LTR No.274 Water Report

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

/

vr{}q qlqlftro"I rTTe,il-{. g-c{rgnerus


NATIONAL INSTITUTE OF TECHNOLOCY, LITTARAKHANT)

Ref. No. : NITUt(CE/ztt tqgL oatef


$ lltrR z02l

To,
Mr. Satyajeet Khanduri
Project Manager, PMC/ARDANUY lNDl PVT LTD.
RVNL - Srikot Garhwal Uttarakhand-246174

Subject: - Regarding Testing of River Water

Letter Reference: Al/P1 379/Pl(PMC/SR/RVNU274

Sir,

With reference to your letter for Testing of River Water, tests were carried out and I am glad to hereby enclose
the test result for your received samples,

You may communicate with Dr. Aditya Kumar Anupam, (HoD Civil) at mobile No. +918909702825 and e-mail id
hod_civil @ nituk. ac. in for f urther coordination, please,

With regards,

-funq.t,
Dean (Research and Consultancy)

Copy to:

1 . M/s Rahee lnfratech Limited, Camp Off ice Lachmoli, Tehri Garhwal Uttarakhand Pin - 249161
2. HOD (Civil), NIT Uttarakhand
3. Assistance Registrar (Admin), NIT Uttarakhand
4. PA to Director, NIT Uttarakhand
5. PA to Registrar, NIT Uttarakhand
6, Office to Dean (R&C)
7. Guard File for record
vrodlq qlqlflrdt rrrre,TFT. srd-{Trc[us
NATIONAL INSTITUTE OF TECHNOLOGY, UTTARAKHANI)
Department of Civil Engineering
Date:2410312021
Report
Name of work: Water quality test

Letter Ref. t AllPl3T 9lPKlPMC/SR/RVNU27 4

Name of Client: Rail Vikas Nigam Limited

PMCr Ardanuy lndia Pvt. Ltd.

Test Result

Results
st. Permissible limit as
No
Parameters
per lS 456: 2000 Sample I Sample 2
(River Janasu) (Lachmoli side)
1 pH >6 7.2 7.5
2 Alkalinitv (mdL) 30 100
5 Aciditv (me/L) 5 15
4 Sulphate (me/L) 400 me/L 15 50
2000 mg/L for PCC
5 Chlorides (mg/L) 10 90
500 me/L for RCC
6 Total solids (me/L) 2000 me/L 600 1000
7 Organic matter (mg/L) 200 ms/L n 10

Remarks: All the above test results are valid only for received water samples from the client.

q"l '
. Laiju A R)
PI

Page 1 of 1