List of major installations and accessories of STP & ETP is highlightedbelow: -
Table No. 1: STP (200 KL per Day)
Sl. Description of Plant & Machinery Qty. Capacity
Bar screen
1 2 0.5m x 0.5m
(Coarse-10mm & Fine - 5mm)
Sewage Transfer Pump Submersible, centrifugal
2 2 12.5 m3/hr at 12 m head
vertical.
3 Drain pit sump pump submersible. 2 2.0 m3/hr at 7-8 m head
4 Diffusers for EQT & SHT (Coarse Bubble). 01 lot -
Filter Feed pump
5 2 (1w + 1s) 15 m3/hr at 32 m head
(Horizontal, Centrifugal, Self-priming).
6 Tubular diffuser (Fine) in SAFF Reactor. 01 lot -
7 SAFF Media for SAFF Reactor. 01 lot -
8 Air Blower (Twin Lobe Rotatory). 2 170 CFM at 5psi
9 Tube Settler Media for PST & SST. 01 Lot 12.5m3/hr
Pressure Sand Filter made out of 6mm MS plate
15m3/hr (1150mm x 1800
10 perforated under drain plate, self-supporting legsand 1
mm)
filter media with valves.
Activated Carbon Filter made out of 6mm MS plate
15m3/hr (1100mm x 1800
11 perforated under drain plate, self-supporting legs and 1
mm)
filter media with valves.
Treated water pump 5 HP 3 phase foot mounted non-
12 clog Horizontal, self-priming, Centrifugal pump with 2 15m3/hr- at 32 m head
motor, base frame, coupling, motor hood etc.
Sludge Recirculation pump 1.0 HP 3 phase foot
mounted non-clog Horizontal, Self Priming,
13 2 2.5m3/hr-at 10 m head
Centrifugal pump with motor, base frame, coupling,
motor hood etc. (Non Clog- SP series).
Filter Press (17+2 nos. plates, plate size - 450 mm x
14 1 -
450 mm-PP).
15 Screw pump with Crompton motor- 2 HP. 1 2.5m3/hr-at 50 m head
Chlorine Dosing System (with 01 pump & 200 ltrs.
16 Lot 0-6 lph
PVC Tank).
17 Interconnecting piping and valve. 01 Lot -
Instrumentation (Pressure Gauge, Level controller,
18 01 Lot -
solenoid valves etc.).
Electrical Panel & 3 core wire Cabling with earthing
19 suitable for 415 V, 3 Phase, 4 wires, 50 Hz power 01 Lot -
distribution system.

Table No. 2: ETP (30 KL per Day)


Sl. Description of Plant & Machinery Qty. Capacity
Feed pump 2 HP 3Ph foot mounted non-clog
1 selfpriming pump with motor, base frame, 2 2.5 m3/hr
coupling, motor hood etc.
Pressure pump 1 HP 32ph 2990 RPM foot
50 LPM at total head 32
2 mounted non-clog self-priming pump with 2
m
motor, base frame coupling motor hood etc.

Operation & Maintenance of STP & ETP situated behind Administrative Building Page 1 of 2
Dr. Ram ManoharLohia Institute of Medical Sciences, Vibhuti Khand, Gomti Nagar, Lucknow

Flash Mixer 0.5 HP suitable for tank comprising


of SS shaft with turbine type propeller warm
reduction gear box TEFC electric motor speed of
agitator 100 RPM. Common MS base frame for
3 mounting agitator unit including GI protection 1 1.0m dia x 1.5m depth.
hood for the motor. Foundation bolts, nuts etc.
as required of MS Galvanized. Including 1.0 m
dia. and 1.5 m depth MS sheet of 6mm thick
fabricated tank with inlet and outlet.
Flocculator epoxy painted MS shaft with teak
wood paddles 1 HP TEFC motor with IP-55
protection suitable worm reduction gear box.
Speed of the flocculator approx. 6 RPM MS
4 base frame painted with epoxy for mounting 1 1.2 m dia. x 1.2 m height
gear box and motor. GI weather protection hood
for motor. All bolts, nuts and washers as
required are of MS galvanized. MS tank
fabricated out of 6mm thick.
Online chemical doser with pumps
a. Dosing tank-I
5 3 0-6 lph
b. Dosing tank-II
c. Dosing tank-III
Pressure sand filter made out of 6mm MS plate
600 mm dia. x 1500 mm
6 perforated under drain plate, self-supporting legs 1
height
and filter media with valves.
Activated carbon Filer made out of 6mm MS
7 plate perforated under drain plate, self- 1 700 mm x 1500 mm
supporting legs and filter media with valves.
LT Switch Board of 3ph with suitable capacity
incoming switch of 63 A, on and off push button
8 DOI contactors for starting the motor with 1 -
indicating lamps, instruments like voltmeter,
ammeter etc. including internal wiring.
9 Interconnecting piping and valves 1 lot -
10 Cables along with cable trays 1 lot -

Operation & Maintenance of STP & ETP situated behind Administrative Building Page 2 of 2