Autotronic 5 - Dyna-6 - Error Codes: TR4: Theoretical Forward Speed Sensor

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Autotronic 5 - Dyna-6 - Error codes

TR4: Theoretical forward speed sensor

TR4
Description
Location: above the differential ring gear (Fig. 27)
Inductive sensor.

- Pin 1: Signal
- Pin 2: Earth
TR10
Signals:
Resistance when stopped: 450 Ohms +/- 20
Alternating voltage when the ring gear is rotating

To adjust the air gap:


MA-11-01577A
- Apply a small amount of Loctite 5922 to the Fig. 27
threads
- Fully screw in the sensor against the gear
- Unscrew the sensor by ¾ of a turn
- Tighten the counter-nut to approximately 6 Nm

2
2
1
1
MA-11-01265A
Possible error codes
Fig. 28

Reaction of the Reset the


Errors Descriptions Solutions
system system*
Check:
- Sensor status
- Sensor resistance of 450 Ohms,
No speed detected and as well as alternating voltage
Error code displayed
T1 15 current intermediate when gear is rotating No
only
speed > 0
- Contacts
- Harness connections
- Wiring
Difference in value Disengages all ranges Check:
between the interme- for 6 s (coasting) and - Connection logic for the 4 sole-
diate speed sensor and re-engages the range noid valves and their range sensor
T1 26 engaged before the - Speed sensors for correct Yes
forward speed sensor
depending on range error connection
engaged • Buzzer active
*To reset the system, move the PowerControl lever to neutral position and then press and release the clutch pedal

WINTEST - Issue 9.b GUF563.29