A319

TECHNICAL TRAINING MANUAL

MECHANICS / ELECTRICS & AVIONICS COURSE

35 OXYGEN
This document must be used for training purpose only

Under no circumstances should this document be used as a reference.

It will not be updated.

All rights reserved.


No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,
without the prior written permission of Airbus Industrie.
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
35 OXYGEN
UEP4200 TABLE OF CONTENTS Page
GENERAL
** System Presentation (1) ....................... 1
CREW OXYGEN SYSTEM
** Crew Oxygen System Presentation (1) .......... 5
** System Controls and Indicating (1) ........... 9
Crew OXY Mask Utiliz/Stowage/Tests (2) ......... 13
Crew Oxygen Components (3) ...................... 23
PASSENGER OXYGEN SYSTEM
** Passenger Oxygen System Presentation (1) .... 37
** Passenger Oxygen System D/O (3) ............. 43
** Passenger Oxygen Unit Operation (3) ......... 55
** Passenger Oxygen Components (3) ............. 63
** Passenger Electrical Circuit (3) ............ 71
PORTABLE OXYGEN SYSTEM
Crew Portable Oxygen System D/O (3) ............ 87
Cabin Portable Oxygen Equipment D/O (3) ........ 95
MAINTENANCE PRACTICES
CREW SYSTEM
Oxygen Cylinder R/I (3) ...................... 103
UEP4200

EFFECTIVITY Page i
ALL 35 CONTENTS Nov 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
35 OXYGEN
UEP4200 TABLE OF CONTENTS Page

THIS PAGE INTENTIONALLY LEFT BLANK


UEP4200

EFFECTIVITY Page ii
ALL 35 CONTENTS Nov 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-00-00 SYSTEM PRESENTATION

CONTENTS:
Crew System
Passenger System
Portable System
Self Examination
TMUOXYA01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 1
1
ALL 35-00-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

SYSTEM PRESENTATION

CREW SYSTEM

The flight crew oxygen system supplies oxygen to the


flight crew if there is a loss of cabin pressurization,
or a smoke emission.
The oxygen is supplied by a high pressure oxygen
cylinder.

PASSENGER SYSTEM

The passenger and cabin attendant oxygen system is


supplied by chemical oxygen generator units.The
chemical generator units provide oxygen for
approximately 13 or 15 minutes.

PORTABLE SYSTEM

The portable oxygen system supplies oxygen to the


passengers, the cabin attendants and the flight crew
in an emergency.
The smoke hood system provides breathing means and eye
protection for the crew members and cabin attendants.It
permits them to move freely to extinguish a fire.
The high pressure portable cylinder with continuous
flow type masks supplies first aid oxygen for the
passengers.
TMUOXYA01-T01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 2
2
ALL 35-00-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYA01-P01 LEVEL 1
UEP4200

SYSTEM PRESENTATION

EFFECTIVITY
EFFECTIVITY Page
Page 3
3
ALL 35-00-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

SELF EXAMINATION

The crew oxygen system consists of :


A - a fixed high pressure cylinder.
B - a high pressure portable cylinder.
C - a fixed cylinder with masks and a
breathing hood system.
TMUOXYA01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 4
4
ALL 35-00-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-10-00 CREW OXYGEN SYSTEM PRESENTATION

CONTENTS:
HP Source
Pressure Regulation
Overpressure Protection
Overpressure Indication
Supply Valve
Distribution
Self Examination
TMUOXYB01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 5
1
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN SYSTEM PRESENTATION

HP SOURCE The pressure relief valve limits the low pressure


oxygen supply to 175 psig.
The crew oxygen source consists of a high pressure
cylinder which can be isolated for maintenance, by a OVERPRESSURE INDICATION
manual ON/OFF valve.
A direct reading pressure gage gives an indication of An overboard green discharge indicator is connected
the cylinder pressure. to the high pressure safety outlet and to the low
Cylinder data pressure safety outlet.
- capacity : 3260 l (115 cu ft) In case of overpressure, the green disk blows out and
- nominal charge : 1850 psig a yellow indicator is displayed showing that the
The cylinder is placed in a cradle and secured by a cylinder has discharged or the pressure relief valve
quick disconnect metallic clamp designed to resist to has opened.
high crash loads.
SUPPLY VALVE
PRESSURE REGULATION
A supply valve enables downstream distribution by crew
The pressure regulator transmitter is directly action on the CREW SUPPLY pushbutton on the oxygen
connected to the cylinder. It consists of a high panel.
pressure stage with an integrated pressure transducer Electrical supply to the valve is applied only for 1.5
for ECAM indication and a low pressure stage. seconds corresponding to the operating time of the
The pressure regulator regulates low pressure valve.
at 78 ± 8 psig.

OVERPRESSURE PROTECTION DISTRIBUTION

High pressure and low pressure protection is achieved A pressure switch and a test port are connected on the
by safety devices consisting of a high pressure safety low pressure manifold.
TMUOXYB01-T01 LEVEL 1

outlet and a low pressure safety outlet. The low pressure switch indicates a low pressure
The high pressure safety outlet is of a frangible disk detection in the LP manifold.
type whereas the low pressure safety outlet is a It activates a message on the ECAM/DOOR/OXY page.
pressure relief valve. Pressure switch setting : 50 psig.
UEP4200

The rupture of the frangible disk is set at a cylinder Test port pressure lower than 145 psig.
pressure of 2500 to 2775 psig.

EFFECTIVITY
EFFECTIVITY Page
Page 6
2
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYB01-P01 LEVEL 1
UEP4200

CREW OXYGEN SYSTEM PRESENTATION

EFFECTIVITY
EFFECTIVITY Page
Page 7
3
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

SELF EXAMINATION

Can the cylinder pressure be checked when there is


no electrical power ?
A - YES
B - NO

What indicates an overboard discharge ?


A - A warning on the oxygen control panel 21
VU.
B - The direct reading pressure gauge on the
oxygen cylinder.
C - A yellow indicator.
TMUOXYB01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 8
4
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-10-00 CREW OXYGEN SYSTEM CONTROLS AND


INDICATIONS

CONTENTS:
HP In Place Visual Indication
Manual Isolation
HP Indication
LP Control
LP Warning
TMUOXYE01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 9
1
ALL 35-10-00 Mar 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN SYSTEM CONTROLS AND INDICATIONS

HP IN PLACE VISUAL INDICATION

The direct reading pressure gage is used to read the


cylinder pressure.

MANUAL ISOLATION

The manual ON/OFF valve allows cylinder isolation.


The pressure gage reading is available whether the
manual valve is open or closed.

HP INDICATION

The HP indication appears on the DOOR/OXY ECAM page.

LP CONTROL

The solenoid supply valve is supplied for a short time


only, corresponding to the valve operating time.
This valve is used to isolate the cylinder from the
rest of the circuit on ground only.

LP WARNING

The REGULATOR LOW PRESSURE message appears amber on


the ECAM DOOR/OXY page in low pressure conditions only.
TMUOXYE01-T01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page10
2
ALL 35-10-00 Mar 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYE01-P01 LEVEL 1
UEP4200

CREW OXYGEN SYSTEM CONTROLS AND INDICATIONS

EFFECTIVITY
EFFECTIVITY Page
Page11
3
ALL 35-10-00 Mar 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYE01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page12
4
ALL 35-10-00 Mar 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-11-00 CREW OXYGEN MASK UTILIZATION,


STOWAGE AND TESTS

CONTENTS:
Operation
Stowage
Tests
TMUOXYC01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page13
1
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN MASK UTILIZATION, STOWAGE AND TESTS

OPERATION

The mask assy and the stowage box are installed


adjacent to each crew member seat. The stowage box
which contains the mask, also controls the flow of
oxygen when the mask is pulled out of the box.
To use the mask, squeeze the red clips, which will
inflate the mask harness ; releasing the red clips
will stop oxygen flow to the harness and vent the
oxygen remaining in the harness to the atmosphere.
TMUOXYC01-T01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page14
2
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYC01-P01 LEVEL 3
UEP4200

CREW OXYGEN MASK UTILIZATION - STOWAGE AND TESTS - OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page15
3
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN MASK UTILIZATION, STOWAGE AND TESTS

OPERATION

Oxygen flow is indicated by the blinker showing yellow


and an "OXY ON" flag which appears on the left door
when closed.
In the normal position, the user breathes a mixture
of cabin air and oxygen.
When the selector is in the 100 % position, the user
will breathe pure oxygen.
To take the mask off, the harness has to be inflated.
This is done by operating the red clips.
TMUOXYC01-T02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page16
4
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYC01-P02 LEVEL 3
UEP4200

CREW OXYGEN MASK UTILIZATION - STOWAGE AND TESTS - OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page17
5
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN MASK UTILIZATION, STOWAGE AND TESTS

STOWAGE

Proper stowing of the mask is essential for quick and


efficient donning of the mask.
Open the stowage box flap doors, and position the
flexible hose correctly.
Engage the mask assy, regulator on top.
Close the left flap door carefully while pushing the
reset test slider to retract the OXY ON flag.
At the end of the restowing operation, do the : IN
SITU TESTING.
TMUOXYC01-T03 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page18
6
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYC01-P03 LEVEL 3
UEP4200

CREW OXYGEN MASK UTILIZATION - STOWAGE AND TESTS - STOWAGE

EFFECTIVITY
EFFECTIVITY Page
Page19
7
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN MASK UTILIZATION, STOWAGE AND TESTS

TESTS

Push the reset test slider. The blinker turns yellow


and goes black again showing that the regulator is
leak tight.
Press the harness inflation control. The blinker turns
yellow and goes black again showing that the harness
is leak tight.
The on demand system is tested by pressing the
emergency rotation knob. The microphone is tested by
activating the loudspeakers, the interphone, and by
pressing the emergency rotation knob.
When the previous tests are completed, make sure that
the NORMAL / 100 % selector is locked in the 100 %
position, and the reset test slider returns to the UP
position.
TMUOXYC01-T04 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page20
8
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYC01-P04 LEVEL 3
UEP4200

CREW OXYGEN MASK UTILIZATION - STOWAGE AND TESTS - TESTS

EFFECTIVITY
EFFECTIVITY Page
Page21
9
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYC01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 22
10
ALL 35-11-00 Oct 31/99
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-10-00 CREW OXYGEN COMPONENTS

CONTENTS:
Safety Precautions
Cylinder Valve Assembly
Regulator Transmitter
Solenoid Valve
Discharge Indicator
LP Manifold
Test Port
Stowage Boxes
Crew Masks
TMUOXYD01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page23
1
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN COMPONENTS

SAFETY PRECAUTIONS CYLINDER VALVE ASSEMBLY

WARNING: KEEP ALL HYDROCARBONS (FUELS, LUBRICANTS, IDENTIFICATION


ETC.) AWAY FROM OXYGEN SOURCES. OXYGEN FIN: 5750HM
BECOMES EXPLOSIVE WHEN IT COMES IN CONTACT
WITH HYDROCARBONS. LOCATION
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE ZONE: 125
CLEAN TO PREVENT CONTAMINATION OF THE OXYGEN
SYSTEM. DESCRIPTION
The cylinder valve assembly includes:
CAUTIONS: PUT DRY & CLEAN, METAL OR PLASTIC PLUGS ON - a manual slow opening valve,
ALL PIPES OR UNITS REMOVED TEMPORARILY. PUT - a direct reading pressure gage connected
EACH PIPE OR UNIT IN A SEALED VINYL BAG. upstream of the manual valve,
- a high pressure safety outlet fitted with a
frangible disk.
TMUOXYD01-T01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page24
2
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYD01-P01 LEVEL 3
UEP4200

CREW OXYGEN COMPONENTS - CYLINDER VALVE ASSEMBLY

EFFECTIVITY
EFFECTIVITY Page
Page25
3
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN COMPONENTS

REGULATOR TRANSMITTER SOLENOID VALVE

IDENTIFICATION IDENTIFICATION
FIN: 4HT FIN: 3HT

LOCATION LOCATION
ZONE: 125 ZONE: 125

DESCRIPTION
The oxygen pressure regulator/transmitter is screwed
to the outlet connection of the cylinder valve
assembly.
TMUOXYD01-T02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page26
4
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYD01-P02 LEVEL 3
UEP4200

CREW OXYGEN COMPONENTS - REGULATOR TRANSMITTER

EFFECTIVITY
EFFECTIVITY Page
Page27
5
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN COMPONENTS

DISCHARGE INDICATOR

IDENTIFICATION
FIN: 5756HM

LOCATION
ZONE: 125

DESCRIPTION
The green disc will be blown out under an oxygen
pressure of 40 to 100 psi, then show a yellow indicator.
TMUOXYD01-T03 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page28
6
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYD01-P04 LEVEL 3
UEP4200

CREW OXYGEN COMPONENTS - DISCHARGE INDICATOR

EFFECTIVITY
EFFECTIVITY Page
Page29
7
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN COMPONENTS

LP MANIFOLD

IDENTIFICATION
FIN: 5753HM

LOCATION
ZONE: 125
TMUOXYD01-T05 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page30
8
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYD01-P05 LEVEL 3
UEP4200

CREW OXYGEN COMPONENTS - LP MANIFOLD

EFFECTIVITY
EFFECTIVITY Page
Page31
9
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN COMPONENTS

TEST PORT

IDENTIFICATION
FIN: 5755HM

LOCATION
ZONE: 125

DESCRIPTION
The test port is composed of:
- a body allowing the connection for testing,
- an internal filter,
- an internal self sealing valve,
- a cap (attached with a small chain) to
protect the inlet.
TMUOXYD01-P06 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 32
10
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYD01-P06 LEVEL 3
UEP4200

CREW OXYGEN COMPONENTS - TEST PORT

EFFECTIVITY
EFFECTIVITY Page
Page 33
11
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW OXYGEN COMPONENTS

STOWAGE BOXES CREW MASKS

IDENTIFICATION IDENTIFICATION
FIN: 10RN1, 10RN2, 10RN3, (5774HM) FIN: 5757HM, 5758HM, 5759HM, (5760HM)

LOCATION LOCATION
ZONE: 211, 212 ZONE: 211, 212

DESCRIPTION DESCRIPTION
The supply valve is opened either by means of the LH One mask is required for each cockpit occupant. Masks
door or via the RESET TEST slider. fitted at the Captain and First Officer stations must
have serviceable mikes.
TMUOXYD01-T07 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 34
12
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYD01-P07 LEVEL 3
UEP4200

CREW OXYGEN COMPONENTS - STOWAGE BOXES - CREW MASKS

EFFECTIVITY
EFFECTIVITY Page
Page 35
13
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYD01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 36
14
ALL 35-10-00 Jul 31/98
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-20-00 PASSENGER OXYGEN SYSTEM


PRESENTATION

CONTENTS:
Location
Logic
TMUOXYJ02 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page37
1
ALL 35-20-00 Mar 31/94
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM PRESENTATION

LOCATION

Chemical oxygen units supply oxygen to passengers


and cabin attendants.
Demo masks are provided for passenger briefings.
The oxygen units are installed in the passenger
compartment as follows:
- above the passenger seats
- in the lavatories
- at the cabin attendant stations.
Two, three or four mask units can be installed on
request depending on cabin layout.
TMUOXYJ02-T01 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page38
2
ALL 35-20-00 Mar 31/94
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYJ02-P01 LEVEL 1
UEP4200

PASSENGER OXYGEN SYSTEM PRESENTATION

EFFECTIVITY
EFFECTIVITY Page
Page39
3
ALL 35-20-00 Mar 31/94
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM PRESENTATION

LOGIC

The masks are presented automatically when the cabin


altitude is higher than 14000 feet or manually on crew
action through the MASK MANUAL ON pushbutton.
The passenger "SYS ON" indicator light comes on white
when the passenger oxygen system is electrically
operated.
A reset is available to rearm the electrical system
after mask restowage.
A release tool allows mechanical opening of the door
in case of failure of the container door opening
system.
TMUOXYJ02-T02 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page40
4
ALL 35-20-00 Mar 31/94
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYJ02-P02 LEVEL 1
UEP4200

PASSENGER OXYGEN SYSTEM PRESENTATION

EFFECTIVITY
EFFECTIVITY Page
Page41
5
ALL 35-20-00 Mar 31/94
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYJ02 LEVEL 1
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page42
6
ALL 35-20-00 Mar 31/94
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-21-00 PASSENGER OXYGEN DESCRIPTION AND


OPERATION

Contents:
Triggering
Automatic Operation
Manual Operation
Reset Operation
Fault Operation
Self Examination
TMUOXYR01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page43
1
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN DESCRIPTION AND OPERATION

TRIGGERING

The chemical oxygen generator supplies a flow of low


pressure oxygen for a minimum time of 13 or 15 minutes.
In case of rapid cabin depressurization, oxygen masks
are automatically presented to passengers.
TMUOXYR01-T01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page44
2
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYR01-P01 LEVEL 3
UEP4200

PASSENGER OXYGEN DESCRIPTION AND OPERATION - TRIGGERING

EFFECTIVITY
EFFECTIVITY Page
Page45
3
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN DESCRIPTION AND OPERATION

AUTOMATIC OPERATION

The system operates automatically when the altitude


pressure switch closes.
A taped announcement is transmitted over the passenger
address system.
The SYS ON white indicator light comes on.
The TIME DELAY RELAYS switch off the power supply to
the OXYGEN POWER RELAYS after 30 s.
The announcement may be stopped by pressing momentarily
the TMR RESET pushbutton.
TMUOXYR01-T02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page46
4
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYR01-P02 LEVEL 3
UEP4200

PASSENGER OXYGEN DESCRIPTION AND OPERATION - AUTOMATIC OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page47
5
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN DESCRIPTION AND OPERATION

MANUAL OPERATION

The passenger oxygen masks may be presented at any


time by pressing the MASK MAN ON pushbutton.
The taped announcement may be stopped by momentarily
pressing the TMR RESET pushbutton.
TMUOXYR01-T03 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page48
6
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYR01-P03 LEVEL 3
UEP4200

PASSENGER OXYGEN DESCRIPTION AND OPERATION - MANUAL OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page49
7
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN DESCRIPTION AND OPERATION

RESET OPERATION

When the TMR RESET pushbutton is pressed, the ON white


light of the TMR RESET pushbutton comes on.
The indicator light SYS ON goes off and the taped
announcement stops.
On ground, used chemical oxygen units must be replaced
and all masks restowed.
The system is reset by momentarily pressing the TMR
RESET pushbutton on the maintenance panel.
TMUOXYR01-T04 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page50
8
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYR01-P04 LEVEL 3
UEP4200

PASSENGER OXYGEN DESCRIPTION AND OPERATION - RESET OPERATION (A/C ON GROUND)

EFFECTIVITY
EFFECTIVITY Page
Page51
9
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN DESCRIPTION AND OPERATION

FAULT OPERATION

When the cabin altitude is more than 14000 FT and relay


8WR and 9WR remain open after delay:
- Relay 15WR is energized
- The Fault amber light comes on
- The SYS ON white light and Public Address
systems are still on
The FAULT light on the TMR RESET pushbutton comes on
if a failure of the TIME DELAY RELAYS occurs.
TMUOXYR01-T05 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 52
10
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYR01-P05 LEVEL 3
UEP4200

PASSENGER OXYGEN DESCRIPTION AND OPERATION - FAULT OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page 53
11
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

SELF EXAMINATION

How do the time delay relays control the pax system


automatic operation ?
A - They cut off electrical supply after 30
seconds.
B - They supply the system for 3 seconds.
C - They supply the system after 30 seconds.

The TMR RESET FAULT light comes on if:


A - The reset operation is not yet completed.
B - The reset operation has failed.
C - The time delay relays have failed during
the automatic operation.
TMUOXYR01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 54
12
ALL 35-21-00 Jul 31/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-20-00 PASSENGER OXYGEN UNIT OPERATION

CONTENTS:
Mask Operation
Chemical Oxygen Generation
Generator Operation
TMUOXYL01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page55
1
ALL 35-20-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN UNIT OPERATION

MASK OPERATION

As soon as the emergency oxygen container doors open,


the masks fall out.
They are hung on lanyards within the reach of users.
When the first user pulls the mask towards his face,
the release pin starts the chemical generation.
Oxygen flows through the flexible supply hose to the
mask.
The flow indicator shows a green stripe.
TMUOXYL01-T01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page56
2
ALL 35-20-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYL01-P01 LEVEL 3
UEP4200

PASSENGER OXYGEN UNIT OPERATION - MASK OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page57
3
ALL 35-20-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN UNIT OPERATION

CHEMICAL OXYGEN GENERATION

The chemical generator uses the basic principal of


thermal decomposition of sodium chlorate.
An indicator turning from yellow to black shows the
generator is expended.
The chlorate core is fitted in a stainless steel
housing.
A thermal insulating material is used between the core
and the housing.
A filter is installed in the outlet end of the housing.
TMUOXYL01-T02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page58
4
ALL 35-20-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYL01-P02 LEVEL 3
UEP4200

PASSENGER OXYGEN UNIT OPERATION - CHEMICAL OXYGEN GENERATION

EFFECTIVITY
EFFECTIVITY Page
Page59
5
ALL 35-20-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN UNIT OPERATION

GENERATOR OPERATION

The generator actuator consists of a spring-loaded


striker and a percussion fuse.
A relief valve fitted on the generator housing protects
the generator against high internal pressure.
TMUOXYL01-T03 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page60
6
ALL 35-20-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYL01-P03 LEVEL 3
UEP4200

PASSENGER OXYGEN UNIT OPERATION - GENERATOR OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page61
7
ALL 35-20-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYL01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page62
8
ALL 35-20-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-20-00 PASSENGER OXYGEN COMPONENTS

CONTENTS:
Altitude Pressure Switch
Chemical Emergency Oxygen Container
Door Stop
Continuous Flow Mask
TMUOXYK01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page63
1
ALL 35-20-00 Jul 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN COMPONENTS

ALTITUDE PRESSURE SWITCH

IDENTIFICATION
FIN: 16WR

LOCATION
ZONE: 127

COMPONENT DESCRIPTION
The altitude pressure switch closes when the cabin
pressure decreases to a pressure equivalent to 14.000
feet. This action operates the emergency oxygen system.
The pax oxygen system automatic control may be
inoperative provided that the aircraft altitude is
limited to 30.000 feet.
TMUOXYK01-T01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page64
2
ALL 35-20-00 Jul 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYK01-P01 LEVEL 3
UEP4200

PASSENGER OXYGEN COMPONENTS - ALTITUDE PRESSURE SWITCH

EFFECTIVITY
EFFECTIVITY Page
Page65
3
ALL 35-20-00 Jul 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN COMPONENTS

CHEMICAL EMERGENCY OXYGEN CONTAINER DOOR STOP

LOCATION LOCATION
ZONE: 200 ZONE: 200

COMPONENT DESCRIPTION COMPONENT DESCRITPION


Each oxygen container comprises: The door stop is installed in the emergency
- a container box, oxygen-container.
- a door fitted with a latch assembly, The door stop allows an inspection and a test of the
- a door stop, emergency oxygen-container door opening to be
performed. The door stop allows the door to open by a
- a chemical emergency oxygen container,
few degrees. To open the door manually, you can release
continuous flow oxygen masks with flexible supply
the electrical latch assembly with a manual release
hoses.
tool.
TMUOXYK01-T02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page66
4
ALL 35-20-00 Jul 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYK01-P02 LEVEL 3
UEP4200

PASSENGER OXYGEN COMPONENTS - OXYGEN UNIT

EFFECTIVITY
EFFECTIVITY Page
Page67
5
ALL 35-20-00 Jul 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN COMPONENTS

CONTINUOUS FLOW MASK

LOCATION
ZONE: 200

COMPONENT DESCRIPTION
When the first user pulls the mask towards his face,
the release pin starts the chemical oxygen generation.
Oxygen flows through the flexible hose to the mask.
The flow indicator inflates when the oxygen flows.
TMUOXYK01-T03 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page68
6
ALL 35-20-00 Jul 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYK01-P03 LEVEL 3
UEP4200

PASSENGER OXYGEN COMPONENTS - OXYGEN UNIT

EFFECTIVITY
EFFECTIVITY Page
Page69
7
ALL 35-20-00 Jul 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYK01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page70
8
ALL 35-20-00 Jul 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-23-00 PASSENGER OXYGEN SYSTEM


ELECTRICAL CIRCUIT

CONTENTS:
Manual Mask Releasing
Automatic Mask Releasing
Oxygen Unit Deactivation
Fault Light On
Reset Operation
TMUOXYM01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page71
1
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT

MANUAL MASK RELEASING

THE MASK MAN ON PUSHBUTTON IS PRESSED :


- the masks are released
- the SYS ON white light comes on
- Public Address is on
TMUOXYM01-T01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page72
2
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYM01-P01 LEVEL 3
UEP4200

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT - MANUAL MASK RELEASING

EFFECTIVITY
EFFECTIVITY Page
Page73
3
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT

Manual Mask Releasing

6 Seconds after system activation, relay 25WR is on


to interconnect the LH and RH latch assembly electrical
circuits.
This ensures that all oxygen unit electrical latches
remain energized if a circuit is damaged in the event
of engine turbine bursting.
TMUOXYM01-T02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page74
4
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYM01-P02 LEVEL 3
UEP4200

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT - MANUAL MASK RELEASING

EFFECTIVITY
EFFECTIVITY Page
Page75
5
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT

AUTOMATIC MASK RELEASING

CABIN ALTITUDE IS MORE THAN 14000 FT (16WR CLOSED) :


- the masks are released
- the SYS ON white light comes on
- Public Address is on
TMUOXYM01-T03 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page76
6
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYM01-P03 LEVEL 3
UEP4200

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT - AUTOMATIC MASK RELEASING

EFFECTIVITY
EFFECTIVITY Page
Page77
7
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT

AUTOMATIC MASK RELEASING

6 Seconds after system activation, relay 25WR is on


to interconnect the LH and RH latch assembly electrical
circuits.
This ensures that all oxygen units electrical latches
remain energized if a circuit is damaged in the event
of engine turbine bursting.
TMUOXYM01-T04 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page78
8
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYM01-P04 LEVEL 3
UEP4200

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT - AUTOMATIC MASK RELEASING

EFFECTIVITY
EFFECTIVITY Page
Page79
9
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT

OXYGEN UNIT DEACTIVATION

CABIN ALTITUDE IS MORE THAN 14000 FT (16WR CLOSED) :


- 30 Seconds after mask activation, the
oxygen unit door latches are deactivated.
SYS ON white light and Public Address
system will remain energized.
TMUOXYM01-T05 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 80
10
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYM01-P05 LEVEL 3
UEP4200

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT - OXYGEN UNIT DEACTIVATION

EFFECTIVITY
EFFECTIVITY Page
Page 81
11
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT

FAULT LIGHT ON

CABIN ALTITUDE IS MORE THAN 14000 FT AND RELAY 8WR AND


9WR REMAIN OPEN AFTER A TIME DELAY:
- Relay 15WR is energized
- The FAULT amber light comes on
- The SYS ON white light and Public Adress
system are still on
TMUOXYM01-T06 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 82
12
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYM01-P06 LEVEL 3
UEP4200

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT - FAULT LIGHT ON

EFFECTIVITY
EFFECTIVITY Page
Page 83
13
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT

RESET OPERATION

ON GROUND AND TMR RESET PUSHBUTTON IS PRESSED:


- Electrical supply to relays 8WR/9WR/19WR/6LP
is cut off
- ON white light comes on as long as the reset
pushbutton is pressed
- SYS ON white light and Public Address
system are off
TMUOXYM01-T07 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 84
14
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYM01-P07 LEVEL 3
UEP4200

PASSENGER OXYGEN SYSTEM ELECTRICAL CIRCUIT - RESET OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page 85
15
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYM01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page 86
16
ALL 35-23-00 Apr 30/00
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-31-00 CREW PORTABLE OXYGEN SYSTEM


DESCRIPTION AND OPERATION

CONTENTS:
General
Location
Description
Operation
Self Examination
TMUOXYQ02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page87
1
ALL 35-31-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW PORTABLE OXYGEN SYSTEM


DESCRIPTION AND OPERATION

GENERAL

The crew smoke hood system provides eyes protection


and supplies oxygen to the crew member in case of
emergency :fire, or an emission of smoke and/or noxious
gases.
The crew smoke hood system allows freedom of movement
to extinguish a fire. It can also be used as an
emergency-oxygen supply if the fixed emergency-oxygen
system does not work.

LOCATION

The smoke hood is vacuum packed in a transport/storage


container.
The crew smoke hoods are installed in the cockpit in
the first officer’s console (702VU).
Smoke hoods for cabin attendants are installed in the
cabin.
TMUOXYQ02-T01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page88
2
ALL 35-31-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYQ02-P01 LEVEL 3
UEP4200

CREW PORTABLE OXYGEN SYSTEM DESCRIPTION AND OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page89
3
ALL 35-31-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW PORTABLE OXYGEN SYSTEM


DESCRIPTION AND OPERATION

DESCRIPTION

The hood is fire resistant and has an autonomy of 15


minutes.
The container is provided with a good condition
indicator, normally green (red : hood unserviceable),
and a tamper seal used for the preflight inspection.
TMUOXYQ02-T02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page90
4
ALL 35-31-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYQ02-P02 LEVEL 3
UEP4200

CREW PORTABLE OXYGEN SYSTEM DESCRIPTION AND OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page91
5
ALL 35-31-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CREW PORTABLE OXYGEN SYSTEM


DESCRIPTION AND OPERATION

OPERATION

When doned, the automatic start lever connected to the


annular container, releases the compressed oxygen
stored inside the container.
Then, the oxygen fills up the compartment between the
external and the internal hood.
During inhalation, the oxygen flows to the inner
compartment through the absorption system.
During exhalation, the absorption system traps the
carbon dioxyde contained in the expired gas through a
layer of soda lime.
A pressure control valve prevents an increase of
pressure in the hood.
A phonic membrane allows the user to communicate
easily.
NOTE :
- A slight noise of oxygen flow is heard by
the wearer during operation.
When the noise of oxygen flow stops, the
hood should no longer be used.
TMUOXYQ02-T03 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page92
6
ALL 35-31-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYQ02-P03 LEVEL 3
UEP4200

CREW PORTABLE OXYGEN SYSTEM DESCRIPTION AND OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page93
7
ALL 35-31-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

SELF EXAMINATION

What is the function of the hood absorption


system ?
A - To add oxygen to the expired gas.
B - To trap the carbon dioxyde contained in
the expired gas.
C - To allow the expired gas to flow out of
the hood.
TMUOXYQ02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page94
8
ALL 35-31-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-32-00 CABIN PORTABLE OXYGEN EQUIPMENT


DESCRIPTION/OPERATION

CONTENTS:
Bottle
First Aid Mask
Smoke Hood System
TMUOXYP02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page95
1
ALL 35-32-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CABIN PORTABLE OXYGEN EQUIPMENT


DESCRIPTION/OPERATION

BOTTLE

The oxygen source is a high pressure cylinder with a


capacity of 310 liters (11 cubic feet).
The high pressure cylinders are installed in brackets
equipped with quick release clamps.
TMUOXYP02-T01 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page96
2
ALL 35-32-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYP02-P01 LEVEL 3
UEP4200

CABIN PORTABLE OXYGEN EQUIPMENT DESCRIPTION/OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page97
3
ALL 35-32-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CABIN PORTABLE OXYGEN EQUIPMENT


DESCRIPTION/OPERATION

FIRST AID MASK

The continuous-flow first aid oxygen mask provides


oxygen for therapeutic purposes.
The flexible supply hose connects the mask to the
calibrated continuous flow outlet of the bottle.
TMUOXYP02-T02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page
Page98
4
ALL 35-32-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYP02-P02 LEVEL 3
UEP4200

CABIN PORTABLE OXYGEN EQUIPMENT DESCRIPTION/OPERATION

EFFECTIVITY
EFFECTIVITY Page
Page99
5
ALL 35-32-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

CABIN PORTABLE OXYGEN EQUIPMENT


DESCRIPTION/OPERATION

SMOKE HOOD SYSTEM

The smoke hood system provides breathing means and


eyes protection for one user in case of emergency:
fire, or an emission of smoke and/or noxious gases.
It permits him to move freely.
The smoke hood container is provided with a
good-condition indicator and a tamper seal for the
pre-flight inspection.
The annular container in the hood, full of compressed
oxygen, releases the amount of oxygen that the user
needs.
The gas circulation is generated when the user breathes
in and out.
TMUOXYP02-T03 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page 100
Page 6
ALL 35-32-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYP02-P03 LEVEL 3
UEP4200

CABIN PORTABLE OXYGEN EQUIPMENT DESCRIPTION/OPERATION

EFFECTIVITY
EFFECTIVITY Page 101
Page 7
ALL 35-32-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYP02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page 102
Page 8
ALL 35-32-00 Dec 31/95
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

35 - OXYGEN

35-11-41 OXYGEN CYLINDER -


REMOVAL/INSTALLATION

CONTENTS:
Precautions
Removal
Installation
TMUOXYI02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page 103
Page 1
ALL 35-11-41 May 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

OXYGEN CYLINDER

PRECAUTIONS Loosen the nut and disconnect the pressure regulator


transmitter assembly from the oxygen cylinder.
WARNING : Put a blanking cap on the pressure regulator and put
KEEP ALL HYDROCARBONS (FUEL, LUBRICANTS, ETC...) AWAY it in a sealed vinyl bag.
FROM ALL SOURCE OF OXYGEN. OXYGEN BECOMES EXPLOSIVE Put an oxygen cylinder cap on the cylinder valve.
WHEN IT TOUCHES HYDROCARBONS. Disconnect the HP safety hose from the cylinder head ;
CLEAN THE TOOLS AND MAKE SURE YOUR HANDS ARE CLEAN TO discard the sleeve and put a blanking cap on the union.
PREVENT CONTAMINATION OF THE OXYGEN SYSTEM. Put an oxygen cylinder stowage cap on the cylinder
valve.
CAUTION : Loosen the nut and disengage the pin from the clamp
PUT DRY AND CLEAN, METAL OR PLASTIC PLUGS AN ALL PIPES to remove the cylinder from the support.
OR UNITS REMOVED TEMPORARILY.
PUT EACH PIPE OR UNIT IN A SEALED VINYL BAG.

REMOVAL

Put the access platform in position and open the access


door 812.
The oxygen cylinder has to be removed in case of low
content or leakage. Close the oxygen cylinder ON/OFF
valve.
Energize the aircraft electrical circuits ; make sure
that the avionics equipment ventilation operates
correctly.
Check that the OXYGEN/CREW/OXY/SPLY circuit-breaker
1 HT is closed.
Bleed and empty the oxygen system:
TMUOXYI02-T01 LEVEL 3

- press the OXYGEN/CREW SUPPLY pushbutton.


- On one of the oxygen masks, actuate the PRESS
TO TEST AND RESET slider several times to empty
the system.
UEP4200

- release the OXYGEN/CREW SUPPLY pushbutton.


- open, safety and tag the OXYGEN/CREW/OXY/SPLY
circuit breaker 1 HT.

EFFECTIVITY
EFFECTIVITY Page 104
Page 2
ALL 35-11-41 May 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYI02-P01 LEVEL 3
UEP4200

OXYGEN CYLINDER - REMOVAL

EFFECTIVITY
EFFECTIVITY Page 105
Page 3
ALL 35-11-41 May 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

OXYGEN CYLINDER

INSTALLATION Examine each connection to make sure that there are


no leaks.
Make sure that the aircraft is in the same Rub off the SPECIAL MATERIAL solution.
configuration as for the removal operation. Make sure that the work area is clean and clear of
Open and tag the circuit-breaker: tools and other items.
- OXYGEN/CREW/OXY/SPLY 1 HT Close the access door 812.
Make sure that the parts retained from the removed Remove the access platform.
component are clean and in the correct condition. De-energize the aircraft electrical circuits.
Check the expiration date on the cylinder to make sure Remove the safety clip and the tag.
it can still be used. Close the circuit-breaker 1 HT.

NOTE: No compound, except SPECIAL MATERIALS must be


used on nut threads or on the flared portion of
the tube. This compound should be used sparingly
on all first three male threads.
Carefully put the cylinder on the support.
Close the clamp and tighten the pin.
Remove the oxygen cylinder stowage cap from the
cylinder valve.
Remove the blanking cap from the HP safety connector.
Put a new sleeve on the union and tighten the HP safety
connector on the cylinder head.
Remove the blanking cap from the pressure regulator
transmitter assembly and the corresponding stowage cap
on the cylinder head.
Put the regulator on the valve and tighten the nut.
Apply the SPECIAL MATERIAL solution to the mechanical
TMUOXYI02-T02 LEVEL 3

connections.
Very slowly, open the valve of the cylinder 3. 5 to
4 turns.
Let the pressure become stable, this occurs after
UEP4200

approximately 90 seconds. Fully open the cylinder


valve.

EFFECTIVITY
EFFECTIVITY Page 106
Page 4
ALL 35-11-41 May 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN
TMUOXYI02-P02 LEVEL 3
UEP4200

OXYGEN CYLINDER - INSTALLATION

EFFECTIVITY
EFFECTIVITY Page 107
Page 5
ALL 35-11-41 May 31/96
_A319 TECHNICAL TRAINING MANUAL
MECHANICS / ELECTRICS & AVIONICS COURSE 35 OXYGEN

THIS PAGE INTENTIONALLY LEFT BLANK


TMUOXYI02 LEVEL 3
UEP4200

EFFECTIVITY
EFFECTIVITY Page 108
Page 6
ALL 35-11-41 May 31/96