Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 1

BINESWAR BRAHMA ENGINEERING COLLEGE

Kokrajhar-783370 (Assam)
DEPARTMENT OF ELECTRICAL ENGINEERING
B. Tech 4th semester class Test
(Power System-I)
Time: 1hr Total Marks: 30
Dtate:16 August 2021
Note: Answer All the questions both part-I (2 marks each) and Part-II (10 marks each)

PART-I
1. Draw AC 3 phase 3 wire distribution system.
2. How sub-stations are classified?
3. What is a ring distributor?
4. What is the factor affected Corona effects and loss with standard formula?
5. Define Surge Impedance Loading. Explain the significance of it in Transmission Line design.
PART-II
I. A two-conductor street main AB, 500 meters in length is fed from both the ends at 250 V. Loads
of 50 A,60 A, 40 A and 30 A are tapped at distances of 100 m, 250 m, 350 m and 400 m from the
end A respectively. If the cross section of the conductors is 1 cm2 and specific resistance of the
material of the conductors is 1.7μ Ω-cm, determine the minimum consumer voltage

II. A balanced 3-phase load of 30 MW is supplied at 132 kV, 50 Hz and 0·85 p.f. lagging by means
of a transmission line. The series impedance of a single conductor is (20 + j52) ohms and the total
phase-neutral admittance is 315 × 10−6 siemens. Using nominal T method, determine:
(i) the A, B, C and D constants of the line (ii) sending end voltage (iii) regulation of the line.

OR
III. a three phase Transmission line conductor were arranged in horizontal spacing with ‘d’ as the
distance between adjacent conductors. If these conductors are rearranged to form an equilateral
triangle with sides equal to ‘then the…?