Proposed Library Building for Pardi Nagarpalika,At-Pardi.

Good For Execution


Column Library Building
Reinforcement
As Per Schedule
12T @ 100 C/C (B/W)
Column Column
FG8 1000 1000 Reinforcement Reinforcement
f e

500
1000
FG9 10T @ 150 C/C (B/W) 2300 As Per Schedule

103
CF5 As Per Schedule
ld

2000
1700

2400
K C23

400
300x600

1000
C24 C25
12T @ 100C/C(B/W) 10T @ 100 C/C (B/W) 10T @ 100 C/C (B/W)

268

200
500x500 300x600
2000
+400 +600 1200
U.G. Tank 2400 2000 10T @ 150 C/C (B/W) 10T @ 150 C/C (B/W)
2730

1300
1600x2000x2500 2000 100mm thk P.C.C. (1:4:8)

200
200
12T @ 100 C/C (B/W) CF1 ld ld
FG8 1200 1000 12T @ 100 C/C (B/W)

400
400
FG7

1100
200
200 200 Extra Bottom

3600
CF4
CF-1_Section - a a

1500
2400

2200
1900
J 2200
C20
C21 2 2000
C3 Sec 100mm thk P.C.C. (1:4:8) 100mm thk P.C.C. (1:4:8)

262
300x600 C22 Scale: 1:50

1100
500x500 300x600 10T @ 100 C/C (B/W) 10T @ 100 C/C (B/W)
2200 300x750 C19,C22
2400 +400 +600

1300
2735

2200 2300
FG8 1200 1000 CF-5_Section - d CF-4_Section - e
FG7 6 9

1100
CF4 Scale: 1:50 Scale: 1:50

2200
2400
1900

H C17 C18
300x600 C19

1300
1100
500x500
300x600
CF1

178
2200 +400 +600
2400
2725

3600
2200
1800 250 a CF-1_Bottom Extra Steel

1100
5

1525

1000
FG7 CF3 1500 Scale: 1:50 CF5
C25 C22
C16 C3 Sec 300x600 300x600
CF4

1800

1800
1900

500x500
300x750 e
3200
G
d

2000

2200
C14

1300
300x600 1675
+1000
C15
+1100 Sec Sec
2200 500x500
+400

1000
10T @ 100C/C(B/W)

1100
2860
20805

3340 500 3060 500 12T @ 100C/C(B/W) 10T @ 100C/C(B/W)


Top of Ground Beam

7400 N.G.L.
FG6
250 0.0M Lvl.
2100

F 2000 2200

L0
CF2
Confining
C13
2290 500 3060 500 CF-1_Bottom Main Steel
2000

Reinforcement
300x600
3 CF-5_Bottom Main Steel CF-4_Bottom Main Steel

2250
2203

2000 1800 Scale: 1:50


7 10

L1
2400 Scale: 1:50 Scale: 1:50
C12
500x500 12T @ 100C/C(B/W) 1200
2700
1800
FG5 Confining
2000

10T @ 100C/C(B/W) 1200


500

E 10T @ 100C/C(B/W)
h

L0
Reinforcement 1000
FG4 g C11
2300 75mm Offset II To L.S. of Column (Top Layer)
1355

+900 +1100
175

500x500

75
FG3
3200

D
2500

Depth Frome N.G.L.


1200

450

2900
7400
Ld+2ds

D
2500

75

1100
d
- 3.0M Lvl. C25 C22

1000
C8
2000 CF5
300x450 1800 300x600 300x600

1300
CF4
1770

C9 100mm thk P.C.C. (1:4:8)


1000 +1000 CF1 e
225

C10
450x600
Section : x-x'

2200

2200
d

2000

2000
500x500
Sec
1500

Column (Bottom)
2000

Sec
750

C 3200

3600
C7
a

3600

II To S.S. of

1000
300x750 10T @ 150C/C(B/W)

1100
50 +800
C6 10T @ 100C/C(B/W)
2250

300x750
75 C3 Sec
1650

2700 +400
2770

300x750
2290 3460 750

1300
a FG4
300 6800 X

ARDI-30-7-2013WARNIM JAYANTILibrary Building & Community HallLibrary BuildingDrgsStr02_Library Building_Column Position_31-08-2021}


Sec.

B
FG3 100 150 2000 2200
II To L.S. of
2500
1200

B 10T @ 150C/C(B/W)
FG1
Column (Top) CF-5_Top Main Steel CF-4_Top Main Steel
C4 a

FG2
1100 1200
8 Scale: 1:50
11 Scale: 1:50
1660

300x450
326

1800

1000 C5
450x600 CF1
2800

C2 C3 L
300x750 300x750
PLAN Footing Notes:-
3200

3600

A
b CF-1_Top Main Steel Typical Footing
1800

1. This Building Designed At Foundation Depth Below Minimum 300mm In Side Good Yellow Soil OR 2.5 Mt From N.G.L. Whichever is Higher
C1
4
500x500
c +400 +600 d Scale: 1:50 2. All Dimensions Are In mm.
3. Unless Noted Otherwise All Structural Elements Shall Be Casted With Concrete Mix- M25. The Proportions Of Mix Shall Be As Per Design
2800 2300
2300
Schedule of Footing :- Design Mix - M25 & Fe500 Mix.
250 4. Making Holes And Cutting Of Reinforcement In R.C.C Elements Is Strictly Prohibited.
2418 5525 1265 1800 1615 3810 P.C.C. Size Footing Size Minimum Total Reinforcement 5. All Laps To Be Staggered In Column As Per Sketch-A.
Footing 6. Relevant Architectural Drawings Shall Be Read In Conjunction With Drawings Provided By Us And Approved By The Concerned Authority.
16683 Column No. Column Size Depth in mm. Depth in mm. II To Short side of Column II To Long side of Column
Group W L W L 7. Clear Cover Of 75 mm For Footing Shall Be Provided.
(d) (D) Dia No Dia No 8. Building Is Designed For Ground Floor +Two+One Future Floors Only.
1 2 3 4 5 6 7 8 FG1 C1. 500 x 500 3100 3100 2800 2800 230 900 10T 28 10T 28 9. Development Length Of Bar For Footings Should Be Maintained.Where Refer Table 1 For LD.
10. Size Of P.C.C. Bedding (1:4:8) Below R.C.C. Footing Shall Be As Mentioned (As Per Tender Condition) In Schedule Of Footings.
FG2 C2. 300 x 750 2600 3500 2300 3200 230 800 10T 32 10T 23 11. Clear Cover Of 50 mm To The Longitudinal Reinforcement For Column Shall Be Provided .
FG3 C4,C8. 300 x 450 1300 1500 1000 1200 230 400 10T 8 10T 7 12. For Use Of Fe500 Steel, Should Have Elongation More Than 16%.
13. Building Is Designed For Seismic Zone-3 As Per IS 1893-2016, IS 13920-2016 Consideration Value Of Importance Factor=1.5
Table:-1 Development Length (Ld) of Bars In mm For Fe500 Grade Steel FG4 C5,C9. 450 x 600 2800 3000 2500 2700 230 750 10T 27 10T 25 14. The Building is Designed For Exposure Condition "Mild" However Minimum Grade Of Concrete is Considered M-25 As Per Tender Condition.
FG5 C10. 500 x 500 2400 3500 3200 3200 230 1100 10T 32 10T 32 15. Top Of Ground Beam Are To Be Placed At N.G.L
Bar Diameter in mm
Grade of Concrete 16. The R.C.C. Design Is Based On Limit State Method And It Stands For High Precision Job And Strict Quality Control. Therefore To Maintain
FG6 C13. 300 x 600 2400 2700 2100 2400 230 700 10T 22 10T 20 Quality And Designed Strength, Number Of Work Test Cubes Of Concrete Should Be Taken And All Efforts Should Be Made To Maintain The
8T 10T 12T 16T 20T 25T 32T
FG7 C14,C17,C20. 300 x 600 2200 2500 1900 2200 230 600 10T 18 10T 16 Quality And Design Strength Through Out The Construction By Following Specification Strictly And Using All The Latest Techniques Of
Structural Framing Plan @ Foundation Lvl. M25 392 490 588 784 980 1225 1568 Concreting For Full Quality Control. Special Use Of Weigh Batch Machine Is Recommended In Order To Keep Precise Control Over The Use
FG8 C18,C21,C24. 500 x 500 2700 2700 2400 2400 230 800 10T 24 10T 24
1 Scale: 1:100 Note :- For M25 Ld=49db
Of Different Aggregates Of Concrete.
FG9 C23 300 x 600 2000 2300 1700 2000 230 600 10T 16 10T 14 17. Discrepancies If Any Shall Be Got Rectified Before Execution.

PROJECT NO. CLIENT : Pardi Nagarpalika Structure: S Reference Drawing: Revision History: NOTES: KEY PLAN: Approval: Scale :
1364/20 Sthapati Designers & Consultants Pvt. Ltd. No. Drg. No. Sheet Title No. Date Remarks By 1).All drawings are in mm. Date By
CONSULTANTS:
Project Name: Electrical: 01 14-02-2022 U.G.Tank Location Added Jignesh 2).All dimensions are to be read and not to be measured.
Design Consultant : D E 0 0 0 0 0
Proposed Library Building for Pardi Nagarpalika,At-Pardi Sthapati Designers & Consultants Pvt. Ltd. Sthapati Designers & Consultants Pvt. Ltd. 3).If there is any descrepancy in the drawing it should be
brought to the notice of the architect immediatly Sheet Title: Structural Framing Plan @ Foundation Lvl.
Project Architect : A Landscape: L
Sthapati Designers & Consultants Pvt.Ltd.
Sthapati Designers & Consultants Pvt. Ltd. Sthapati Designers & Consultants Pvt. Ltd.
Infrastructure Project Consultants Architects-Engineers-Valuers.
Regd. Office:- 'Ohm Chambers' Station Road, Navsari- 396 445 Gujarat, India.
Phone:- (02637) 250 330, 280 330, Fax No.:- 280 330.
Email ID:- sdcplin@yahoo.com, Web Site:- www.sthapati-india.com