ESP Safety’s Vector model field control unit performs as an integrated control
terminal and display for ESP Safety’s gas detector product line. The Vector can
operate as a stand-alone display for a variety of our gas detectors which can be
remotely located up to 500 feet away. A sensor head can also be attached
directly to the display housing to produce a unified detector/display unit.
Key Features
• Vivid 2.7” (diagonal) 128x64 pixal resolution, OLED screen simutaneously
display a wide range of data including gas concentrations, alarm levels, faults
and operational modes
• Analog 4-20 current loop with HART, Digital RS- 485 Modbus RTU, and 4 relays
are standard data communication channels of the Vector
Voltage +24VDC Nominal (+18 to 32VDC) Material Aluminum and 316 Stainless Steel
Conduit Connection 2 Conduit Entrances 3/4” NPT
Power 4.3 W, standby <5.3 W,during alarm
Dimensions 10.7” x 5.9” x 4.8” **(Vector + PGU)
12.0Wwithheater on(temp≤30°C)
Weight 14 lbs (6.4 kg)
Outputs 1) Analog signal: 2x +4-20mA
Housing Warranty 5 years
2) Digital RS-485, Modbus RTU
3) HART communication port
4) Three User Programmed Alarm Relays,
Certifications
One Fault Relay
Technical Specifications
Humidity Class I, Division 1 Ex d IIC T4 Ex d IIC T4
0 to 100% relative humidity, non condensing -58°Fto +167°F -58°Fto +167°F
Groups B, C & D (-50°C to +75°C) (-50°C to +75°C)
Operating Temperature --58°F to +167°F (-50°C to +75°C) T4 Ta= -58°F to +167°F IP66 IP66
(-50°C to +75°C)
Storage temperature -76°F to +185°F (-60°C to+85°C) IP66
Class I, Division 1
Ingress Protection IP 66 Groups B, C & D
SIL 2 Rated T4 Ta= -58°F to +167°F
SIL Rating SIL 2 (-50°C to +75°C)
IP66
Methane CH4
Propane C3H8
Ethylene C2H8
Hexane C6H14
GAS DETECTOR
Plug-in universal Butane C4H10
gas sensors Isobutane I-C4P10
optic infrared ± 2% full scale
(0-100) % LEL
Ethanol C2H5OH
Cyclopentane C5H10
T20 <5 seconds
PGU-IR
Propylene C3H6 T90 <25 seconds
Methanol CH3OH
Gasoline Vapor *
Diesel Vapor *
JP4 Vapor *
(0-2) % vol. (0-5) % vol. T50 <3 seconds
± 2% full scale T90 <5 seconds
Carbon Dioxide C02 (0-3000) ppm
(0-20) ppm (0-200) ppm T20 <5 seconds
Isobutylene ± 2% full scale
C4H8 (0-2000) ppm T90 <25 seconds
(0-100) ppm (0-1000) ppm
Plug-in universal Benzene C6H6 (0-10000) ppm T50 <9 seconds
gas sensors ± 2% full scale T90 <25 seconds
photoionized Ethylene C2H4 (0-20) ppm (0-2000) ppm
(0-100) ppm
Methyl mercaptan CH3SH ± 2% full scale T90 <25 seconds
PGU-P Other ranges per request
All gases with ionization potential <10.6 eV
Hydrogen Sulfide (MOS) H2S (0-100) ppm ± 2% full scale T90 <20 seconds
Oxygen O2 (0-30) % vol. ± 2% full scale T90 <11 seconds
VECTOR
Carbon monoxide (0-100) ppm (0-500) ppm T20 <10 seconds
CO ± 2% full scale
(0-1000) ppm T90 <25 seconds
(0-20) ppm (0-50) ppm T20 <10 seconds
Hydrogen sulfide H2S ± 2% full scale
(0-100) ppm T50 <12 seconds T90 <25 seconds
PGU-E Chlorine C12 (0-20) ppm ± 2% full scale T90 <25 seconds