X Axis After Comepensation

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

VDI 3441 - 1977:XTX

X AXIS AFTER COMEPENSATION


Operator: AARK METROLOGY

Machine name VTL-1 ROTOR MACHINING Serial number LSML/FA. PV -F009 Targets 21 Linear
Axis under test X Number of runs 3 Alternate bidir Test date Tuesday 2022/10/11 02:28 PM

XTX - Analysis features Environmental conditions


Name Value (µm) Name Start End Min Max
Maximum reversal (U max) 296.8 Air temp [°C] 32.8 32.8 32.7 32.8
Maximum scatter (Ps max) 39.2 Air pressure [mbar] 1005.20 1005.20 1005.00 1005.20
Mean reversal (U Mean) 89.7 Air humidity [%RH] 66 65 65 66
Mean scatter (Ps mean) 29.2 Material temp 1 [°C] Not recorded Not recorded
Positional uncertainty (P) 333.7 Material temp 2 [°C] 31.7 31.7 31.7 31.7
Positional deviation (Pa) 7.1 Material temp 3 [°C] Not recorded Not recorded
Expansion coefficient [ppm/°C] 11.70 11.70

Renishaw plc CARTO - Explore 4.5 Date printed:Thursday 2022/10/13 11:44 AM

1/1