Schneider Hotel Solution 2019
Schneider Hotel Solution 2019
EcoStruxure™ Architecture
Apps, Other
Schneider Electric
Analytics & and Third-Party
Services
End-to-end Cybersecurity
Connected Services
Cloud and/or On Premise
Other
Schneider Electric
Edge EcoStruxure Energy Expert
EcoStruxure Fire Expert
and Third-Party
Control EcoStruxure Security Expert Integration
e.g: Lift,
EcoStruxure Building Operation SmartX Edge Servers Property Management,
Visitor Management
Connected Third-Party
Products SmartX SmartX SmartX
KNX
Valves &
DALI Actuators
Fire Actassi Altivar™: Variable Meters iON Compact Connected Smart UPS Connected Products
Controllers Advanced Displays Room Panels Flex Speed Drives (PM8000) Breakers Panels
Sensors Lighting Lighting Premset
EcoStruxure maximizes the value of data
Translating data into actionable intelligence to enable better business decisions
Connect everything Capture critical data Convert data into Drive action through
from shop floor to at every level, from meaningful real-time information
top floor sensor to cloud analytics and business logic
The Edge, Amsterdam PM’s Office, Malaysia Gwanghwamun D-Tower, New South Glasgow Hilton Worldwide
South Korea Hospitals’ Campus
Always On
100%
Uptime
PM8000/
ION9000 Sepam/Micom
SM6 (Protection relay)
(Meter)
PremSet
MV Gear MV Gear
PSE
eIFE / IFE
MLVS Gear MLVS Gear
Ecostruxure
iPCC Power
Okken/ PLC or Advisor
NSX PM5000/
Blokset NT / NW / MTZ 3rd Party ATS EBO
8000
U U Ecostruxure
Final distribution
IP Communications
ModBus
Smart Smart Smart
Backbone
Panel Panel Panel
NSX
Outside Data center Data center
Prisma / Blokset ieM3000
24/7 Power Quality Monitoring
Ideal Voltage
ION9000 PM8000
Sample rating: 1024 samples/cycle Sample rating: 526 samples/cycle
Accuracy: Class 0.1s Accuracy: Class 0.2s
“I want to prevent electrical fires in my facility and have a solution to detect abnormal temperature rises in my
conductors. “
IN THE PAST:
Installed in isolated room
Unconnected
NEW TECHNOLOGY:
Connected
24/7 thermal monitoring
“I want to prevent electrical fires in my facility and have a solution to detect abnormal temperature rises in my
conductors. “
“I want to ensure uptime during an electrical outage and have peace of mind that I can rely on my generator when it is
needed.”
Modbus
Modbus Gateway
EGX150
Multiple Billing Report
Report Details
“I want to have an health check for my electrical system to quickly identify system issues and opportunities for improvement to avoid
unexpected downtime.”
Benefits: Mitigate human error and save time by automating testing & reporting especially in big
system with many loads. Automated Electrical Network Diagnostics for
> Power factor > Voltage imbalance
> Excessive voltage harmonics > Transformer overcapacity
> Over and under voltage
Page 23
EcoStruxure™ Power Advisor: Sample Reports: Know the WHY and its impact
System Score:
Evidence
Provides overall
system score Snapshots:
weighted by % of Isolate specific
system affected evidence of the
issue to provide
context without
fishing through
data
Issue Summary:
At a glance status
of all issues Issue Impact:
checked, and Understand the
number of areas impact of leaving
impacted. issues unresolved.
1. Address
2. Simplify issues with
IP further! today’s
Fieldbus
Networks
•Obstacles
• How do of
wetoday’s Field Bus
accelerate networks
IP adoption?
MP-C/V MP-C/V
RSTP*
i
l
Building Applications
d
i
n EcoStruxure Energy Expert EcoStruxure Fire Expert EcoStruxure Security Expert
g
Building Management
SmartX MP-V
7 & 9 points Fan Coil Units
Heat Pump Units
SmartX MP-C
Engineering Efficiency Tools
15, 18 (2x) points
Roof Top Units
Air Handling Units
Offline
programming
SmartX MP-C
24 & 36 points
SmartX Living Space Sensors Standard
applications
Custom Types
Device Configuration
• Device discovery / filtering
• Device network settings
• Diagnostic / crash report
Modular Design
Integrated Sensors
Temperature
Relative Humidity
CO2
Motion Key Benefits
Customizable models to best fit application
Replacement ease for repair or upgrade
Service port access for commissioning tool
Over 24 combinations meet varying application needs; fewer SKUs simplify ordering.
SENSOR
CALIBRATION
CONFIGURATION
OUTPUT
CONFIGURATION TRENDING
(CFM)
Open to other systems and softwares
Smart
SmartConnector
ConnectorFramework
Framework Solution Examples 3rd Party Application
Voice Control
Enterprise Workstation
Server Webstation
Site IP
network
Power Supply,
AS-P, AS-B
and I/O
MP-C
MP-C
modules
Controller
Controller
SmartX
SmartX
MP-V
MP-V
BACnet / IP
MP-V
MP-V
Large Buildings
3. Scalable (3/3)
Optimum solution for small buildings as well as large/multi site buildings Easily
integrate
Enterprise
Central
up to 10
Enterprise Servers
Enterprise Workstation
Enterprise Enterprise Workstation Server Webstation
Server Server Webstation
Site IP
Site IP network
network
Power Supply,
Power Supply, AS-P,
AS-P, AS-B
AS-B and I/O
MP-C
MP-C
and I/O modules
MP-C
MP-C
modules
Controller
Controller
SmartX
SmartX
Controller
Controller
SmartX
SmartX
MP-V
MP-V
BACnet / IP
MP-V
MP-V
BACnet / IP
MP-V
MP-V
MP-V
MP-V
Multi Site Buildings
5. Secure
Best-in class cyber security
100
ISO:27034 certified cybersecurity experts top 5
hotel chain in world – audited
adopted Validated with leading third-party
agencies
and approved
Control method:
Central control & Monitor
Control by Schedule
Control by occupancy
Control by mobile app
Control by local switch
Tablet for
Room Control
(adaptiApps)
Standalone + Traditional Wiring
BYOD Devices
GRMS
ELV Wiring Devices
(APAC/ME Only)
Hotel Room Controller HRC Door Lock
(Server
GuestComfort (ME Only)
Side)
SE8000
Design
• Touch screen
• Built-in temperature
• Built-in humindity sensor
• Built-in motion sensor
• Various backlight colour (White, amber, blue, green, red and grey)
• Supply voltage – 24V Glass Touch Panel 2 Buttons Glass Touch Panel 12 Buttons
RJ45 connection
for fast and clean
termination
LEDtatus indicator
& Labelling for
switch function
Multiple options for outlook
RJ45 connection
for fast and clean
termination
RS485 -2
Master
Bell
Input terminal DND/MUR
(Analog + Digital)
Input terminal
(Analog)
ELV switches
• Courtesy switch
• Install 2 or more motion sensor units for a much accurate detection. HRC Unit
Input terminal
• Door contact sensor – Dry contact (Analog + Digital)
• Connect the motion sensor and door contact cable to the HRC input
terminal
Note:
PIR sensor sensitivity will depends on room temperature. The hottest the room temperature, the least sensitive of the PIR sensor
Confidential Property of Schneider Electric | Page 53 For bath room area, it is strongly recommend to use a dual tech sensor.
Presence control method
Occupancy based solution detection by motion sensor
and door contact / door lock
Occupied Status: door close and motion sensor detect motion in room
Unoccupied status: door open then close and motion sensor can not detect Guest after delay time
Hotel Solution
Apps, Analytics & Services