IC600 600mm Diameter Chambers Data Sheet

PRODUCT INFORMATION ISSUE 4 - APRIL 2021

The Polypipe IC600 range of 600mm diameter inspection


chambers is designed for adoptable and non-adoptable
domestic and commercial drainage systems, the range
is manufactured from high quality polypropylene and is
engineered to last.

The unique adaptor range simplifies choice allowing multiple


configuration options for connection to Polysewer, BS EN 1401
Smoothwall PVCu, 110mm & 150mm Ridgidrain and 100mm &
150mm Vitrified Clay pipe. IC6BS6

Key Benefits

• Choice of five IC600 bases with straight through flow or cross tee configuration
• For use with 150/160mm, 225/250mm or 300/315mm pipe
• Choice of adaptors for pipe connection to Polysewer, Smoothwall PVCu, Ridgidrain and Vitrified Clay pipe
• Certified to EN 13598-2 and compliant to Sewerage Sector Guidance for England, Sewers for Scotland and the Welsh Minis-
ter Standards for Sewers.
• Double skinned base for additional groundwater resistance
• Fully sealed for a water tight, tamper proof and low maintenance installation
• Light weight & strong for improved health and safety and easy handling, corrosion resistant
• High strength single piece 600mm diameter Ridgisewer SN8 riser
• Riser cap which can be adapted for reduced access for chamber depths of greater than 1.2m by using the UG514 restricted
access reducer with Polypipe ductile iron covers & frames or directly with the UG520 reduced access ductile iron cover and
frame.
• Riser cap directly compatible with the UG510 Polypropylene square cover and frame

Installation Instructions

• Excavations will need precautions against collapse; where deeper than 1.2m use side supports
• Insert relevant adaptor(s) into the base prior to installation in trench
• Install on a compacted granular bed 100mm deep placed on the trimmed trench bottom
• Place base on the granular bed in the correct orientation with swept inlets in direction of flow
• Note the through channel must be used, bends up to 45º can be used on any inlet or outlet
• Joint pipework using standard Polysewer or BS EN 1401 method
• Backfill under and around the base with granular material in layers not exceeding 150mm, ensuring the inside
of the base is free of debris
• Cut riser to size midway between the corrugations leaving at least 300mm extra to accommodate changes to
final levels. The riser requires a seal at the connection to the base and the riser cap
• Locate the riser ring seal between the first and second corrugations, lubricate the seal and offer to the socket,
aligned riser and push fully home. Fit riser cap to top of riser using a seal on the pipe
• Cover top of riser to prevent ingress of debris, backfill in compacted layers with selected site material free from
stones greater than 25mm or use imported granular material
IC600 600mm Diameter Chambers
PRODUCT RANGE

Chamber Bases for 150/160mm Pipe - Adaptors & Accessories

CHAMBER BASE

IC6BS6 IC6CRS6
600mm dia. base straight 600mm dia. base straight channel
channel and single inlet for and three inlets including 2
110/150/160mm BS EN 1401 x 90˚ equal branch inlets for
Underground pipes when used 110/150/160mm BS EN 1401
with appropriate adaptor Undergorund pipes when used
with appropriate adaptor

ADAPTORS

NEW

IC6PS6 IC6UG6 IC6AUG64 IC6EC6


IC600 150/160mm base adaptor IC600 150/160mm base IC600 150/160mm base IC600 150/160mm base end cap
to 150mm Polysewer pipe adaptor to 160mm BS EN 1401 adaptor to 110mm BS EN 1401 to seal unused inlets on IC6BS6
Underground pipe Underground pipe and IC6CRS6 bases

+ + + +

IC6AUG64 + UG459 IC6AUG64 + UG487 IC6UG6 + UG659 IC6UG6 + UG697


To connect 100mm thin-wall To connect 100mm thick-wall To connect 150mm thin-wall To connect 150mm thick-wall
clay (SuperSleve) pipe to IC600 clay (Densleeve) pipe to IC600 clay (SuperSleve) pipe to IC600 clay (Densleeve) pipe to IC600
150/160mm base use IC6AUG64 150/160mm base use IC6AUG64 150/160mm base use IC6UG6 + 150/160mm base use IC6UG6 +
+ UG459 + UG487 UG659 UG697

+ +

IC6AUG64 + ARD100110 IC6UG6 + ARD150160


To connect 110mm Ridgidrain pipe To connect 150mm Ridgidrain
to IC600 150/160mm base use pipe to IC600 150/160mm base
IC6AUG64 + ARD100110 use IC6UG6 + ARD150160
IC600 600mm Diameter Chambers
PRODUCT RANGE

Chamber Bases for 225/250mm Pipe - Adaptors & Accessories

CHAMBER BASE

IC6CRS10
600mm dia. base straight channel and three
inlets including 2 x 90˚ equal branch inlets for
110/150/160/225/250mm pipes when used with
appropriate adaptor

ADAPTORS

NEW

IC6APS106 IC6PS10 IC6UG10 IC6EC10


IC600 225/250mm base adaptor IC600 225/250mm base adaptor IC600 225/250mm base IC600 225/250mm base end
to 150mm Polysewer pipe to 225mm Polysewer pipe adaptor to 250mm BS EN 1401 cap to seal unused inlets on
Underground pipe IC6CRS10 base

NEW NEW

+ +

IC6AUG104 IC6AUG106 IC6AUG106 + UG659 IC6AUG106 + UG697


IC600 225/250mm base IC600 225/250mm base To connect 150mm thin-wall To connect 150mm thick-
adaptor to 110mm BS EN 1401 adaptor to 160mm BS EN 1401 clay (SuperSleve) pipe to IC600 wall clay (Densleeve) pipe to
Underground pipe Underground pipe 225/250mm base use IC6AUG106 IC600 225/250mm base use
+ UG659 IC6AUG106 + UG697
IC600 600mm Diameter Chambers
PRODUCT RANGE

Chamber Bases for 300/315mm Pipe - Adaptors & Accessories

CHAMBER BASE

IC6BS12 IC6CRS12
Straight channel for use with Straight channel and two equal
300mm Polysewer pipe (requires 90° branch entries, for use with
adaptor PS12102) or 315mm BS 300mm Polysewer pipe (requires
EN 1401 Sewerdrain pipe (direct adaptor PS12102), 315mm BS
connection) EN 1401 Sewerdrain pipe (direct
connection)

ADAPTORS

PS12102 UG1220
IC600 300/315 base adaptor to IC600 300/315 base
300mm Polysewer pipe 315mm End Cap/Socket Plug to
seal unused inlets on IC6BS12 or
IC6CRS12 base

ALL CHAMBER ACCESSORIES


IC600 Riser and Accessories

RSW600X3PE8 IC6RC SRSW6008


Riser shaft SN8 3m plain end for Riser cap (can be adapted for Riser Ring Seal (required for
IC600 base reduced access for chamber base to riser and cap to riser
depths of greater than 1.2m) connections)
IC600 600mm Diameter Chambers
TYPICAL INSTALLATION DETAIL (Subject to vehicle loading)

Ductile iron cover and frame B125


Kitemarked to BS EN 124 - Polypipe code
UG513 (square) or UDC750 (round).
Alternatively D400 (supplied by others)

Mortar bed and haunching Class B engineering Bricks or


to cover & frame. pre-cast concrete cover frame
seating rings

Granular type 1 sub-based Pre-cast concrete slab or in-situ


material concrete slab to support cover
and frame, minimum 700mm clear
opening
600mm diameter
riser Minimum 50mm gap between riser
and cover slab, filled with flexible
foam filler

Riser cap with restricted access


reducer UG514

Minimum 150mm thick granular


type 1 sub-base material or
GEN3 in-situ concrete surround

Granular bedding material

Base adaptor to smoothwall or


Polysewer pipe

160/250/315mm smoothwall
underground pipe or
150/225/300mm Polysewer

IC600 Base
IC600 600mm Diameter Chambers
Requirements for 600mm Chamber Bases

Chamber Bases to 160mm Drainage


Quantities shown are for base units only and are identical for units when handed. Riser, riser cap and covers etc., not shown.
1.1 110 1.2 110 1.3 160 1.4 160

110 110 110 110

160 160 160 160

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS6 Base Unit 1 IC6CRS6 Base Unit 1 IC6BS6 Base Unit 1 IC6CRS6 Base Unit 1
IC6UG6 160 Base Adaptor 1 IC6UG6 160 Base Adaptor 1 IC6UG6 160 Base Adaptor 2 IC6UG6 160 Base Adaptor 2
IC6AUG64 110 Base Adaptor 2 IC6AUG64 110 Base Adaptor 3 SRSW6008 Base Seal 1 IC6AUG64 110 Base Adaptor 1
IC6EC6 Base End Cap 1 SRSW6008 Base Seal 1 IC6EC6 Base End Cap 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1
1.5 1.6 1.7 1.8
160 160 160 160

160 110 110 110 160 160 160

160 160 160 160

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS6 Base Unit 1 IC6CRS6 Base Unit 1 IC6CRS6 Base Unit 1 IC6CRS6 Base Unit 1
IC6UG6 160 Base Adaptor 3 IC6UG6 160 Base Adaptor 2 IC6UG6 160 Base Adaptor 3 IC6UG6 160 Base Adaptor 4
IC6EC6 Base End Cap 1 IC6AUG64 110 Base Adaptor 2 IC6AUG64 110 Base Adaptor 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

Chamber Bases to 150mm Polysewer


Quantities shown are for base units only and are identical for units when handed. Riser, riser cap and covers etc., not shown.

2.1 110 2.2 110 2.3 150 2.4 150

110 110 110 110

150 150 150 150

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS6 Base Unit 1 IC6CRS6 Base Unit 1 IC6BS6 Base Unit 1 IC6CRS6 Base Unit 1
IC6PS6 150 Base Adaptor 1 IC6PS6 150 Base Adaptor 1 IC6PS6 150 Base Adaptor 2 IC6PS6 150 Base Adaptor 2
IC6AUG64 110 Base Adaptor 2 IC6AUG64 110 Base Adaptor 3 SRSW6008 Base Seal 1 IC6AUG64 110 Base Adaptor 1
IC6EC6 Base End Cap 1 SRSW6008 Base Seal 1 IC6EC6 Base End Cap 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

2.5 2.6 2.7 2.8


150 150 150 150

150 110 110 110 150 150 150

150 150 150 150

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS6 Base Unit 1 IC6CRS6 Base Unit 1 IC6CRS6 Base Unit 1 IC6CRS6 Base Unit 1
IC6PS6 150 Base Adaptor 3 IC6PS6 150 Base Adaptor 2 IC6PS6 150 Base Adaptor 3 IC6PS6 150 Base Adaptor 4
IC6EC6 Base End Cap 1 IC6AUG64 110 Base Adaptor 2 IC6AUG64 110 Base Adaptor 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

}
For Super Clay (Supersleve) use UG459 (100mm) or UG659 (150mm)
Adaptors:- For Thick Clay (Densleeve) use UG487 (100mm) or UG697 (150mm) into 110mm or 160mm base conn.
For Ridgidrain use ARD100110 (100mm) or ARD150160 (150mm)
IC600 600mm Diameter Chambers
Requirements for 600mm Chamber Bases

Chamber Bases to 225mm Polysewer


Quantities shown are for base units only and are identical for units when handed. Riser, riser cap and covers etc., not shown.
3.1 150 3.2 160 3.3 150 3.4 160

110 110 150 160

225 225 225 225

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6PS10 225 Base Adaptor 1 IC6PS10 225 Base Adaptor 1 IC6PS10 225 Base Adaptor 1 IC6PS10 225 Base Adaptor 1
IC6APS106 150 Base Adaptor 1 IC6AUG106 160 Base Adaptor 1 IC6APS106 150 Base Adaptor 2 IC6AUG106 160 Base Adaptor 2
IC6AUG104 110 Base Adaptor 1 IC6AUG104 110 Base Adaptor 1 IC6EC10 Base End Cap 1 IC6EC10 Base End Cap 1
IC6EC10 Base End Cap 1 IC6EC10 Base End Cap 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

3.5 150 3.6 160 3.7 150 3.8 160

110 110 110 110 110 150 110 160

225 225 225 225

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6PS10 225 Base Adaptor 1 IC6PS10 225 Base Adaptor 1 IC6PS10 225 Base Adaptor 1 IC6PS10 225 Base Adaptor 1
IC6APS106 150 Base Adaptor 1 IC6AUG106 160 Base Adaptor 1 IC6APS106 150 Base Adaptor 2 IC6AUG106 160 Base Adaptor 2
IC6AUG104 150 Base Adaptor 2 IC6AUG104 110 Base Adaptor 2 IC6AUG104 110 Base Adaptor 1 IC6AUG104 110 Base Adaptor 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

3.9 150 3.10 160

150 150 160 160

225 225

Code Description No. req. Code Description No. req.


IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6PS10 225 Base Adaptor 1 IC6PS10 225 Base Adaptor 1
IC6APS106 150 Base Adaptor 3 IC6AUG106 160 Base Adaptor 3
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

}
For Super Clay (Supersleve) use UG459 (100mm) or UG659 (150mm)
Adaptors:- For Thick Clay (Densleeve) use UG487 (100mm) or UG697 (150mm) into 110mm or 160mm base conn.
For Ridgidrain use ARD100110 (100mm) or ARD150160 (150mm)
IC600 600mm Diameter Chambers
Requirements for 600mm Chamber Bases

Chamber Bases to 225mm Polysewer


Quantities shown are for base units only and are identical for units when handed. Riser, riser cap and covers etc., not shown.

3.11 225 3.12 225 3.13 225 3.14 225

110 150 160

225 225 225 225

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6BS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6PS10 225 Base Adaptor 2 IC6PS10 225 Base Adaptor 2 IC6PS10 225 Base Adaptor 2 IC6PS10 225 Base Adaptor 2
SRSW6008 Base Seal 1 IC6AUG104 110 Base Adaptor 1 IC6APS106 150 Base Adaptor 1 IC6AUG106 160 Base Adaptor 1
IC6EC10 Base End Cap 1 IC6EC10 Base End Cap 1 IC6EC10 Base End Cap 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal . 1

3.15 3.16 3.17 3.18


225 225 225 225

225 110 110 110 150 110 160

225 225 225 225

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6PS10 225 Base Adaptor 3 IC6PS10 225 Base Adaptor 2 IC6PS10 225 Base Adaptor 2 IC6PS10 225 Base Adaptor 2
IC6EC10 Base End Cap 1 IC6AUG104 110 Base Adaptor 2 IC6APS106 150 Base Adaptor 1 IC6AUG106 160 Base Adaptor 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 IC6AUG104 110 Base Adaptor 1 IC6AUG104 110 Base Adaptor 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

3.19 3.20 3.21 3.22

225 225 225 225

110 225 150 150 150 225 160 160

225 225 225 225

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6PS10 225 Base Adaptor 3 IC6PS10 225 Base Adaptor 2 IC6PS10 225 Base Adaptor 3 IC6PS10 225 Base Adaptor 2
IC6AUG104 110 Base Adaptor 1 IC6APS106 150 Base Adaptor 2 IC6APS106 150 Base Adaptor 1 IC6AUG106 160 Base Adaptor 2
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

3.23 3.24

225 225

160 225 225 225

225 225

Code Description No. req. Code Description No. req.


IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6PS10 225 Base Adaptor 3 IC6PS10 225 Base Adaptor 4
IC6AUG106 160 Base Adaptor 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1

}
For Super Clay (Supersleve) use UG459 (100mm) or UG659 (150mm)
Adaptors:- For Thick Clay (Densleeve) use UG487 (100mm) or UG697 (150mm) into 110mm or 160mm base conn.
For Ridgidrain use ARD100110 (100mm) or ARD150160 (150mm)
IC600 600mm Diameter Chambers
Requirements for 600mm Chamber Bases

Chamber Bases to 300mm Polysewer


Quantities shown are for base units only and are identical for units when handed. Riser, riser cap and covers etc., not shown.
4.1 300 4.2 300 4.3 300 4.4 300

110 150 160

300 300 300 300

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6BS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1
PS12102 300 Base Adaptor 2 PS12102 300 Base Adaptor 2 PS12102 300 Base Adaptor 3 PS12102 300 Base Adaptor 2
SRSW6008 Base Seal 1 UG1221 315 x 250 Red. 1 PS1221 300 x 225 Red. 1 UG1221 315 x 250 Red. 1
UG1021 250 x 200 Red. 1 PS1021 225 x 150 Red. 1 UG1021 250 x 200 Red. 1
UG821 200 x 160 Red. 1 UG1220 315 Socket Plug 1 UG821 200 x 160 Red. 1
UG621 160 X 110 Red. 1 SRSW6008 Base Seal 1 UG1220 315 Socket Plug 1
UG1220 315 Socket Plug 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1
4.5 300 4.6 300 4.7 300 4.8 300

225 300 110 110 110 150

300 300 300 300

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1
PS12102 300 Base Adaptor 3 PS12102 300 Base Adaptor 3 PS12102 300 Base Adaptor 2 PS12102 300 Base Adaptor 3
PS1221 300 x 225 Red. 1 UG1220 315 Socket Plug 1 UG1221 315 x 250 Red. 2 PS1221 300 x 225 Red. 1
UG1220 315 Socket Plug 1 SRSW6008 Base Seal 1 UG1021 250 x 200 Red. 2 PS1021 225 x 150 Red. 1
SRSW6008 Base Seal 1 UG821 200 x 160 Red. 2 UG1221 315 x 250 Red. 1
UG621 160 x 110 Red. 2 UG1021 250 x 200 Red. 1
SRSW6008 Base Seal 1 UG821 200 x 160 Red. 1
UG621 160 x 110 Red. 1
SRSW6008 Base Seal 1

4.9 300 4.10 300 4.11 300 4.12 300

110 160 110 225 110 300 150 150

300 300 300 300

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1
PS12102 300 Base Adaptor 2 PS12102 300 Base Adaptor 3 PS12102 300 Base Adaptor 3 PS12102 300 Base Adaptor 4
UG1221 315 x 250 Red. 2 PS1221 300 x 225 Red. 1 UG1221 315 x 250 Red. 1 PS1221 300 x 225 Red. 2
UG1021 250 x 200 Red. 2 UG1221 315 x 250 Red. 1 UG1021 250 x 200 Red. 1 PS1021 225 x 150 Red. 2
UG821 200 x 160 Red. 2 UG1021 250 x 200 Red. 1 UG821 200 x 160 Red. 1 SRSW6008 Base Seal 1
UG621 160 x 110 Red. 1 UG821 200 x 160 Red. 1 UG621 160 x 110 Red. 1
SRSW6008 Base Seal 1 UG621 160 x 110 Red. 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1
4.13 300 4.14 300 4.15 300 4.16 300

150 225 150 300 225 225 225 300

300 300 300 300

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1
PS12102 300 Base Adaptor 4 PS12102 300 Base Adaptor 4 PS12102 300 Base Adaptor 4 PS12102 300 Base Adaptor 4
PS1221 300 x 225 Red. 2 PS1221 300 x 225 Red. 1 PS1221 300 x 225 Red. 2 PS1221 300 x 225 Red. 1
PS1021 225 x 150 Red. 1 PS1021 225 x 150 Red. 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

4.17 300

Adaptors:-
300 300

}
300 For Super Clay (Supersleve) use UG459 (100mm) or UG659 (150mm) into 110mm or
Code Description No. req.
For Thick Clay (Densleeve) use UG487 (100mm) or UG697 (150mm) 160mm base conn.
IC6CRS12 Base Unit 1 For Ridgidrain use ARD100110 (100mm) or ARD150160 (150mm)
PS12102 300 Base Adaptor 4
SRSW6008 Base Seal 1
IC600 600mm Diameter Chambers
Requirements for 600mm Chamber Bases

Chamber Bases to 250mm Sewerdrain


Quantities shown are for base units only and are identical for units when handed. Riser, riser cap and covers etc., not shown.
5.1 250 5.2 250 5.3 250 5.4 250

110 160 250

250 250 250 250

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6BS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6UG10 250 Base Adaptor 2 IC6UG10 250 Base Adaptor 2 IC6UG10 250 Base Adaptor 2 IC6UG10 250 Base Adaptor 3
SRSW6008 Base Seal 1 IC6AUG104 110 Base Adaptor 1 IC6AUG106 160 Base Adaptor 1 IC6EC10 Base End Cap 1
IC6EC10 Base End Cap 1 IC6EC10 Base End Cap 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

5.5 250 5.6 250 5.7 250 5.8 250

110 110 110 160 110 250 160 160

250 250 250 250

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6UG10 250 Base Adaptor 2 IC6UG10 250 Base Adaptor 2 IC6UG10 250 Base Adaptor 3 IC6UG10 250 Base Adaptor 2
IC6AUG104 110 Base Adaptor 2 IC6AUG106 160 Base Adaptor 1 IC6AUG104 110 Base Adaptor 1 IC6AUG106 160 Base Adaptor 2
SRSW6008 Base Seal 1 IC6AUG104 110 Base Adaptor 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1

5.9 5.10
250 250

160 250 250 250

250 250

Code Description No. req. Code Description No. req.


IC6CRS10 Base Unit 1 IC6CRS10 Base Unit 1
IC6UG10 250 Base Adaptor 3 IC6UG10 250 Base Adaptor 4
IC6AUG106 160 Base Adaptor 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1

}
For Super Clay (Supersleve) use UG459 (100mm) or UG659 (150mm)
Adaptors:- For Thick Clay (Densleeve) use UG487 (100mm) or UG697 (150mm) into 110mm or 160mm base conn.
For Ridgidrain use ARD100110 (100mm) or ARD150160 (150mm)
IC600 600mm Diameter Chambers
Requirements for 600mm Chamber Bases

Chamber Bases to 315mm Sewerdrain


Quantities shown are for base units only and are identical for units when handed. Riser, riser cap and covers etc., not shown.
6.1 315 6.2 315 6.3 315 6.4 315

110 160 250

315 315 315 315

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6BS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1
SRSW6008 Base Seal 1 UG1221 315 x 250 Red. 1 UG1221 315 x 250 Red. 1 UG1221 315 x 250 Red. 1
UG1021 250 x 200 Red. 1 UG1021 250 x 200 Red. 1 UG1220 315 Socket Plug 1
UG821 200 x 160 Red. 1 UG821 200 x 160 Red. 1 SRSW6008 Base Seal 1
UG621 160 x 110 Red. 1 UG1220 315 Socket Plug 1
UG1220 315 Socket Plug 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1

6.5 315 6.6 315 6.7 315 6.8 315

315 110 110 110 160 110 250

315 315 315 315

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1
UG1220 315 Socket Plug 1 UG1221 315 x 250 Red. 2 UG1221 315 x 250 Red. 2 UG1221 315 x 250 Red. 2
SRSW6008 Base Seal 1 UG1021 250 x 200 Red. 2 UG1021 250 x 200 Red. 2 UG1021 250 x 200 Red. 1
UG821 200 x 160 Red. 2 UG821 200 x 160 Red. 2 UG821 200 x 160 Red. 1
UG621 160 x 110 Red. 2 UG621 160 x 110 Red. 1 UG621 160 x 110 Red. 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

6.9 315 6.10 315 6.11 315 6.12 315

110 315 160 160 160 250 160 315

315 315 315 315

Code Description No. req. Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1
UG1221 315 x 250 Red. 1 UG1221 315 x 250 Red. 2 UG1221 315 x 250 Red. 2 UG1221 315 x 250 Red. 1
UG1021 250 x 200 Red. 1 UG1021 250 x 200 Red. 2 UG1021 250 x 200 Red. 1 UG1021 250 x 200 Red. 1
UG821 200 x 160 Red. 1 UG821 200 x 160 Red. 2 UG821 200 x 160 Red. 1 UG821 200 x 160 Red. 1
UG621 160 x 110 Red. 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1

6.13 315 6.14 315 6.15 315

250 250 250 315 315 315

315 315 315

Code Description No. req. Code Description No. req. Code Description No. req.
IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1 IC6CRS12 Base Unit 1
UG1221 315 x 250 Red. 2 UG1221 315 x 250 Red. 1 SRSW6008 Base Seal 1
SRSW6008 Base Seal 1 SRSW6008 Base Seal 1

}
For Super Clay (Supersleve) use UG459 (100mm) or UG659 (150mm)
Adaptors:- For Thick Clay (Densleeve) use UG487 (100mm) or UG697 (150mm) into 110mm or 160mm base conn.
For Ridgidrain use ARD100110 (100mm) or ARD150160 (150mm)

You might also like