Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

ARCHITECT

Hord Coplan Macht, Inc.


700 E. Pratt St, Suite 1200

PINEHURST ELEMENTARY SCHOOL ROOF REPLACEMENT


Baltimore, MD 21202
p. 410. 837. 7311 f. 410. 837. 6530
ENVELOPE CONSULTANT
Construction Systems Group, Inc.
1451 Dolley Madison Blvd., Suite 300
McLean, VA 22101
p. 703.917.0055 f. 703.917.0464

520 S Pinehurst, Salisbury, MD 21801


1
IFB # 91066-192.
WICOMICO COUNTY PUBLIC
SCHOOLS

PINEHURST
DRAWING LIST ELEMENTARY
SCHOOL ROOF
Sheet
Number Sheet Name REPLACEMENT
CS.01 COVER SHEET
SYMBOL LEGEND 2

ROOF
SECTION MARKER
A1.01 ROOF PLAN
A1.02 ROOF DETAILS CUTS CONSTRUCTION 520 S Pinehurst, Salisbury, MD 21801
A1.03 ROOF DETAILS
.
A1.04 ROOF DETAILS 1 SECTION IDENTIFICATION
A1.05 ROOF DETAILS A1.1
SHEET WHERE SECTION APPEARS

DETAIL MARKER
DETAIL
.
1 DETAIL IDENTIFICATION
A1.1
SHEET WHERE DETAIL APPEARS

ALTERNATES ELEVATION MARKER


3

SHEET WHERE ELEVATION APPEARS


A4.2
1. Alternate Lump Sum Base Bid - Provide a price for the substitution of a torch-grade 2-ply modified bitumen ELEVATION IDENTIFICATION
1
roof system in lieu of application in hot asphalt.
INTERIOR ELEVATION MARKER
3
SHEET WHERE ELEVATION APPEARS
2. Provide an ADD/DEDUCT price for the substitution of foam insulation adhesive in lieu of hot asphalt (NOTE: At 2 A4.2 4
metal decks, base layer of rigid polyisocyanurate thermal insulation will remain mechanically attached). Amount ELEVATION IDENTIFICATION
1
will apply to both Base Bid and Alternate Base Bid
ROOM MARKER

3. Provide price for Base Bid roof replacement of Roof Section 8 and Roof Section 9 in compliance with the
APPLICABLE CODES ROOM ROOM NAME
100
summary of work and specifications. • 2015 INTERNATIONAL BUILDING CODE
MATERIAL FILL PATTERNS ROOM NUMBER

• 2015 INTERNATIONAL MECHANICAL CODE


4. Provide price for Alternate Base Bid roof replacement of Roof Section 8 and Roof Section 9 in compliance with • NATIONAL STANDARD PLUMBING CODE (MBPS) 2015 EDITION DOOR MARKER
ROUGH LUMBER OR BLOCKING 4
the summary of work and specifications • 2015 INTERNATIONAL ENERGY CONSERVATION CODE BRICK 101 DOOR NUMBER/OPENING
(CONTINUOUS) MARK
• 2015 INTERNATIONAL EXISTING BUILDING CODE

ROUGH LUMBER OR BLOCKING 1 WINDOW/STOREFRONT/LOUVER MARKER


CMU (DISCONTINUOUS)

PARTITION MARKER
CONCRETE WOOD FINISH A1 PARTITION TYPE

LEVEL
METAL PLYWOOD 0'-0" HEIGHT, ELEVATION MARKER

ROOF KEY PLAN


?

1986
EARTH BATT INSULATION GENERAL NOTE MARKER

MORTAR, GROUT, SAND RIGID INSULATION


REVISION MARKER 5

NO WORK THIS AREA 1963 YEAR BUILT

GYPSUM BOARD
1
AREA OF REVISION

REVISION IDENTIFICATION
ARCHITECTURE

1963
NO WORK THIS AREA
ROOF SECTION 1 ROOF TYPE, REFERENCE SPECIFICATIONS
0 BUILDING LINE
LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN
ABBREVIATIONS

A @ AT G GA GAUGE Q Q.T. QUARRY TILE


ACT ACOUSTICAL CEILING TILES GALV. GALVANIZED
ADJ ADJACENT GEN. GENERAL R R RISER
AFF ABOVE FINISHED FLOOR GL. GLASS R.A. RETURN AIR
ALUM ALUMINUM GWB GYPSUM WALL BOARD RAD. RADIUS
ROOF SECTION 8 ALT ALTERNATE GYP BD GYPSUM BOARD RCP REFLECTED CEILING PLAN
6
R.D. ROOF DRAIN
(BID ALTERNATE) H HM HOLLOW METAL REF REFERENCE, REFRIGERATOR

1963 B BARR.
BLDG
BLK/BLKG
BIT.
BM.
BARRIER
BUILDING
BLOCKING
BITUMINOUS
BEAM
HB
HC
HORIZ.
H.P.
HR
HOSE BIB
HANDICAPPED
HORIZONTAL
HIGH POINT
HOUR
REINF.
RM
R.O.
RQD.
REINFORCING
ROOM
ROUGH OPENING
REQUIRED

1969 ROOF SECTION 9


(BID ALTERNATE)
ROOF SECTION 7 (CANOPY)
C
BOT.
B.U.

C
BOTTOM
BUILT-UP

CHANNEL
I
HT

INSUL.
INT.
HEIGHT

INSULATION
INTERIOR
S SCHED.
SECT.
SHT
SIM
SCHEDULE
SECTION
SHEET
SIMILAR

1971 CAB CABINET S.P. STANDPIPE PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE

ROOF SECTION 1 CIP


CL
CAST-IN-PLACE
CENTERLINE
J J.C.
J.O.
JANITOR'S CLOSET
JAMB OPENING
SPECS
SQ.
SPECIFICATIONS
SQUARE
PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
CLG CEILING JT JOINT SS STAINLESS STEEL EXPIRATION DATE:
CMU CONCRETE MASONRY UNITS STL STEEL
ROOF SECTION 3 COL. COLUMN K KIT. KITCHEN ST./STOR/ STORAGE
CONC. CONCRETE STRUCT. STRUCTURAL
CONST. CONSTRUCTION L LAM. LAMINATE SUSP. SUSPENDED
C.J. CONTROL JOINT LAV. LAVATORY SW STORM WATER
CONT. CONTINUOUS L.F. LINEAR FEET
CORR. CORRIDOR L.P. LOW POINT T T TREAD 7
CPT CARPET TEL. TELEPHONE
CT CERAMIC TILE M M. MEN'S TOILET TH THRESHOLD
MACH. MACHINE THK. THICKNESS
D Ø, D DIAMETER MAINT. MAINTENANCE T.O. TOP OF
D. DEEP MAS. MASONRY T&B TOP AND BOTTOM
DET. DETAIL MANF. MANUFACTURER T&G TONGUE AND GROOVE
ROOF DIA.
DISP.
DIAMETER
DISPENSER
MAX
MECH.
MAXIMUM
MECHANICAL
TS
TYP
TRANSITION STRIP
TYPICAL

1961 NO WORK THIS AREA


1986
SECTION 4 DIM.
DN
D.S.
DTLS.
DWGS
DIMENSION
DOWN
DOWNSPOUT
DETAILS
DRAWINGS
M.H.
MIN
M.R.
M.O.
MISC.
MANHOLE
MINIMUM
MOISTURE RESISTANT
MASONRY OPENING
MISCELLANEOUS
U

V
U.L.
U.N.O.

VCT
UNDERWRITER'S LABORATORY
UNLESS NOTED OTHERWISE

VINYL COMPOSITION TILE


no.

Project Name
date

PINEHURST ELEMENTARY
revision

ROOF SECTION 2 ROOF SECTION 5 MTG MOUNTING V.B. VAPOR BARRIER SCHOOL ROOF REPLACEMENT

1961 1937 E EA
E.F.
ELEC.
ELEV.
EL.
EACH
EXHAUST FAN
ELECTRICAL
ELEVATOR
ELEVATION
N
MTL
MULL.

N.I.C.
NO.
METAL
MULLION

NOT IN CONTRACT
NUMBER
VERT.
VEST.
V.R.

W.
VERTICAL
VESTIBULE
VAPOR RETARDER

WOMEN'S TOILET
Project Number
218345.00
Date
W

ROOF SECTION 1 1968 EQ


EQUIP.
E.T.R.
EXIST.
EXP.
EQUAL
EQUIPMENT
EXISTING TO REMAIN
EXISTING
EXPOSED
O
NOM.
NTS

O.C.
O.D.
NOMINAL
NOT TO SCALE

ON CENTER
OUTSIDE DIAMETER
WD
W/
W/O
W.C.
W.P.
WOOD
WITH
WITHOUT
WATER CLOSET
WATERPROFFING
8
FEBRUARY 11, 2019
Scale
As indicated
ROOF SECTION 6 EXP. JT. EXPANSION JOINT. OPER. OPERATING WWF WELDED WIRE FABRIC Drawing
EXT. EXTERIOR OPG. OPENING WWM WELDED WIRE MESH
OPP. OPPOSITE COVER SHEET
F F.D. FLOOR DRAIN
FE FIRE EXTINGUISHER P PART. PARTITION
FEC FIRE EXTINGUISHER CABINET PASS. PASSAGE
FEC02 FIRE EXTINGUISHER CARBON DIOXIDE PERIM. PERIMETER

CS.01
FHC FIRE HOSE CABINET PL PLATE, PROPERTY LINE
FIN. FINISHED PLAS. PLASTER
FIXT. FIXTURE PLAM PLASTIC LAMINATE
FL. FLOOR POLY. POLYETHELYNE
ROOF SECTION 7 (CANOPY) FOS
FP
FACE OF STUD
FIREPROOFING
PREFAB
PREP.
PREFABRICATED
PREPARATION
FTG FOOTING P.T. PRESSURE TREATED
FURR. FURRING PTD PAINTED

CONSTRUCTION DOCUMENTS
9
2/11/2019 1:34:30 PM
A B C D E F G H J K L M C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt © Hord Coplan Macht, Inc.
ARCHITECT
NOTES: Hord Coplan Macht, Inc.
700 E. Pratt St, Suite 1200
Baltimore, MD 21202
1. STORE AND HANDLE ROOFING SHEETS IN A DRY, WELL-VENTILATED, WEATHER- p. 410. 837. 7311 f. 410. 837. 6530
TITE PLACE. STORE ROLLS OF FELT AND OTHER SHEET MATERIALS ON RAISED ENVELOPE CONSULTANT
SURFACE. STAND ALL ROLL MATERIALS ON END. COVER ROLL GOODS WITH A Construction Systems Group, Inc.
CANVAS TARPAULIN OR OTHER BREATHABLE MATERIAL (NOT POLYETHYLENE). 1451 Dolley Madison Blvd., Suite 300
McLean, VA 22101
p. 703.917.0055 f. 703.917.0464
2. DO NOT LEAVE UNUSED MATERIALS ON THE ROOF WHEN ROOFING WORK IS
NOT IN PROGRESS UNLESS PROTECTED FROM WEATHER AND OTHER MOISTURE
SOURCES.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE ALL MATERIAL AND


EQUIPMENT ON THE JOB SITE. IF ANY MATERIAL OR EQUIPMENT IS STORED ON
THE ROOF, THE CONTRACTOR MUST MAKE SURE THAT THE INTEGRITY OF THE 1
DECK IS NOT COMPROMISED AT ANY TIME.

4. DO NOT APPLY ROOFING INSULATION OR MEMBRANE TO DAMP DECK SURFACE. WICOMICO COUNTY PUBLIC
SCHOOLS
5. FULLY COMPLETE ALL MODIFIED BITUMINOUS MEMBRANE ROOFING FIELD
ASSEMBLY WORK EACH DAY. PHASED CONSTRUCTION WILL NOT BE ACCEPTED.

6. CONTRACTOR TO SUBMIT PULL OUT TEST DATA WITH FASTENING PATTERNS


FOR ALL ROOF AREAS. PINEHURST
CUSTOMER NOTES:
ELEMENTARY
1. ALL OF GARLAND'S SHOP FABRICATED MATERIAL WILL BE MANUFACTURED
TO THE DIMENSIONS SHOWN, UNLESS OTHERWISE NOTED. SCHOOL ROOF
2. IT IS ESSENTIAL THAT ANY NECESSARY CHANGES, NOTATIONS OR
2
REPLACEMENT
REQUESTED INFORMATION BE CLEARLY NOTED ON THE SHOP DRAWINGS.

3. NO MATERIAL WILL BE CONSIDERED RELEASED FOR FABRICATION UNTIL ALL


PERTINENT INFORMATION (i.e. COLOR, DIMENSIONS, MATERIAL CONFIG-
URATION) HAS BEEN RECEIVED.
520 S Pinehurst, Salisbury, MD 21801

LEGEND
ROOF SECTION 8 (BID ALTERNATE)

AREA NOT INCLUDED IN SCOPE OF PROJECT

RD ROOF DRAIN LOCATION 3

VTR VENT STACK LOCATION

EX. FAN EXHAUST FAN LOCATION

GV GOOSE NECK VENT LOCATION

RD
4
9H
A1.04
RD RD RD RD RD RD

ROOF SECTION 7 (CANOPY)


GV GV 6A 9A
VTR VTR
A1.03 A1.04
GV 9A
A1.03 EXPANSION JOINT
ROOF SECTION 3
RD RD
PIPE/ELEC. PENETRATIONS
VTR DS VTR DS DS
EX. FAN SPLIT SYSTEM UNITS (3) DS
VTR EX. FAN ROOF SECTION 9 (BID ALTERNATE)
GUTTER
HIGH ROOF
VTR GUTTER
ELEVATED PVC PIPE

GV 5G
GV EX. FAN DUCT PENETRATION (4) 5
A1.04 DS RD VTR RD
EXISTING ACCESS 5A
VTR
LADDER WITH CAGE A1.04 9E VTR VTR
9J RD RD A1.05
9J EX. FAN 9E ARCHITECTURE
A1.03 A1.03 GUTTER EX. FAN
GUTTER A1.05
VTR LANDSCAPE ARCHITECTURE
EX. FAN PIPE/ELEC. PENETRATIONS CANOPY BELOW VTR
PIPE PENETRATION VTR PLANNING
RTU RTU
VTR CANOPY BELOW INTERIOR DESIGN
DS
EX. FAN EX. FAN
VTR
9E EXISTING ACCESS
9D
A1.05 LADDER WITH CAGE
A1.04
RD RD
EX. FAN
GV
6E EX. FAN 6E
GV EXPANSION JOINT
A1.02 A1.02 6
@ CANOPY @ CANOPY

VTR
EXPANSION JOINT RD RD
EX. FAN
3G VTR
GV VTR VTR VTR
EX. FAN A1.05 EXISTING ACCESS
VTR LADDER WITH CAGE 9E
A1.05
RD RD
3A
A1.02
PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
GV 3J PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
6E
VTR
A1.03
6J
A1.03
A1.02
DS
ROOF SECTION 4 UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
EXPIRATION DATE:
TYP.
2D VTR
3A EXPANSION JOINT 9J
TYP. A1.04 SIM
3A
EX. FAN A1.05 A1.05
2J A1.03
EX. FAN 3J
A1.04 GV EX. FAN EX. FAN
A1.03 GUTTER 7
3E EXPANSION JOINT
RD RD VTR VTR
A1.03
SIM SIM
GV 6E
6E
A1.05
TYP. A1.05
2J EX. FAN
VTR
A1.04 VTR VTR
EX. FAN EX. FAN no. date revision
VTR 6E
3E A1.02 Project Name
TYP. GUTTER @ CANOPY
2F
RD A1.03 PINEHURST ELEMENTARY
RD SCHOOL ROOF REPLACEMENT
A1.04 ROOF SECTION 2
9J Project Number
A1.05 CANOPY BELOW 218345.00
GV GV
Date
FEBRUARY 11, 2019
8
Scale
ROOF SECTION 5 1/16" = 1'-0"
3J 6E
A1.03 A1.05 Drawing
GUTTER
ROOF PLAN
ROOF SECTION 1
ROOF SECTION 6
9A ROOF PLAN
A1.01 1/16" = 1'-0"

ROOF SECTION 7 (CANOPY)


A1.01
CONSTRUCTION DOCUMENTS
9
2/11/2019 1:34:29 PM
A B C D E F G H J K L M C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt © Hord Coplan Macht, Inc.
NOTE: ARCHITECT
SOLDER EXPANSION JOINT COVER SEAMS/ LAPS Hord Coplan Macht, Inc.
700 E. Pratt St, Suite 1200
26 GA. STAINLESS STEEL PITCH Baltimore, MD 21202
PREPARE AND PRIME PROJECTION LEAD WEDGE 18" O.C. p. 410. 837. 7311 f. 410. 837. 6530
PAN SOLDERED WATERTIGHT 4" MIN HEIGHT
ENVELOPE CONSULTANT
SEALANT, SEE SPECIFICATION SEAL TOP EDGE OF EXPANSION Construction Systems Group, Inc.
SEALANT, REFERENCE SPECIFICATION JOINT COVER TO MASONRY WITH 1451 Dolley Madison Blvd., Suite 300
26 GA. REGLET-MOUNTED STAINLESS COMPRESSIVE BEAD OF BUTYL
POURABLE SEALANT, STEEL COUNTERFLASHING McLean, VA 22101
SEALANT p. 703.917.0055 f. 703.917.0464
2 PART, 2" MIN. TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD MEMBRANE SHEET CLOSURE
SECURED AND ADHERED TO WALL
METAL CAP PER TORCH BASE FLASHING PLY 6" MIN. ON FIELD
SMACNA-ASMM 4TH 26 GA. STAINLESS STEEL JOINT
NON-SHRINK GROUT, 2" MIN.
EDITION PLATE 80 FIG. B COVER WITH T-TYPE CLEAT,
MODIFIED BITUMEN CAP SHEET SLOPED TO DRAIN
4" MIN. SEALANT, REFERENCE SPECIFICATION
MODIFIED BITUMEN BASE SHEET EPDM EXTENDED
FASTENERS APPROX. 8" O.C.
1
BACKER/VAPOR RETARDER
2x TREATED WOOD CURB

1/2" SECUROCK TERMINATION BAR FASTENED @ 8" O.C.


WICOMICO COUNTY PUBLIC

FLASHING HEIGHT
CANT STRIP THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
BASE FLASHING
SCHOOLS

8" MIN.
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
POLYISOCYANURATE INSULATION
0' - 4"
TORCH BASE FLASHING PLY 6" MIN. ON FIELD

BASE SHEET & VAPOR BARRIER


PINEHURST
EXISTING TECTUM DECK EXTEND FIELD PLIES ABOVE
ELEMENTARY
SEAL GAP AROUND
PENETRATION WITH FOAM
OPT: WOOD NAILERS; VARIES DEPENDING
MODIFIED BITUMEN CAP SHEET
TOP OF CANT STRIP
SCHOOL ROOF
2X TREATED WD BLOCKING AND TREATED
PLYWOOD AS REQUIRED. ANCHOR TO
DECK. DEPTH OF BLOCKING VARIES WITH
UPON SIZE OF PENETRATION
MODIFIED BITUMEN BASE SHEET
2
REPLACEMENT
LOCATION ON ROOF (TYP).

1/2" SECUROCK

POLYISOCYANURATE INSULATION 520 S Pinehurst, Salisbury, MD 21801

NOTE: WOOD CANT


MINIMUM 1" CLEARANCE FROM PENETRATION TO OUTER EDGE OF PITCH PAN.
PMMA LIQUID FLASHING IS ACCEPTABLE. 2x6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE.
OVERALL THICKNESS TO MATCH INSULATION. BASE SHEET & VAPOR BARRIER

3A ROOF AREA DIVIDER - BU/MOD BIT 3E PITCH POCKET DETAIL 3J ROOF EDGE DETAIL 1986 BUILDING @ 1937 BUILDING
A1.01 A1.02 1 1/2" = 1'-0" A1.02 1 1/2" = 1'-0" A1.01 A1.02 1 1/2" = 1'-0"

26 GA. STAINLESS STEEL STANDING


SEAM COPING COVER. PROVIDE GASKETED FASTENERS @ 24" O.C.
POSITIVE SLOPE.

TORCH MINERAL CAP FLASHING PLY 9"


MIN. ON FIELD. EXTEND PLIES UP & OVER
EXISTING THRU WALL FLASHING 22 GA. GALVANIZED STEEL CONTINUOUS WOOD NAILER.
CLEAT FASTENED @ 6" O.C.
TORCH BASE FLASHING PLY 6" MIN.
ON FIELD. EXTEND PLIES UP & OVER
LEAD WEDGE 18" O.C. WOOD NAILER

SEALANT, SEE SPECIFICATION CANT STRIP


MODIFIED BITUMEN CAP SHEET
26 GA. REGLETMOUNTED STAINLESS STEEL COUNTERFLASHING MODIFIED BITUMEN CAP SHEET
SEALANT, REFERENCE SPECIFICATION
MODIFIED BITUMEN BASE SHEET MODIFIED BITUMEN BASE SHEET
TERMINATION BAR FASTENED @ 8" O.C. 4
TORCH MINERAL CAP THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT) 1/2" SECUROCK
FLASHING PLY 9" MIN. ON FIELD
TORCH MINERAL CAP FLASHING
PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD

SEALANT, SEE SPECIFICATION TORCH BASE FLASHING


PLY 6" MIN. ON FIELD POLYISOCYANURATE INSULATION

26 GA. STAINLESS STEEL GRAVEL STOP SET IN


ROOF CEMENT, NAILED 3" O.C.. STAGGERED,
PRIME METAL FLANGE PRIOR TO STRIPPING

EXTEND PLY OVER BLOCKING FASTEN 8" O.C.


BASE SHEET & VAPOR BARRIER
22 GA. GALVANIZED STEEL
CONTINUOUS CLEAT FASTENED 6" O.C.
EXISTING TECTUM DECK

EXISTING WOOD BLOCKING SEAL GAPS AT ALL PERIMETERS WITH FOAM 5

EXISTING ROOF DECK


ARCHITECTURE
CANT STRIP
EXISTING BULB T WELDED TO STRUCTURE LANDSCAPE ARCHITECTURE
SEAL GAPS AT ALL
PERIMETERS WITH FOAM PLANNING

INTERIOR DESIGN

6E ROOF EDGE DETAIL 1971 BUILDING CANOPY 6J ROOF EDGE DETAIL TYPICAL COPING CAP DETAIL
A1.01 A1.02 1 1/2" = 1'-0" A1.02 1 1/2" = 1'-0"

NOTE: APPLY THIS ASSEMBLY TO ALL TECTUM ROOF DECK AREAS


NOTE: APPLY THIS ASSEMBLY TO ALL CANOPY DECK AREAS NOTE: APPLY THIS ASSEMBLY TO ALL STEEL ROOF DECK AREAS

GRANULAR-SURFACED MODIFIED
BITUMEN CAP SHEET IN HOT
ASPHALT ADHESIVE
GRANULAR-SURFACED MODIFIED
BITUMEN CAP SHEET IN HOT PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
ASPHALT ADHESIVE PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF MARYLAND
LICENSE NUMBER:
EXPIRATION DATE:
GRANULAR-SURFACED MODIFIED
BITUMEN CAP SHEET IN HOT
ASPHALT ADHESIVE
MODIFIED BITUMEN BASE SHEET
IN HOT ASPHALT ADHESIVE
MODIFIED BITUMEN BASE SHEET 7
IN HOT ASPHALT ADHESIVE

MODIFIED BITUMEN BASE SHEET


IN HOT ASPHALT ADHESIVE

no. date revision

Project Name
PINEHURST ELEMENTARY
SCHOOL ROOF REPLACEMENT
1/2" SECUROCK IN HOT 1/4:12 TAPERED Project Number
ASPHALT ADHESIVE POLYISOCYANURATE INSULATION 218345.00
1/2" SECUROCK IN HOT 1/4:12 TAPERED BOARD IN HOT ASPHALT ADHESIVE
MECHANICALLY FASTEN BASE SHEET ASPHALT ADHESIVE POLYISOCYANURATE INSULATION Date
ACCORDING TO WIND UPLIFT BOARD IN HOT ASPHALT ADHESIVE FEBRUARY 11, 2019
CALCULATIONS 8
MECHANICALLY FASTEN BASE SHEET
(1) LAYER OF 1.5" POLYISOCYANURATE Scale
ACCORDING TO WIND UPLIFT
CALCULATIONS INSULATION IN HOT ASPHALT ADHESIVE. 1 1/2" = 1'-0"
EXISTING TECTUM DECK (1) LAYER OF 1.5" POLYISOCYANURATE STAGGER ALL JOINTS.
INSULATION IN HOT ASPAHLT ADHESIVE Drawing
ACCORDING TO WIND UPLIFT ROOF DETAILS
EXISTING TECTUM DECK
CALCULATIONS. STAGGER ALL JOINTS.

EXISTING METAL DECK


MODIFIED BITUMEN VAPOR BARRIER IN
HOT ASPHALT ADHESIVE

A1.02
MECHANICALLY-ATTACHED 1/2"
SECUROCK ON STEEL DECK WITH
MODIFIED BITUMEN VAPOR BARRIER IN
HOT ASPHALT OVER 1/2" SECUROCK

9A TYPICAL ROOF CROSS SECTION - TECTUM DECK (CANOPY ROOFS) 9E TYPICAL ROOF CROSS SECTION - STEEL DECK 9J TYPICAL ROOF CROSS SECTION - INSULATED TECTUM DECK
A1.02 1 1/2" = 1'-0" A1.02 1 1/2" = 1'-0" A1.02 1 1/2" = 1'-0"
CONSTRUCTION DOCUMENTS
9
2/11/2019 1:34:29 PM
A B C D E F G H J K L M C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt © Hord Coplan Macht, Inc.
ARCHITECT
SEALANT, SEE SPECIFICATION
Hord Coplan Macht, Inc.
MODIFIED BITUMEN 700 E. Pratt St, Suite 1200
SEALANT, SEE SPECIFICATION
SEALANT, SEE SPECIFICATION MODIFIED MEMBRANE MINERAL CAP SHEET Baltimore, MD 21202
MODIFIED BITUMEN
MODIFIED BITUMEN 26 GA. STAINLESS STEEL GRAVEL STOP SET IN p. 410. 837. 7311 f. 410. 837. 6530
BASE PLY MODIFIED BITUMEN BASE SHEET MODIFIED MEMBRANE MINERAL CAP SHEET
MODIFIED MEMBRANE MINERAL CAP SHEET ROOF CEMENT, NAILED 3" O.C.. STAGGERED,
PRIME METAL FLANGE PRIOR TO STRIPPING 26 GA. STAINLESS STEEL GRAVEL STOP SET IN ENVELOPE CONSULTANT
26 GA. STAINLESS STEEL GRAVEL STOP SET IN TORCH MINERAL CAP ROOF CEMENT, NAILED 3" O.C.. STAGGERED, BASE PLY MODIFIED BITUMEN BASE SHEET
ROOF CEMENT, NAILED 3" O.C.. STAGGERED, BASE PLY MODIFIED BITUMEN BASE SHEET 1/2" SECUROCK Construction Systems Group, Inc.
FLASHING PLY 9" MIN. ON FIELD PRIME METAL FLANGE PRIOR TO STRIPPING
PRIME METAL FLANGE PRIOR TO STRIPPING TORCH MINERAL CAP 1/2" SECUROCK 1451 Dolley Madison Blvd., Suite 300
TORCH MINERAL CAP 1/2" SECUROCK BASE SHEET & VAPOR BARRIER FLASHING PLY 9" MIN. ON FIELD McLean, VA 22101
TORCH BASE FLASHING
FLASHING PLY 9" MIN. ON FIELD p. 703.917.0055 f. 703.917.0464
PLY 6" MIN. ON FIELD BASE SHEET & VAPOR BARRIER
BASE SHEET & VAPOR BARRIER POLYISOCYANURATE INSULATION TORCH BASE FLASHING
TORCH BASE FLASHING PLY 6" MIN. ON FIELD
PLY 6" MIN. ON FIELD POLYISOCYANURATE INSULATION
POLYISOCYANURATE INSULATION

22 GA. GALVANIZED STEEL


CONTINUOUS CLEAT FASTENED 6" O.C.
22 GA. GALVANIZED STEEL 1
22 GA. GALVANIZED STEEL CONTINUOUS CLEAT FASTENED 6" O.C.
CONTINUOUS CLEAT FASTENED 6" O.C.
EXTEND PLY OVER
BLOCKING FASTEN 8" O.C. WICOMICO COUNTY PUBLIC
EXTEND PLY OVER
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
SCHOOLS
BLOCKING FASTEN 8" O.C. NEW WOOD BLOCKING
NEW WOOD BLOCKING
NEW WOOD BLOCKING

EXISTING WOOD BLOCKING

EXISTING WOOD BLOCKING EXISTING 3/4" PLYWOOD


EXISTING WOOD BLOCKING
EXISTING
PINEHURST
TECTUM DECK
ELEMENTARY
EXISTING 3/4" PLYWOOD
WITH SPRAY COATING SCHOOL ROOF
2-1/2" STRUCTURAL INSULATING DECK
2
REPLACEMENT
WINDOW

WINDOW 2-1/2" STRUCTURAL INSULATING DECK

SEAL GAPS AT ALL PERIMETERS WITH FOAM


SEAL GAPS AT ALL PERIMETERS WITH FOAM 520 S Pinehurst, Salisbury, MD 21801
SEAL GAPS AT ALL PERIMETERS WITH FOAM

3A ROOF EDGE DETAIL 1961 BUILDING @ EAST PASSAGE 3E ROOF EDGE DETAIL 1961 BUILDING @ EAST 3J ROOF EDGE DETAIL 1961 BUILDING @ NORTH
A1.01 A1.03 1 1/2" = 1'-0" A1.01 A1.03 1 1/2" = 1'-0" A1.01 A1.03 1 1/2" = 1'-0"

SEALANT, SEE SPECIFICATION


MODIFIED BITUMEN
MODIFIED MEMBRANE MINERAL CAP SHEET
26 GA. STAINLESS STEEL GRAVEL STOP SET IN LEAD WEDGE 18" O.C.
ROOF CEMENT, NAILED 3" O.C.. STAGGERED, BASE PLY MODIFIED BITUMEN BASE SHEET
PRIME METAL FLANGE PRIOR TO STRIPPING SEALANT, SEE SPECIFICATION
TORCH MINERAL CAP 1/2" SECUROCK
FLASHING PLY 9" MIN. ON FIELD 2A 26 GA. STAINLESS STEEL COUNTERFLASHING
BASE SHEET & VAPOR BARRIER A1.04
TORCH BASE FLASHING SEALANT, REFERENCE SPECIFICATION
PLY 6" MIN. ON FIELD POLYISOCYANURATE INSULATION
POLYISOCYANURATE INSULATION TERMINATION BAR FASTENED @ 8" O.C.
MODIFIED BITUMEN CAP SHEET THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
EXPANSION TORCH MINERAL CAP FLASHING
JOINT MODIFIED BITUMEN BASE SHEET PLY 9" MIN. ON FIELD

22 GA. GALVANIZED STEEL 1/2" SECUROCK POLYISOCYANURATE INSULATION TORCH BASE FLASHING
CONTINUOUS CLEAT FASTENED 6" O.C. PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET 4

EXTEND PLY OVER MODIFIED BITUMEN BASE SHEET CANT STRIP


BLOCKING FASTEN 8" O.C.
1/2" SECUROCK 2-1/2" STRUCTURAL INSULATING DECK
NEW WOOD BLOCKING

EXISTING WOOD BLOCKING 0' - 2"

BASE SHEET &


EXISTING 3/4" PLYWOOD VAPOR BARRIER
WITH SPRAY COATING
METAL DECK
BASE SHEET & VAPOR BARRIER

BASE SHEET & VAPOR BARRIER EXISTING TECTUM DECK

5
WINDOW EXISTING 2-1/2" STRUCTURAL INSULATING DECK

1/2" SECUROCK
ARCHITECTURE

LANDSCAPE ARCHITECTURE

1961 BUILDING 1961 PASSAGE PLANNING

INTERIOR DESIGN

6A ROOF EDGE DETAIL 1986 BUILDING @ PASSAGE 6E ROOF EDGE DETAIL 1961 BUILDING @ PASSAGE 6J ROOF EDGE DETAIL 1961 BUILDING @ 1937 BUILDING
A1.01 A1.03 1 1/2" = 1'-0" A1.01 A1.03 1 1/2" = 1'-0" A1.01 A1.03 1 1/2" = 1'-0"

LEAD WEDGE 18" O.C.

SEALANT, SEE SPECIFICATION SEALANT, SEE SPECIFICATION


MODIFIED BITUMEN
26 GA. REGLET MOUNTED STAINLESS STEEL COUNTERFLASHING
MODIFIED MEMBRANE MINERAL CAP SHEET
SEALANT, REFERENCE SPECIFICATION 26 GA. STAINLESS STEEL GRAVEL STOP SET IN
ROOF CEMENT, NAILED 3" O.C.. STAGGERED, BASE PLY MODIFIED BITUMEN BASE SHEET
TERMINATION BAR FASTENED @ 8" O.C. PRIME METAL FLANGE PRIOR TO STRIPPING
THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT) TORCH MINERAL CAP 1/2" SECUROCK
FLASHING PLY 9" MIN. ON FIELD PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
TORCH MINERAL CAP FLASHING BASE SHEET & VAPOR BARRIER UNDER THE LAWS OF THE STATE OF MARYLAND
PLY 9" MIN. ON FIELD 2A TORCH BASE FLASHING LICENSE NUMBER:
A1.04 PLY 6" MIN. ON FIELD EXPIRATION DATE:
POLYISOCYANURATE INSULATION
TORCH BASE FLASHING POLYISOCYANURATE INSULATION POLYISOCYANURATE INSULATION
PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET MODIFIED BITUMEN CAP SHEET
EXPANSION
CANT STRIP MODIFIED BITUMEN BASE SHEET JOINT MODIFIED BITUMEN BASE SHEET
22 GA. GALVANIZED STEEL 7
1/2" SECUROCK CONTINUOUS CLEAT FASTENED 6" O.C.
1/2" SECUROCK

EXTEND PLY OVER


BLOCKING FASTEN 8" O.C.

NEW WOOD BLOCKING


no. date revision

EXISTING WOOD BLOCKING Project Name


PINEHURST ELEMENTARY
SCHOOL ROOF REPLACEMENT
Project Number
218345.00
EXISTING 3/4" PLYWOOD Date
BASE SHEET & VAPOR BARRIER FEBRUARY 11, 2019
8
BASE SHEET & VAPOR BARRIER Scale
EXISTING 2-1/2" STRUCTURAL INSULATING DECK 1 1/2" = 1'-0"
EXISTING METAL DECK

1/2" SECUROCK Drawing


SEAL GAPS AT ALL PERIMETERS WITH FOAM
EXISTING 2-1/2" STRUCTURAL INSULATING DECK ROOF DETAILS
EXISTING WINDOW

9J ROOF EDGE DETAIL 1968 BUILDING @ EAST


A1.03
A1.01 A1.03 1 1/2" = 1'-0"

9A ROOF EDGE DETAIL 1968 BUILDING @ SOUTH


A1.01 A1.03 1 1/2" = 1'-0" CONSTRUCTION DOCUMENTS
9
2/11/2019 1:34:30 PM
A B C D E F G H J K L M C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt © Hord Coplan Macht, Inc.
TORCH MINERAL CAP
NOTE: ROLL DOWN TOP PIECE LEAD SEALING MATERIAL MUST BE ARCHITECT
FLASHING PLY 9" MIN. ON FIELD
MANUFACTURER'S REINFORCED PMMA FLASHING 1" MIN. DOWN INTO PIPE CONTINUOUS ON THE PERIMETER Hord Coplan Macht, Inc.
FLEXIBLE WATERPROOF FLUID APPLIED FLASHING IS ACCEPTABLE TORCH BASE FLASHING PLY METAL COUNTERFLASHING FASTENED 8" O.C.
700 E. Pratt St, Suite 1200
MEMBRANE CLOSURE 6" MIN. ON FIELD SCREW OR RIVET TO FLASHING RECEIVER ONLY
PLUMBING VENT STACK C Baltimore, MD 21202
26 GA. STAINLESS STEEL L
p. 410. 837. 7311 f. 410. 837. 6530
EXPANSION JOINT COVER 4 LB. LEAD FLASHING (30" MIN.) SEALANT, REFERENCE SPECIFICATION
COVER SECURED 12" SET IN MASTIC, WRAPPED DOWN ENVELOPE CONSULTANT
O.C. W/ FASTENERS & FLASHING FASTENED 8" O.C. SEALANT, REFERENCE SPECIFICATION
2" MIN., PRIME BOTH SIDES TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD Construction Systems Group, Inc.
NEOPRENE WASHERS FLASHING RECEIVER
EXP JT WIDTH 26 GA. STAINLESS STEEL TORCH MINERAL CAP FLASHING 1451 Dolley Madison Blvd., Suite 300
CLEAT FASTENED 12" O.C. PLY 9" MIN. ON FIELD MODIFIED BITUMEN CAP SHEET McLean, VA 22101
TORCH BASE FLASHING PLY 6" MIN. ON FIELD p. 703.917.0055 f. 703.917.0464
TORCH MINERAL TORCH BASE FLASHING MODIFIED BITUMEN BASE SHEET ROOF DRAIN TERMINATION BAR FASTENED @
CAP FLASHING PLY PLY 6" MIN. ON FIELD 8" O.C. THROUGH BUTYL TAPE
MODIFIED BITUMEN MODIFIED BITUMEN CAP SHEET
9" MIN. ON FIELD CAP SHEET
1/2" SECUROCK

1' - 0"

MIN.
TORCH BASE FLASHING MODIFIED BITUMEN BASE SHEET

8" MIN.
MODIFIED BITUMEN MODIFIED BITUMEN

2" MIN.
PLY 6" MIN. ON FIELD BASE SHEET

8" MIN.
4" MIN BASE SHEET
1/2" SECUROCK
WOOD CANT 1/2" SECUROCK
1/2" SECUROCK MODIFIED BITUMEN
CAP SHEET ALL PLIES EXTEND UNDER 1
POLYISOCYANURATE TAPERED 8'X8' SUMP,MINIMUM CLAMPING RING
INSULATION THICKNESS IS 2"
WICOMICO COUNTY PUBLIC
BASE SHEET &
VAPOR BARRIER
SCHOOLS

POLYISOCYANURATE INSULATION CANT STRIP,


POLYISOCYANURATE FASTENED TO NAILER POLYISOCYANURATE
COMPRESSIBLE INSULATION EXP./ CONT. SET SOFT METAL FLANGE INSULATION BASE SHEET & VAPOR BARRIER INSULATION
IN MASTIC, PRIME FLANGE
FLEXIBLE VAPOR RETARDER TO
SERVE AS INSULATION RETAINER
EXP./ CONT. +1/2"
EXP./ CONT.
BEFORE STRIPPING BASE SHEET &
VAPOR BARRIER EXISTING TECTUM DECK
INSULATED LEADER UNIT MOUNTING CURB
BASE SHEET & PINEHURST
VAPOR BARRIER
ATTACH TO TOP OF CURB

EXISTING TECTUM DECK


SEAL GAP AROUND
PIPES WITH FOAM
EXISTING TECTUM DECK
EXISTING TECTUM DECK
ELEMENTARY
2A ROOF EXP JT DETAIL - BU/MOD BIT
1/2"
2D PLUMB VENT PENETRATION - BU/MOD BIT 2J EQUIP CURB - BU/MOD BIT SCHOOL ROOF
A1.03 A1.04 1 1/2" = 1'-0" A1.01 A1.04 1 1/2" = 1'-0" 2F ROOF DRAIN - BU/MOD BIT A1.01 A1.04 1 1/2" = 1'-0"
REPLACEMENT
A1.01 A1.04 1 1/2" = 1'-0" 2

26 GA. STAINLESS STEEL DRIP EDGE SET IN


ROOF CEMENT, NAILED 3" O.C.. STAGGERED,
PRIME METAL FLANGE PRIOR TO STRIPPING
SEALANT, REFERENCE FRONT LIP 1" LOWER THAN BACK EDGE
MODIFIED BITUMEN SPECIFICATION
MINERAL CAP SHEET
520 S Pinehurst, Salisbury, MD 21801
26 GA. STAINLESS STEEL 2" GUTTER STRAP @ 24" O.C. 1/8"
MODIFIED BITUMEN CONTINUOUS CLEAT 6" O.C. STAINLESS STEEL TO MATCH GUTTER
BASE SHEET EXISTING WOOD BLOCKING
SEALANT, REFERENCE 26 GA. STAINLESS STEEL DRIP EDGE SET IN 2" GUTTER STRAP @ 24" O.C.
SPECIFICATION ROOF CEMENT, NAILED 3" O.C.. STAGGERED, 1/8" STAINLESS STEEL TO 26 GA. STAINLESS STEEL
NOTE: ADJUST WOOD BLOCKING AS NECESSARY MODIFIED BITUMEN 1/2" SECUROCK TORCH MINERAL CAP FLASHING CONTINUOUS CLEAT 6" O.C.
PRIME METAL FLANGE PRIOR TO STRIPPING PLY 9" MIN. ON FIELD MATCH GUTTER
TO ACCOMODATE HEIGHT OF INSULATION. 26 GA. STAINLESS STEEL MINERAL CAP SHEET
CONTINUOUS CLEAT 6" O.C. 4" MIN. FRONT LIP 1" LOWER
EXISTING WOOD BLOCKING MODIFIED BITUMEN BASE SHEET TORCH BASE FLASHING THAN BACK EDGE
2" GUTTER STRAP @ 24" O.C. PLY 6" MIN. ON FIELD
1/8" STAINLESS STEEL TO TORCH MINERAL CAP FLASHING 1/2" SECUROCK 26 GA. STAINLESS STEEL SEALANT, REFERENCE SPECIFICATION
MATCH GUTTER PLY 9" MIN. ON FIELD D-STYLE GUTTER
FRONT LIP 1" LOWER 4" MIN. BASE SHEET & VAPOR BARRIER
THAN BACK EDGE TORCH BASE FLASHING
POLYISOCYANURATE INSULATION 26 GA. STAINLESS STEEL DRIP EDGE SET IN
26 GA. STAINLESS STEEL
PLY 6" MIN. ON FIELD LEAD WEDGE 18" O.C. ROOF CEMENT, NAILED 3" O.C.. STAGGERED, 3
D-STYLE GUTTER PRIME METAL FLANGE PRIOR TO STRIPPING
SEALANT, REFERENCE SEALANT, SEE SPECIFICATION
SPECIFICATION
LEAD WEDGE 18" O.C. EXISTING WOOD BLOCKING
26 GA. REGLETMOUNTED STAINLESS
26 GA. STAINLESS STEEL STEEL COUNTERFLASHING
CONTINUOUS CLEAT 6" O.C. SEALANT, SEE SPECIFICATION BASE SHEET & TORCH MINERAL CAP FLASHING
VAPOR BARRIER TERMINATION BAR FASTENED @ 8" O.C. PLY 9" MIN. ON FIELD
26 GA. REGLETMOUNTED STAINLESS
POLYISOCYANURATE THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT) 4" MIN.
2" GUTTER STRAP @ 24" O.C. STEEL COUNTERFLASHING
INSULATION TORCH BASE FLASHING
1/8" STAINLESS STEEL TO TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TERMINATION BAR FASTENED @ 8" O.C. PLY 6" MIN. ON FIELD
MATCH GUTTER
THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT) TORCH BASE FLASHING PLY 6" MIN. ON FIELD
EXISTING DECK
FRONT LIP 1" LOWER TORCH MINERAL CAP FLASHING
THAN BACK EDGE PLY 9" MIN. ON FIELD 1/2" SECUROCK BASE SHEET & VAPOR BARRIER
TORCH BASE FLASHING
26 GA. STAINLESS STEEL PLY 6" MIN. ON FIELD 1/2" SECUROCK
D-STYLE GUTTER

SEAL GAPS AT ALL PERIMETERS WITH FOAM


SEAL GAPS AT ALL PERIMETERS WITH FOAM EXISTING DECK 4
GUTTER CLEAT FASTENED 6" O.C.
GUTTER CLEAT FASTENED 6" O.C.
EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
2" GUTTER STRAP @ 24"
O.C. 1/8" STAINLESS STEEL EXTEND PLY OVER BLOCKING FASTEN 8" O.C.
TO MATCH GUTTER 2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS
STEEL TO MATCH GUTTER
2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS
STEEL TO MATCH GUTTER SECUROCK
WRAP EXISTING WOOD WITH NEW SEAL GAPS AT ALL PERIMETERS WITH FOAM
ALUMINUM AS REQUIRED
BASE SHEET & VAPOR BARRIER
EXISTING 3/8" PLYWOOD GUTTER CLEAT FASTENED 6" O.C.
SEALANT

EXISTING 1/2" PLYWOOD EXTEND PLY OVER BLOCKING FASTEN 8" O.C.

NOTE: ADJUST WOOD BLOCKING AS NECESSARY


TAPERED INSULATION TO ACCOMODATE HEIGHT OF INSULATION. 2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS
STEEL TO MATCH GUTTER

WING WALL BEYOND 5


26 GA. STAINLESS STEEL D-STYLE GUTTER

5A ROOF EDGE DETAIL 1963 BUILDING AT CANOPY 5G ROOF EDGE DETAIL 1963 BUILDING ARCHITECTURE
A1.01 A1.04 1 1/2" = 1'-0" A1.01 A1.04 1 1/2" = 1'-0" LANDSCAPE ARCHITECTURE

PLANNING

INTERIOR DESIGN

EXISTING ROOF TO REMAIN 6


LEAD WEDGE 18" O.C.

SEALANT, SEE SPECIFICATION


26 GA. STAINLESS STEEL COUNTERFLASHING
SLOPED ROOF SOFFIT BEYOND TO REMAIN SEALANT, REFERENCE SPECIFICATION
TERMINATION BAR FASTENED @ 8" O.C.
SEALANT, SEE SPECIFICATION
THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT)
PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
SCUPPER FROM SLOPED ROOFS ABOVE 26 GA. STAINLESS STEEL COUNTERFLASHING
TORCH MINERAL CAP FLASHING PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
RETURN AT WINDOW SILL UNDER THE LAWS OF THE STATE OF MARYLAND
PLY 9" MIN. ON FIELD LICENSE NUMBER:
26 GA. STAINLESS STEEL EXPIRATION DATE:
SEALANT, REFERENCE SPECIFICATION POLYISOCYANURATE INSULATION
CONTINUOUS CLEAT 6" O.C. TORCH BASE FLASHING
WINDOW TERMINATION BAR FASTENED @ 8" O.C. PLY 6" MIN. ON FIELD
THROUGH BUTYL TAPE (MIN. 1.5' EMBEDMENT) MODIFIED BITUMEN CAP SHEET
2" GUTTER STRAP @ 24" O.C. 1/8" WINDOW
SEALANT STAINLESS STEEL TO MATCH GUTTER TORCH MINERAL CAP FLASHING CANT STRIP MODIFIED BITUMEN BASE SHEET
PLY 9" MIN. ON FIELD
7
FRONT LIP 1" LOWER THAN BACK EDGE
POLYISOCYANURATE INSULATION 1/2" SECUROCK
26 GA. STAINLESS STEEL TORCH BASE FLASHING
26 GA. STAINLESS STEEL D-STYLE GUTTER PLY 6" MIN. ON FIELD
COUNTERFLASHING MODIFIED BITUMEN CAP SHEET
RETURN AT WINDOW SILL 2" GUTTER STRAP @ 24" O.C. 1/8" STAINLESS
STEEL TO MATCH GUTTER CANT STRIP
MODIFIED BITUMEN BASE SHEET
TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD
TORCH BASE FLASHING PLY 6" MIN. ON FIELD 1/2" SECUROCK
no. date revision

GUTTER CLEAT Project Name


FASTENED 6" O.C. PINEHURST ELEMENTARY
SCHOOL ROOF REPLACEMENT
Project Number
218345.00
CANT STRIP METAL DECK
1/2" SECUROCK Date
BASE SHEET & VAPOR BARRIER FEBRUARY 11, 2019
8
Scale
SEAL GAPS AT ALL PERIMETERS WITH FOAM 1 1/2" = 1'-0"
1/2" SECUROCK Drawing
SECUROCK ROOF DETAILS
BASE SHEET & VAPOR BARRIER
POLUISOCYANURATE INSULATION 1963 BUILDING 1937 BUILDING

BASE SHEET & VAPOR BARRIER

1/2" SECUROCK
EXISTING ROOF DECK

A1.04
9A ROOF EDGE DETAIL 1963 BUILDING @ CAFETERIA 9D ROOF EDGE DETAIL 1963 BUILDING @ 1937 BUILDING 9H ROOF EDGE DETAIL 1968 BUILDING @ SOUTH SLOPED ROOF
A1.01 A1.04 1 1/2" = 1'-0" A1.01 A1.04 1 1/2" = 1'-0" A1.01 A1.04 1 1/2" = 1'-0"

CONSTRUCTION DOCUMENTS
9
2/11/2019 1:34:30 PM
A B C D E F G H J K L M C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt © Hord Coplan Macht, Inc.
LEAD WEDGE @ 18" O.C.
ARCHITECT
SEALANT, SEE SPECIFICATION 1968 BUILDING 1961 BUILDING Hord Coplan Macht, Inc.
26 GA. STAINLESS STEEL COUNTERFLASHING 700 E. Pratt St, Suite 1200
Baltimore, MD 21202
SEALANT, REFERENCE SPECIFICATION p. 410. 837. 7311 f. 410. 837. 6530
TERMINATION BAR FASTENED @ 8" O.C. 2A ENVELOPE CONSULTANT
THROUGH BUTYL TAPE (MIN. 1.5" EMBEDMENT) A1.04
POLYISOCYANURATE INSULATION Construction Systems Group, Inc.
2A 1451 Dolley Madison Blvd., Suite 300
TORCH MINERAL CAP FLASHING
A1.04 MODIFIED BITUMEN CAP SHEET McLean, VA 22101
PLY 9" MIN. ON FIELD 1986 ADDITION 1971 ADDITION
EXPANSION p. 703.917.0055 f. 703.917.0464
JOINT MODIFIED BITUMEN BASE SHEET
TORCH BASE FLASHING POLYISOCYANURATE INSULATION
PLY 6" MIN. ON FIELD
MODIFIED BITUMEN CAP SHEET 1/2" SECUROCK
EXPANSION
CANT STRIP MODIFIED BITUMEN BASE SHEET
JOINT

8" MIN.
1/2" SECUROCK
1

WICOMICO COUNTY PUBLIC


SCHOOLS
BASE SHEET &
VAPOR BARRIER

BASE SHEET &


VAPOR BARRIER
EXISTING TECTUM DECK
PINEHURST
EXISTING METAL DECK
ELEMENTARY
1/2" SECUROCK
SCHOOL ROOF
SEAL GAPS AT ALL
PERIMETERS WITH FOAM
BASE SHEET & VAPOR BARRIER 2
REPLACEMENT

520 S Pinehurst, Salisbury, MD 21801

3A ROOF EDGE DETAIL 1986 BUILDING TO 1971 BUILDING 3G ROOF EDGE DETAIL 1961 BUILDING @ 1968 BUILDING
A1.01 A1.05 1 1/2" = 1'-0" A1.01 A1.05 1 1/2" = 1'-0"
3

NOTE: ADJUST WOOD BLOCKING AS NECESSARY GUTTER CLEAT FASTENED 6" O.C.
TO ACCOMODATE HEIGHT OF INSULATION.

SEALANT, REFERENCE
SPECIFICATION

NOTE:
INCREASE HEIGHT OF CURB AS NECESSARY TO 26 GA. STAINLESS STEEL DRIP EDGE MODIFIED BITUMEN
MAINTAIN MINIMUM FLASHING HEIGHT SET IN ROOF CEMENT, NAILED 3" MINERAL CAP SHEET
O.C.. STAGGERED, PRIME METAL
FLANGE PRIOR TO STRIPPING EXISTING WOOD BLOCKING MODIFIED BITUMEN BASE SHEET

EXISTING METAL EXHAUST COVER TORCH MINERAL CAP FLASHING 1/2" SECUROCK
26 GA. STAINLESS STEEL PLY 9" MIN. ON FIELD
CONTINUOUS CLEAT 6" O.C. 4" MIN. BASE SHEET & VAPOR BARRIER
TORCH BASE FLASHING
EXTEND PLY OVER PLY 6" MIN. ON FIELD POLYISOCYANURATE INSULATION
BLOCKING FASTEN 8" O.C. 4

SEALANT, REFERENCE
NEW METAL COUNTERFLASHING. 26 GA.
SPECIFICATION
STAINLESS STEEL, 1/8" RIVET EVERY 12"O.C.

TERMINATION BAR FRONT LIP 1" LOWER


FASTENED @ 8" O.C. TORCH MINERAL CAP FLASHING PLY 9" MIN. ON FIELD THAN BACK EDGE
THROUGH BUTYL TAPE
TORCH BASE FLASHING PLY 6" MIN. ON FIELD 2" GUTTER STRAP @ 24" O.C.
MODIFIED BITUMEN CAP SHEET 1/8" STAINLESS STEEL TO
MATCH GUTTER
8" MIN.

MODIFIED BITUMEN BASE SHEET


26 GA. STAINLESS STEEL
D-STYLE GUTTER
1/2" SECUROCK
2" GUTTER STRAP @ 24" O.C.
1/8" STAINLESS STEEL TO
MATCH GUTTER EXISTING STRUCTURE 5

EXISTING WOOD BLOCKING EXISTING METAL LATH & ARCHITECTURE


WITH NEW ALUMINUM WRAP STUCCO SOFFIT
LANDSCAPE ARCHITECTURE
POLYISOCYANURATE
CANT STRIP, SEALANT
INSULATION EXISTING TECTUM ROOF DECK PLANNING
FASTENED TO NAILER
BASE SHEET & SEAL GAPS AT ALL PERIMETERS WITH FOAM INTERIOR DESIGN
VAPOR BARRIER EXISTING SOFFIT VENT

EXISTING TECTUM DECK

6A EQUIP CURB - BU/MOD BIT 6E ROOF EDGE DETAIL 1968 BUILDING @ NORTH
A1.05 1 1/2" = 1'-0" A1.01 A1.05 1 1/2" = 1'-0"

26 GA. STAINLESS STEEL DRIP EDGE SET IN


GUTTER CLEAT FASTENED 6" O.C. ROOF CEMENT, NAILED 3" O.C.. STAGGERED,
PRIME METAL FLANGE PRIOR TO STRIPPING
MODIFIED BITUMEN
SEALANT, REFERENCE MINERAL CAP SHEET
SPECIFICATION
EXISTING WOOD BLOCKING MODIFIED BITUMEN BASE SHEET
MODIFIED BITUMEN
MINERAL CAP SHEET
TORCH MINERAL CAP FLASHING 1/2" SECUROCK
26 GA. STAINLESS STEEL DRIP EDGE PLY 9" MIN. ON FIELD PROFESSIONAL CERTIFICATION: I CERTIFY THAT THESE DOCUMENTS WERE
SET IN ROOF CEMENT, NAILED 3" SEALANT, REFERENCE PREPARED OR APPROVED BY ME, AND THAT I AM A DULY LICENSED ARCHITECT
MODIFIED BITUMEN SPECIFICATION 4" MIN. BASE SHEET & VAPOR BARRIER
O.C.. STAGGERED, PRIME METAL BASE SHEET
UNDER THE LAWS OF THE STATE OF MARYLAND
EXISTING WOOD BLOCKING TORCH BASE FLASHING LICENSE NUMBER:
FLANGE PRIOR TO STRIPPING
PLY 6" MIN. ON FIELD POLYISOCYANURATE INSULATION EXPIRATION DATE:

TORCH MINERAL CAP FLASHING 1/2" SECUROCK


26 GA. STAINLESS STEEL PLY 9" MIN. ON FIELD 26 GA. STAINLESS STEEL
CONTINUOUS CLEAT 6" O.C. 4" MIN. CONTINUOUS CLEAT 6" O.C.
TORCH BASE FLASHING
EXTEND PLY OVER PLY 6" MIN. ON FIELD
EXISTING PASSIVE AIR/VENT INTAKE
BLOCKING FASTEN 8" O.C. 7
FRONT LIP 1" LOWER
NEW COUNTERFLASHING, 26 GA. STAINLESS THAN BACK EDGE
STEEL, 1/8" RIVET EVERY 12" O.C.

TORCH MINERAL CAP 2" GUTTER STRAP @ 24" O.C.


SEALANT, REFERENCE FLASHING PLY 9" MIN. ON FIELD FRONT LIP 1" LOWER 1/8" STAINLESS STEEL TO
SPECIFICATION THAN BACK EDGE MATCH GUTTER
no. date revision
TERMINATION BAR TORCH BASE FLASHING PLY 6" MIN. ON FIELD
FASTENED @ 8" O.C. 26 GA. STAINLESS STEEL
2" GUTTER STRAP @ 24" O.C. Project Name
THROUGH BUTYL TAPE D-STYLE GUTTER
1/8" STAINLESS STEEL TO
MATCH GUTTER
PINEHURST ELEMENTARY
MODIFIED BITUMEN CAP SHEET
2" GUTTER STRAP @ 24" O.C. SCHOOL ROOF REPLACEMENT
4" MIN.

1/8" STAINLESS STEEL TO EXISTING TECTUM DECK


8" MIN.

MODIFIED BITUMEN BASE SHEET 26 GA. STAINLESS STEEL MATCH GUTTER Project Number
D-STYLE GUTTER 218345.00
1/2" SECUROCK SEAL GAPS AT ALL PERIMETERS WITH FOAM
2" GUTTER STRAP @ 24" O.C. Date
1/8" STAINLESS STEEL TO EXISTING TECTUM FEBRUARY 11, 2019
MATCH GUTTER ROOF DECK GUTTER CLEAT FASTENED 6" O.C. 8
Scale

EXTEND PLY OVER BLOCKING FASTEN 8" O.C.


1 1/2" = 1'-0"
EXISTING WOOD BLOCKING
WITH NEW ALUMINUM WRAP BASE SHEET & VAPOR BARRIER Drawing
CANT STRIP, ROOF DETAILS
FASTENED TO NAILER SEALANT
POLYISOCYANURATE INSULATION POLYISOCYANURATE INSULATION
NOTE: ADJUST WOOD BLOCKING AS NECESSARY
SEAL GAPS AT ALL PERIMETERS WITH FOAM TO ACCOMODATE HEIGHT OF INSULATION.
BASE SHEET & VAPOR BARRIER

9A EQUIP CURB - BU/MOD BIT


A1.05 1 1/2" = 1'-0"
EXISTING TECTUM DECK

9E ROOF EDGE DETAIL 1971 BUILDING @ EAST & WEST


A1.01 A1.05 1 1/2" = 1'-0"
9J ROOF EDGE DETAIL 1968 BUILDING @ EAST & WEST
A1.01 A1.05 1 1/2" = 1'-0"
A1.05
CONSTRUCTION DOCUMENTS
9
2/11/2019 1:34:30 PM
A B C D E F G H J K L M C:\Users\jhagan\Documents\Pinehurst ES - Roof Replacement_jhagan.rvt © Hord Coplan Macht, Inc.