Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Specification sheet

Diesel
generator set
NTA855
series engine
315 kVA–400 kVA 50 Hz
300 kW 60 Hz

Description
This Cummins® Power Generation commercial Cooling system – Standard integral set- mounted
generator set is a fully integrated power generation radiator system, designed and tested for rated ambient
system, providing optimum performance, reliability, temperatures, simplifies facility design requirements for
and versatility for stationary standby, prime power, rejected heat.
and continuous duty applications.
Control system – Standard PowerCommand® electronic
control provides total system integration including auto remote
Features start/stop, alarm and status message display.
Cummins® heavy-duty engine – Rugged
4-cycle industrial diesel delivers reliable power, low Enclosures – Optional sound-attenuated enclosures are
emissions and fast response to load changes. available.

Warranty – Backed by a comprehensive warranty


Optional permanent magnet generator and Worldwide distributor network.
(PMG) – Offers enhanced motor starting and
fault clearing short circuit capability.

Alternator – Low reactance 2/3 pitch windings;


low wave form distortion with non-linear loads,
fault clearing short-circuits capability, and class H
insulation.

Standby rating Prime rating Data sheet

50 Hz kVA 60 Hz kW 50 Hz kVA 60 Hz kW
Model
(kW) (kVA) (kW) (kVA) 50 Hz 60 Hz

C315 D5 315 (250) 275 (220) EA_S_CC_39

C350 D5 350 (280) 320 (256) EA_S_CC_40

C375 D5 375 (300) 340 (270) EA_S_CC_41

C400 D5 400 (320) 360 (288) EA_S_CC_42

C300 D6 300 (375) 273 (341) EA_S_CC_43

Our energy working for you.™


www.cumminspower.com
© 2014| Cummins Power Generation Inc.| All rights reserved. “Cummins Power Generation” and “Cummins” are registered
trademarks of Cummins. “PowerCommand®”is the registered trademark of Cummins Power Generation. “Our energy working
for you.™” is the trademark of Cummins Power Generation. Specifications are subject to change without notice.
EA_T_CC_7 V1_1408
Generator Set Specifications

Governor regulation class ISO8528 G2


Voltage regulation (no load to full load) ± 1%
Steady-state voltage variation ± 0.5%
Frequency regulation (no load to full load) Isochronous
Steady-state frequency variation ± 0.5%
EMC compatibility BS EN 61000-6-4 / BS EN 61000-6-2

Engine Specifications
Design 4 cycle; In-line;6-Cylinder
Bore 140 mm (5.5 in.)
Stroke 152 mm (6 in.)
Displacement 14 liter (855 in.3)
Cylinder block Cast iron
Battery capacity 360Ah
Battery charging alternator 35 amps
Starting voltage 24 volt, negative ground
Fuel system Direct injection Cummins PT
Fuel filter Spin on fuel filters with water separator
Air cleaner type Dry replaceable element with restriction indicator
Lube oil filter type(s) Spin on full flow filter
Standard cooling system 104 °F (40 °C) ambient radiator

Alternator Specifications

Design Brushless, single bearing, revolving field


Stator 2/3 pitch
Rotor Single bearing, flexible disc
Insulation system Class H
Standard temperature rise standby,125°C (at 40°C ambient temperature)
Exciter type Self-exciting
Phase rotation A (U), B (V), C (W)
Alternator cooling Direct drive centrifugal blower fan
AC waveform total harmonic distortion (THDV) No load < 1.5%. Non distorting balanced linear load < 5%
Telephone influence factor (TIF) < 50
Telephone harmonic factor (THF) < 2%

Available voltages
50 Hz Line–Neutral/Line–Line 60 Hz Line–Neutral/Line–Line
• 254/440 • 127/254 • 277/480 • 138/277
• 240/415 • 120/240 • 266/460 • 133/230
• 231/400 • 115/230 • 254/440 • 127/250
• 220/380 • 110/220 • 240/416 • 120/240

Generator set options and accessories


Engine Enclosure Circuit breaker Silencer
Heavy duty air filter Sound attenuated canopy 3 pole main circuit breaker 9 dB attenuation critical silencer
Water jacket heater 220/240 V 25 dB residential – delivered loose
Cooling Alternator Warranty
Antifreeze 50/50 (ethylene Alternator heater 5 years for standby application
glycol) Exciter voltage regulator(PMG) 2 years for prime application

*Note: Some options may not be available on all models - consult factory for availability

Our energy working for you.™


www.cumminspower.com
© 2014 |Cummins Power Generation Inc | All rights reserved. “Cummins Power Generation” and “Cummins” are registered
trademarks of Cummins. “PowerCommand®”is the registered trademark of Cummins Power Generation. “Our energy working
for you.™” is the trademark of Cummins Power Generation. Specifications are subject to change without notice.
EA_T_CC_7 V1_1408
Control system
Generator set control PowerCommand® 1.2 – Major features
The PowerCommand® 1.2 control is a microprocessor based
 12 or 24 VDC battery operation.
generator set monitoring control system. The control provides a
 Digital engine speed governing to provide isochronous
simple operator interface to the generator set, digital voltage
frequency regulation.
regulation, digital engine speed governing, start/stop control and
 Digital voltage regulation full wave rectified single phase (line to
protective functions.
line) sensing
 The PowerCommand 1.2 control is suitable for use on a wide
®  Generator set monitoring monitors status of all critical engine
range of generator sets in non-paralleling applications. and alternator conditions functions.
 The PowerCommand control can be configured for any
®  Engine starting includes relay drivers for start and fuel shut off
frequency, voltage and power configuration from 120 to 600 (FSO).
VAC for 50 Hz or 60 Hz operation.  Configurable inputs and outputs – two discrete inputs and two
 Power for the control is derived from the generator set starting dry contact relay outputs.
batteries. The control functions over a voltage range from 8  Smart starting control system – integreated fuel ramping to limit
VDC to 35 VDC. black smoke and frequency overshoot.
 A larger HMI reduces setup time, provides more information  Advanced serviceability using InPower™, a PC based software
per screen, enhanced navigation and serviceability. service tool.
 Includes all functions to locally or remotely start and stop, and Base engine protection
protect the generator set.
 Low oil pressure shutdown
 Control switch – RUN/OFF/AUTO.
 High engine temperature shutdown
 OFF mode – the generator set is shut down and cannot be
 Under speed/sensor fail shutdown
started, as well as reset faults.
 Fail to start
 RUN mode – the generator set will execute its start sequence.
 Battery charging alternator fail warning
 AUTO mode – the generator set can be started with a start
signal from a remote device. HMI220 operator interface

Status indications – The control has a lamp driver for external  Back-lit graphics 128 x 128 LCD display
fault/status indication. Functions include:  English text and symbolic overlay
 Multiple language LCD screens
 The lamp flashes during preheat (when used) and while the
 Dedicated manual/off/auto function switches with mode LEDs
generator set is starting.
and configurable access code (key switch)
 READY TO LOAD – flashing until the set is at rated voltage
 Control set-up without PC-based tool (InPower)
and frequency, then on continuously.
 UL508 recognized/CSA certified/CE compliant
 Fault conditions are displayed by flashing a two-digit fault code
 Multiple HMIs per generator set (one local and one remote)
number.
 Plug and play operatio

LED indicating lamps – includes LED indicating lamps for the


following functions:
PowerCommand®1.2
 Remote start
 Warning
 Shutdown
 Auto
 Run
 Remote emergency stop switch input. Immediate shut down of
the generator set on operation

PCC1302 HMI220

Our energy working for you.™


www.cumminspower.com
© 2014 |Cummins Power Generation Inc | All rights reserved. “Cummins Power Generation” and “Cummins” are registered
trademarks of Cummins. “PowerCommand®”is the registered trademark of Cummins Power Generation. “Our energy working
for you.™” is the trademark of Cummins Power Generation. Specifications are subject to change without notice.
EA_T_CC_7 V1_1408
Ratings definitions
Emergency standby power (ESP):
Applicable for supplying power to varying electrical load for the
duration of power interruption of a reliable utility source.
Emergency standby power (ESP) is in accordance with ISO 8528.
Fuel stop power in accordance with ISO 3046, AS 2789, DIN
6271 and BS 5514.

Limited-time running power (LTP):


Applicable for supplying power to a constant electrical load for
limited hours. Limited time running power (LTP) is in accordance This outline drawing is to provide representative configuration
details for Model series only.
with ISO 8528.
See respective model data sheet for specific model outline
Prime power (PRP): drawing number.
Applicable for supplying power to varying electrical load for
unlimited hours. Prime power (PRP) is in accordance with ISO
Do not use for installation design
8528. Ten percent overload capability is available in
accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.

Base load (continuous) power (COP):


Applicable for supplying power continuously to a
constant electrical load for unlimited hours. Continuous
power (COP) in accordance with ISO 8528, ISO 3046,
AS 2789, DIN 6271 and BS 5514.

Weight and dimensions


A. Open
Model A, mm B, mm C, mm Dry Wt.* (kg) Wet Wt.* (kg)
C315 D5 3558 1100 2002 3037 3227
C350 D5 3558 1100 2002 3037 3227
C375 D5 3558 1100 2002 3037 3227
C400 D5 3558 1100 2002 3037 3227
C300 D6 3558 1100 2002 3037 3227
B. Enclosed
Model A, mm B, mm C, mm Dry Wt.* (kg) Wet Wt.* (kg)
C315 D5 5110 1500 2890 4921 5698
C350 D5 5110 1500 2890 4921 5698
C375 D5 5110 1500 2890 4921 5698
C400 D5 5110 1500 2890 4921 5698
C300 D6 5110 1500 2890 4921 5698
*Note: Weights represent a set with standard features. See outline drawings for weights of other configurations.

Certifications
This generator set is designed in facilities
certified to ISO 9001 and manufactured in This generator set has been designed to
facilities certified to ISO 9001 or ISO 9002.
ISO 8528 comply with ISO 8528 regulation.

Cummins Power Generation

East Asia Asia Pacific Europe, CIS, Middle East and Africa
2 Rongchang East Street 10 Toh Guan Road #07-01 Manston Park Columbus Ave
Beijing Economic-Technological TT International Tradepark Manston, Ramsgate
Development Area Singapore 608838 Kent CT12 BF United Kingdom
Beijing 1000176 P.R China Phone 65 6417 2388 Phone 44 1843 255000
Phone86 10 5902 3000 Fax 65 6417 2399 Fax 44 1843 255902
Fax86 10 5902 319

Our energy working for you.™


www.cumminspower.com
© 2014 |Cummins Power Generation Inc | All rights reserved. “Cummins Power Generation” and “Cummins” are registered
trademarks of Cummins. “PowerCommand®”is the registered trademark of Cummins Power Generation. “Our energy working
for you.™” is the trademark of Cummins Power Generation. Specifications are subject to change without notice.
EA_T_CC_7 V1_1408