Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTES

DRAWINGS AND ACCOMPANYING SPECIFICATIONS AS


Y1 1 2 3 4 5 Y2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Y3 Y4 Y5 Y6 INSTRUMENTS OF SERVICE, ARE THE EXCLUSIVE
PROPERTY OF TALATI & PANTHAKY-ASSOCIATED PVT.
LTD. AND THEIR USE AND PUBLICATIONS SHALL BE
1 1 RESTRICTED TO THE ORIGINAL SITE FOR WHICH THEY
1
A708 A709 WERE PREPARED.
A704
RE-USE, REPRODUCTIONS OR PUBLICATION BY ANY
METHOD IN WHOLE OR PART IS PROHIBITED EXCEPT BY
WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO
1 THESE PLANS & SPECIFICATIONS SHALL REMAIN WITH
THE ARCHITECT WITHOUT PREJUDICE AND VISUAL
A500 CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIE
4
EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.
A704
X1 CONTRACTORS MUST VERIFY DIMENSIONS ON THE JOB
AND REPORT DISCREPANCIES IF ANY IN WRITING, TO THE
ARCHITECT'S OFFICE.
X2 DRAWINGS NOT TO BE SCALED, WRITTEN DIMENSIONS
DUMMY WALL
TO BE FOLLOWED.
-8170 (THICKNESS AS
FFL PER APPROVAL) STORE ROOM FOR STRUCTURAL DETAILS REFER R.C.C CONSULTANTS
STORE DRAWINGS.
2 WHEELER ROOM
3 PARKING D1 D1 FOR SERVICES DETAILS REFER M.E.P. CONSULTANTS
RO A505 DRAWINGS.
REJECTED DRAWING NOTES:
WATER 1) CERTAIN CUT-OUTS,SLEEVE DETAILS, DUCT DETAILS AND
UGWT D1 STORE OPENINGS SHALL BE FINALIZED ONLY ONCE THE FINAL
UP DN
ROOM MEP/CFO LAYOUTS ARE RECEIVED FROM THE RESPECTIVE
A CONSULTANT
D7 2 WHEELER 1. DO NOT SCALE FROM THE DRAWINGS.
PARKING HVAC 2. ALL DIMENSIONS ARE IN MM UNLESS NOTED OTHERWISE.
B 3. ALL LEVELS ARE IN METERS, INDICATING 'TOP OF
D6 CONCRETE' (TOC) WHEREEVER APPLICABLE.
4 WHEELER PARKING 4. ALL DIMENSIONS TO BE CONFIRMED AT SITE AND
4 WHEELER PARKING 4 WHEELER PARKING X3 APPROVED BY THE ENGINEER
5. THIS DRAWING SHOULD BE READ IN CONJUNCTION
UP DN WITH OTHER RELEVANT CONSULTANTS' DRAWINGS
V3 -8170 STORE
AND CHECKED BEFORE EXECUTION.
ROOM
FFL -8170 6. PROPOSED CONCEPTUAL DRAWING UNLESS OTHERWISE
3 SPECIFIED.
FFL 7. THE DRAWING SHOULD BE CHECKED BY THE MUNICIPAL
DRIVE WAY A504 D1 ARCHITECT IN CONJUNCTION WITH THE APPROVED
SANCTIONED DRAWINGS BEFORE EXECUTION ON SITE.
RO PLANT & STACK 8. FOR RCC AND COLUMN SIZES/CONSTRUCTION, KINDLY
PUMP ROOM PARKING REFER TO THE BEAM AND COLUMN SIZES AND RCC
RAMP UP FROM RAMP DOWN FROM D1 DETAILS FROM THE STRUCTURAL CONSULTANT.
DRIVE WAY

B2 TO B1 B2 TO B3
-8170 KEY PLAN N
STORE
FFL ROOM
4 WHEELER PARKING
RAMP WALL
C
1 D1 1
A710 A710
STORE
RAMP UP RAMP UP ROOM
D
LIFT LIFT
E
W1

W1
D3 LIFT LIFT D3
DRIVE WAY 4 WHEELER PARKING
LD LD
LD LD
F
STEP UP STEP UP
D2 D2 G
-8020
FFL STACK
W2

W2
3 LOBBY 1
4 WHEELER PARKING

D4 D4 4 WHEELER PARKING H
A704 SERVICE LOBBY LOBBY PARKING A705
D2
-8020 DN D4 D4 J
UP
LIFT FFL LIFT DUMMY WALL K
DRIVERS AREA METER ROOM SERVICES (THICKNESS AS
LD LD
PER APPROVAL)
W1

W1
D3 D3
RAW RO D5
WATER WATER
L
R1 DUMMY WALL FOR APPROVAL 21/07/21
UGWT UGWT M
RAMP UP RAMP UP STORE R0 ISSUED FOR CONSTRUCTION 19/05/21
TOILET SECURITY ROOM REV PURPOSE OF ISSUE DATE AUTHORIZED
STAIR AS D1
PER DETAIL
N
V1 D6
HVAC
V2 P GOOD FOR CONSTRUCTION
4 WHEELER PARKING V4
ARCHITECT :
-8170 -8170
FFL FFL
RAMP WALL
TALATI AND PANTHAKY
DRIVE WAY ASSOCIATED DESIGNERS LLP
STORE
STORE CLIENT :
ROOM
ROOM 2 WHEELER PARKING
V3
-8170
ARMAAN

D1
4 WHEELER PARKING 4 WHEELER PARKING
FFL
Q
RAMP UP FROM RAMP DOWN FROM D6
STACK INFRASTRUCTURE

D1
D1 B3 TO B2 B1 TO B2 HVAC PARKING
230MM THK. LOW
HT. WALL @ STORE
1100MM FROM SSL ROOM ASSOCIATE ARCHITECT :
D1 R
STORE
SCARLETT DESIGNS PVT.LTD
2 WHEELER PARKING

ROOM
AHMEDABAD
2 2
STORE D1
A704 A704
ROOM STRUCTURE CONSULTANT :
-8170 DUMMY WALL 2 WHEELER
FFL (THICKNESS AS DRIVE WAY PARKING
X4
PER APPROVAL)
A3-A4, 3rd FLOOR, Safal profitaire, Corporate road,
Nr prahladnagar Garden, S.G.ROAD, Ahm'd-51.
E-mail: contact@duconconsultants.in
X5 PH:40073196,65410630,65410631
4
A704 HVAC SERVICES CONSULTANT :
1 1 1
A708 A704 A709
B-402, Fairdeal House, Near Swastik Cross Roads, Off C.G.Road,
Navarangpura, Ahmedabad-380 009
BASEMENT-2 FLOOR PLAN BSNL : +91-79-26 405 405
1 1 : 125
email : anjaria@anjariaassociates.com | www.anjariaassociates.com
ELECTRICAL SERVICES CONSULTANT :
Antech Consultants &
100MM BLOCK WALL Engineers
BASEMENT-2 DOOR SCHEDULE BASEMENT-2 VENTILATION / WINDOW SCHEDULE 403, Satkar, B/h. Swagat, Off. C.G. Road, Navrangpura, Ahmedabad : 380 009
Telefax : +91 79 2656 1881, 4893 4849
200MM BLOCK WALL UNFINISH DOOR DOOR V / W NAME WIDTH HEIGHT SILL HEIGHT LINTEL COUNT BIM, PLUMBING & FIRE CONSULTANT :
D NAME OPENING SIZE WIDTH HEIGHT SILL LINTEL COUNT V1 600 600 2050 2650 1
230MM BRICK WALL
D1 1200 X 2500 1200 2400 0 2500 12 V2 1100 2250 250 2500 1
D2 1200 X 2500 1200 2400 150 2650 3 V3 3100 2250 250 2500 2
300MM BLOCK WALL
D3 1500 X 2500 1500 2400 150 2650 4 V4 5995 3475 250 3725 1 PROJECT :
115 MM BRICK WALL
D4 1050 X 2500 1050 2400 150 2650 4 W1 1265 2300 350 2650 4
D5 750 X 2500 750 2400 150 2650 1 W2 1835 2300 350 2650 2 THE WATERFALL
AMC PASSING WALL D6 1000 X 2500 1000 2400 0 2500 3
D7 2100 X 2500 2100 2400 0 2500 1 PROJECT NO : AEPL BIM_0058
DRAWING TITLE :
NOTE : BASEMENT-2_WORKING
1) CONSIDERED 100MM THK. FLOOR FINISH DRAWING PLAN
2) CONSIDER ONLY OPEING SIZE FOR W2. WATER SCREEN OR
WATER FALL EFFECT @ LIFT LOBBY AREA WILL BE AS PER DETAIL.
Original Scale Drawn: Checked: Authorised: Size.
AASHIR
AS Date : Date : Date : A1
SHOWN 19-05-2021 19-05-2021 19-05-2021
Drawing Number Rev.
A2B2 R0
21/07/2021 4:07:31 PM

You might also like