54, Islampura Street,

Telelin
INSTRUMENTS (INDIA)
5-A, Ghaswala Bldg., 1st Floor,
Nr. Madhav Baug, Girgaun,
Mumbai - 400 004.
EXPERIENCE : SERVING TO INDUS
OUR ATI S FA CTION OUR T I R ES
MOTO : CU S TO MER S SINC
QUALITY INSTRUMENTS & E 19
78

ROTAMETERS
When fluid or gas flows through a taper tube containing a float, a pressure difference of P1 and
P2 is created between upper and lower side of the float. The float moves upwards by a force
obtained by multiplying the pressure differential by the maximum cross sectional area of the
float.
Due to taper tube, as the float moves upwards, the fluid passing area increases as a result of
which the differential pressure decreases. Upward movement of float stops when the dead load
is dynamically balanced by the differential pressure. Tapering of metering tube is so designed
that the vertical movement of the float becomes linearly proportional to the rate of flow and the
scale is provided to read the position of the float, thus giving birth to flow rate indication.
Based on Bemoulli's theorem, the principle mentioned above can be theoretically expressed as
follows.
FLOW FORMULA

Where
Q = Volumetric flow rate V = Volume of Float
C = Flow coefficient Af = Maximum pressure receiving area of float.
A = Fluid passing Area P = Float Density
g = gravimetric acceleration y = Fluid Density

THERE ARE VARIOUS TYPES OF FLOW METERS AVAILABLE NAMELY :


¾ GLASS TUBE ROTAMETERS ¾ BY-PASS ROTAMETER COMPLETE ASSEMBLIES
¾ PLASTIC BODY ROTAMETERS ¾ GANG / MULTIPLE ROTAMETERS
¾ METAL TUBE ROTAMETERS WITH DIGITAL FLOW RATE INDICATION ¾ ROTEMERS AS PER SAMPLE & OR DRAWING
¾ METEL TUBE ROTAMETER WITH TRANSMITTER
i.e. 4-20 mA output & DIGITAL TOTALISER
( OPERATING ON 4-20mA OUTPUT

DETAILS REQUIRED
ö Name of Fluid ö Position of connections
ö Flow Ranges, Min. & Max. ö Operating Sp. Gr. or Density
ö Line / Connection size ö Operating Viscoity
ö Wetted Parts Material Prefered ö Op. Temp. & Pressure
ö Flanged or Screwed or other End Connections

LOW FLOW PLASTIC BODY ROTAMETERS


with or without Flow Control Valve

FOR AIR OR GASES


Minimum Range : 50 to 500 MI/Min.
Maximum Range : 15 to 150 LPM

FOR WATER OR LIQUIDS


Minimum Range : 10 to 100 CC/Min.
Maximum Range : 1 to 10 LPM

Phone : 91-22-2388 4279 / 2385 3044 / 2387 6566 • Fax : 91-22-2387 6566 / 2385 3044 • Email : teleint@vsnl.com / teleint@gmail.com

Website : www.telelinindia.com
LOW FLOW GLASS TUBE ROTAMETERS
with or without Flow Control Valve

FOR AIR OR GASES


Minimum Range : 5 to 50 MI/Min.
Maximum Range : 15 to 150 LPM

FOR WATER OR LIQUIDS


Minimum Range : 10 to 100 CC/Min.
Maximum Range : 1 to 10 LPM

HIGH FLOW PLASTIC BODY ROTAMETERS


MODEL NO. PB-796 FL / SC
50 50
FOR AIR OR GASES
40 40

Minimum Range : 5 to 50 MI/Min.


30 30

Maximum Range : 400 to 6000 LPM 20 20

FOR WATER OR LIQUIDS 10 10

5 5

Minimum Range : 0.1 to 1 LPM


Maximum Range : 20 to 200 LPM

HIGH FLOW GLASS TUBE ROTAMETERS


MODEL NO. GT-797 FL / FLS / SC
LPM
LPM LPM 70

FOR AIR OR GASES 70 70

60
60 60

Minimum Range : 5 to 50 MI/Min. 50

40
50

40
50

40

Maximum Range : 400 to 6000 LPM 30

20
30

20
30

20
10 10

FOR WATER OR LIQUIDS


5 5
10

Minimum Range : 0.1 to 1 LPM


Maximum Range : 30 to 350 LPM

GANG OR MULTIPLE ROTAMETERS BY-PASS


ASSEMBLIES
MODEL NO. PB-800 / GT-800 for Line Sizes
HAVING COMMON INLET above 2"

OR INDUVISUAL INLETS.

IN CUSTOMERS GIVEN RANGES

FOR GASES OR LIQUIDS

MODEL NO. BYP-3

DIGITAL METAL TUBE MAGNETIC ROTAMETERS


The inner Float Magnetic Field is detected by the high sensitive
mangetic field detection sensor, enable\us to show the digital
readout.
As such this flow meter does not require anyelectrical connection,
since it operates on battery, This got an inbuilt two wire transmitter 24
VDC and take 4-20 mA signal.
If Flow Totalization is required rotameter can be manufactured with
inbuit Flow Totalizer