VDI 3441 - 1977:XTX

X AXIS AS IT IS CONDITION
Operator: AARK METROLOGY

Machine name VTL-1 ROTOR MACHINING Serial number LSML/FA. PV -F009 Targets 21 Linear
Axis under test X Number of runs 2 Alternate bidir Test date Tuesday 2022/10/11 02:05 PM

XTX - Analysis features Environmental conditions


Name Value (µm) Name Start End Min Max
Maximum reversal (U max) 517.7 Air temp [°C] 32.8 33.0 32.8 33.1
Maximum scatter (Ps max) 69.8 Air pressure [mbar] 1005.60 1005.40 1005.40 1005.60
Mean reversal (U Mean) 237.4 Air humidity [%RH] 65 64 64 65
Mean scatter (Ps mean) 37.7 Material temp 1 [°C] Not recorded Not recorded
Positional uncertainty (P) 603.5 Material temp 2 [°C] 31.6 31.6 31.6 31.6
Positional deviation (Pa) 129.9 Material temp 3 [°C] Not recorded Not recorded
Expansion coefficient [ppm/°C] 11.70 11.70