Unit No.

NP-38

NITROGEN PUMP UNIT

Offshore
Eexde IIA T3 Sone 2 ATEX
80 dBa
Frame, slings & shackles in acc. to DNV 2.7-1
BS EN 12079

Dimension : L 5000 mm W 2438 mm H 2570 mm


Weight : 14900 kg
Lifting/Transport : Built-in frame with forklift pockets and lifting.
Ref. cert./Ser. no. frame : 15014001/NP-38

Volume diesel tank : 500 l


Q max. : 3000 SCF/M (180,000 SCF/H)
P max. : 690 bar
Connection in : 2 ea. Acme 150
Connection out : 2" Weco Fig. 1502 male / 1” NPTF
Recom. back up fuse : 16 A
Voltage range : 230 V 1 phase 50/60 Hz 1 phase (Fire/Gas central)

Triplex pump : Hydrarig NP200 1,3" x 1,625"


Boost pump : Hydrarig 1,5 x 2,5 x 6
Cold-ends : Hydrarig 1,625"
Vaporizer : Hydrarig Pot SN.9925
Motor m/3GP system : John Deere 6135 SFM75, 558 HK, max 1800 rpm Ser.no RG6135G002760
IIA T3 Sone II ATEX
Filter LIN suction side : Washable strainer
Fire/Gas central : 24V DC JCE EEx d IIB T6
Air/Diesel supply shut down if : - Over racing of motor.
- High temperature on exhaust.
- High temperature on cooling liquid.
- Low oil pressure on motor.
- Low air pressure.
- Fire alarm.
- Shutdown and alarm at 10% LEL gas (CH4)
- Emergency shut-down.
- Emergency shut-down from control room.
- Overpressure nitrogen.
Signal to platform if : Fire alarm, gas alarm, fault on gas/fire detectors
Other information : Swordsman foam deluge, OPS connection.
Diesel consumption at full effect : Approx. 72 l/hour
Built : 2014

IKM Testing AS, Ljosheimvegen 14, 4051 Sola, Norway ● +47 51 64 90 00 ●  IKMtesting@IKM.no ● www.IKM.no