BALLAST WATER TREATMENT SYSTEM

HiBallast / Technical Information

Date 19.APR.2021 Prepared by Checked by Approved by


oc. No. HWC-DYK20-200415
D.Y.KIM I.G.KIM I.G.KIM
Rev. 0
Subject How to use Rectifier Disable function

1. Log in aconis2000
ID : aconis2000 / PW: aconis2000
Control Position : ROP (CCR)
Click MAIN Button to main page

This publication or any part there of may not be reproduced or transmitted by any process or E-MAIL: bwts-cs@hyundaiwelding.com
means without prior written permission of Machinery Division, Hyundai Welding Company.
BALLAST WATER TREATMENT SYSTEM

HiBallast / Technical Information

2. Click Disable button


(For example, suppose there is a problem with No.1 rectifier.)

Click

3. Go to TRO Control parameter page

This publication or any part there of may not be reproduced or transmitted by any process or E-MAIL: bwts-cs@hyundaiwelding.com
means without prior written permission of Machinery Division, Hyundai Welding Company.
BALLAST WATER TREATMENT SYSTEM

HiBallast / Technical Information

4. If Operator use disable function of No.1 Rectifier, Operator has to add the
amp value of the No.1 Rectifier to the rest of the rectifiers.

Disabled amp

In this page, No.1 Rectifier’s amp is 280A, Operator has to divide 280 into
No.2 and No.3 rectifiers and add them.

No.2 Retifier’s amp = 280 + 140 = 420

No.3 Retifier’s amp = 250 + 140 = 390

This publication or any part there of may not be reproduced or transmitted by any process or E-MAIL: bwts-cs@hyundaiwelding.com
means without prior written permission of Machinery Division, Hyundai Welding Company.
BALLAST WATER TREATMENT SYSTEM

HiBallast / Technical Information

5. Operator must input the calculated value.

1) Click SV Value
2) Change the value (280 > 420)
3) Enter (important)
4) Click Set button
5) Password : aconis2000
6) You need to check if the PV value has changed.
If it hasn't changed, please run the above procedure 1)~5)
again.(Important)

6. If the value has changed, it is possible to operate the BWTS normally even
if the first rectifier is disabled.

7. If the number 1 rectifier is fixed, please return the number 2 and number 3
rectifier values to their original state.

[END]