BWTS - HYUNDAI HWC-TSM-21 - GI-Power - Fuse Check Method

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Ballast Water Treatment System

HiBallast / Technical Information

Date 2021.03.18 Prepared by Checked by Approved by

Doc. No HWC-TSM-21
H.S.PARK J.W.YU S.H.LEE
Rev. 1.0

• Fuse check method

1. Cautions
(1) Turn off the Main Power prior to maintenance.

2. Maintenance method
Picture Explanation

1 Check fuse error LED on the pcb when rectifier Normal : LED ON LED STATE On/Off
power on Abnormal : LED OFF Module NO.1
(First, make sure that the CN650 connector is well Module NO.2
connected on the pcb) Module NO.3

Module 3 LED Module 2 LED Module 1 LED

<CN650 Connector >

< CN650 connector >

2 Check the 2-wire signal line of CN650


connector using a tester.

Normal : CLOSE
Abnormal : OPEN

Moudle 2 Connector state Open/Close


Module NO.1
Module NO.2
Moudle 3 Moudle 1 Module NO.3
3 Power off rectifier(rectifier off, circuit-breaker off) * Refer to module removal manual
pull-out the module
(Back side : remove bolts inside the hood)
(Front side : Power-line(3-wire), output-line(2-
wire) remove)
4

Micro switch check(FUSE signal check)

Check fuse switch switch Open/Close


Normal : CLOSE Switch 1
Abnormal : OPEN Switch 2
Switch 3

Fuse status check Fuse state Open/Close


Normal : CLOSE Fuse 1
Abnormal : OPEN Fuse 2
Fuse 3

This publication or any part there of may not be reproduced or transmitted by any process or means without
prior written permission of Machinery Division, Hyundai Welding Company.

You might also like