PROPOSED PLAN SHOWING MALL & MULTIPLEX IN

Office Use SY NO : 59 (59/P),WARD NO.8, BLOCK NO.7, SITUATED


AT KARMANGHAT VILLAGE, SAROOR NAGAR MANDAL,
OFFICE RANGAREDDY DISTRICT.
SEAL
BELONGS TO:
Y Y
SEC SEC 79.75 M 1.KATAM GANESH @ K.GANESH YADAV S/O.LATE KATAM JANGAIAH.
75.75 M FILE No. CSC TP- 200
2.KATAM MAHENDER @ K.MAHENDER YADAV KATAM S/O.KATAM GANESH
3.KATAM AMARENDER @ AMARENDER YADAV KATAM S/O.KATAM GANESH
2.0M WIDE BALCONY 2.0M WIDE BALCONY 4.KATAM RAJESH @ RAJESH YADAV KATAM S/O.KATAM GANESH
5.KATAM RAKESH @ RAKESH YADAV KATAM S/O.KATAM GANESH
6.KATAM RAM LAXMAN @ RAM LAXMAN YADAV KATAM S/O.KATAM GANESH
PERMIT No. DATE
LIFT LIFT LIFT LIFT
2.50X 2.50M 2.50X 2.50M 2.50X 2.50M 2.50X 2.50M DAGPA HOLDER
DN TO GROUND DN FROM 2ND DN TO 1ST DN FROM 3RD M/S. PRANAVA CONSTRUCTIONS.
FLOOR FLOOR FLOOR FLOOR
REPRESENTED BY ITS MANAGING PARTNER:
UP FROM UP TO 2ND UP FROM 1ST UP TO 3RD
GROUND FLOOR FLOOR FLOOR FLOOR SRI. BOORUGU RAVI KUMAR
S/O.B.MALLAIAH
ATRIUM
RETAIL AREA 9.95 X 9.97M RETAIL AREA
23.49 X 11.40M 23.49 X 13.40M
X X X X N
SEC SEC SEC SEC
18.77 X 6.55M 18.77 X 6.55M

2.0M WIDE BALCONY

2.0M WIDE BALCONY


SCALE 1:200
25.41 M

29.41 M
SPECIFICATIONS
LOBBY LOBBY LOBBY LOBBY

2.6M WIDE PASSAGE

2.6M WIDE PASSAGE


FOUNDATION C. C BED 1 : 4 : 8
LIFT 4.17X3.90M LIFT 4.17X3.90M LIFT 4.17X3.90M LIFT 4.17X3.90M
RETAIL AREA 2.50X2.45M
RETAIL AREA
2.50X2.45M RETAIL AREA 2.50X2.45M 2.50X2.45M
COLOUMNS R.C.C. 1:2:4
RETAIL AREA
22.43 X 25.37M 13.29 X 8.03M 24.43 X 29.37M
13.29 X 8.03M SUPER STRUCTURE BRICK IN C.M

DN DN
RETAIL AREA RETAIL AREA SLAB, BEAMS,CHAJJAS R.C.C 1:2:4
22.44 X 15.10M 24.44 X 29.37M
UP UP DN UP DN UP DOORS , WINDOWS TEAK WOOD

VENTILATOR C.T. WOOD

Conditions: FLOORING MARBLE FLOORING

5.49 X 5.94M 5.49 X 5.96M PLASTERING IN C.M


The permission accorded does not confer any ownership rights, At a later stage if it is found that the
1
documents are false and fabricated the permission will be revoked U/s 450 of HMC Act 1955. OPENINGS

2D

2D

2D

D2

2D

2D

2D

2D

2D

D2

2D

2D
If construction is not commenced within one year, building application shall be submitted afresh duly
2 paying required fees. DOORS: D- 2.00 x 2.10M,D1- 1.00 x 2.10M,D2-0.84X2.10M
2.0M WIDE BALCONY 2.0M WIDE BALCONY 3 Sanctioned Plan shall be followed strictly while making the construction.
30.39 X 2.00M G/D - 2.00 x 2.10M , F/D - 2.00 x 2.10M
4 Sanctioned Plan copy as attested by the GHMC shall be displayed at the construction site for public view.
Commencement Notice shall be submitted by the applicant before commencement of the building WINDOWS:W - 1.82 x 1.35M
5

FIRST FLOOR PLAN


Y Y U/s 440 of HMC Act.
SEC SEC

SECOND FLOOR PLAN


Completion Notice shall be submitted after completion of the building & obtain occupancy certificate VENTILATOR: V- 0.9 X 0.6m
6 U/s 455 of HMC Act.
7 Occupancy Certificate is compulsory before occupying any building. REFER SHEET NO. 1
Public Amenities such as Water Supply, Electricity Connections will be provided only on production of
8

(MORTGAGE PLAN)
occupancy certificate.
9 Prior Approval should be obtained separately for any modification in the construction.
10 Tree Plantation shall be done along the periphery and also in front of the premises.
11 Tot-lot shall be fenced and shall be maintained as greenery at owners cost before issue of occupancy
certificate.
12 Rain Water Harvesting Structure (percolation pit) shall be constructed.
13 Space for Transformer shall be provided in the site keeping the safety of the residents in view.
14 Garbage House shall be made within the premises.
Cellar and stilts approved for parking in the plan should be used exclusively for parking of vehicles
15 without partition walls & rolling shutters and the same should not be converted or misused for any other
purpose at any time in future as per undertaking submitted.
16 No. of units as sanctioned shall not be increased without prior approval of GHMC at any time in future.
17 This sanction is accorded on surrendering of Road affected portion of the site to GHMC free of cost with
out claiming any compensation at any time as per the undertaking submitted.
18 Strip of greenery on periphery of the site shall be maintained as per rules.
19 Stocking of Building Materials on footpath and road margin causing obstruction to free movement of
public & vehicles shall not be done, failing which permission is liable to be suspended.
Y Y
SEC 79.75 M SEC 79.75 M 20
The permission accorded does not bar the application or provisions of Urban Land Ceiling & Regulations
Act 1976.
The Developer / Builder / Owner to provide service road wherever required with specified standards at
2.0M WIDE BALCONY 2.0M WIDE BALCONY 21
24.69 X 2.0M 43.37 X 2.0M their own cost.
A safe distance of minimum 3.0mts. Vertical and Horizontal Distance between the Building &
22
A B C D E F G
8.12 [26'-7 1/2"]
G F E D C B A High Tension Electrical Lines and 1.5mts. for Low Tension electrical line shall be maintained.
LIFT LIFT LIFT LIFT
2.50X 2.50M 2.50X 2.50M REFUSE AREA BOX OFFICE 2.50X 2.50M 2.50X 2.50M
No front compound wall for the site abutting 18 mt. road width shall be allowed and only Iron grill or Low

EMERGENCY EXIT

EMERGENCY EXIT
DN TO 2ND DN FROM 4TH DN TO 3RD
FLOOR 11.52X7.40M 45° 23
FLOOR 45° FLOOR height greenery hedge shall be allowed.
UP FROM 2ND UP TO 4TH AUDI-01 WAITING AREA
UP FROM 3RD AUDI-05 24 If greenery is not maintained 10additional property tax shall be imposed as penalty every year till the
FLOOR FLOOR FLOOR condition is fulfilled.
8.12 X 11.19M

11.19 [36'-8 1/2"]


FRD
All Public and Semi Public buildings above 300Sq.mts. shall be constructed to provide facilities to

2.00 [6'-6 1/2"]

1.50 [4'-11"]
28.23 X 7.33M 25

+0.45M

+0.75M

+1.05M

+1.35M

+1.65M

+1.95M

+2.25M

+2.25M

+1.95M

+1.65M

+1.35M

+1.05M

+0.75M

+0.45M
FOOD COURT PRE SHOW LOBBY physically handicapped persons as per provisios of NBC of 2005.

+0.00M

+0.00M
DN DN
23.49 X 13.40M The mortgaged builtup area shall be allowed for registration only after Occupancy Certificate is
26
X XX WAITING AREA X produced.
SEC SEC
SEC 11.90 X 5.129M SEC 27 The Registration authority shall register only the permitted builtup area as per sanctioned plan.
18.77 X 6.55M
2.0M WIDE BALCONY

2.0M WIDE BALCONY


AUDI-03
The Financial Agencies and Institutions shall extend loan facilities only to the permitted builtup area as

2.00 M WIDE PASSAGE

2.00 M WIDE PASSAGE


13 13 13 13 13 13 13
ENTRY 13 13 13 13 13 13 13 28
per sanctioned plan.
29.41 M

29.41 M
FOOD COURT SCOPE-2.39
AUDI-01 AUDI-05 SCOPE-2.39 The Services like Sanitation, Plumbing, Fire Safety requirements, lifts, electrical installations etc., shall be
2M WIDE ENTRY F 2M WIDE ENTRY 29
10.30X4.30M ENTRY +1.95M ENTRY 10.30X4.30M executed under the supervision of Qualified Technical Personnel.
24.44 X 20.24M

2M WIDE ENTRY
GAMES ZONE LOBBY
14.13X 4.01M LOBBY LOBBY
E
+1.65M LOBBY 30
Architect / Structural Engineer if changed, the consent of the previous Architect / Structural Engineer is
PERMISSIBLE HEIGHT: 27.00 MTS
AUDI-02 required and to be intimated to the GHMC.
24.43 X 29.37M 4.17X3.90M 4.17X3.90M SCOPE-2.39 4.17X3.90M D
4.17X3.90M AUDI-04 SCOPE-2.39
2.00 M WIDE PASSAGE

2.00 M WIDE PASSAGE


LIFT LIFT 2M WIDE ENTRY LIFT LIFT 2M WIDE ENTRY
2.50X2.45M 2.50X2.45M 10.30X4.30M ENTRY 2.50X2.45M +1.35M 2.50X2.45M 10.30X4.30M 31 Construction shall be covered under the contractors all risk Insurance till the issue of PROPOSED HEIGHT: 26.95 MTS
ENTRY occupancy certificate (wherever applicable).
C NO. OF CARS 236 CARS
13 13 13 13 13 13 13
+1.05M 13 13 13 13 13 13 13

EMERGENCY EXIT

EMERGENCY EXIT
B 32 As per the undertaking executed in terms of G.O. Ms. No. 541 MA, dt. 17-11-2000 (wherever applicable),
+0.75M FOOD STALL-02 a) The construction shall be done by the owner, only in accordance with sanctioned Plan under the strict REFERENCE
LADIES LADIES A 4.00 X 4.67M
5.64X5.0M supervision of the Architect, Structural Engineer and site engineer failing which the violations are liable for
5.64X5.0M
DN UP DN UP DN UP +0.45M
DN UP
demolition besides legal action. PROPOSED

1.50 [4'-11"]
2.00 [6'-6 1/2"]

+0.75M

+1.05M

+1.35M

+1.65M

+1.95M

+2.25M

+2.25M

+1.95M

+1.65M

+1.35M

+1.05M

+0.75M
2.00 M WIDE PASSAGE

b) The Owner, Builder,Developer, Architect, Structural Engineer and Site Engineer are jointly & severely

+0.00M

+0.00M
+0.45M

+0.45M
D2

D2

D2

D2
D2

D2

D2

D2

DN DN
responsible to carry out and complete the constructionstrictly in accordance with sanctioned plan. EXISTING
FOOD STALL-1 FOOD STALL-2 FOOD STALL-3 FOOD STALL-4 DN DN
8.02X 11.98M 4.82X6.90M 4.83X6.90M 4.83X6.90M 4.82X6.90M c) The Owner, Builder,Developer, Architect, Structural Engineer and Site Engineer are jointly and severely are
AUDI-02 SCOPE-2.39 AUDI-03 AUDI-04 held responsible for the structural stability during the building construction and should strictly adhere to all the
GENTS
D D D D GENTS
13.30X5.21M
conditions in the G.O. Owner's Signature:
7.87X4.30 FOOD STALL-01
7.87X4.30 +0.00M d) The Owner / Builder,Developer, should not deliver the possession of any part of built up area of the building
45° 4.00 X 4.63M
45°

44°
by way of Sale / Lease unless and until Occupancy Certificate is obtained from GHMC after providing all the

D2

D2

D2

D2

D2
KITCHEN KITCHEN KITCHEN KITCHEN 1.61 [5'-3 1/2"]
D2

D2

D2

D2

D2

regular service connections to each portion of the building and duly submitting the following.
A B C D E F G G F E D C B A
D D D D (i) Building Completion Certificate issued by the Architect duly certifying that the building is completed as per the
sanctioned plan.
2.0M WIDE BALCONY 2.0M WIDE BALCONY 2.00 M WIDE PASSAGE 2.00 M WIDE PASSAGE 2.00 M WIDE PASSAGE (ii) Structural Stability Certificate issued by the Structural Engineer duly certifying that the building is
EMERGENCY EXIT 2.00 M WIDE PASSAGE
structurally safe and the construction is in accordance with the specified designs.
(iii) An extract of the site registers containing inspection reports of Site Engineer, Structural Engineer and
Y Y Architect.
SEC SEC
(iv) Insurance Policy for the completed building for a minimum period of three years.

THIRD FLOOR PLAN FOURTH FLOOR PLAN 33) Structural Safety and Fire Safety Requirements shall be the responsibility of the Owner, Builder/ Develope,
Architect and St. Engineer to provide all necessary Fire Fighting installations as stipulated in National Building
Code of India, 2005 like;
To provide one entry and one exit to the premises with a minimum width of 4.5mts. and height clearance of
5mts
ii) Provide Fire resistant swing door for the collapsible lifts in all floors.
iii) Provide Generator, as alternate source of electric supply.
iv) Emergency Lighting in the Corridor / Common passages and stair case.
v) Two numbers water type fire extinguishers for every 600 Sq.mts. of floor area with minimum of four numbes
fire extinguishers per floor and 5k DCP extinguishers minimum 2 Nos. each at Generator and Transformer
area shall be provided as per I.S.I. specification No.2190-1992.
vi) Manually operated and alarm system in the entire buildings;
Builder's Signature:
vii) Separate Underground static water storage tank capacity of 25, 000 lits. Capacity.
viii) Separate Terrace Tank of 25,000lits capacity for Residential buildings;
ix) Hose Reel, Down Corner.
x) Automatic Sprinkler system is to be provided if the basement area exceed 200Sq.mts.
xi) Electrical Wiring and installation shall be certified by the electrical engineers to ensure electrical fire safety.
xii) Transformers shall be protected with 4 hours rating fire resist constructions.
xiii) To create a joint open spaces with the neighbours building / premises for maneuverability of fire vehicles.No
parking or any constructions shall be made in setbacks area.

Y Y Office Use
SEC 79.75 M SEC 79.75 M i)

2.00 M WIDE PASSAGE 16.59 X 2.0M 24.69 X 2.0M

SL

E
L K O
A B C D E F G H I J
AUDI-01 J I H G F E D C B A

N
M PE

LI
LI

PE
EXIT +4.65M N
EMERGENCY EXIT

O
E

SL
L 45°
45°

K L AUDI-03 REFUSE AREA


AUDI-01 +4.20M 6.90 X 9.19M AUDI-05
EXIT OPEN TERRACE
OPEN TERRACE OPEN TERRACE
K
+0.75M

+1.05M

+1.35M

+1.65M

+1.95M

+2.25M

+2.55M

+3.00M

+3.45M

+4.20M

+4.65M

+4.65M

+4.20M

+3.45M

+3.00M

+2.55M

+2.25M

+1.95M

+1.65M

+1.35M

+1.05M

+0.75M
+0.45M

+0.45M
+0.00M

+0.00M

DN
LOBBY J
DN
Architect's Signature:
+3.45M
X 6.90 X 11.41M I X X X
(Regn.No.)
SEC +3.00M SEC SEC SEC
LOBBY
H 6.90 X 4.00M
2.00 M WIDE PASSAGE

+2.55M
13 13 13 13 13 13
AUDI-05 13 13 13 13 13 13
G
EXIT
29.41 M

29.41 M

+2.25M
SCOPE-2.39 2M WIDE ENTRY F 2M WIDE ENTRY SCOPE-2.39
10.30X4.30M +1.95M 10.30X4.30M
17 17 17 17 13 16 17 14 17 17 17 17
E
17 17 17 17 17 20 LOBBY +1.65M LOBBY 20 17 17 17 17 17 LOBBY LOBBY
2M WIDE ENTRY LIFT 4.17X3.90M D
+1.35M
LIFT 4.17X3.90M 2M WIDE ENTRY SCOPE-2.39 LIFT 4.17X3.90M LIFT 4.17X3.90M
2.50X2.45M 2.50X2.45M 10.30X4.30M 2.50X2.45M 2.50X2.45M
C

13 13 13 13 13 13
+1.05M 13 13 13 13 13 13
EMERGENCY EXIT

B
AUDI-02 +0.75M
DN A DN

UP UP OPEN TERRACE DN OPEN TERRACE DN OPEN TERRACE


+0.45M

+0.75M

+1.05M

+1.35M

+1.65M

+1.95M

+2.25M

+2.55M

+3.00M

+3.45M

+4.20M

+4.65M

+4.65M

+4.20M

+3.45M

+3.00M

+2.55M

+2.25M

+1.95M

+1.65M

+1.35M

+1.05M

+0.75M

+0.45M
+0.00M

+0.00M

+0.45M
DN DN
DN DN

SCOPE-2.39 AUDI-03
13.30X5.21M
AUDI-04
+0.00M
45°
45°

SL
E
N

O
LI

PE
PE

LI
O

A B C D E F G H I J K L L K J I H G F E D C B A

N
SL

E
2.00 M WIDE PASSAGE Structural Enginreer's Signature:
DN

DN

AUDI-02 2.00 M WIDE PASSAGE AUDI-04 2.00 M WIDE PASSAGE 2.00 M WIDE PASSAGE
EXIT EMERGENCY EXIT EXIT (Regn.No)

Y Y
SEC SEC

FIFTH FLOOR PLAN TERRACE FLOOR PLAN

SHEET NO : 2