ 65% input voltage
• output power is reduced by limiting the available motor torque
• continuous operation in this mode possible

General catalog data

Item type   Medium-voltage drive


Power semiconductors   IGBT’s, diodes
Topology Voltage source inverter: Cell-based topology,
multilevel cascaded H-bridge cells
Line-side rectifier   30 pulse diode rectifier
Motor-side inverter   Multilevel drive (PWM)
Drive control methods   Sensor-less closed-loop control, open-loop vector
control, V/Hz
Degree of protection   IP42
Standards IEC

The SINAMICS Perfect Harmony GH180 converter system is supplied with an integral isolation transformer which
allows to adapt to line side voltage as a standard solution from 475 V up to 8.00 kV for drives with 9 cells.
Drives with more than 9 cells can be supplied with line side voltage from 2.3 kV up to 13.8 kV.
Because of the unique multi-cell topology design, the SINAMICS Perfect Harmony GH180 converter does not
cause any significant stress on the motor insulation or bearings. The motor side Harmonic Voltage Factor is
below requirements of NEMA MG1-30 standard. Therefore, it is suitable for operation of both new and existing
standard direct-on-line motors.

CONFIDENCIAL 1 / 2
Supplementary data of the Perfect Harmony Drive
Electrical data

Short term overload   110% 1 min / 10 min


Output frequency and drift Hz 0.5 ... 330 ± 0.5 %
Output torque   Rated torques 2 quadrant
available from 10 – 167 Hz 2)
Voltage cut ride through duration   5 cycles
Permissible voltage dip (% of Un)   30%
Input power factor ≥ 0.95 above 10 % load, meets IEEE519:1992
Rated efficiency (Drive & Transformer) Typical 97 %, 96 % guaranteed across whole
power range
Torque pulsations across speed range   <1 % of rated without overmodulation
Cell type A140
Number of cells   15
Number of pulses of the transformer   30
Control voltage   380V
Control voltage tolerance   +/- 10%
Control voltage supply   Connection for control voltage 220/230 V AC by customer
I/O signal voltage   24VDC
Degree of pollution (operation)   2 without conductive pollution in acc. with IEC
61800-5
Biological ambient conditions in acc. with class 3B1 in acc. with IEC 60721-3-3
Chemical active substances in acc. with class   3C1 in acc. with IEC 60721-3-3
Mechanical active substances in acc. with class 3S3 (with optional NEMA 12/IP54 LV enclosures)
in acc. with IEC 60721-3-3

2) GH180 drives, when de-rated properly, are available for high frequency applications with de-rated torque.

CONFIDENCIAL 2 / 2