SMOOTHER

High-speed Roll-up Door


K:&*< K;&+

Highly Air-Tightened×Wind resistance×Eco = SMOOTHER

1
K;&- KL&+>
SMOOTHER SERIES

More environmentally and user friendly.


SMOOTHER satisfies customer needs.

B G = > Q

Seven Distinctive Features P.3

Specifications and Options P.6

Highly Air-Tightened Model for Indoor Use


K:&*:M New model P.9

Compact Model for Indoor Use


K:&*< P.9

Model for both Indoor and Outdoor Use


K;&+,K;&, P.11

Large-sized Model for both Indoor and Outdoor Use


K;&-New model P.13

Model for Refrigerating Room


K:&*K P.15

Explosion-Proof Model
KL&+> P.17

2
※The photo shows one of the examples of installation
Seven Distinctive Features

*
Highly
Air-Tightened
Achieved A-3 , the industry’s highest level of air tightness
Although the newly designed RA-1AT is a pipe model, it offers excellent air tightness equivalent Air leak volume at 10 Pa(㎥/h・㎡)
to A-3 class (the industry’s highest level) as defined in the Japanese Industrial Standards. RB-2 optional high
RA-1AT
An airtight gasket allows the RA-1AT to provide about 10 times of the air tightness of our air-tightened type
standard RA-1C model. It also provides high insect/dust-proof performance to keep the work Positive
environment clean. pressure 7.6 19.2
*A-3 class is:
Negative
A level of air tightness performance defined in JIS A 1516 to indicate how much air leaks from the
pressure 6 18.7
shutter frame or gap. The RA-1AT meets an air leak level of 8 m3/h・m2 or less at 10 Pa of pressure
difference.

●Line of class (Positive pressure) ●Line of class (Negative pressure)


100 100
e
ed typ
3
s A-
50 air-t ighten 50 of c
las


Line
l high
/ h・m2)

/ h・m2)
na ned type
30 optio 30
h air-tighte
RB-2 s A-
3 nal hig
clas RB-2 optio
Air flow rate〔m3(

Air flow rate〔m3(


of T
-1A
Line 4
AT s A-
RA-1 s A-
4 RA of c
las
10
of clas 10 Line
8 Line 8
5 5

3 3
2 2

1 1
10 30 50 100 −10 −30 −50 −100
→Pressure differential
(Pa) →Pressure differential
(Pa)

*The values indicated here are test results, not guaranteed values. *The RB-2 highly air-tightened type is optional. * As of November 2009.

Wind 29.3 m/s*of wind pressure resistance when fully closed.


resistance The industry’ s highest level of wind pressure
resistance enables smooth opening and closing.
*Converted value (to wind speed), calculated based on the RB-4 with an effective opening width of 6,050 mm.

SMOOTHER easily opens and closes without a steel shutter even in strong
winds thanks to bearings (rollers) on the pipe ends. Achieves the industry’
s ▲Bearings on the pipe
 end of the sheet 
(RB-4)
highest level of wind pressure resistance among ultra-large shutters.
●Wind pressure-resistant performance(Wind pressure at with the pipe ●Wind velocity resistant performance(When in operation: wind velocity
yields or comes off from the rail when stopping at the lowermost level) at which the sheet can descend)
2000
14
(Parenthesized values are those converted to wind speed (m/s))

(64)
13
12
1500
Wind velocity (m/s)
Wind pressure (Pa)

(55) 11
10
1000
9
(45)
8
7
500
(32) 6
5

0 4
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10
Effective opening width (m) Effective opening width (m)

*This performance data is not a guaranteed value in any way. Be careful because it varies depending on the wind direction, use environment, etc.

3
Sheet shutter complying
Explosion proof
with JNIOSH Explosion-
Proof Guidelines.
Available for up to Zone 2 *
(formerly class 2 area).

SMOOTHER“RS-2E”is applicable to chemical


or other plants and facilities where hazardous
substances are processed. This model adopts both
a pressure-resistant, explosion-proof construction
and an intrinsically safe construction, instead of a
structure simply offering a higher degree of safety.
The RS-2E never becomes a source of fire, thereby (RS-2E)
ensuring user safety.
* Zone 2 is:
An area where an explosive atmosphere is unlikely to
develop during the normal operation of plants or similar
facilities, or where such an atmosphere may develop only
for a short time even during abnormal operation (excerpt
from JNIOSH Explosion-Proof Guidelines for Plants’
Electric Equipment).
Electric equipment used in such a hazardous area must be
of an approved model type. ▲Pressure-resistant, explosion-proof type electrical motor

Large
The largest size in the industry for ultrawide
opening
opening.〈K;&-〉
The largest size in the industry, enabling up to 60 m2 of indoor/
outdoor opening (10 m in width and 6 m in height).
Allows large vehicles such as trucks or forklifts carrying large materials to pass
smoothly. Safety sensors (rail embedded type, two optical axes) are also equipped
as standard to ensure even higher safety. Users can easily adjust these sensors.

〈Conventional size〉 〈Smoothers RB-4〉

4
Backup Embedded backup power available. The only feature of its kind offered in the industry.
power Ensures operation during an emergency. (*Optional for the RA-1C)
The sheet opens and closes by using the embedded backup power in case of power failure due to an earthquake
or fire. If emergency evacuation is needed during a power failure, the backup power prevents such situations as
closed sheet blocking an evacuation route with someone left inside, as is the case with conventional products.

〔One of three types of operation can be selected in case of power failure.〕


1. Manual operation: Users manually operate the ascend/descend buttons on the
operation panel to open and close the sheet (up to two times).
2. Automatic operation: Detects the stop due to a power failure and automatically opens the sheet.
3. External signals: When certain external signals are received, the sheet fully opens.
Power outage
compensation Frequency of sheet operation 2 times (in 30 minutes during standby time)
Output voltage Nominal DC 72 V
Backup power Battery service
life Recommended replacement every three years
supply
Type of power
supply Nickel-cadmium battery
Charging time 48 hours (charging time required after discharging to below 50% of battery content capacity)

Equipped with a“Flap function”that allows the pipe to easily disengage when
Safety something comes into contact with the sheet,
thereby preventing possible rail and sheet damage.
●The RA series is equipped with the“Flap function”
(optional for the RB-2) as standard. This allows
the pipe to easily disengage, thereby preventing
possible rail and sheet damage, even if a forklift
Cross-sectional view
comes into contact with the sheet. Lower pipe

●The lower pipe of the sheet is enclosed in cushion


material to reduce shock impact. Lower sheet
*The figure shows the RA series. Cushion sheet

Minimizes airflow through speedy open/close operation and by


ECO adjusting the opening height to accommodate passing objects.
Single pushbutton

●High-speed open/close operation (sheet opening


speed: 1.2 m/s) increases work efficiency and Infrared sensor

minimizes the entry of insects and dust.


●For example, to allow the entry of people, press the
push button set to open the shutter to height ①.
Entering vehicles will be detected by the infrared
sensor set to open the shutter to height ②. This
setting minimizes air-conditioning loss, thereby
contributing to energy saving.

5
Specifications & Options
● Specifications
RA-1AT,RA-1C RB-2 RB-3 RB-4 RA-1R RS-2E
Effective
Effective opening

opening width W800∼3000 W1000∼4500 W4550∼6000 W6050∼10000 W900∼3000 W1000∼4000


regulation

(mm)

Effective
opening height H900∼3000 H1000∼5000 H2000∼6000 H900∼3000 H1000∼4000
(mm)

Stainless steel
Colored steel
Box Colored steel plate control panel portion
( with ABS plastic cover ) plate

Rail Colored steel


Colored steel plate Stainless steel
Components used

plate
Aluminum Aluminum Aluminum
Rotor pipe Aluminum alloyφ216
alloyφ150 alloyφ150 alloyφ216
Polyester yarn
Sheet Polyester yarn encapsulated vinyl sheet Antistatic sheet
encapsulated vinyl sheet
Middle φ50.8
φ19.1 φ38.1 φ19.1 φ38.1
pipe With rollers on both ends
Lower φ50.8
φ38.1 φ38.1
pipe With rollers on both ends
Explosion-proof motor with
DC motor Induction motor Induction motor DC motor
Drive reduction gears and brakes
(300 W) (output 750 W) (output 1.5Kw) (300 W)
(d2G4) 400 W
Operation method

1.2m/s(Ascent 1.2m/s(Ascent 0.8m/s(Ascent 0.6m/s 1.2m/s(Ascent


velocity of the sheet) ・(6m<W≦8m)
・ velocity of the sheet) (Ascent velocity 0.75m/s (Ascent
Sheet velocity of the sheet)
・ 0.5m/s(Descent 0.5m/s ( Descent of the sheet)・ velocity of the sheet)・ velocity of the sheet)・
speed 0.8m/s(Descent velocity of the velocity of the 0.5m/s(8m<W≦10m) ・0.4m/s 0.8m/s(Descent 0.6m/s(Descent
velocity of the sheet) sheet) sheet) (Descent velocity of the sheet) velocity of the sheet) velocity of the sheet)

Upper/ Upper/lower limit Upper/lower limit


lower limits Upper/lower limit
setting switches and Encoder control switches and
switches
method teaching control teaching control
Opening/
closing speed Slow start/slow stop control Slow start/slow stop control
control
Photoelectric tube sensor Photoelectric tube sensor Explosion-proof type
Sensor

Phototube Photoelectric tube Photoelectric tube sensors


(phototransmitting / photoreceiving (phototransmitting / phototube sensor
sensor sensors (reflection type) (reflection type /2 optical axes) type, 2 optical axes) photoreceiving type) (reflection type)
Single phase AC 100 V, Single phase AC
(50 Hz/60 Hz) 6A Three-phase AC
200 V
Power supply Three-phase AC 200 V ± 10%
(50 Hz/60 Hz)
6A
(50 Hz/60 Hz)
200 V ± 10%
Single phase AC 200 V, (50 Hz/60 Hz) 5A
(50 Hz/60 Hz) 3A below 700 W 8 A

Allowable 120 times/h, 120 times/h, 90 times/h,


60 times/h 120 times/h, 2 times/min
frequency 2 times/min 2 times/min 1.5 times/min
Ambient
5 to 40 degree ー10 to 40 degree ー5 to 30 degree 5 to 40 degree
temperature
Special control prevents There should be no
Environmental
There should be no freezing or condensation at 20% to 90%. condensation/freezing freezing or condensation
conditions
*Excluding sheet portion at 20% to 85%.
Product There shall be no toxic gas, There should be no toxic gas,
There should be no toxic gas, powder dust, and condensation.
warranty powder dust, and condensation. powder dust, and condensation.

● Table of effective opening


width and height by model 6000
Opening height (mm)

5000
RB-2
RB-4
4000
RS-2E
RB-3
3000

2000 RA-1R

1000
RA-1AT,RA-1C
0
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Opening width (mm)

6
● HACCP compatible option
In addition to an insect-proof orange
sheet that prevents insects from
coming inside, a high performance
airtight gasket (optional) enhances
protection against the entry of
insects and dust.
Moreover, mounting a trapezoid
cover on the main body or
control panel prevents dust from
accumulating, thereby affording
▲Example of use: ▲Example of use:
easy cleaning. Trapezoid cover for main Trapezoid cover for
Rails and a main body box made of body box control box
stainless steel are also available. ▲Example of use

● Interlocking functions
1. The front chamber opens. 2. The front chamber closes and the rear chamber opens. 3. Both the front and rear chambers close.
Two units of Smoothers make a front chamber,
which are coordinated via a microprocessor.
An interlocking operation in which one side
opens and the other side does not is possible.
As it prevents external air from entering, it can
enhance air-conditioning efficiency. An optional
printed board can be added for linked operation Open Close Close Open Close Close

with belt conveyors, AGVs or other equipment.

● Sheet
●Inspect-proof effect
〈Standard finish〉 〈Explosion-proof finish〉 〈Option〉
(RA-1 series、RB-2、RB-3) (RS-2E) Compound eye sensitivity curve and light transmission vector
●Antibacterial sheet (Transparent) ●Unburnable sheet
Compound eye
sensitivity curve
Light transmittance (%)

Transparent sheet

*In addition, we can supply


Transparent sheet Transparent sheet orange color.
(Flameproof finish : Fire Office (Antistatic/flameproof finish : Fire
Registration No. E- 13 -42766) Office Registration No. E- 13 -42766)
●Special mesh window material Insect-proof orange sheet

Wavelength (nm)
Mesh1003 Mesh1004 Cutting a wavelength zone of around 350 nm, to which
Insect-proof orange sheet Insect-proof orange sheet
(Flameproof finish : Fire Office (Antistatic/flameproof finish : Fire Office insects are most responsive, this prevents insects from
Registration No. E- 13 -42766) Registration No. E- 13 -42766) coming inside.

●Dimension suitable for mounting windows


● Sheet window
Window Full-span window
A window on the Maximum width Minimum width Height Width Height
sheet allows workers RA-1AT
to check forklift or RA-1C W+110 Maximum
pedestrian traffic on height set
RA-1R W-500
Window 500 400 for each
the opposite side to RB-2
W+140 span
avoid collisions. RB-3
*Two types of windows RB-4 W-800 ̶ ̶
(transparent or insect-
proof orange color) are RS-2E ̶ ̶ ̶ ̶ ̶
available. * Windows that can be mounted are 1 to 3 windows for a single span or a
full-span window. (The number of windows varies depending on the width
of a sheet.)
* Window mounting positions may be located on the first, second, third, and
fourth stages.
Full-span window * Mesh window does not comply with a full-span window.
* For RA-1AT and RA-1C, if the opening width is less than 900, the maximum
width of window is W-300.

8
The newly released RA-1AT offers the industry’s
highest level of air tightness, equivalent to JIS A-3 class.

New model
K:&*:M, K:&*<
:lfZee%bg]hhk&nl^fh]^eZoZbeZ[e^_hkZghi^gbg`h_)'1fhkpb]^k'LnbmZ[e^_hkebgd^]hi^kZmbhgpbma
[^em\hgo^rhkl%:@Olhkhma^k^jnbif^gm'Ma^g^perZoZbeZ[e^K:&*:Mikhob]^lma^bg]nlmkrlab`a^lm
e^o^eh_Zbkmb`amg^llmh^gaZg\^bgl^\m(]nlm&ikhh_i^k_hkfZg\^'

▲Example of use : Automotive-related plants

▲Example of use : Food processing plants

▲Example of use : Supermarket


■ High air tightness specifications ensure enhanced insect/   
  dust-proof performance.

■ A perfect compact type with interlock control.

■ Model RC-1C has two type for the power supply, one is for
AC100V being available at home power supply and the other is
for AC200V.
▲Control panel

■ The optional backup power source allows you to open and


close the sheet (up to two times) during power outages. The
unit contributes to securing safety in the work environment.
  (* Please use the unit with the breaker for the primary power source always turned on.)

9
Highly Air-Tightened Model for Indoor Use "RA-1AT" , Compact Model for Indoor Use "RA-1C".


CAD download http://www.uniflow.co.jp

● Range of possible opening / Effective opening width (mm) : minimum W 800 to maximum W 3000
Effective opening height (mm) : minimum H 900 to maximum H 3000
● Power /Single phase AC 100 V, (50 Hz/60 Hz) 6A / Single phase AC 200 V, (50 Hz/60 Hz) 3A
● Sheet speed / 1.2 m/s (when ascending), 0.8 m/s (when descending)

RA-1C Installation

Steel square pipe Maintenance space Maintenance space


250 250
100 x 100 x 2.3 t
(Prepared by customers)

328
Box cover

100 W (Effective opening width) 100


33 (W+200) 33
Maintenance space

Backup power source (optional)


Startup sensor Startup sensor
Upper/lower limits Motor side Startup sensor
(optional)
100 250.4 100

B (optional) (optional)
*Terminal block built-in 328

100 250.4
UNIFLOW

Box cover Primary


power supply Single point pushbutton
Rail bracket Sheet sagging (optional)
(Fixing plate for reinforcement prepared by customers)
H (effective opening height)

H (effective opening height)


警告

Rail かけ込まない


真下で立ち

A’
止まらない

CAUTION sticker TOUCHLESS SENSOR

自動
設定

切換
上昇

停止

手動 下 降

Operation panel 102 100


Intermediate pipe(φ19.1)
*For the operation panel mounting location,
Phototube reflector please consult with us on site. 80
1200

65 (Fixing plate for reinforcement prepared by customers)


130

Lower pipe(φ38.1) Phototube sensor


500
500

FL±0
Maintenance space B’ Maintenance space
150 150
100 W (Effective opening width)
100

Steel square pipe


100 x 100 x 2.3 t 328
(Prepared by customers)
26.25 26 49.75

Steel square pipe


250.4

100 x 100 x 2.3 t


50.4

Resin guide
102

(Prepared by customers)
328

100 W (Effective opening width) 100


100

33 (W+200) 33 Sheet sagging

26.25 49.75
26

* Where to install the control panel or optional equipment must be determined through consultation at each site.
* Treatment of the installation base must be determined through consultation at each site.
* Treatment for the RA-1AT differs from that for the RA-1C. Please ask us for details.

10
This is the best selling UNIFLOW model, which may be
commonly used for indoors and outdoors.

K;&+, K;&,
>Zlrl^mmbg`h_nii^kZg]ehp^kebfbmihlbmbhgl'Ma^hi^kZmbhgiZg^eZeehplma^ob^pbg`h_ln\a
bg_hkfZmbhgZlfZbgm^gZg\^bgm^koZelZg]^kkhkbg_hkfZmbhg'
Ab`aerZbk&mb`am^g^]mri^!himbhgZe"ikhob]^l^gaZg\^]bgl^\m(]nlm&ikhh_i^k_hkfZg\^'

▲Example of use : Logistics center

▲Example of use : Manufacturing plant

▲Example of use : Printing plant

■ Operation panel equipped with display window :


  Displays maintenance information and the type of error in case a fault
  occurs in order to support maintenance and management by the user.

■ Easier setting of sheet upper and lower limit positions : ▲Control panel
  Control by the encoder allows easy and accurate settings on the
  operation panel at hand.

■ New phototube sensor :


  The angle adjust mechanism makes it easier to fix problems brought
by deviation of the optical axis, in addition to the two optical axis by
the double photo tube sensors standardized in view from making
much of the safeness.

11
RB-2, RB-3 for both Indoor and Outdoor Use


CAD download http://www.uniflow.co.jp

● Range of possible opening / Effective opening width (mm) : minimum W 1000 to maximum W 4500(RB-2), minimum W 4550 to
maximum W 6000(RB-3) / Effective opening height (mm) : minimum H 1000 to maximum H 5000
● Power / Three phases AC 200 V 6A
● Sheet speed / RB-2 : 1.2 m/s when ascending, 0.5 m/s when descending / RB-3 : 0.8 m/s when ascending, 0.5 m/s when descending

RB-2,RB-3 Installation

Maintenance space Maintenance space


Steel square pipe
214 214
100 x 100 x 2.3 t
(Prepared by customers)

400
Box cover

114 W (Effective opening width) 114


Maintenance space

(W+230) 30
100 390.8 180

B Steel square pipe


100 x 100 x 2.3 t
(Prepared by customers)

100 390.8
Hanging fitting
Box cover
Motor
Rail Limit switch Startup sensor
bracket
Sheet sagging (optional)
Guide rail
Startup sensor H (effective opening height)
H (effective opening height)

(optional) Control panel


A 198 Control panel(three-phase 200 V)
A’ 110(three-phase 200 V)
Intermediate pipe(φ38.1) (Fixing plate for reinforcement prepared by customers) (Fixing plate for reinforcement
CAUTION
警告

Single point pushbutton(FL+1500)  prepared by customers)

484
484

Phototube
かけ込まない

sticker
真下で立ち
止まらない

(optional)
2-φ34 警 告
停止制御中
設定/調整
MONTOR
障害物検知
起動検知
運転可 情 報
INFORMATION

reflector
(Fixing plate for reinforcement prepared by customers)
65 (FL+1000) (For front side)
Entrance of power Phototube

1100
Primary sensor
Phototube reflector Lower pipe(φ38.1) Phototube sensor Detector
1100

power supply (for rear side)


130
130

rubber
500

500

(For front side) (For front side)


300

FL±0
Maintenance
Maintenance space Maintenance space
100 114 B’ W (Effective opening width) 114 100
space
650 126

St L-50x50x2.3t
(Rail fixing bracket Steel square pipe Upper base :
prepared by customers) 100 x 100 x 2.3 t 400 Welding or fixing by bolts
126 100

M8 Anchor bolt (Prepared by customers) 100 50


21 60 45

(Prepared by customers)
10.8

100 190.8 100


390.8

Resin guide
322

Steel square pipe


400

114 W (Effective opening width) 100 x 100 x 2.3 t


114
(Prepared by customers)
100

(W+230)
21 60 45
H (effective opening height)

20 30 St L-50x50x2.3t
126
(Fixing plate for reinforcement
 prepared by customers)
M8 Anchor bolt
(Fixing plate for reinforcement
FL±0  prepared by customers)

* Where to install the control panel or optional equipment must be determined through consultation at each site.
* Treatment of the installation base must be determined through consultation at each site.
* Treatment for High Air-Tightened model (option) differs from that for the standard model. Please ask us for details.
* The drawings above show the motor set in right side (standard type).

12
The largest size in the industry, enabling up to 60 m2 of
opening in plants or warehouses.

New model
K;&-
NemkZ&eZk`^mri^ZoZbeZ[e^_hklbs^lh_nimh*)fbgpb]maZg]/fbga^b`am'
LZ_^]^lb`g_^Zmnkbg`ma^bg]nlmkr'lab`a^lme^o^eh_pbg]k^lblmZg\^Zg]ghg^^]h_phkdbg`bgab`aieZ\^l]nkbg`Z]cnlmf^gm'

■ Largest size in the industry for ultra-wide opening :


  Affords an effective opening size up to 10 m in width and 6 m in height,
  thus allowing large vehicles like trucks to smoothly pass through. Improved
  durability particularly in the driving unit where a high load is applied.

■ Shutter featuring the highest wind resistance in the industry :


  Easily opens and closes even in strong winds thanks to bearings on the
  pipe ends of the sheet. Achieves the highest wind pressure resistance in
  the industry at 29.3 m/s* (when fully closed).
 *Converted value (to wind speed), calculated based on effective opening width of 6,050 mm.

■ Safe structure with new control panel _ No need of working in high places :
  The industry's first LCD touch panel allows for easy setting operation,
and also clearly indicates shutter operation status and the cause of
any error. Thanks to encoder control, all function settings including ▲Control panel

upper/lower-limit position can be made on the control panel, thereby


eliminating work in high places.

13
RB-4, large model for Indoor and Outdoor Use


CAD download http://www.uniflow.co.jp

● Range of possible opening / Effective opening width (mm) : minimum W 6050 to maximum W 10000
Effective opening height (mm) : minimum H 2000 to maximum H 6000
● Power / Three phases AC 200 V 6A
● Sheet speed / 0.6 m/s (6m< W≦8m), 0.5 m/s (8m< W≦10m) when ascending / 0.4 m/s when descending

RB-4 Installation

Maintenance space
300
Steel square pipe 700
150 x 100 x 3.2 t Maintenance space 305
(Prepared by customers)

238 117
150 W (Effective opening width) 150 Motor cover
Maintenance space

(W+300) (option)

Startup sensor Upper main body fitting


(optional) Upper main body fitting
PF tube 305 Safety measures 475 *No motor-cover
200 500 300

200 500 80
80

Startup sensor on the backside


Box cover (optional)

757

04-B-L35-2MFNR
Control panel
Sheet sagging Motor (three-phase 200 V)
Motor cover (Fixing plate for reinforcement
H (effective opening height)

(option) prepared by customers)

H (effective opening height)


Rail 332

CAUTION sticker Photoreceiving


595

警告 警告 sensors
Phototransmitting かけ込まない かけ込まない
196 100
sensor
真下で立ち 真下で立ち
止まらない 止まらない

Primary
1100

power supply
700

700
700
300

300

300
Maintenance space
300 700
Maintenance space
150 W (Effective opening width) 150

Steel square pipe 150 x 100 x 3.2 t


(Prepared by customers) 305 Steel square pipe
196 100

475 100 x 100 x 2.3 t


36.5 123 36.5

90

195
80

(Prepared by customers)
117

Steel square pipe


150 x 100 x 3.2 t
238

(Prepared by customers)
475

500

150 W (Effective opening width) 150


Steel square pipe
Box length (W+300) 100 x 100 x 2.3 t
(Prepared by customers)
H(effective opening height) 200

196 100
36.5 123 36.5

* Where to install the control panel or optional equipment must be determined through consultation at each site.
* Treatment of the installation base must be determined through consultation at each site.
* For outside use, install the products under a roof and mount the motor covers (optional).
* The drawings above show the motor set in right side (standard type).

14
This prevents the leakage of cold air and helps to save electricity.
Available for the front rooms containing refrigerators in food
processing plants.

K:&*K
This is the only cold storage model in the industry.
Ma^[nbem&bga^Zm^kik^o^gml\hg]^glZmbhg'
LmZbge^lllm^^eblnl^]mh^gaZg\^]nkZ[bebmrZg]ma^kfZebglneZmbhg'

■ The unit automatically detects the temperature difference


between outdoors and indoors, and controls heater
operation.

■ High-speed open/close operation reduces the leakage of


cold air.

■ Drum cover and guide rails are made of stainless steel for
higher rust resistance.

15
RA-1R for cold strage


CAD download http://www.uniflow.co.jp

● Range of possible opening / Effective opening width (mm) : minimum W 900 to maximum W 3000
Effective opening height (mm) : minimum H 900 to maximum H 3000
● Power / Single phase AC 200 V (50 Hz/60 Hz) below 700 W 8 A
● Sheet speed / 1.2 m/s when ascending / 0.8 m/s when descending

RA-1R Installation

Maintenance space Maintenance space


Steel square pipe 200 200
100 x 100 x 2.3 t
(Prepared by customers)

328
Box cover

100 W (Effective opening width) 100


33 (W+200) 33
Maintenance space

Startup sensor Startup sensor


Upper/lower limits (optional) Motor side (optional) Startup sensor
100 250.4 100

B 328 (optional)
*Terminal block built-in

100 250.4
Box cover UNIFLOW
Primary side
power supply Single point pushbutton
Rail bracket Sheet sagging (optional)
(Fixing plate for reinforcement prepared by customers)

H (effective opening height)


H (effective opening height)

警告 警告

Rail かけ込まない かけ込まない

A A’
真下で立ち 真下で立ち
止まらない 止まらない

CAUTION sticker 自動
TOUCHLESS SENSOR

設定

切換
手動
上昇

停止

下降

Operation panel 102


Phototube sensor Intermediate pipe(φ19.1) 100
*For the operation panel mounting location,
(Phototransmitting / please consult with us on site. 80
1200

Photoreceiving type) 65 (Fixing plate for reinforcement prepared by customers)


130

Lower pipe(φ38.1) Phototube sensor


500

500
(Phototransmitting / Photoreceiving type)
FL±0
Maintenance space B’ Maintenance space
100 100
100 W (Effective opening width) 100

Steel square pipe


100 x 100 x 2.3 t
328
(Prepared by customers)
26.25 26 49.75

100 50.4 100

Steel square pipe


Resin guide 100 x 100 x 2.3 t
250.4
102

(Prepared by customers)
100 W (Effective opening width) 100
328

H (effective opening height) 100

33 (W+200) 33 26.25 26 49.75