1 Summary of reinforcement
The top plate design reinforcement with formwork plate is calculated in chapter Error: Reference
source not found.
1m 32-200c/c
20-200c/c
2m 32-200c/c + 20-200c/c
20-200c/c
2m 32-200c/c
Outer Vertical Reinforcement layer
20-200c/c
32-200c/c
32-200c/c
1m 1m
20-200c/c
32-200c/c
20-200c/c
(mm /m)2
(mm2/m) %
Ø32-200C/C at
Transverse- 3500 at wall support location,
Min Ast. 1570 4020 87%
Top support Ø20-200C/C
Top plate middle
Longitudinal
Min Ast. 1570 1650 2455 Ø25-200C/C 67%
- Top
2Ø25-200C/C
5030 Wall
Horizontal - bottom 2m, Ø20-
1500 1570 Bottom upto 4910 95%
(outer) 200C/C rest
2m
location
2Ø25-200C/C
3980 Wall
Horizontal- bottom 2m, Ø20-
1500 1570 Bottom upto 4910 92%
Walls (Inner) 200C/C rest
2m
location
Ø32-200C/C at
Vertical - 3790 Wall
1400 1570 4020 Top, Ø20-200C/C 94%
(outer) Top upto 2m
middle
Vertical -
1610 2455 - - Ø25-200C/C 65%
(Inner)
Longitudinal-
Min Ast 1570 - - Ø20-200C/C Min Ast
Top
Longitudinal-
Min Ast 1570 - - Ø20-200C/C Min Ast
Foundation Bottom
Slab Transverse -
Min Ast 1005 - - Ø16-200C/C Min Ast
Top
Transverse -
1020 1570 - - Ø20-200C/C 65%