Professional Documents
Culture Documents
Katalog High Speed Roll-Up Door
Katalog High Speed Roll-Up Door
1
K;&- KL&+>
SMOOTHER SERIES
B G = > Q
Explosion-Proof Model
KL&+> P.17
2
※The photo shows one of the examples of installation
Seven Distinctive Features
*
Highly
Air-Tightened
Achieved A-3 , the industry’s highest level of air tightness
Although the newly designed RA-1AT is a pipe model, it offers excellent air tightness equivalent Air leak volume at 10 Pa(㎥/h・㎡)
to A-3 class (the industry’s highest level) as defined in the Japanese Industrial Standards. RB-2 optional high
RA-1AT
An airtight gasket allows the RA-1AT to provide about 10 times of the air tightness of our air-tightened type
standard RA-1C model. It also provides high insect/dust-proof performance to keep the work Positive
environment clean. pressure 7.6 19.2
*A-3 class is:
Negative
A level of air tightness performance defined in JIS A 1516 to indicate how much air leaks from the
pressure 6 18.7
shutter frame or gap. The RA-1AT meets an air leak level of 8 m3/h・m2 or less at 10 Pa of pressure
difference.
〕
Line
l high
/ h・m2)
/ h・m2)
na ned type
30 optio 30
h air-tighte
RB-2 s A-
3 nal hig
clas RB-2 optio
Air flow rate〔m3(
3 3
2 2
1 1
10 30 50 100 −10 −30 −50 −100
→Pressure differential
(Pa) →Pressure differential
(Pa)
*The values indicated here are test results, not guaranteed values. *The RB-2 highly air-tightened type is optional. * As of November 2009.
SMOOTHER easily opens and closes without a steel shutter even in strong
winds thanks to bearings (rollers) on the pipe ends. Achieves the industry’
s ▲Bearings on the pipe
end of the sheet
(RB-4)
highest level of wind pressure resistance among ultra-large shutters.
●Wind pressure-resistant performance(Wind pressure at with the pipe ●Wind velocity resistant performance(When in operation: wind velocity
yields or comes off from the rail when stopping at the lowermost level) at which the sheet can descend)
2000
14
(Parenthesized values are those converted to wind speed (m/s))
(64)
13
12
1500
Wind velocity (m/s)
Wind pressure (Pa)
(55) 11
10
1000
9
(45)
8
7
500
(32) 6
5
0 4
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10
Effective opening width (m) Effective opening width (m)
*This performance data is not a guaranteed value in any way. Be careful because it varies depending on the wind direction, use environment, etc.
3
Sheet shutter complying
Explosion proof
with JNIOSH Explosion-
Proof Guidelines.
Available for up to Zone 2 *
(formerly class 2 area).
Large
The largest size in the industry for ultrawide
opening
opening.〈K;&-〉
The largest size in the industry, enabling up to 60 m2 of indoor/
outdoor opening (10 m in width and 6 m in height).
Allows large vehicles such as trucks or forklifts carrying large materials to pass
smoothly. Safety sensors (rail embedded type, two optical axes) are also equipped
as standard to ensure even higher safety. Users can easily adjust these sensors.
4
Backup Embedded backup power available. The only feature of its kind offered in the industry.
power Ensures operation during an emergency. (*Optional for the RA-1C)
The sheet opens and closes by using the embedded backup power in case of power failure due to an earthquake
or fire. If emergency evacuation is needed during a power failure, the backup power prevents such situations as
closed sheet blocking an evacuation route with someone left inside, as is the case with conventional products.
Equipped with a“Flap function”that allows the pipe to easily disengage when
Safety something comes into contact with the sheet,
thereby preventing possible rail and sheet damage.
●The RA series is equipped with the“Flap function”
(optional for the RB-2) as standard. This allows
the pipe to easily disengage, thereby preventing
possible rail and sheet damage, even if a forklift
Cross-sectional view
comes into contact with the sheet. Lower pipe
5
Specifications & Options
● Specifications
RA-1AT,RA-1C RB-2 RB-3 RB-4 RA-1R RS-2E
Effective
Effective opening
(mm)
Effective
opening height H900∼3000 H1000∼5000 H2000∼6000 H900∼3000 H1000∼4000
(mm)
Stainless steel
Colored steel
Box Colored steel plate control panel portion
( with ABS plastic cover ) plate
plate
Aluminum Aluminum Aluminum
Rotor pipe Aluminum alloyφ216
alloyφ150 alloyφ150 alloyφ216
Polyester yarn
Sheet Polyester yarn encapsulated vinyl sheet Antistatic sheet
encapsulated vinyl sheet
Middle φ50.8
φ19.1 φ38.1 φ19.1 φ38.1
pipe With rollers on both ends
Lower φ50.8
φ38.1 φ38.1
pipe With rollers on both ends
Explosion-proof motor with
DC motor Induction motor Induction motor DC motor
Drive reduction gears and brakes
(300 W) (output 750 W) (output 1.5Kw) (300 W)
(d2G4) 400 W
Operation method
5000
RB-2
RB-4
4000
RS-2E
RB-3
3000
2000 RA-1R
1000
RA-1AT,RA-1C
0
1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
Opening width (mm)
6
● HACCP compatible option
In addition to an insect-proof orange
sheet that prevents insects from
coming inside, a high performance
airtight gasket (optional) enhances
protection against the entry of
insects and dust.
Moreover, mounting a trapezoid
cover on the main body or
control panel prevents dust from
accumulating, thereby affording
▲Example of use: ▲Example of use:
easy cleaning. Trapezoid cover for main Trapezoid cover for
Rails and a main body box made of body box control box
stainless steel are also available. ▲Example of use
● Interlocking functions
1. The front chamber opens. 2. The front chamber closes and the rear chamber opens. 3. Both the front and rear chambers close.
Two units of Smoothers make a front chamber,
which are coordinated via a microprocessor.
An interlocking operation in which one side
opens and the other side does not is possible.
As it prevents external air from entering, it can
enhance air-conditioning efficiency. An optional
printed board can be added for linked operation Open Close Close Open Close Close
● Sheet
●Inspect-proof effect
〈Standard finish〉 〈Explosion-proof finish〉 〈Option〉
(RA-1 series、RB-2、RB-3) (RS-2E) Compound eye sensitivity curve and light transmission vector
●Antibacterial sheet (Transparent) ●Unburnable sheet
Compound eye
sensitivity curve
Light transmittance (%)
Transparent sheet
Wavelength (nm)
Mesh1003 Mesh1004 Cutting a wavelength zone of around 350 nm, to which
Insect-proof orange sheet Insect-proof orange sheet
(Flameproof finish : Fire Office (Antistatic/flameproof finish : Fire Office insects are most responsive, this prevents insects from
Registration No. E- 13 -42766) Registration No. E- 13 -42766) coming inside.
8
The newly released RA-1AT offers the industry’s
highest level of air tightness, equivalent to JIS A-3 class.
New model
K:&*:M, K:&*<
:lfZee%bg]hhk&nl^fh]^eZoZbeZ[e^_hkZghi^gbg`h_)'1fhkpb]^k'LnbmZ[e^_hkebgd^]hi^kZmbhgpbma
[^em\hgo^rhkl%:@Olhkhma^k^jnbif^gm'Ma^g^perZoZbeZ[e^K:&*:Mikhob]^lma^bg]nlmkrlab`a^lm
e^o^eh_Zbkmb`amg^llmh^gaZg\^bgl^\m(]nlm&ikhh_i^k_hkfZg\^'
■ Model RC-1C has two type for the power supply, one is for
AC100V being available at home power supply and the other is
for AC200V.
▲Control panel
9
Highly Air-Tightened Model for Indoor Use "RA-1AT" , Compact Model for Indoor Use "RA-1C".
▼
CAD download http://www.uniflow.co.jp
● Range of possible opening / Effective opening width (mm) : minimum W 800 to maximum W 3000
Effective opening height (mm) : minimum H 900 to maximum H 3000
● Power /Single phase AC 100 V, (50 Hz/60 Hz) 6A / Single phase AC 200 V, (50 Hz/60 Hz) 3A
● Sheet speed / 1.2 m/s (when ascending), 0.8 m/s (when descending)
RA-1C Installation
328
Box cover
B (optional) (optional)
*Terminal block built-in 328
100 250.4
UNIFLOW
Rail かけ込まない
A
真下で立ち
A’
止まらない
自動
設定
切換
上昇
停止
手動 下 降
FL±0
Maintenance space B’ Maintenance space
150 150
100 W (Effective opening width)
100
Resin guide
102
(Prepared by customers)
328
26.25 49.75
26
* Where to install the control panel or optional equipment must be determined through consultation at each site.
* Treatment of the installation base must be determined through consultation at each site.
* Treatment for the RA-1AT differs from that for the RA-1C. Please ask us for details.
10
This is the best selling UNIFLOW model, which may be
commonly used for indoors and outdoors.
K;&+, K;&,
>Zlrl^mmbg`h_nii^kZg]ehp^kebfbmihlbmbhgl'Ma^hi^kZmbhgiZg^eZeehplma^ob^pbg`h_ln\a
bg_hkfZmbhgZlfZbgm^gZg\^bgm^koZelZg]^kkhkbg_hkfZmbhg'
Ab`aerZbk&mb`am^g^]mri^!himbhgZe"ikhob]^l^gaZg\^]bgl^\m(]nlm&ikhh_i^k_hkfZg\^'
■ Easier setting of sheet upper and lower limit positions : ▲Control panel
Control by the encoder allows easy and accurate settings on the
operation panel at hand.
11
RB-2, RB-3 for both Indoor and Outdoor Use
▼
CAD download http://www.uniflow.co.jp
● Range of possible opening / Effective opening width (mm) : minimum W 1000 to maximum W 4500(RB-2), minimum W 4550 to
maximum W 6000(RB-3) / Effective opening height (mm) : minimum H 1000 to maximum H 5000
● Power / Three phases AC 200 V 6A
● Sheet speed / RB-2 : 1.2 m/s when ascending, 0.5 m/s when descending / RB-3 : 0.8 m/s when ascending, 0.5 m/s when descending
RB-2,RB-3 Installation
400
Box cover
(W+230) 30
100 390.8 180
100 390.8
Hanging fitting
Box cover
Motor
Rail Limit switch Startup sensor
bracket
Sheet sagging (optional)
Guide rail
Startup sensor H (effective opening height)
H (effective opening height)
484
484
Phototube
かけ込まない
sticker
真下で立ち
止まらない
(optional)
2-φ34 警 告
停止制御中
設定/調整
MONTOR
障害物検知
起動検知
運転可 情 報
INFORMATION
reflector
(Fixing plate for reinforcement prepared by customers)
65 (FL+1000) (For front side)
Entrance of power Phototube
1100
Primary sensor
Phototube reflector Lower pipe(φ38.1) Phototube sensor Detector
1100
rubber
500
500
FL±0
Maintenance
Maintenance space Maintenance space
100 114 B’ W (Effective opening width) 114 100
space
650 126
St L-50x50x2.3t
(Rail fixing bracket Steel square pipe Upper base :
prepared by customers) 100 x 100 x 2.3 t 400 Welding or fixing by bolts
126 100
(Prepared by customers)
10.8
Resin guide
322
(W+230)
21 60 45
H (effective opening height)
20 30 St L-50x50x2.3t
126
(Fixing plate for reinforcement
prepared by customers)
M8 Anchor bolt
(Fixing plate for reinforcement
FL±0 prepared by customers)
* Where to install the control panel or optional equipment must be determined through consultation at each site.
* Treatment of the installation base must be determined through consultation at each site.
* Treatment for High Air-Tightened model (option) differs from that for the standard model. Please ask us for details.
* The drawings above show the motor set in right side (standard type).
12
The largest size in the industry, enabling up to 60 m2 of
opening in plants or warehouses.
New model
K;&-
NemkZ&eZk`^mri^ZoZbeZ[e^_hklbs^lh_nimh*)fbgpb]maZg]/fbga^b`am'
LZ_^]^lb`g_^Zmnkbg`ma^bg]nlmkr'lab`a^lme^o^eh_pbg]k^lblmZg\^Zg]ghg^^]h_phkdbg`bgab`aieZ\^l]nkbg`Z]cnlmf^gm'
■ Safe structure with new control panel _ No need of working in high places :
The industry's first LCD touch panel allows for easy setting operation,
and also clearly indicates shutter operation status and the cause of
any error. Thanks to encoder control, all function settings including ▲Control panel
13
RB-4, large model for Indoor and Outdoor Use
▼
CAD download http://www.uniflow.co.jp
● Range of possible opening / Effective opening width (mm) : minimum W 6050 to maximum W 10000
Effective opening height (mm) : minimum H 2000 to maximum H 6000
● Power / Three phases AC 200 V 6A
● Sheet speed / 0.6 m/s (6m< W≦8m), 0.5 m/s (8m< W≦10m) when ascending / 0.4 m/s when descending
RB-4 Installation
Maintenance space
300
Steel square pipe 700
150 x 100 x 3.2 t Maintenance space 305
(Prepared by customers)
238 117
150 W (Effective opening width) 150 Motor cover
Maintenance space
(W+300) (option)
200 500 80
80
757
04-B-L35-2MFNR
Control panel
Sheet sagging Motor (three-phase 200 V)
Motor cover (Fixing plate for reinforcement
H (effective opening height)
警告 警告 sensors
Phototransmitting かけ込まない かけ込まない
196 100
sensor
真下で立ち 真下で立ち
止まらない 止まらない
Primary
1100
power supply
700
700
700
300
300
300
Maintenance space
300 700
Maintenance space
150 W (Effective opening width) 150
90
195
80
(Prepared by customers)
117
(Prepared by customers)
475
500
196 100
36.5 123 36.5
* Where to install the control panel or optional equipment must be determined through consultation at each site.
* Treatment of the installation base must be determined through consultation at each site.
* For outside use, install the products under a roof and mount the motor covers (optional).
* The drawings above show the motor set in right side (standard type).
14
This prevents the leakage of cold air and helps to save electricity.
Available for the front rooms containing refrigerators in food
processing plants.
K:&*K
This is the only cold storage model in the industry.
Ma^[nbem&bga^Zm^kik^o^gml\hg]^glZmbhg'
LmZbge^lllm^^eblnl^]mh^gaZg\^]nkZ[bebmrZg]ma^kfZebglneZmbhg'
■ Drum cover and guide rails are made of stainless steel for
higher rust resistance.
15
RA-1R for cold strage
▼
CAD download http://www.uniflow.co.jp
● Range of possible opening / Effective opening width (mm) : minimum W 900 to maximum W 3000
Effective opening height (mm) : minimum H 900 to maximum H 3000
● Power / Single phase AC 200 V (50 Hz/60 Hz) below 700 W 8 A
● Sheet speed / 1.2 m/s when ascending / 0.8 m/s when descending
RA-1R Installation
328
Box cover
B 328 (optional)
*Terminal block built-in
100 250.4
Box cover UNIFLOW
Primary side
power supply Single point pushbutton
Rail bracket Sheet sagging (optional)
(Fixing plate for reinforcement prepared by customers)
警告 警告
A A’
真下で立ち 真下で立ち
止まらない 止まらない
CAUTION sticker 自動
TOUCHLESS SENSOR
設定
切換
手動
上昇
停止
下降
500
(Phototransmitting / Photoreceiving type)
FL±0
Maintenance space B’ Maintenance space
100 100
100 W (Effective opening width) 100
(Prepared by customers)
100 W (Effective opening width) 100
328