A) Remarks:
1) All bidders should submit a complete set of proposed fixtures (23 f ixture types), as we found different
numbers of submitted fixtures (19, 18, 15 ...).
2) Submit full compliance statement (signed and stamped by supplier and contractor) to specifications S12027-
0100D-FD-RR-SPC-EL-01 REV 0 sections 265100 & 265600. Note that some clauses were found missing, please
amend.
Response: Done, please refer to attached signed and stamped compliance sheet.
3) All bidders should complete the comparison table of compliance for all the specified 23 types. (Copy
attached for easy reference).
Response: Done, please refer to attached comparison table.
4) All bidders should provide an item for extra material and spare parts with proposed list of material.
Response: Extra materials will add to P.O quantity, on contractor account.
5) All bidders should include all components/parts in their offer without exclusions. Example: poles and high
masts should be included within their relevant types of design lighting fixture, complete with accessories.
Response: Noted.
6) All bidders should follow the attached list of comments/requirements and resubmit.
Response: Noted.
1) Submit Lighting calculations to prove that the design values (mentioned in drawing S12027-0100D-FD-RR-
EG-0001 and as per specifications) are achieved using the proposed f ixtures/material. Moreover, use well-
known software for calculations.
Response: Lighting calculation attached for your kind comments and approval.
2) Submit full compliance statement (signed and stamped by supplier and contractor) to specifications
S12027-
0100D-FD-RR-SPC-EL-01 REV 0 sections 265100 & 265600. Note that some clauses were found missing,
please amend.
Response: Done, please refer to attached signed and stamped compliance sheet.
Page 1 of7
SLCo
<i,pq.g_wjl JU)JI
Saudi Lighting
3) In the compliance statement; all items responded by "out of scope", "by others" or "not submitted" should
be complied by the Main contractor.
Response: To be confirmed by SBG.
4) All installation, supporting and fixation methods of poles, high masts and fixtures must be submitted with
calculations to structural engineer for review and approval.
Response : For lighting f ixtures please refer to attached technical submittal, for poles and high mast
to be submitted separately upon we finish the design and calculation according to project
requirements.
S) Project cond itions must be considered and the submitted material shall operate successfully within these
conditions; ambient temperature is SO degrees centigrade and can reach 70 in direct sunlight, relative
Humidity 100%, wind speed 160km/ hr. for poles and masts, seismic zone 2A, etc. as stipulated in
specifications section 26S600 clause l.S.c.
Response: Comply, for SO deg. C, Humidity 100% & wind speed 160km/hr.
For 70 deg. ambient temperature for maintenance purpose only not fo r 100% operating time.
For seismic zone 2A, not applicable for lighting fixtures.
6) Lighting fixtures with poles/high masts should follow the requirements of and be approved by the concerned
Municipality/Authorities.
Response: Comply, all submitted fixtures, poles & high mast are app roved and comply with MOMRA &
MOT standards.
7) Submit catalog cut with highlighted selection and third-party test certificates for all components (fixtures,
ballasts, lamps, ignitors, capacitors, SPDs, protective CBs /Fuses, Poles, masts etc ....).
Response: Done, please refer to attached technical submittal for all components included fixture
ballast, lamps, ignitor & capacitor. Note that SPDs and protective CBs N/A for lighting fixtures, to be
used on panels I power so urce . For poles and high mast to be submitted separately upon we finish
the design and calculation according to project requirements.
8) Fully equipped sample of each lighting fixture type, together with color and texture samples of each fixture
shall be submitted prior any delivery to site, to check t he internal installations/ finishes for approval by all
conce rned parties.
Response: Comply, Samples to be submitted after technical submittal approval, color will be as per SLC
standard color.
9) Finishes and paints type should comply with the specs or supplier shall get the approval of all concerned
parties for otherwise.
Response: Comply with variation, color and paint to be confirmed by consultants.
10) High mast should be eq uipped with two red air craft warning lights not one .
- Response: Will be submitted with poles response.
Page 2 of7
SLC
ci,!J~I OJUJJI
Saudi Lighting
11) All Glass lenses are to be shock resistant, moreover, please indicate clearly the IK of each fixture.
Response: Noted, please refer to attached technical submittal.
12) Confirm that fixtures and all components are suitable for the project supply 400/230V, 60Hz.
Response: Comply, all submitted lighting fixtures are suitable for project supply 400/230v, 60Hz.
Please refer to attached technical data sheet for control gear attached with each type in technical
submittal.
13) Submit with supporting documents that your proposed lamps will not exceed Maximum specific effective
radiant UV power of the lamp mW/klm to IEC 61167, especially metal halide lamps.
Response: Comply; please find attached technical data for MH lamps.
14) Confirm with supporting documents that compensation capacitors are Type (B) hermetically sealed as per
IEC 61048 (for high discharge lamps).
Response : Standard capacitor type A to be used as per attached data sheet along with technical submittal,
due to the class B capacitor is very special and not available as standard on capacitor manufacturer product
line with very long delivery time 16 - 18 weeks And the required capacitor is special and we did not use it
before in our product. Capacitor type A has been approved previously by DAR Cairo for Ajyad Plant at
Makkah - Has been implemented by SBG. Submittal reference # MAS-MA-EL-LI-039 Rev.04, please see
attached.
15) All light fittings shall be provided with an earthing terminal which shall be connected to the earth continuity
lead of the final sub-circuit.
Response: Comply.
16) Stick to technical Specs for minimum size of internal wiring. Moreover terminal block required to allow
connecting up to 6mm2.
Response:
a) For internal lighting referring to interior general specification # 265100- Part 2- Section 2.2- Point# N : we
comply that the internal Wiring Inside Fixtures: Not less than 0.5 mm2. Terminal block allow connecting up to
4mm2.
b) For exterior lighting the internal wiring for street and tunnel light will be l.Omm2 and for flood light as
mentioned exterior general specification # 2656QO- Part 2 - Section 2.4 - Point# E : the required internal
wiring is 2.5, where we will use 1.5mm2 . Terminal block allow connecting up to 4mm2.
17) Control gear is to be plug in type for operation at 230 V, a.c. single phase, 60 Hz. Ballast is to be specially
selected for particular type of lamps used, and lamps are to be able to start with at least +/-10% variation of
nominal voltage and continue in normal operation with dips attaining 20% for four seconds. Control gear
losses are not to exceed 10% of normal lamp wattage . RFI suppression device is to be provided. Power
factor is to be compensated to at least 0.9 lagging.
Response : Comply, for RFI comply for interior lighting fixtures where the RFI is integrated with ballast,
for exterior lighting fixtures RFI suppression device N/A.
Page 3 of7
SLCo
ci,!J Q..Q....Ul..JI JUPI
Saudi Lighting
18) Ballast and control-gear are to be mounted in lumina ire in separate compartment isolated from lamp, and
with encloterminal blocks fitted with quick-disconnect electrical leads. Where required, control gear is to be
contained in the pre-wired box, having an enclosure of IP 65, and mounted on luminaire ring separately from
luminaires.
Response: Comp ly.
19) Cables for internal wiring in control gear compartments are to be single core 2.5 mm2 copper conductors
with high temperature insulation and sheath .
Response: with reference to Exterior Lighting General Spes. # 265600 PART 2- PRODUCTS- Section 2.4
Floodlight, we comply that the internal wiring for floodlight is 2.5mm2 .
20) Provide class Ill SPD for all luminaires installed in high masts, street lighting poles .... Etc.
Response: NlA for lighting fixtures, to be used on panels I power source and I or with circuits included
sensitive devices. For poles and high mast it will be installed on ground directly, no need for SPD.
21) Control gears should include end-of-life protection as per IEC 60662, IEC 62035.
Response: All submitted control gear for MH and HPS comply IECIEN 60662 or the equivalent IECIEN
60188.
All submitted MH and HPS control gear with CE mark to comply with the safety standard IECIEN 62035.
22) For the high importance of the project; provide hot restrike ballasts for all street lighting fixtures.
Response: Not applicable with street light, due to hot restrike ballast required a double ended lamp
which is not possible with street light luminaries.
23) All f ixtures equipped with magnetic ballast are to be provided w ith electronic type ignitor and capacitor.
Response: Comply, please refer to attached ignitor and capacitor data sheet in submitted technical
submitt al along w ith each type of lighting fixtures.
24) HRC fuse cartridges shall be provided and suitably rated conforming to IEC 60269 or BS 88, complete with
base, for protection of t he luminai re. Fuse is to be rated to withstand starting current and is to be preferably
located in control gea r enclosure. Assure accessibility of the fuse cartridge for future maintenance.
Response: Suitable fuse will be used to protect the luminare with easy acceptability for future
maintenance; samples will be submitted for final approval.
25) Provide earthing rod, earthing pit, earth and neutral bars , wiring chambers , ... etc. and connections for all high
masts as shown in drawings and as mentioned is specs .Also provide earthing rod and pit connected to
lighting poles and circuits where shown in the drawings.
Response: Ppoles and high mast to be submitted separately upon we finish the design and
calculation according to project requirements.
Page 4 of 7
SLC
d.,JJq.g...m.JI OJU)JI
Saudi Lighting
26} Contractor is requested to furnish extra materials and spare parts as per specs and contract conditions.
Response: to be coordinate with contractor.
27} THO is not to exceed 10 %as per specification, moreover Provide supporting documents indicating the
values of 3rd, 5th, 7th & 9th Harmonics.
Response: Comply for HF electronic ballast, please refer to attached data sheet in technical submittal ..
29) Dimensions of the lighting fixtures are to be the same as the specified fixtures.
Response: Comply; please refer to attached technical submittal, samples to be submitted for approval.
32} Straight Tubular Fluorescent Lamps-Type TLS to be with CRI greater than 80 and CT=4000.
Response: Comply.
33} The terminal block of each fixture is required to allow connecting up to 4mm2 and to be sufficient for loop
in-loop out wiring, please coord inate with site engineer and submit final sample for approval before delivery
of material to site .
Response:
a) Loop in Loop out: For fluore scent lighting fixture Comply with variation, for street and tunnel light
N/A. Samples to be submitted for approval.
b) For terminal block of each f ixture is required to allow connecting up to 4mm2, comply for all types.
34) Max. Ballast case temp. Should be 75°C for all ballasts, please amend.
However, Max. Ballast case temperature of 80°C and 85°C are acceptable on condition that at least the life
time specified in the project specifications should be achieved and the ballasts should be guaranteed by the
manufacturer to the project contractual requirements.
Response : With reference to Interior lighting general specification # 265 100 , part# 2 section # 2.3 point L,
we comply that For HF electronic ballast.
35) All lamps shall be energy class-A (very efficient), except 4 pin compact fluorescent lamps class- B is accepted.
Response: Comply.
Page 5 of 7
SLCo
d.,p qA.ill..JI JUJJI
Saud i Lighting
37) Manufacturer and supplier should confirm t hat all lamps mercury content will be suitable for proper
operation, life time, lumen and emergency operation with batteries. Moreover, final approval will be subject
to sample test on site before delivery and acceptance .
Response: Comply; please see attached technical data for lamps.
38) Ballasts of all fluorescent lamps are to be electronic type, pre-heat, rapid start, with Energy Efficiency Index
EEI=A1BAT for dimming light f itting and EEI=A2BAT for non-dimmable ones.
Response : No Dimmable balla st requires in the project, for non-dimmable EEI=A2BAT is not applicable .
With reference to interior general Spes# 265100 -Part 2- Section 2.3- Point# K- We comply that
Energy Efficiency Index EEI=A1 for dimmable light fittings and EEI=A2 for non dimmable ones.
39) Wiring inside fixture should not be less than 1.5 mm2 heat resistant type as specified with connecting
terminal for 2.5 mm2 and to be sufficient for loop in - loop out wiring.
Response: For fluorescent lighting fixture 1.5mm2 internal wiring is not possible with fluorescent ballast
terminal, referring to interior general specification # 265100 - Part 2 - Section 2.2 - Point# N : we comply
that the internal Wiring Inside Fixtures: Not less than 0.5 mm2. Termina l block allow connecting up to
2.5mm2.
40) Self-contained Lighting fixtures are to be equipped with a self-diagnostics auto device with led test indicator.
Response: Comply.
41) Confirm with supporting documents that and the self-conta ined fitt ing battery is Sealed, maintenance-free,
nickel-cadmium type with adequate number of cells (5 cells most recommended) to provide maximum LOR
for 3 hours operation for fluo rescent lamps and 100% lamp lumen for halogen and LED lamps.
Response: For fluorescent lamps, emergency backup is not required, for halogen lamps please refer to
attached technical submittal lighting fixtures types E1 and E2.
42) Confirm with supporting documents that the Charger is fully automatic, solid-state, constant-current type
with sealed power transfer relay.
Response: please refer to attached technical submittal lighting f ixtures types E1 and E2.
43) Certificate of origin together with a bill of lading endorsed with local custom stamp to be subm itted together
when materials are delivered to the site and to show clearly the country of origin of the proposed materials.
Response: Noted.
Page 6 of7
~
~
SLC
~ d.,p~l oJUPI
.......... Saudi Lighting
44) Mer2 ry contents for self-contained fitting with battery shall be coordinated with battery kit manufacturer
to ensure no steering effect (dark rings) .
C) Structural comments :
1) Structural (steel and concrete) calculations are to be submitted for each type of poles and high masts
separately for review and approval.
Response: For poles and high mast to be submitted separately upon we finish the design and calculation
according to project requirements.
2) All steel members, anchor bolts shown in this BID are considered to be indicative and contractor shall submit
design calculations and drawings for each case separately.
Response: For poles and high mast to be submitted separately upon we finish the design and calculation
according to project requirements.
Best Regards;
Page 7 of 7
Response for comment # 13
Response for comment # 14
Ahmad Alazizi
From: Ahmed Ali Mohamed Harara [a.harara@visionem.net]
Sent: Monday, February 11, 2013 11:48 AM
To: Ahmad Al-Azizi
Cc: 'Fahmi Dibis'; Rebhi El Yahia; Hani Begermy; Hisham Tahawi; Mohamed Abdel Ghany;
Mohammad A. Haj Mustafa; Hassan Mohamed Ali Badawy
Subject: FW: 534: Masa'a AC Plant at Ajyad - Makkah Haram - MAS-MA-EL-LI-039 Rev.04 -
Lighting Fixtures - Saudi Lighting - K.S.A (DarRef: Not Referenced)
Attachments: MAS-MA-EL-LI-039-Rev 04.pdf; Doc.pdf
With reference to the above mentioned material submittal regarding the following:
1
The proposed ballasts for fixtures with EEI (energy efficiency index) = A3 which is not
accepted, to be with EEI = A2.
2. Alternative lamps for types M1, M1A, M2, M2A & M3 Code B
Final approval is subject to the approval for samples by site engineer.
3. Alternative capacitor for types M1, M1A, M2, M2A & M3 Code B
Final approval is subject to the approval for samples by site engineer.
For your information and further action.
Best regards
Magdi Maurice on behalf of
Alaa Khalifa
From: Ahmed S. El-Halous [mailto:a.elhalous@visionem.net]
Sent: Monday, February 04, 2013 10:10 AM
To: Alaa Khalifa (Alaa.Khalifa@dargroup.com)
Cc: Ahmed Ali Mohamed Harara; Abeer Mohamed El-Kadry; Ahmed Mostafa; Jihad Kahil ; karim magdy; Magdi
Maurice; Tarek Zaher ; Elhussein Ibrahim; Mohamed Elsayed; Usama Hamad; Ahmad Mashhout; Hani Begermy;
Hisham Tahawi; Kefah A. Aldmour; Mohamed Abdel Ghany; Mohammed Ahmed Ali Rumman; Rezk Alemam Abdou
Subject: Masa`a Ac Plant At Ajyad - Electrical Material submittal for Approval - MSA-AJ-MAT-251-13
Dear Mr. Alaa
Please find attached Letter Ref# MSA‐AJ‐MAT‐251‐13 for Electrical Material Submittal for your review and approval
You shall receive the hard copy & the soft copy through Mr. Mohammed El‐Sayed (Vision Cairo)
Best Regards,
Ahmed Seleem El‐Halous
Document Controller
Vision E/M Co. Member of Saudi Binladin Group
Phone : +966 2 616 5730 ‐Ext.4057 ‐ Mobile : +966 596 387 344
Confidentiality & Disclaimer Note: This e-mail and any attachments thereto contain protected and confidential
information intended for the sole use of the addressee individual or organization. If you are not the addressee or an
authorized agent for him/it, or if you have received this message by error please notify the sender immediately by
returning the message, and delete this copy from your system without any illegal use.
The Dar Group shall not be liable for the improper or incomplete transmission of the information contained in this
communication nor for any delay in its receipt or damage to your system.
2
Compliance Sheet for General Specifications
Interior 265100 & Exterior 265600
MAKKAH FlRST Rl G ROAD AND BUS STATIO S- KUDAI AND BERKAH TUNNELS
PART I - GENERAL
I. I RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, includi ng Conditi ons of Contract and
Division I Specificatio n Sections, apply to this Section.
1.2 SUMMARY
A. T his Section includes exterior lig hting units w ith luminai res, lamps, ballasts, poles/support
Noted structures, and accessories and related power distribut ion and control, protective earthing
and re lated builder's work including column foundations, cable pits, cable trenches and
ductwork.
Noted
1.3 DEF INIT IONS
A. Lig hting Unit: A luminaire or an assembly of luminaires complete with a common support,
including pole, post, or other structure, and mounting and support accessories.
B. Luminai re (Light Fixture): A complete lighting device consisting of lamp(s) and ballast(s),
when applicable, together w ith parts designed to distribute light, to position and protect
lamps, and to connect lamps to power supply.
A. Equipment Data: For each type of lighting unit ind icated subm it complete data fo r approval
including, but not limited to, the followi ng:
I. Detailed literature, in English, for each type of luminai re or fixture, lamp and control
Comply, refer gear includ ing manufacturer's name, catalogue number, rating, material specificatio n,
to technical overall dimensions, operating characteristics and principles, and any modification to a
submittal standard product if applicable
2. Detailed specification and drawings for each column type includ ing shape,
base/mounting fl anges, bolts, nuts etc, cross-sections, desig n criteria and calculations,
brackets, fi nishes, provisions fo r cabling, cut-o ut or circuit-breaker etc.
3. Photometric data for lighting calculations inc lud ing polar curves, coeffic ients of
uti lization, efficiency and depreciation factors.
4. Materials and dimensions of luminaires and poles.
5. Certified resu lts of laboratory tests for fixtures and lamps for photometric
perfo rm ance.
6. High-intensity-discharge luminaire ballasts.
EXTERJOR LI G HTING
S12027-0100D-FD-TN-S PC- EL-0 1 REV 0
MAKKAH FIRST RING ROAD A D BUS STATIO S- KUDA I A D BERKAH TU ELS
B. Shop and Construction Drawings: Submit drawi ngs fo r approval including, but not li mited
to, the following: By Contractor
C. Samples: submit full y equ ipped sample of luminaire or other materials or components if
required by Engineer. Comply, After technical submittal approval
D. Prod uct Certificates: Signed by manufacturers of lighting units certifying that products
comply with requirements.
Comply
E. Field Test Reports: Indicate and interpret test results for compliance with performance
requirements.
A. Standards: Luminaires generally are to comply with IEC 60598 and the app licable C ISPR
recommendations. Manufacturer is to verify compliance with these standards and the
applicable local regu lations and desig n standards. Comply
A. Store poles on decay-resistant treated skids at least 300 mm above grade and vegetation.
Support poles to prevent distortion and arrange to provide free air circulation.
B. Retain factory-applied pole wrappi ngs on poles until just before pole installation. Handle
poles with web fabric straps.
A. Furnish extra materials described below that match product installed and that are packaged
with protective covering for storage and identified wi th labels describing contents.
I. Lamps: I 0 for every I 00 of each type and rating installed. Furnish at least one of
each type.
2. Glass and Plastic Lenses, Covers, and Other Optical Parts: I for every I 00 of each
type and rating installed. Furnish at least one of each type.
3. Ballasts: I for every 100 of each type and rating installed. Furnish at least one of
each type.
4. G lobes and Guards: I for every 20 of each type and rating insta lled. Furn ish at least
one of each type.
PART 2 - PRODUCTS
2. 1 MANUFACTURERS
A. Products : Subject to com pliance with requirements, provide one of the products indicated
for each des ignation in the Lighting Fixture Schedule shown on plans.
C. Column Design: Colum n cross-section, thickness of steel, joints, welds, bolts etc. are to be
designed to withstand gust wind velocity of 160 km/hr blowing in the most unfavorable
direct ion at a height I 0 m above ground level, with column fully equipped. Fatigue of steel
is in no case to exceed half elasticity limit, taking into account dynamic stresses due to
vibrati ons. Steel fl ange plate, of adequate thickness, is to be so lidly welded onto lower edge
of column as shown o n the Drawings, and is to have specified number of holes fo r holdi ng
down bolts together with central cable access hole not less than 150 mm diameter.
E. Finish: Welds are to be smooth with spatter removed, inside and o utside surfaces of column
are to be cleaned by pickling or blasting and are to be free of grease. Steel components of
columns to be hot-dip galvanized after fabrication. Minimum thi ckness of zinc coating is to
be 500 glm2 o n both inside and outs ide surfaces of column. Galvanizing is to be to NF A 91
I 121 o r BS EN ISO 1461 . Any damage to galvanizing is to be rectified during erection by
wire brushing affected area and treating with approved rust converter to the satisfaction of
Eng ineer. Flange plate and inside and outside of column base are to be coated with heavy
bitumen paint prior to erection.
Lighting poles to
be submitted F. Protection and Wiring: Columns with one or two luminaires are to be connected over one
phase and neutral. Columns with three or more luminaires are to be connected over 3 phases
separately along
and neutral, unless otherwise shown on the Drawings. Bolted terminals and cable lugs are
with compliance to be provided with 3 phases and neutral terminals, for incoming and outgoing 3 phase 4-
sheet, a waiting wire cable, and of the s izes shown on Drawings. One circuit breaker, single pole 6 A is to
poles final design be provided for each phase leading to a luminaire. Circuit breakers are to be compensated
according to and rated for 50 deg. C ambient with interrupting capacity of at least 9 kA, and are to be
project and site mounted in weatherproof enclosure at baseboard. Wiring is to be PVC insulated 3 core or 4
requirements . core 85-deg. C conductor temperature. Cable is to be at least 4 mm2 copper conductor.
A. Constructi on: Totally enclosed, dust protected and splash proof, conforming to at least IP 54
of IEC 60529, shock resistant and specially designed to house required lamps, electrical
gear and accessories. Body is to be corrosion resistant, extruded, pressure die-cast or
fabricated aluminum alloy comply
B. Finish: Exposed metal parts of lumi naires are to be factory finished, stove enameled, with
suitable corrosion resisting paint capable of resisting heat emitted by lamp during
continuous operation, and under full sunlight cond itions. Color is to be agreed with
Engineer. Comply, color as per SLC standard color, samples will be submitted.
C. Mirror Reflectors: 99.5% purity, glazed and anodized aluminum or die-cast, super-purity
aluminum vapor-deposited, and coated with transparent layer of si licon protection against
wiping. Comply
D. Luminaire Protectors: Heat and shock resistant glass, mounted into suitable frame assembly
fixed to body by captive screws, and secured by extra safety clamps to allow replacement of
protector and reflector. Ozone resistant ethylene propylene or approved equivalent rubber is
to ensure sealing of the front glass. Comply
E. Lamp Sockets: High-grade porcelain, mounted in support brackets with provision to adjust
lamps vertically and axially. Lamp support and locking system are to grip and prevent lamp
movement in operation. N/A
I. Lamps: Number and types shown on the Drawings and as described in Division 26 Section
"Interi or Lighting" . Comply
2.4 FLOODLIGHTS
A. Type: Totally enclosed type, weather, dust and shock resistant, IP 64 of IEC 60529. Comply
B. Housing: High pressure die-cast al uminum alloy, closed on front by hinged framed protector
highly resistant to thermal and mechanical shocks, and set in position by at least eight heavy
duty stainless steel spring clamps with silicon sealing gasket. Enclosure is to be in
accordance with IEC 60598-2-5, and is to be suitable for operation in an am bient
temperature of 70 deg. C. Comply, with four stainless steel spring
C. Refl ectors: High purity (over 99% reflectance) anodized aluminum, secured in precision
aligned internal tracks to provide beam distri bution required. Comply
D. Connection box is to be located at rear of floodlight body with gland connections to accept 4
mm2 PVC/PVC three core cable. Lamp and control gear to be mounted in two separate and
isolated compartments. By contractor
E. Control Gear: Plug-in type, [230] V, [60] Hz, power factor compensated to at least 0.9
lagging. Ballasts and ignitors are to be type specially adapted for make of lamps selected.
Ignitors are to be electronic thyristor type. Lamp is to be able to start with at least +/- 10%
line voltage, and with normal operation dips up to 20% for four seconds. Compensation is
to ensure that there is no large increase in operating current during starting. Control gear
losses are not to exceed I0%. Cables for internal wiring in control gear compartments are to
be single core 2.5 mm2 copper conductors with high temperature insulation and sheath.
Comply with 1.5mm 2 internal wiring instead of 2.5mm 2
F. Finish: Exposed metal parts of floodlights are to be painted with corrosion and heat resistant
paint, res isting operating temperatures attained in direct sun light while lamp is burning. Comply
G. Mounti ng: Floodlights are to be located as shown on the Drawings and mounted on
specially designed brackets to allow swiveling in any desired direction and locking fi rmly in
fi nal position. Protractor scale is to be provided for accurate setting. By contractor
B. Provide high masts complete with lifting/loweri ng mechan ism, lum inaire ring, etc. and
install as shown on the drawings.
C. The contractor shall fix the high masts on prepared foundations, aligned properly. The
system shall be in fully operational conditions to suit the ICAO requirements for the lighting
of the Apron. Warning lights are to be provided on top of the high masts. Control gear
panel is to be provided within the high mast for power distri bution to the different
flood Iights.
D. General: The luminaires shall be mounted on the luminaire ring by means of a specially
designed bracket allowing it to be swiveled in any desired direction. It shall be poss ible to
lock it firm ly in its pos ition, thus preventing any rotation or falling wh ile moving the
lumi naire ring.
The head frame shall be covered by a shaped protective aesthetic canopy designed to give a
coordinated appearance of head frame with the luminaire ring.
For masts fitted with a mobile luminaire ring, rollers with a centering mechanism shall be
provided to ensure a perfect alignment of the lumi naire ring both axially and in azimuth,
whi le asce nding or descending the mast. Ro llers shall be made of water resistant non-
marking composition material with oil-im pregnated bronze brushings. All shafts and
washers shall be stainless stee l.
A weatherproof wiring chamber shall be provided and installed on the luminai re ring and
shall be equipped with the proper terminal blocks and neutral bar and shall include faci lities
o n the lum inaire ring to allow test ing of luminaires while in the lowered position. The
wiri ng chamber shall be fitted with an earthing stud access ible from ins ide and out for
earthing connections.
T he cable connecting the MCB assembly at the base of the mast to the wiring chamber on
the luminaire ring, shall be flexible multicore copper conductors cable with neoprene or
approved equivalent hi gh temperature res istant insulation and sheath in accordance w ith BS
6977 or IEC 277-6.
High Mast to be
submitted For mobile luminaire rings a multi-pin type plug and socket shall be fitted in the flexib le
separately along cable adjacent to the power control and d istri bution unit housing in the base, for
with compliance disconnection of the rising cable.
sheet, a waiting
poles final design Color coding of the di ffe rent phases shall conform to the standards. Each luminaire shall
according to have its own neutral conductor and earth cond uctor connected to the neutral bar and earth
bar respectively.
project and site
requirements . The cables installed in the lum inaire ring connecting each luminaire to the wi ring chamber
shall be factory pre-wi red avo iding the need for field wiring, and shall have single core
Copper conductors with neoprene or cross-linked polythene or approved equivalent
insulation and sheath. Cables shall have 2.5 sq. mm Copper conductors with colour coding
of d ifferent phases being in conformity with the Standards.
The luminaire ring shall suit the number of floodlights as per the drawings.
The high mast lumi naire support ring or carriage shall be constructed of hot dipped
galvanized steel channel fitted with the appropriate number of luminaires, lamp gear
mounting brackets, wiring cham ber and mounting plate. It shall be in two halves joined by
bolted fl anges to perm it removal from the erected mast.
F. A steadying system shall keep the luminaire ri ng in the correct top position avoiding any
rotation aro und its vertical axis.
The luminaire ring shall be raised and lowered for installation and maintenance purposes by
means of a winching system specially designed to be installed and removed through the
access door at the base of the mast.
G. Winchi ng System:
The capacity of the winching system against the fl ood lig hts is to be calculated and ensured.
The head frames shall be hot-d ipped galvani zed steel attached to the mast by means of a
steel slip-fitter and secured by at least four stainless steel set screws. They shall be
composed of a spun aluminum or other approved weatherproof cover, housing the required
number of steel cable sheaves and associated accessories for the operation and powering of
the lum inaire ri ng.
Pulleys shall be of non-corrosive material grooved to exactly s uit the steel rope and cable
diameter, and fitted with stainless steel shafts. The pulleys shall be housed in a chassis
integral with a s leeve which s lopes over the top of the mast and is secured axially and in
azimuth. The complete chassis assembly shall be hot d ipped galvanized. Arrangements
shall be provided to ensure that the electric and steel cables are separated before passing
over their respective pulleys, and close fitting guides shall ensure that the cables cannot
disengage the pulley during operations.
The luminaire ring shall be supported by 3 steel ropes coupled to 2 steel ropes and
suspended from the double drum winch by means of a manufactured steel coupling unit. A
High Mast to be divider bar shall ensure the separation of the steel ropes during rais ing and lowering.
submitted
separately along Flexible stainless steel stranded wire ropes in accordance with BS 302 suitable for the
with compliance application, with factor of safety 5 times S.W.L. of the winch, shall support the lumi naire
ring assembly. Stops installed on the steel cable shall support the lumi naire ri ng assembly
sheet, a waiting
in extreme lower position to withi n 900mm above the base of the mast. Provis ions shall be
poles final design made to prevent the power cable from winding around the steel hoisting ropes.
according to
project and site A multicore electrical power cable s hall be provided terminating in the base compartment
requirements . wi th a special multi-pin pl ug and socket coupler fitted with a guard ring, and at the mast
head connected to a wiring chamber fixed to the luminaire ri ng.
A steadying system shall keep the luminaire ring in the correct top position avoid ing any
rotation aro und its vertical axis.
The luminaire ring shall be raised and lowered for installation and maintenance purposes by
means of a winchi ng system specially des igned to be installed and removed through the
access door at the base of the mast.
The winching system shall have a li ft ing capacity of at least double the weig ht of the
luminaire ring assembly and their maximum windi ng torque during operation shall be
specified. The winchi ng system shall employ double drums as a safeguard against a single
suspension steel wire rope failing.
Wi nches shall be capable of normal operation using a portable power tool which shall be a
multispeed reve rsi ble ty pe incorporating torque lim iting device wh ich can be readily
adjusted and locked in any adjustment. The power tool shall be equipped so that the
operator can be positioned clear of the moving head frame and usi ng push-button controls
at the end of a Sm long flexible lead. A power unit mounting or support frame shall be
provided for locati ng and securing during o perations.
Termination of winch cables shall not involve distortion or twisting of the cable structure.
One fu ll layer ofturns shall remain on the drum when the lumi naire ring is full y lowered or
alternatively the drums shall be g rooved to ensure a tidy cable lay.
Manually operated winches shall be prov ided with handles and shall incorporate a torque
li miter which can be readily adj usted and locked. Winches shall be completely self-
sustaini ng without the need for brakes or clutches which require adj ustment or which can
be affected by moisture or lubricant shall not be used.
Winch gear shall be totally enclosed and self-lubricating by means of an oil bath. Only
lubricant recommended by the supp lier shall be used. The gear ratio shall take into account
operational safety and speed.
An MCCB providing overload protection shal l be incorporated to stop the luminaire ring
when the effort req uired by the winch becomes superior to the nomi nal load.
The wi nch shall be fitted with suitabl e equipment to allow the wi nch to stop in a safe
manner, without damage to the mast finish, in the event of a supply failure to the power
tool. The winching mechanism should then be capable of being operated by hand.
H. Finish : All welds shall be smooth with spatter remover and the interi or and exterior surfaces
of the mast and ring shall be cleaned by pickling or blasting and shall be free of any grease .
I. All components shall be hot dipped galvanised by total immersion in a bath of molten zinc
after completi on of the fa bricati on. No further leveling up, fini shi ng or modifications shall
High Mast to be be carried out after completi on of the galvanising process. The minim um th ickness of zinc
submitted coating shall be 450g/m2. on the inside and o utside surfaces of the mast and ring. The
separately along galvanis ing shall conform to BS 729: 197 1.
with compliance
Any damage to the galvanising shall be rectified during erection by wire brushing the
sheet, a waiting
affected area and treating with an approved zinc restorative. Sufficient material shall be
poles final design applied to provide a zinc coating at least equal in thi ckness to the galvanised layer.
according to
project and site The flange plate and bottom of the pole to a height of 0.5 m shall be given an internal and
requirements . external coating on all surfaces of heavy-duty bitumen paint prio r to erection.
J. High Mast Distributi on Equi pment: The hi gh mast base compartment shall be fitted with a
power control and d istribution assemb ly installed in a pre-wired weatherproof box opposite
the access door inside the base of the mast.
K. The assembly shall consist of a surface mounting sheet steel weatherproof box with a cover
enclosing breakers as shown on drawings.
L. High Mast Accessories: High masts shall be eq uipped with an air terminal of the correct
height to provide the required zone of protecti on fo r the mast head frame and fixt ures. The
air termina l shall be bonded to the mast to ensure the discharge is dissipated via the earth
and g round terminal without damage to the steel wi nch ropes or electri cal cables.
Hig h masts are to be equipped with a red luminaire o n top for aircrafts. Two lamps are to be
provided per high mast.
M. High mast approval : For the approval of the Engi neer before installation commences the
Contractor shall submit detailed calculat ions and supporting data to show the mast meets the
design criteria detailed and shall include the follow ing information:
The deflection at the top of the mast at the designed wind speed.
The neutral frequency of the mast.
T he critical wind speed for resonance.
T he damping characteri stics of the mast.
A. Description: this work shal l consist of supplying, complete with the necessary base,
mounting, testing and putting into satisfactory operation of feeder pillars which shall
generally be used to feed electri cal lighting and other installati ons as req uired.
B. Construction: the feeder pillar shall be totally enclosed full y self-contained dust-proof,
weather proof and suitable for mounting outdoors exposed to dust, rain and sun light.
D. Characteristics: the feede r pillar shall be complete with all equipment and fittings
incorporating moulded case circuit breakers controlling the main supply in and the outgoing
circuits. The pi llar shall have the following main characteristics:
Voltage 1000 volts.
Moulded Case Circuit Triple/single pole rated as shown on Drawings
Breakers ( MCCB) For Incoming and outgoing circuits.
Interrupting Capacity 35000 amperes RMS symmetrical
E. Contactors: shall be triple-pole. inductive type, rates as shown on the project drawings.
G. Internal Cabling: to be PVC/ PVC o r XL PE/PVC single core I 000 volt grade with copper
conducto rs and rated as required taki ng into account manufacturers recommended
temperature and "bunching" derat ing factors. All internal wi ring shall be suitably "laced" or
clipped.
H. Contro l: the LV pane l circuits serving the street lighting shall be supplied through triple pole
contactors which shall be photo-electric controlled. An over-ride facility shall be provided
for maintenance. The photo-electric controls shall consist of an omni-directional cadmium
I. Feeder Pillars: shall have a 50 mm x 6 mm high conductivity copper main earth bar for
grounding purposes complete with test (see "earthing"). Also, permanently fixed to the
inside of the door there shall be a distribution diagram showing all circuit connections,
By Contractor MCCB ratings, cable sizes and references, etc.
J. Feeder Pillar: shall be secured against unauthorized access by means of wedge locks
protected by brass plugs and operated by a special key to be agreed with the Engineer or as
applied by the local authority. The pillar fi nal fi nish and final colour shall be to the approval
of the Engineer and similar to the colour of Power Distribution Boards.
3.2 LV CABLING
A. Cables: shall be mul ticore w ith copper conductors, PVC or XLPE insulated I 000 V and
shall be as specified under secti on 2605 19.
PART 4- EXECUTIO
A. Eq uipm ent: Install eq ui pment to be readi ly accessible for operation, maintenance and repair.
Minor deviations from the Drawings may be made to accompli sh this but no changes are to
be made without the approval of Engineer.
B. Column Bases: Install columns on concrete bases as detailed on the Drawings. Before
commencement of construction, ensure that bases are suitable for column installation.
C. Holding Down and Plumb Adjusting uts, Washers, Locknuts or Ny loc N uts: Stainless
steel or cadmium plated.
D. Columns: Erect col umns so that lum inaires are located on a line paral lel to theoretical
profile of road. A lignment of columns, both horizontally and vertically, is to be secured to
the satisfact ion of E ng ineer. Brackets are to be set at 90 degrees to longitud inal axis of
road.
I. Use web fabric slings (not chain or cable) to raise and set poles.
2. Mount pole to foundation with leveling nuts. and tighten top nuts to torque level
recommended by pole manufacturer.
3. Secure poles level, plumb, and square.
4. Grout vo id between pole base and foundation. Use non-shrinking or expanding
concrete grout firmly packed in entire void space.
5. Use a short piece of 13-mm diameter pipe to make a drai n hole through grout.
Arrange to drain condensation from interior of pole.
F. Luminaire Attachment with Adjustable Features or Aiming: Attach luminai res and supports
to allow aiming for indicated lig ht distribution.
I. Lamp luminai res with indicated lamps according to manufacturer's written instructions.
By Contractor Replace malfunctioning lamps.
J. Cabling Conduits and Ductwork: Carry out in accordance with Division 26 Section
"Conductors and Cabling" . Cable ducts are to be di rectly buried except at crossings with
other service work or roads.
B. Insulation resistance and continu ity tests are to be carried out on each circuit and piece of
equipment before energization, with circui t breakers in the open position and lamps not
installed.
C. Operational tests are to be carried out on all circuit breakers and control gear, with lamps
installed, including recording voltage at terminals of ballasts on fi nal columns of each
circuit and at distribution panel or the like.
D. Performance tests are to be carried out after I 00 hours normal operation, and are to include
measurement of lighting and uniformity levels on req uired illum inated surfaces.
E. Other tests are to be carried out as required by the Engineer to verify conformity with the
Specification.
F. Earthing resistance tests are to include measurement of earth electrode resistance at final
points of circuits and continui ty of protective conductors.
I. Tests and Observations: Verify normal operation of lighting units after installing luminaires
and energizing circui ts with normal power source, and as follows :
J. Prepare a written report of tests, inspections. observations and verifications indicating and
interpreting results.
K. Malfunction ing Fixtures and Components: Replace or repai r, then retest. Repeat procedure
until units operate properly.
4.3 CONNECTIONS
A. Ground Eq uipment:
A. Clean units after installation. Use methods and materials recommended by manufacturer.
B. Adjust amiable luminaires and luminaires with adjustable lamp position to provide required
light distributions and intensities.
PA RT 1 -GENERAL
A. Drawings and general provisions of the Contract, including Conditions of Contract and
Divis ion I Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section inc ludes interior lighting fixtures , lighting fixtures mounted on exterior
buildi ng surfaces, lamps, ballasts, emergency lighting units, mounting provisions and
connection to circuit wiring and to corresponding lighting contro l equipment.
1.3 SUBMITTALS
A. Equipment Data: Submit data for approval including, but not limited to, the following:
I. Detailed literature on each fixture , lamp and control gear including manufacturer's
name, catalogue number, rating, material specification, overall dimensions, operating
characteristics and principles
Refer to attached 2. Details of changes to standard fixture s for adaptation to condition of installation and
technical submittal to the Specification
3. Photometric data for lighting calculations including polar light distribution curves,
coefficient of uti! ization , glare classification, efficiency, depreciation factors etc.
4. Dimensions of fixtures.
5. Certified results of laboratory tests for fixtures and lamps for photometric
performance.
6. Emergency lighting unit battery and charger.
7. Fluorescent and high-intensity-discharge ballasts.
8. Cold cathode and LEOs control gears.
9. Energy-efficiency data.
10. Life, output (lumens, Co lor temperature, and CRI) and energy efficiency data for
lamps.
II . Types of lamps.
B. Shop and Construction Drawings: Submit Drawings for approval including, but not limited
to, the following:
I. Exact position of each fixt ure on reflected ceiling plans, with indication of ceiling
By cotractor features , struct ural mem bers, ducts, pipes and other fittings, as applicable and
pertinent to the installation.
2. Installation details including suspension and mounting provisions.
3. Purpose made fixtures or lighting assemblies with full detai ls.
4. Wiring detail s, circu it and panelboard references , special lighting control
arrangements etc.
C. Samples: Submit fully equipped sample of each fixture type, modified if required, together
with color and texture samples of each fixture. Comply, after technical submittal approval
E. Coordination Drawings: Reflected ceiling plans and sections drawn to scale and
coordinating fixtu re installation with ceiling grid, ceiling-mounted items, and other
components in the vicinity. Include work of all trades that shall be installed near lighting
equipment. By cotractor
A. Fixture Design and Standards : The Specification and the Drawings are a guide to the
selection of lighting characteristics and lighting fixtures , giving general features of
construction, materials, method of installation and conditions of operation. Unless
otherwise specified, fixtures shall be manufacturer's standard series, designed and
manufactured for the purpose and application required, generally in accordance with the
Schedule of Lighting Fixtures and complying with IEC 60598 and BS EN 55015. Noted
B. FM G lobal Compliance : Lighting fixture s for hazardous locations shall be listed and
labeled for indicated class and division of hazard by FM Global.
N/A no Hazardous fixtures required in the project
1.5 COORDINATION
A. Design Layout: Fixture layout has been determined from photometric data of specified
fixtures to achieve desired level and uniformity of illumination. Reflected ceiling plans
shall be checked to ensure exact positions of fixtures with res pect to structural members,
ducts, pipes, other installations and cei ling panels/tiles, where required. Certain fixtures are
shown in provisional positions, pending preparation of fina l equipment layout drawings.
Such fixtures shall be located in coordination with final equipment layout so that
illumination is as intended by the design . Please refer to attached lighting design that has been
0 0 0 do n.e in acco rdance with the o.ropose.d liahtinQ
B. Fixtures, Mountmg Hardware, and Tnm: Coordmate ayouf and mstaflatiOn ot 1Iglitlf1g ·
fixtures with ceiling system and other construction . Noted
A. Furnish extra materials described below that match product installed and that are packaged
with protect ive coveri ng for storage and identified with labels describing contents.
Comply, upon
1. Lamps: I 0 for every I 00 of each ty pe and rating installed. Furnish at least one of
request on each type.
contractor 2. Plastic Diffusers and Lenses: 1 for every I 00 of each type and rating installed.
account Furnish at least one of each ty pe.
3. Battery and Charger Data: For emergency lighting units.
4. Ballasts: 1 fo r every 100 of each ty pe and rating installed. Furnish at least one of
each type.
5. Globes and Guards : 1 for every 20 of each type and rating installed. Furnish at least
one of each type.
PART 2- PRODUCTS
A. Products : Subject to com pliance with requ irements, provide one of the products indicated
for each designation in the Lighting Fixture Schedu le shown on Drawings or approved
equal.
A. Generally: Construction and wiring of fixtures shall comply with the Regulations and
Standards. Fixtures shall be fabricated , assembled and wired entirely at factory.
Comply Manufacturer's name, factory inspection stamp and official quality label shall be fixed to
each fixture supplied .
C. Sheet Steel Housings: Not less than 0.6 mm thick, and thicker when required by the
Spec ification or the Standards.
E. Aluminum Reflectors: Not less than 99.5 % purity and not less than 0.7 mm thick, unless
otherwise approved.
F. Fabrication : Metalwork shall be m itred , welded and ground smooth without tool marks or
burrs. Flat metal parts shall be stiffened by forming grooves and edges during fabrication .
Comply Metal parts shall have finish free from irregularities.
G. Rust-proof Ferrous Base : Ferrous metal parts shall be bonderized (treated w ith corrosion
resistant phosphate solution) and given an approved rust-inhib iting prime coat before
application of final finish.
H. Finish for Non-Reflec ti ng Metal Surfaces: Approved baked enamel paint. Paint color on
fixture frames and trims shall be as spec ified or as selected by the Engineer.
I. Finish fo r Light Reflecting Surfaces : White baked enamel paint having reflection factor not
less than 85%. Mirror reflectors, where specified, shall be highly polished , anodized
alum inum with reflecti on factors not less than 97%.
J. Mechanical Resi stance of Finish: After fi nish has been applied on steel surfaces and cured,
it shall withstand a 6 mm radius bend without showing signs of cracking, peeling or
loosening from base metal.
K. Resistance of Finish to Ultra- Vio let: Finish shall withstand 72 hours exposure to an ultra-
violet RS lamp placed 100 mm from surface without discoloring, hardening or warp ing, and
Comply shall retain the same reflection factor after exposure.
L. Heat Resistance: Finishes, wires and components inside fixtures shall be certified materials
to resi st the temperatures or other cond itions encountered in the fixtures .
M. Lamp Cap Temperature Rise Test: Comply with lEC 60360 when testing incandescent or
discharge lamps for compliance with the limits fo r each type oflamp.
N. Wiring Inside Fixtures : Not less than 0.5 mm2 , and insulated for 240 V application.
Insulation shall have acceptable characteristics to resist maximum temperatures inside
fixtures . Wiring shall be terminated on sc rew type, fixed , insulating, terminal blocks.
0. Hinges : Fixtures with visible frames and hinged diffusers shall have concealed hinges and
catches, and stain-less steel retain ing cli ps. Other alternative equally durable products may
be submitted for approval.
P. Suspension Aligners: Provide for pendant fixture s for axial , vertical and horizontal
alignment. Vertical adj ustment shall be minimum 25 mm. Out of our scope, by contractor
R. Recessed down light fixtures shal l be prov ided with "trims" to architectural approval and
Comply shall not have visib le fixing screws or clips.
S. Outdoor Fixtures : Non-ferro us metal or specially molded material for outdoor use.
T. Removal of parts for maintenance shall be possib le without removing fixture housing.
U. All down lights shall be provided with heat tempered safety glass.
A. Lamp Holders Generally: To lEC 60400, heavy duty, molded white plastic with non-
corroding spring contacts.
B. Lamp Holders for Industrial Fittings : Spring loaded turret type, heavy duty, dust protected.
Comply
C. Ballasts Generally: To IEC 60921, IEC 61 347-2-8 and IEC 6 I 347-2-11. Only single or
two-lamp ballasts shall be used in any one fixture . Two-lamp ballasts shall be lead-lag,
series type. Equi pment shall be enclosed in sheet steel casing with corrosion and heat
resistant finish.
D. Ballast thermosett ing com pound shall not soften, liquify or support combustion under any
operating condition or upon ballast failure, and shall fill ballast enclosure and dampen
vibrations. Temperature rise, under norma l operating conditions, shall not exceed 55 deg. C
above maximum ambient temperature of 40 deg. C.
E. Ballast Protection : Each ballast shall have one-time external fuse and fuse holder rated in
accordance with manufacture r's instructions in addition to internal thermal protection.
F. Ballast Type: Preheated, warm rapid start, electronic or dimming type, as stated in fixture
description and as shown on the Drawings, power factor corrected to above 0.9, having
Comp ly manufacture r's lowest case temperature . Sound rating shall not exceed level given in the
Standards.
G. Ballast Rating: Ballast shall be manufactured and certified for the specific lamp it controls
and for operation from nominal power supply, with voltage and frequency equal to nominal
vo ltage and frequency of distribution network .
H. Capacitors: To IEC 61048, IEC 61049, having snap-type connectors a nd fastening, bolt type
M8 , for fixing to fixture . N/A
I. Starters, if required , shall comply with IEC 60155 , and shall be selected in conjunction with
respective ballast and lamp. N/A
K. Electronic ball asts shall be used in conjunction with tubular and compact fluorescent
fixtures. Ballast shall consist of electronic integrated circuit desi gn, warm I rapid start,
operating at 20 to 60 kHz, with Energy Effic iency Index EEl= A 1 for dimmable light fittings
and EEI=A2 for non dimmable ones, power factor corrected to above 0.9 . Ballast shall
comp ly with IEC 61347-1 and IEC 61347-2-3 and shall meet the limits of main harmonic
content as defined in IEC 61000-3-2 and comply with radio interference suppression limits
defined in BS EN 550 15 and immunity requirements of iEC 61547.
L. Electronic ballasts shall be designed and constructed to maintain a case temperature not
greater than 90° C when operated at a room ambient of 50° C when tested in accordance
with applicable standards. Ballasts shall be as manufactured by Osram, Lutron, Philips,
Helvar, Universal Lighting Technologies or other equal and approved, with service life in
Comply excess of I 0,000 hours . Use the most efficient combination of four, three, two and/or single
lamp ballasts as recommended by the manufacturer and subject to the Engineer' s approval.
M. Electronic ballast sound rating: all ballasts shall be the manufacturer's best (quietest) sound
rating, w ith the rating clearly indicated on the ballast case. Ballasts found by the Engineer to
be unduly noi sy shall be rep laced without charge prior to acceptance of the job.
N. Electronic ba ll asts shall be designed fo r the spec ified power supply voltage and frequency.
Ballasts sha ll be firmly fixed in the lighting fixtures to prevent vibrations.
0. Remote ballasts shall be furnished in rated enc losures ready for mounting and connection.
Enclosures with more than one ballast shall be furnished pre-wired. Provide acoustically
isolated mounts for remote ballasts and ballast enclosures to ass ure quiet operation.
A. Type : High intensity discharge (HID) fixtures shall be complete units including integral
ballasts (and ignitors for HPS lamps where ind icated) and lamps of requ ired number and
type, and shall have lighting distribution characteristics equivalent to model and
manufacturer indicated in the fixture description. Comply
B. Accessories: Fixtures shall have mounting accessories, such as suspension rods or chains,
rails or brackets, and protective glass covers with gaskets for protection against dust and
humid ity or type of corrosive atmosphere predominant in the location. All parts related to luminare
are included , for suspension installation kit to be coordinated by contractor I out of our scope
C. Ballasts and igni tion devices shall be power factor compensated to at least 0.9 lagging, and
type specially selected for lam p type and size used. Ballasts shall be constant wattage,
autotransformer ty pe, des igned for single frequency operation, nominal [50] [60] Hz, and
operated at the spec ifi ed powe r supply voltage Lamp shall be able to start with at least +/-
10% variation from nominal line volt-age and continue in normal operation with dips
attaining 20% for fou r seconds. Compensation shall ensure there is no great increase in
operating current du ri ng starting and that gear losses do not exceed I 0% of normal wattage.
RF suppression circuit shall be provided. Comply
D. Ballasts for HID lamps: shall be the manufacturer's best (quietest) sound rating, with the
rating clearly ind icated on the ballast case. Ballasts fou nd by the Engineer to be unduly
noisy sha ll be replaced without charge prior to acceptance of the job. Comply
E. The electronic ballast must be earthed (protection class I). Comply (for internal
lighting fixtures)
F. Electronic metal hal ide ballasts: electronic ballasts shall be used for metal halide lamps up
to 150 W rating. Electronic metal halide ballasts shall provide " square wave" output at less
than 200 Hz with no more than ± 0.5% variation in output power at ± I 0% variation in input
line voltage. Electronic metal halide ballasts shall have a minim um power factor of 95% and
T HO of less than I 0%. Acceptable remote mounting distance shall be as per manufacturer
recommendations . Electronic metal halide ballasts shall have a "turnoff' safety function in
event of failed or malfunctioni ng lamps or other abnormal conditions. Comply (for internal lighting
fixtures)
G. Ballast shall meet the lim its of main harmon ic content as defined in IEC 61000-3-2 and
comply with radio interference suppression limits defined in BS EN 55015 and immunity
requi rements of IEC 61547. Comply (for internal lighting fixtures)
2.6 QUARTZ LAMP LIGHTING CONTROL LER Comply (for internal lighting fixtures)
A. General Requirements for Controllers: Factory installed by lighting fixt ure manufacturer.
B. Standby (Quartz Restrike) : Automatically switches quartz lamp on when a HID lamp in the
fixture is initially energized and during the HID lamp restrike period after brief power
outages.
D. Switching Off: Automatically switches quartz lamp off when HID lamp strikes.
E. Switching Off: Automatically switches quartz lamp off when HID lamp reaches
approximately 60 percent light output.
2.7 COLD CATHODE LIGHTING SYSTEM N/A- No cold cathode required in the project
A. Cold cathode lam ps: Lamps shall be 15 or 20 mm diameter as indicated in the fixture
description, I 00 or 200 rnA, lead glass with 1.25 mm min wall thickness, with a minimum
21% lead content, tri- phosphor coated, surface and cove mounted , straight, curved to any
contour and circular runs, dimmable and non-dimmable type at the various areas as shown
on the drawings, premium, warm white deluxe colour (3000°K) , unless otherwise shown on
the drawings, and subject to the Architect and Engineer ' s approval, suitable for operations
on 230 V, 60Hz power supply, with min imum flux output of 1500 or 2500 lumen per linear
meter of lamp length for 100 rnA or 200 rnA ratings respectively. Guaranteed rated life shall
be above 45000 ho urs . The light provided shall be smooth continuous without unattractive
hot spots and shadow gaps. Lamps showing hot spots or shadow gaps shall be rejected.
B. Cold cathode lamps : shall not depreciate more than 20% of output lumens after I 0,000
hours of normal operation . Lamps shall be processed with a high speed mechanical pump of
at least I 00 litres free ai r capac ity, backed up by a 3-stage oil diffusion pump able to
produce a vacuum of I 0-7 and accurate gauges and meters for measuring and controlling
pressures, temperatures, carrier gas and mercury. Completed lamps shall be silicon coated
and aged fo r a minimum of 50 hours. Lamps showing end darkening, stains, discolorations,
spiralling or sputtering shall be rejected.
C. Lamp holders: shall be surface mounted , architectural grade, glazed wh ite porcelain with
bronze spring contacts.
D. Electronic cold cathode control gear: low voltage, high efficiency, low noise, high power
factor output, when dimming is requ ired high power factor output shall be maintained across
dimming range, suitable for operation at the ambient conditions specified for the project.
Control gear shall have constant current output and stable light output independent of mains
supply fluc tuations suitable and sufficient for operating the connected lamp lengths and
types . Control gear shall have no min imum length of lamp.
E. Electronic cold cathode contro l gear shall have open circuit protection.
F. Dimmable control gear, where required, shall be compatible with the dimming system used.
G. Control gear shall comply with IEC 61347-1 and IEC 61347-2-10 and shall meet the limits
of main harmonic content as defined in IEC 61000-3-2 and comply with radio interference
suppression limits defi ned in BS EN 55015 and immunity requirements of IEC 61547 .
A.
Light emitting diode shall be a solid state device embodying a p-n junction, emitting optical
radiation when excited by an electric current. It shall be part of the LED module which is
supplied as a light source. Output color consistency shall be guaranteed and have a Color
Rendering Index (CRf) greater than 90. LEOs shall have an efficacy of 60 lumens per watt
ilS. a J:IJinimJJIT}. Gu?{anteed rated life shall be above 50000 hours .
Comply (for intern 1 ugming Tlxtures J
B. Housing shall incorporate an adequate heat sink which ensures the overall fittings and the
LEOs are kept relatively cool ,
C. Electronic control gear for LED modules : high efficiency, high power factor, suitable for
operation at the ambient conditions specified for the project. Control gear shall have
constant output current or constant output voltage over the whole wattage range independent
of mains supply fl uctuations as shown on drawings and sufficient for operating the number
and wattage of LEOs connected. Guaranteed rated life of the control gear shall be above
50000 hours.
D. Control gear shall have electrical insulation between primary and secondary sides.
Secondary cables from the control gear to LED modu les shall be provided by the LED
supplier. Maximum length between control gear and LED module shall be as per
rpaotJfactLU"e~ ' s rec9mmendations.
Comply (for intern I ugnnng fixtures ,
E. LED control gear shall be protected against electric shock, accidental contact with live parts,
short circuit, overload and shall be earthed (protection class 1).
F. Io;mma ble contml gcac, whc" cequ;"d, shall be compat;blc w;tb the d;mm;ng system used.
N/A- Not Requ ired
G. Control gears shall be compatible with the lighting control system used such as; 1-lOV,
DALI , DMX , etc ..
H. Control gear shall comply with IEC 61347-1 , lEC 61347-2-13 and !EC 62384 and shall
meet the limits of main harmonic content as defined in !EC 61000-3-2 and comply with
radio interference suppression lim its defined in BS EN 55015 and immunity requirements of
IEC 61547 .
A. Halogen Lamp: Lamps shall be 12V halogen with colour temperature 31 OOK gold plated
base pins for protection against corrosion, an ultraviolet stop quartz, an aluminum coated
reflector and cool beam reflector reducing th is heat in the light beam guard lamp wattage
and beam spread shall be as shown on drawings . Lifetime shall not be less than 4000 hours.
B. Electronic step Down transformer: El ectronic step down transformer for 12V low voltage
halogen lamps shall be dimmable high frequency , high power factor type, with adequate
wattage for connected lamp, suitable for mains power supply of 230Y, [Frequency] Hz and
continuous operation at amb ient temperature of 50° C with maximum temperature rise of
Comply I 0° C. T ransformer shall cons ist of electron ic integrated circuit design with suitable casing
for installation above false ceiling, with safety cutout to protect from defects in the unit and
short circuit protection. Transformer shall not produce overvoltage in partial load operation.
Electronic transform er shall be of low power losses type and accordingly low heat
d issipation.the maximum cab le length shall be as per manufacturer' s recommendations. Life
time of the transformer shall not be less than 30000 hours.
C. Transformer shall comply with !EC 61 347-1 and lEC 61347-2-2 and shall meet the limits of
main harmonic content as defined in IEC 61000-3-2 and comply with radio interference
suppression limits defined in BS EN 55015 and immunity requirements of IEC
6154 7/61 047. The manufacturer shall be responsible for checking the radio interference
levels of the complete fixture and ensures that it complies with the values specified by in BS
EN 55015.
2.10 LAMPS
B. Incandescent Lamps for General Lighting Service (GLS) : To have screw base type ES for
lamps 200 W and below and type GES fo r lam ps 300 W and above . Ins ide frosted (IF)
lamps shall be used unless otherwise specified . Guaranteed rated life shall be above 1000
hours and lumi no us output above the following:
C. Reflector Lamps (R): For indoor and outdoor use, with silver reflector and prismatic lens.
Light beam shall be narrow (spot), wide (flood) or extra-wide (wide flood) as indicated in
the fixt ure description .
E. Straight Tubular Fluorescent Lamps: To IEC 60081 (SSA 138 and SSA 139) and, unless
otherwise specified, are to be electronic, bi-p in, rated as ind icated in the fixture description
and with improved fluorescent internal coating. Color of light is to be High colour rendering
warm white equal to Philips no. 830 or Osram no . 31-830 unless otherwise specified.
Lamps are to be low energy type w ith tube diameter 26 mm. Guaranteed rated life is to be
above 8000 hours and luminous output above the following:
F. Straight Tubular Flourescent Lamps-Type TL5: high efficiency fluorescent lamps with a
d iameter of 16mm shall be used as shown on drawings (and as specified in the schedule of
lighting fixtures). Effi ciency shall be over as high as 104 lumens per Watt. Lumen
maintenance of 92% at 10000 burning hours should be achievable using the appropriate
electronic ballast. The lam p should last 20,000 burning hrs at a 3 hrs switching cycle if
operated on HF warm-start ballasts. The lamps should ign ite at from-15deg.C to +50deg C
Comply ambient temperature. With a Colour Rendering Index of 85 , lamp lumens shall be as
follows:
H. SL Lamps : Compact, low pressure, di scharge lamps, integral with control gear, housed in
opal prismatic glass bulb, with ES screw base, and rated as indicated in the fixture
description . Guaranteed rated life shall be above 5000 hours and luminous output, for clear
prismatic lamps, above the following :
I. Compact Fluorescent Lamps: Single ended , 4-pin high efficiency compact lamp, operating
with electronic ballast. Guaranteed rated life shall be above 10000 hours and luminous
output above the following:
J. High Pressure Mercury Vapor Lamps: To IEC 60188, and to include quartz discharge tube
in an internally coated ovoid outer tube . Coating shall be yttrium vanadate phosphor with
color temperature of 3300 deg. K. Guaranteed rated life shall be above 16000 hours and
luminous output above the fo llowing:
K. High Pressure Sod ium Lamps : Type SON- T (tubular), with guaranteed average rated life
(down to 80% output) above 24000 hours, and having initial luminous output above the
follow ing:
L. Metal Halide Lamps up to 150 W : Si ng le ended, compact ceramic metal-halide lamp, high
efficiency with stable color over life time and exce llent color rendering characteristics with
UV fi lter quartz and 2-pin base [G8.5 , Gl2 or GU6.5]. Lamps shall be to IEC 61167.
Guaranteed average li fe shall not be less than 10000 hours and luminous outputs, after 100
hours burning, shall be above the following:
M. Metal Halide Lamps above 150 W: Comprising quartz di scharge tube enclosed in clear
tubular hard-glass outer bulb, operating on same principle as all gas discharge tubes with
iodide additives indium , thal lium and sodium in the mercury discharge, to increase intensity
in three spectral bands ; blue, green and yellow-red with stable color over time and high
color re ndering with UV filter quartz .. Lamps shall be to IEC 61 167 with E40 base.
Guaranteed average life shall not be less than 6000 hours and luminous outputs, after I 00
hours burning, shall be above the following :
Perm issible base temperature shall be not greater than 250 deg. C, and maximum bulb
temperature not greater than 550 deg. C. Lamp burning position for 2000 W, [230] V lamps
shall be possible up to 75 degrees.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Generally: Install fixtures leve l, aligned and parallel or square to building lines and at
uni form he ights as shown on the Drawings or as approved by Engineer. Make final height
adjustment after installation .
B. Fixture Support: Provide fi xture and/or fixture outlet boxes with hangers, brackets and
flanged bolted fittings , as necessary , to support weight of fixture. Submit details of hangers
By Contractor etc. and method of fastening for approval. Rigidly secure fixtures mounted on outlet boxes
to fixture studs. Install hooks or extension pieces, when required , for proper installation.
Provide one point of support in addition to the outlet box fixt ure stud for individually
mounted fixtures longe r than 600 mm .
c. Remote Mounting of Ballasts: Distance between the ballast and fixture shall not exceed that
recommended by ballast manufacturer. Verify, with ball ast manufacturers, maximum
d istance between ballast and luminaire.
D. Stem Hangers : Provide two stem hangers for individually mounted pendant fixtures. Stems
shall have suspension ali gners and shall be of suitable length for suspending fixtures at
required height.
F. Solid Ce ilings: Coordinate dimensions of recesses in cei lings with exact fixture dimensions
and structural elements.
G. Continuous Rows: Arrange fixt ures so that individual fixture can be removed without
By Contractor dismantling remaining fixt ures . Provide minimum spacing between fixtures.
H. Cover Plates : Install cover plates over fixture outlet box or opening in ceiling or structure
when left unused .
I. Flush Recessed Fixtures: Install to completely eliminate light leakage within fixture and
between fixture and adjacent finished surface.
J. Ventilation: Keep ventilation channels free after fixture is installed, if required by the design
of the fixture . Ensure that the final circuit connection is adequately protected against heat
transfer from fixtures .
K. Earth metal frames as described in Div ision 26 Section "Grounding and Bonding".
L. Tightness: Ensure that enclosed fixtu res are reasonably insect/dust tight when installed, and
completely weather- proof for install ations subject to weather condit ions. Installation of
fitt ing and term ination of circuit wiring should not invalidate the ingress protection rating.
M. Lamps for Permanent Installation: Place new lamps in fixtures immediately prior to hand-
over and when instructed by Engineer. Lamps used for temporary service shall not be used
for final Iamping of fixtures.
N. Fixtures : Set level , plumb, and square with ceiling and walls, and secure according to
manufacturer's written instructions and approved submittal materials. Install lamps in each
fixture .
0. Support for Fixtures in or on Grid-Ty pe Suspended Ceilings: Use grid for support.
1. Install a minimum of four ceil ing support system rods or wires for each fixture .
Locate not more than 150 mm from fixture corners.
2. Support Clips: Fasten to fixtures and to ceiling grid members at or near each fixture
corner.
By Contractor
A. Visual In spection: Check neatness of install ation , uniformity of equipment and nameplates
etc.
C. Operation : Check lighting installations for operation including control and regulation
equipment.
D. Electrical Data: Measure power factor, current and voltage at start for installations with
discharge lamps.
E. Inspect each installed fixture for dam age. Replace damaged fixtures and components.
H. Tests : As follows :
I. Malfunctioning Fixtures and Components: Replace or repair, then retest. Repeat procedure
until units operate properly.
A. Burn-in all lamps that require specific aging period to operate properly, prior to occupancy
by Employer. Burn-in fl uorescent and compact fluorescent lamps intended to be dimmed,
for at least I 00 hours at full vo ltage.
A. Clean fixtures inte rnally and externally after install ation. Use methods and materials
recommended by manufacturer.
By Contractor
3.5 ADJUSTING
To : OAR AL- HANDASAH (SHAIR & PARTNERS) Attn. Mr. Ala'a Khallfa
2. SUBMITIAL DESCRIPTION:
Vision ElM
SUBUnTEOBY
/~
. " 0
f' .. ., ,' t l ..
,
HEIMM
Ahmad Alazizi
Dear Sir,
Best regards,
Ahmed S. EI-Halous
Dear Sirs,
With reference to the above me ntioned ma t erial subm ittal regarding the follow ing:
2. Alterna t ive lamps for types Ml, MlA, M2 , M2A & M3 Code B
• Final approval is subject to the approval for samples by site engineer.
Best regards
Magdi Maurice on beha lf of
Alaa Khalifa
From: Ahmed S. EI-Halous [mai lto :a. elhalous@visionem .net]
Sent: Monday, February 04, 2013 10:10 AM
To: Alaa Khalifa (Aiaa .Khalifa@darqroup.com )
Cc: Ahmed Ali Mohamed Harara; Abeer Mohamed EI-Kadry; Ahmed Mostafa; Jihad Kahil ; karim magdy; Magdi
Maurice; Tarek Za her ; Elhussein Ibrahim; Mohamed Elsayed ; Usama Hamad; Ahmad Mashhout; Hani Begermy;
Hisham Tahawi; Kefah A. Aldmour; Mohamed Abdel Ghany; Mohammed Ahmed Al i Rumman; Rezk Alemam Abdou
Subject: Masa ' a Ac Plant At Ajyad - Electrical Material submittal for Approval - MSA-AJ-MAT-251-13
Please find attached Letter Ref# MSA-AJ-MAT-251-13 for Electrical Material Submitta l for your review and approval
You sha ll receive the hard copy & t he soft co py through M r. Mohammed EI-Sayed (Vision Ca iro)
Best Regards,
Confidentiality & Disclaimer Note: This e-mail and any attachments thereto contain protected and confidential
information intended for the sole use of the addressee individual or organization. If you are not th e addressee or an
authorized agent for him/it, or if you have received this message by error please notify the sender immediately by
return ing the message, and delete this copy from your system without any illegal use.
The Dar Group shall not be liable for the improper or incomplete transmission of the information conta ined in this
communication nor for any delay in its receipt or damage to your system .
2
( 1'2)
~~·)l.o¥ ! i.S_...:.-
~ - ,.. ..... ."-t. .. · ....
.........- ..., r ·" ;.U. .r--
Date: 2 9101/2013
~ .. .,.......,,.,,s,.,.
lV\ _,-.._.J' f; ~ - ~ ... -"" 0 /Rel AZI 3L02
•• _,#1: ...,..St.l
~· slc:Ouud•h9nttrtg (:Om
... La......lt ut.s-dOsaudtltQttlng: com To : A dvanced Vision Company
Jeddah. KSA
---- ~vt _~..,.f' ·~~
-.w.
a!cd'•~ud•'tgl"IUn(l ecm Attn : E ng. A hmad Harara
Subject: Mas'a AC Plant at Ajyad
c·"l""t 1\r .,.-SL- Ref : MA S-MA-EL-Ll-039 Rev. OJ-Jan-2012
$1cdd~mOuualhOhl "0 com
cern
Dear Sir.
With reference to above mentioned p roject name and your technical
4--...t. _,_- A. " - -<Q
f~
.........
SASO
~
=-'
@
,.--.....-
~
ii: c@us
[......,,,.,!
.~:.;-...: ~...:.Ul'~....~ .
..;t.l l ~
... ...a.._
S'C. .aUC• tO"U•rg CO'"T'
U'tl·d4iJUJ(!o:o~;~h:or>g CO'"'
.\llade by LYRTO.V to be Voss le Sh1mbe complying the
www saucttu~rw'"g com
spec{fication. Changing the approved control gear due to approved
control gear no more available in SLC production line.
!V'/I tV'.: ,..-SU tlY' .. t"'\ ~
..,-su
1 ._,~
~,·,~'"'"' ....&.~...a
The delivei~V time i · vety long 16 - I 8 weeks and the minimum
S!edt~<.IG g._"VCO""
quantity to be ordered as a one bulk is 560 PCS.
~ .,.,._-. '11." - ~.w
1 v ''"'Af • '"!\ ~ _.,..,.
And the required capacitor i ·special and 11·e did not use it before in
stc:dkt!SOuuchhgt'lt ng com
our product.
O.,,_J.I~...ll
.~
~
~
·~-
,_,_
SASO 0
p
~
i£ c@us
~:r-- ~.......t.:;jJ~
~\:!1~
KING ABDUL AZIZ AWARD
FOR THE IDEAL FACTORY
Technical Data
THE PROJECT OF MAKKAH FIRST RING ROAD
(BID-2002)
TABLE OF CONTENT
TECHNICAL DATA
Page 1 of 2
THE PROJECT OF MAKKAH FIRST RING ROAD
(BID-2002)
TABLE OF CONTENT
TECHNICAL DATA
Page 2 of 2
TYPE E2
TYPE: E2
BEAMLITE
• High light output Beamlite can be used for a wide variety of interior
emergency lighting applications, particularly for
• Robust construction
warehouses and high ceiling commercial areas. The high
• Hinged front access door intensity light source provides efficient illumination of
• Multi-directional lamp heads long, narrow escape routes, but can also provide general
coverage of a specific area when aimed at 90° to each
• Weatherproof
p IP55 option
p
other, for such as critical task locations where higher
• EasiCheck™ central addressable self-test options illumination is required. Beamlite has keyhole slot screw
fixing holes and a hinged front access door providing
ease of installation, whilst the standard twin LED’s give
separate early warning of failure of each lamp, in
addition to mains and charging status. For wet or dusty
areas, a weatherproof version is available. 289
Emergency - Projectors
PHOTOMETRIC DATA
290 INSTALLATION NOTES
• Suitable for wall mounting
• Cable entry on rear and top
• Direct screw fixed with keyhole slots
• Weatherproof version drilled on site for fixing and entry holes Ø Ø
• Lamp heads swivel and tilt, locked in position by screws H
• Supplied complete with lamps
DIMENSIONS
L
D1 D2
2 x 55W
10 45° 7.2 14.5
D
15 45° 11.0 23.0
20 37° 15.5 31.0
L (mm) H (mm) D (mm) 25 34° 20.0 40.0
Standard 325 370 82 30 34° 24.0 48.0
Weatherproof 300 565 180 35 32° 28.5 57.0
40 32° 33.0 66.0
45 31° 37.0 74.0
50 31° 41.0 82.0
Notes:
1. Spacing achieves 1 lux min on centre line of escape route
CATALOGUE NUMBERS 2. Aiming angle at 4m height restricted by glare cut-off restriction
3. K factor of 0.55 and S factor of 0.8 have been applied
System Mode Duration Lamp Rating Cat. No. Weight (kg) 4. 2 x 55W spacing distances for mounting heights below 10M are same as for
2 x 21W unit.
Standard IP20 housing
Non-maintained 3 hour 2 x 21W BEN3 8.70
Emergency - Projectors
Also available with EasiCheck™ automatic testing functionality - see page 195 for system features
Contact our Technical Support and Application department for further details - 01302 303350
Weatherproof Beamlite
BEAMLITE
TYPE F1
TYPE: F1
3DFLILF7&:
7&:[7/':+)3.,7
7&:SFV0$67(57/':+)3HUIRUPHU
3DFLILF7&:LVDIXQFWLRQDOGXVWMHWVKRFNDQGYDQGDOSURRI
OXPLQDLUHDQGFDQDFFRPPRGDWHERWK7/'DQG7/PP
IOXRUHVFHQWODPSV7KHFRYHULVIL[HGWRWKHKRXVLQJE\PHDQVRIDQ
LQQRYDWLYHFRQFHSWXVLQJLQWHJUDWHGIL[LQJSRLQWVWRDYRLGH[WHUQDO
ORFNHUV7KHUHLVDFKRLFHRIGLIIHUHQWVWDQGDUGYHUVLRQVDYDLODEOH7KH
OXPLQDLUHFDQEHPRXQWHGLQGLYLGXDOO\RULQOLQHZLWKHDV\
FOLFN
LQVWDOODWLRQ)OH[LELOLW\LVHQVXUHGZLWKDFKRLFHRIIL[LQJSRLQWVDQG
GLIIHUHQWFDEOHHQWULHV7KH7&:FDQDOVREHVXVSHQGHGIURP
3KLOLSV77;OLJKWOLQHV\VWHPV
3URGXFWGDWD
* With Fuse
3DFLILF7&:
'LPHQVLRQDOGUDZLQJ
7&:[7/':+)3.,7
7&:[7/':+)3.,7
3KRWRPHWULFGDWD
7&:[7/':+)3
-XQH
GDWDVXEMHFWWRFKDQJH
2014, February 21
data subject to change
An energy-efficient
solution
HF-Performer III for TL-D lamps
Benefits
• The programmed start enables the lamp to be switched on and off
without reducing useful lamp life.
• DC emergency operation in line with IEC/EN 60598-2-22 luminaire
norms
• Smart power ensures constant light, irrespective of mains-voltage
fluctuations
• Suitable for luminaires in protection class I and, after testing, class II
• The universal connector Wago 251 offers the flexibility for
horizontal-manual or push-in robot wiring or vertical ALF-robot
wiring.
Features
• Robust design for 100,000 hours lifetime at Ta=50 ˚C and over
100,000 on/off switching operations on one lamp
• Programmed, flicker-free, pre-heated start (< 0.5 s) which allows the
lamp to be switched on and off without reducing useful lamp life
• Active power factor correction to ensure constant light, irrespective
of mains-voltage fluctuations
• The unit is protected against excessive mains voltage and incorrect
connections.
Application
• Used with movement-detection control systems like Philips
OccuPlus
• Indoor applications, such as office buildings, hospitals, supermarkets,
department stores, industrial premises and schools
• Class I outdoor applications, e.g. industrial premises and parking lots
HF-Performer III for TL-D lamps 2
Related products
Dimensional drawing
HF-P 118 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
B1
HF-P 118 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 218 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 218 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 3/418 TL-D III 220-240V 280.0 265.0 40.0 28.0 4.2
C1
50/60Hz IDC
HF-P 136 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 136 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
A1 50/60Hz IDC
HF-P 236 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 236 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 336 TL-D III 220-240V 280.0 265.0 40.0 28.0 4.2
50/60Hz IDC
HF-P 158 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 158 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
2014, February 21
data subject to change
HF-Performer III for TL-D lamps 3
General Characteristics
Order code Full product name Applica- Rated Rated Rated Line Line Housing Energy
tion Lamptype Number of Ballast- Voltage Frequency Efficiency
code Lamps Lamp Index
Power
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz III TL-D 1 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz III TL-D 1 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz III TL-D 2 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz III TL-D 2 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz III TL-D 3/4 piece 18 220-240 V 50/60 Hz L 280x40x28 A2 BAT
IDC
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz III TL-D 1 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz III TL-D 1 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz III TL-D 2 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz III TL-D 2 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz III TL-D 3 piece 36 220-240 V 50/60 Hz L 280x40x28 A2 BAT
IDC
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz III TL-D 1 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz III TL-D 1 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
Performance diagrams
Wiring data
1
2
1 3
HF 2
BALLAST 1 4
3
4 5
L 2 HF 6
N HF-P 3 BALLAST 7
13 L 8
BALLAST
12 4 N 9
11 5 10
6
1
2
HF-P 2 TL-D/TL5 (keep wires 1;2 & 5;6 short) 3
4
5
HF 6
BALLAST 7
L 8
N 9
10
2014, February 21
data subject to change
HF-Performer III for TL-D lamps 4
Order code Full product name Lamp Power on TL-D Order code Full product name Bal Lm Fac Emergency
operation
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz IDC 15.8
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz IDC 15.8
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz IDC 32.2
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz IDC 32.2
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz IDC 48.7/66.2
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz IDC 32.5
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz IDC 32.5
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz IDC 62.5
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz IDC 62.5
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz IDC 95
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz IDC 51.9
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz IDC 51.9
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
Specifications are subject to change without notice. Trademarks are the property of
Koninklijke Philips N.V. (Royal Philips) or their respective owners.
Efficient fluorescent
lighting with improved
color rendering
MASTER TL-D Super 80
Benefits
• Good color rendering
• Relatively high efficacy, both initially and during lamp lifetime, with
high lumen maintenance
• Create atmospheres from warm white to cool daylight
Features
• Highly efficient 3-band fluorescent coating
• High initial light output compared with standard colors
• Low mercury dose
• Can be used with conventional or electronic gear
• Higher efficacy is achieved with electronic gear
Application
• Suitable for use in a wide range of luminaires for TL-D fluorescent
lamps for 'human' applications such as schools, offices, shops, factory
halls etc.
MASTER TL-D Super 80 2
Related products
G13, T8
Dimensional drawing
2014, January 6
data subject to change
MASTER TL-D Super 80 3
Dimensional drawing
Order Full product name Cap- Bulb Life to Life to 10% Life to 10% Life to Life to 50% Life to 50% LSF EM LSF EM
code Base 10% fail fail 50% fail fail 2000h 4000h
failures Preheat Nonpreh failures Preheat Nonpreh Rated,3h Rated,3h
EM EL,3h EL,3h EM EL,3h EL,3h cycle cycle
927920082712 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/827 1SL
927920082723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/827 1SL
927920083023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/830 1SL
927920083069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/830 UNP
927920083523 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/835 1SL
927920084023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 1SL
927920084069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 UNP
927920084093 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 1SL
927920086544 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/865 1SL
927920582723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 97 %
30W/827 1SL
927920583023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/830 1SL
927920584023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/840 1SL
927920586514 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/865 1SL
927921082712 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/827 1SL
927921082723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/827 1SL
927921083023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/830 1SL
2014, January 6
data subject to change
MASTER TL-D Super 80 4
Order Full product name Cap- Bulb Life to Life to 10% Life to 10% Life to Life to 50% Life to 50% LSF EM LSF EM
code Base 10% fail fail 50% fail fail 2000h 4000h
failures Preheat Nonpreh failures Preheat Nonpreh Rated,3h Rated,3h
EM EL,3h EL,3h EM EL,3h EL,3h cycle cycle
927921083069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/830 UNP
927921083523 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/835 1SL
927921084023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/840 1SL
927921084069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/840 UNP
927921084093 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/840 1SL
927921086544 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/865 1SL
927922082712 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/827 1SL
927922082723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/827 1SL
927922083023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/830 1SL
927922083069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/830 UNP
927922083081 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/830 1SL
927922083523 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/835 1SL
927922084023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/840 1SL
927922084069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/840 UNP
927922084081 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/840 1SL
927922084093 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/840 1SL
927922086544 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/865 1SL
927922282714 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
15W/827 1SL
927922283014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
15W/830 1SL
927922284014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
15W/840 1SL
927922286514 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
15W/865 1SL
927922583014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
23W/830 1SL
927922584014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
23W/840 1SL
927922586514 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 10000 hr 99 % 99 %
23W/865 1SL
927923083014 MASTER TL-D Super 80 1m G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/830 1SL
927923084014 MASTER TL-D Super 80 1m G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/840 1SL
927923086514 MASTER TL-D Super 80 1m G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/865 1SL
927923583014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 97 %
38W/830 1SL
2014, January 6
data subject to change
TYPE F2
TYPE: F2
,PSDOD7%6
7%6[7/':+)&3,
7%6SFV0$67(57/':(OHFWURQLFKLJK
IUHTXHQF\+LJKJORVVPLUURUPDWWDOXPLQXPORXYHU
,PSDOD7%6LVDIXQFWLRQDOUHFHVVHGOXPLQDLUHIRURU7/'
IOXRUHVFHQWODPSV,WRIIHUVDZLGHUDQJHRIRSWLFVDVZHOODVD
SULVPDWLFSODWH7KHRSWLFVSODWHDUHILWWHGWRWKHKRXVLQJE\PHDQVRI
DFOLSIRUHDV\LQVWDOODWLRQDQGPDLQWHQDQFH$QH[WHUQDOFRQQHFWLRQ
V\VWHPHQDEOHVWKHPDLQVFRQQHFWLRQWREHPDGHZLWKRXWRSHQLQJWKH
OXPLQDLUH7KHOXPLQDLUHILWVLQYLVLEOHSURILOHFHLOLQJVDVVWDQGDUGDQG
XVLQJDFFHVVRULHVLQFRQFHDOHGDQGSODVWHUFHLOLQJV
3URGXFWGDWD
* With Fuse
,PSDOD7%6
'LPHQVLRQDOGUDZLQJ
7%6[7/':+)&3,
.RQLQNOLMNH3KLOLSV195R\DO3KLOLSV
$OOULJKWVUHVHUYHG
6SHFLILFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH7UDGHPDUNVDUHWKHSURSHUW\RI
.RQLQNOLMNH3KLOLSV195R\DO3KLOLSVRUWKHLUUHVSHFWLYHRZQHUV
ZZZSKLOLSVFRPOLJKWLQJ -DQXDU\
GDWDVXEMHFWWRFKDQJH
2014, February 21
data subject to change
An energy-efficient
solution
HF-Performer III for TL-D lamps
Benefits
• The programmed start enables the lamp to be switched on and off
without reducing useful lamp life.
• DC emergency operation in line with IEC/EN 60598-2-22 luminaire
norms
• Smart power ensures constant light, irrespective of mains-voltage
fluctuations
• Suitable for luminaires in protection class I and, after testing, class II
• The universal connector Wago 251 offers the flexibility for
horizontal-manual or push-in robot wiring or vertical ALF-robot
wiring.
Features
• Robust design for 100,000 hours lifetime at Ta=50 ˚C and over
100,000 on/off switching operations on one lamp
• Programmed, flicker-free, pre-heated start (< 0.5 s) which allows the
lamp to be switched on and off without reducing useful lamp life
• Active power factor correction to ensure constant light, irrespective
of mains-voltage fluctuations
• The unit is protected against excessive mains voltage and incorrect
connections.
Application
• Used with movement-detection control systems like Philips
OccuPlus
• Indoor applications, such as office buildings, hospitals, supermarkets,
department stores, industrial premises and schools
• Class I outdoor applications, e.g. industrial premises and parking lots
HF-Performer III for TL-D lamps 2
Related products
Dimensional drawing
HF-P 118 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
B1
HF-P 118 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 218 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 218 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 3/418 TL-D III 220-240V 280.0 265.0 40.0 28.0 4.2
C1
50/60Hz IDC
HF-P 136 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 136 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
A1 50/60Hz IDC
HF-P 236 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 236 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 336 TL-D III 220-240V 280.0 265.0 40.0 28.0 4.2
50/60Hz IDC
HF-P 158 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 158 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
2014, February 21
data subject to change
HF-Performer III for TL-D lamps 3
General Characteristics
Order code Full product name Applica- Rated Rated Rated Line Line Housing Energy
tion Lamptype Number of Ballast- Voltage Frequency Efficiency
code Lamps Lamp Index
Power
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz III TL-D 1 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz III TL-D 1 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz III TL-D 2 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz III TL-D 2 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz III TL-D 3/4 piece 18 220-240 V 50/60 Hz L 280x40x28 A2 BAT
IDC
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz III TL-D 1 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz III TL-D 1 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz III TL-D 2 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz III TL-D 2 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz III TL-D 3 piece 36 220-240 V 50/60 Hz L 280x40x28 A2 BAT
IDC
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz III TL-D 1 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz III TL-D 1 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
Performance diagrams
Wiring data
1
2
1 3
HF 2
BALLAST 1 4
3
4 5
L 2 HF 6
N HF-P 3 BALLAST 7
13 L 8
BALLAST
12 4 N 9
11 5 10
6
1
2
HF-P 2 TL-D/TL5 (keep wires 1;2 & 5;6 short) 3
4
5
HF 6
BALLAST 7
L 8
N 9
10
2014, February 21
data subject to change
HF-Performer III for TL-D lamps 4
Order code Full product name Lamp Power on TL-D Order code Full product name Bal Lm Fac Emergency
operation
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz IDC 15.8
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz IDC 15.8
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz IDC 32.2
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz IDC 32.2
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz IDC 48.7/66.2
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz IDC 32.5
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz IDC 32.5
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz IDC 62.5
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz IDC 62.5
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz IDC 95
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz IDC 51.9
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz IDC 51.9
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
Specifications are subject to change without notice. Trademarks are the property of
Koninklijke Philips N.V. (Royal Philips) or their respective owners.
Efficient fluorescent
lighting with improved
color rendering
MASTER TL-D Super 80
Benefits
• Good color rendering
• Relatively high efficacy, both initially and during lamp lifetime, with
high lumen maintenance
• Create atmospheres from warm white to cool daylight
Features
• Highly efficient 3-band fluorescent coating
• High initial light output compared with standard colors
• Low mercury dose
• Can be used with conventional or electronic gear
• Higher efficacy is achieved with electronic gear
Application
• Suitable for use in a wide range of luminaires for TL-D fluorescent
lamps for 'human' applications such as schools, offices, shops, factory
halls etc.
MASTER TL-D Super 80 2
Related products
G13, T8
Dimensional drawing
2014, January 6
data subject to change
MASTER TL-D Super 80 3
Dimensional drawing
Order Full product name Cap- Bulb Life to Life to 10% Life to 10% Life to Life to 50% Life to 50% LSF EM LSF EM
code Base 10% fail fail 50% fail fail 2000h 4000h
failures Preheat Nonpreh failures Preheat Nonpreh Rated,3h Rated,3h
EM EL,3h EL,3h EM EL,3h EL,3h cycle cycle
927920082712 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/827 1SL
927920082723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/827 1SL
927920083023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/830 1SL
927920083069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/830 UNP
927920083523 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/835 1SL
927920084023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 1SL
927920084069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 UNP
927920084093 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 1SL
927920086544 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/865 1SL
927920582723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 97 %
30W/827 1SL
927920583023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/830 1SL
927920584023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/840 1SL
927920586514 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/865 1SL
927921082712 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/827 1SL
927921082723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/827 1SL
927921083023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/830 1SL
2014, January 6
data subject to change
REFERENCE
6XSSOLHU 6$8',/,*+7,1*&2
0DQXIDFWXUHU 6$8',/,*+7,1*&2
0DGH 6$8',$5$%,$
&RQIRUPDQFH ,(&6$62
DESIGN
3URGXFWGHVFULSWLRQ 3HQGDQWRU6XUIDFH%UDFNHWHG0RXOGHG'XVWWLJKWDQG
J
3HQGDQWRU6XUIDFH%UDFNHWHG0RXOGHG'XVWWLJKWDQG
:DWHU-HWSURRI,QGRRURU2XWGRRU+HDY\'XW\
:DWHU-HWSURRI,QGRRURU2XWGRRU+HDY\'XW\
S \ \
,QGXVWULDO/('/XPLQDLUHZLWK7HPSHUHG)ODW*ODVV
,QGXVWULDO/('/XPLQDLUHZLWK7HPSHUHG)ODW*ODVV
&RYHULQ)UDPH
&RYHULQ)UDPH
$SSOLFDWLRQ ,GHDOIRUURRPVLHXWLOLW\PDFKLQHDQGVKRZHUDUHDV
LHODXQGU\ZDVKLQJ SDUNLQJLQGXVWULDOZRUNVKRSV
VODXJKWHUKRXVHVWXQQHOVXQGHUSDVVHV RWKHUWKDW
UHTXLUHVKLJKGHJUHHRISURWHFWLRQDJDLQVWGXVWDQGZDWHU
T
'HJUHHRISURWHFWLRQ ,3
,3
0DWHULDORIKRXVLQJ &DVLQJIUDPHDQGORFNLQJV\VWHPDUHPDGHRIH[WUXGHG
DOXP (3DUHPDGHRIGLHFDVWDOXP3UHWUHDWHG
SDLQWHG VWRYHHQDPHOHGLQJUD\FRORU
/LJKW&RQWUROOHU &OHDUWHPSHUHGIODWJODVV
0RXQWLQJ 3HQGDQWPWG6XVSHQGHGE\ZLUHVURGVRUFKDLQV
6XUIDFHEUDFNHWHGPRXQWHG
&DEOH(QWU\: (OHFWULFDOWHUPLQDOVDUHDYDLODEOHRXWVLGHWKHOXPLQDLUH
'LPHQVLRQVRIIL[WXUH 5HIHUHQFHFDWDORJXH-
ELECTRICAL
Benefits
• Long lasting product design, including LED technology, all requiring a
minimum maintenance.
Areas of application
• Industrial Shops, Underpasses, Tunnels, Basement Parking, and other
alike applications.
65
Mounting
Product List
Photometry Dimensions
90° 90°
80° 75
5 80°
75° 75°
15
150
50
60° 60°
22
225
30
300
00
45°
I [cd/10001n]
45°
30° 15° 0° 15° 30°
C180 ___________ C90 _ _ _ _ _ _ _ _
LED control gear
Linear / area fixed output
Product description
• Built-in LED control gear for LED
• Constant current LED control gear with 350 mA output current
• Output power 80 W
• Nominal lifetime of 50,000 h (at ta 50 °C with a failure rate max.
0.2 % per 1,000 h)
• 5-year guarantee
Properties
• Low-profile metal casing with white cover
• Type of protection IP20
Functions
• Overload protection
• Short circuit proof
• Suitable for emergency lighting units acc. to EN 50172
Technical data
Rated supply voltage 220 – 240 V
AC Voltage range 198 – 264 V
DC Voltage range 176 – 280 V
Mains frequency 0 / 50 / 60 Hz
Typ. rated current (at 230 V / 50 Hz / full load) 0.38 A
Ordering data
Mains current (at 220 V / 0 Hz / full load) 0.39 A
Type Article number Packaging carton Packaging pallet Weight per pc.
Leakage current (PE) < 0.2 mA
LCI 080/0350 I010 220-240 V 28000093 10 pc(s). 960 pc(s). 0.199 kg
Max. input power 89 W
Typ. efficiency (at 230 V / 50 Hz / full load) > 94.5 %
Typ. λ (at 230 V / 50 Hz / full load) 0.95
Output current ripple ± 30 %
Max. repetitive output peak current 478 mA
Max. non-repetitive output peak current 600 mA
Switch-on time 0.4 s
Turn off time (at 230 V / 50 Hz / full load) 0.1 s
Hold time1 10 ms
Operating temperature range ta -25 ... +50 °C
Max. casing temperature tc 75 °C
Dimensions LxWxH 280 x 30 x 21 mm
Hole spacing D 270 mm
Standards
EN 55015
EN 61000-3-2
EN 61000-3-3
EN 61347-1
EN 61347-2-13
EN 61547
EN 62384
Harmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in %
THD 3. 5. 7. 9. 11.
LCI 080/0350 I010 220-240 V < 10 <8 <4 <3 <3 <1
Wiring guidelines Wiring type and cross section Release of the wiring
• The secondary cables should be run separately The wiring can be in stranded wires with ferrules or Press down the “push button” and remove
from the mains connections and mains cables to solid from 0.5 – 1.5 mm². For perfect function of the cable from front.
ensure good EMC conditions the push-wire terminals (WAGO 250) the strip length
• The LED wiring should be kept as short as should be 8.5 – 9.5 mm.
possible to ensure good EMC. The recommended
secondary cable length is max. 2 m. wire preparation:
• The LED control gear does not have polarity rever- 0.5 – 1.5 mm²
sal protection on the secondary side.
LED modules that do not have polarity reversal
protection may be damaged if polarity is reversed.
8.5 – 9.5 mm
Circuit diagrams
1 +
–
3
4
+
–
1 +
–
3
4
+
–
LED’s have to be connected as shown above to work properly. It is possible to connect a different number of LED’s on two circuits (like on
top picture). The minimum power load has to be connected. Otherwise the LED control gear will switch off.
95.5 0.990
0.985
95.0
0.980
94.5
0.975
Efficiency [%]
Power factor
94.0 0.970
0.965
93.5
0.960
93.0
0.955
92.5 0.950
40 45 50 55 60 65 70 75 80 40 45 50 55 60 65 70 75 80
Load [W] Load [W]
90
80
70
Input power [W]
60
50
40
30
20
10
0
40 45 50 55 60 65 70 75 80
Load [W]
Product description
• Ideal for linear and panel lights
• LED system solution with outstanding system efficiency up to
118 lm/W, consisting of linear LED modules and dimmable
LED control gear LCAI 080/0350
• Efficiency of the module up to 131 lm/W
• High colour rendering index CRI > 80
• Small colour tolerance MacAdam 31
• Small luminous flux tolerances
• Colour temperatures 3,000 K, 4,000 K and 5,000 K
• Perfectly uniform light, even if several LED modules are used
6.1
together in a line
1.6
• Push terminals for quick and simple wiring of LED module to LED
module
• Simple installation (e.g. screws) 270
• Long lifetime: 50,000 hours 122.5 (73.75)
• 5-year system guarantee on the complete product
35
Technical data
Beam characteristic 120° Ø4
Ambient temperature ta -30 ... +55 °C
Typ. tp point 65 °C Ordering data
Risk group (EN 62471:2008) 0 Packaging Weight per
Type Article number Colour temperature
Type of protection IP00 carton pc.
Umodule STARK-LLE-G2-1250-830-CLA 28000140 3,000 K 200 pc(s). 0.045 kg
Umodule STARK-LLE-G2-1250-840-CLA 28000141 4,000 K 200 pc(s). 0.059 kg
È
Standards, page 3
Colour temperatures and tolerances, page 6
Type LCAI 080/0350 I010 LCI 080/0350 I010 LCAI 070/0300 I010
Ord. No. 86459392 86459366 86459201
Circuit series series series
Voltage on the module (typ.) 135 V 198 V 132 V 198 V 130 V 195 V
SELV No No No
assignable LED control gear
STARK LLE-1250 4 6 4 6 4 6
Type LCCI 016/0350 I010 LCI 035/0350 TEC SR LCI 020/0350 TEC SR
Ord. No. 86459213 87500193 87500187
Circuit – series –
Voltage on the module (typ.) 33 V 33 V 66 V 66 V 33 V 33 V
SELV Yes No No
assignable LED control gear
STARK LLE-1250 1 1 2 2 1 1
STARK LLE-1250 1 1 1 4
Standards
EN 62031
EN 62471
EN 61347-1
EN 61547
EN 55015
Key for photometric code, e. g. 830 / 339 The device / module contains components that are sensitive to electro-
static discharge and may only be installed in the factory and on site if
1st digit 2nd + 3rd digit 4th digit 5th digit 6th digit
appropriate EOS/ESD protection measures have been taken. No special
Lumen maintanance after 25%
measures need be taken for devices/modules with enclosed casings
Code CRI McAdams after of the lifetime (max.6000h)
(contact with the pc board not possible), just normal installation prac-
Colour temperature in McAdams 25% of the Code Remaining lumen tice. Please note the requirements set out in the document EOS / ESD
7 67 – 76 Kelvin x 100 initial lifetime 7 ≥ 70 % guidelines (Guideline_EOS_ESD.pdf) at:
8 77 – 86 (max.6000h) 8 ≥ 80 % http://www.tridonic.com/com/en/technical-data.asp
9 87 – ≥90 9 ≥ 90 %
Mounting instruction
The LED modules are mounted onto a heat sink with 2 screws per module.
In order not to damage the modules only rounded head screws and an
additional plastic flat washer should be used.
80000
70000
60000 Wiring
50000
40000
in out
30000
25 35 45 55 65 75 85 + –
tp temperature [°C]
110
300 mA Wiring examples
100 350 mA
L + – + – + – + –
+
90 N –
Light output [%]
80
Uconverter
LCAI 80 W 350 mA
70
60
Wiring type and cross section
50
0 20000 40000 60000 80000 100000 The wiring can be solid cable with a cross section of
Lifetime [h] at tp = 65 °C
0.2 to 0.75 mm². For the push-wire connection you
have to strip the insulation (6–7 mm).
wire preparation:
Selection of the LED control gear 0.2 – 0.75 mm²
umodule STARK LLE can be operated either from SELV LED control gears or
from LED control gears with LV output voltage.
6 – 7 mm
umodule STARK LLE are basic isolated against ground and can be
mounted directly on earthed metal parts of the luminaire also when used
Inserting stranded wires / removing wires by lightly pressing on the push button.
in conjunction with the LED control gear LCAI 080/0350. In this case the
light emitting side of the module has to be protected against direct touch
(test finger). This is typically achieved by means of a non removable light
distributor over the module.
225 110
200
100
175
150
90
125
100
80
75
50 70
25 35 45 55 65 75 85
25 tc [°C]
0
0 100 200 300 400 500 600
Operating current [mA]
The optical design of the umodule STARK LLE product line ensures optimum
homogenity for the light distribution.
Light distribution
-10° 0° 10° The colour temperature is measured integral over the complete module.
-20° 20°
The single LED light points can have deviations in the colour coordinates
-30° 30°
100 within MacAdam 7.
-40° 40° To ensure an ideal mixture of colours and a homogenious light distribution
80 a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between
relative intensity Iv/Iv, max
-50° 50°
module and optic (typ. 6 cm) should be used.
60 -60° 60°
40 70°
20 80°
0 90°
-100 -80 -60 -40 -20 0 20 40 60 80 100
For further information see Design-in Guide, 3D data and photometric data on
www.tridonic.com or on request.
The specified colour coordinates are measured by a current impulse with typical values of module and a duration of 100 ms.
The ambient temperature of the measurement is ta = 25 °C.
The measurement tolerance of the colour coordinates are ± 0.01.
3,000 K
x0 y0
Centre 0,4344 0,4032
0,4250
100
0,4200
0,4150 80
0,4000 40
0,3950
20
0,3900
0,3850
0
0,4200
0,4250
0,4300
0,4350
0,4400
0,4450
0,4500
0,4550
0,4150
380 420 460 500 540 580 620 660 700 740 780
wave length [nm]
MacAdam Ellipse: 3SDCM
4,000 K
x0 y0
Mittelpunkt 0,3828 0,3803
0,4000
100
0,3950
0,3900
80
norm. intensity [%]
0,3850
60
0,3800
0,3750 40
0,3700
20
0,3650
0,3600 0
0,3850
0,3650
0,3700
0,3750
0,3800
0,3900
0,3950
0,4000
0,3600
380 420 460 500 540 580 620 660 700 740 780
wave length [nm]
MacAdam Ellipse: 3SDCM
REFERENCE
DESIGN
1: Product description : Roadway luminaire
: Application : Roadway or industrial , outdoors
: Color : Gray
8: Degree of protection : IP 65 (dust tight and water jet proof)
: Material of housing : Aluminum
: Housing fabrication : Extruded aluminum anodized, end cover are die-cast
aluminum secured to housing by screws and sealed
: Glass cover : Frosted tempered glass
4: Reflector : Symmetrical rollformed specular hammered finish
aluminum
: Mounting options : Semi-recess mounted
: Accessory : With external fuse terminal.
: Cable entry : 21.0mm dia. hole each end of housing with glands
: Cable connection : Socket & plug Terminal 3-pole, with connection for
grounding
: Dimensions of fixture : Reference catalogue UP201
ELECTRICAL
2: Light source : 400 watts metal halide tubular lamp
: Lamp holder : E 40
3: Voltage rating & circuitry : 230V/60Hz, reactor
: Voltage fluctuation allowable : ± 10%
: Ballast construction : Electromagnetic, IEC 922, 923
: Emergency unit, EM : n/a
: Input power : 425 watts
: Power factor : HPF, >0.90
: Line current : 2.15 A
: EM unit nominal charge current : n/a
: Internal wiring : 1.0 mm sq., solid copper wire 150°C
Cable Entry Cable entry through PG13.5 cable gland at the side of the luminaire.
130 B
Lamps 18,36 W & 58W - T8 Fluorescent lamp, switch start or electronic start.
17,32 W & 40W - T8 Flourescent lamp, electronic start.
PHOTOMETRY
A
2-150W max. Metal Halide Elliptical Lamp.
I [cd/10001m]
3- 400W max. Metal Halide Tubular Lamp.
4- 150W max. High Pressure Sodium Elliptical Lamp.
5- 400W max. High Pressure Sodium Tubular Lamp.
105° 120° 150°
50
50°
50
0°
150° 120° 105° MOUNTING SYSTEM
6- 180W max. Low Pressure Sodium Tubular Lamp. 90° 90°
Other lamp sources available on request. 80°
80°
10
00°
0 0
75° 75°
Voltage 120, 220, 240 or 227 VAC, 50/60 Hz.
Other voltage and Frequency upon request. 20
200
00°
0 0
60° 60°
Control Gear 30
300
00°
0 0
High Power Factor
40
400
00°
0 0
Ligh Controller GL-Clear, plain tempered flat glass in frame. 45° 45°
SA- Symmetrically roll formed alum. reflector, hammered pattern specular finish. 30° 15° 0° 15° 30°
GF- Clear, frosted tempered flat glass in frame.
AA- Asymmetrically formed alum. reflector, hammered pattern specular finish.
SA3-Symmetrically roll formed alum. reflector, plain pattern specular finish. C180 ___________ C0 ___________ CEILING MOUNTED SEMI RECESSED MOUNTED WALL MOUNTED PENDANT MOUNTED
C270 _ _ _ _ _ _ _ _ C90 _ _ _ _ _ _ _ _
J
ADDITIONAL ACCESSORIES Section: U J
49 50
TECHNICAL DATA SHEET
Ballasts for discharge lamps
Technical data:
ELECTRICAL DATA TEMPERATURE
Normative
A 137 mm
B 123 mm
C 86.6 mm
D 73 mm
Remarks: FT240631000
Product Dept.
09/07/12
The use of this document out of theCompany is not controlled. Technical data subject to change without warning.
Metal halide lamps
T tubular, E40 base, for enclosed luminaires
Quartz technology
2 up to 400 W
Product Product
reference number
POWERSTAR® HQI®-T
Benefits
• Output of up to 400 W
• Different light colours
• Also available in BLUE, GREEN and MAGENTA
• UV FILTER technology (see 5.04)
1) Operate with NAV® control gear. If operated with HQI® control gear see 5.15
“Technical data” from page 5.37
2) Lamps with virtually monochromatic light
E06./E02.***
TYPE A
250V
Optional
For parallel compensation of fluorescent lamps
Für die Parallelkompensation von Leuchtstofflampen
discharge resistor Entladewiderstand < 50V in 60 sec. option without temperature fuse
CN tolerance Toleranz ±10% (optional ±5%) Option ohne Temperatursicherung
** capacitor surface_Kondensatoroberfläche
E02.XXX-XXXXXX
9 30 x 70 E06.C70-300900/220001 72/FB4
10 30 x 70 E06.C70-301000/220001 72/FB4
12 30 x 90 E06.C90-301200/220001 72/FB3
12 30 x 70 E06.C70-301200/220001 72/FB4
13.5 30 x 90 E06.C90-381300/220001 72/FB3
16 30 x 90 E06.C90-301600/220001 72/FB3
18 35 x 90 E06.D90-301810/220001 50/FB3
20 35 x 90 E06.D90-302010/220001 50/FB3
24 40 x 90 E06.E90-302410/220001 36/FB3
25 40 x 90 E06.E90-302510/220001 36/FB3
30 40 x 90 E02
E06.E90-303010/220001 36/FB3
32 35 x 135 E06.D35-403210/220001 50/FB1
32 45 x 90 E06.F90-403210/220001 32/FB1
40 45 x 90 E06.F90-404010/220001 32/FB1
50 45 x 135 E06.F35-405010/220001 32/FB1
55 45 x 135 E06.F35-405510/220001 32/FB1
8
AW
DESIGN AW
DESIGN AW
L ±2.5
Bechermaterial . . . . . . . . . . . . . . . . . . Aluminium
Füllmittel . . . . . . . . . . . . . . . . . . . . . . . ohne (trocken)
Einbaulage . . . . . . . . . . . . . . . . . . . . . . beliebig
Entladewiderstand . . . . . . . . . . . . . . . . intern
Imax (Anschlüsse) . . . . . . . . . . . . . . . . . . 10A
Schutzgrad . . . . . . . . . . . . . . . . . . . . . . IP 20
Feuchtegrad . . . . . . . . . . . . . . . . . . . . . . G
B Anschlüsse
Steckklemme . . . . . . . . . . . . . . . . . . WAGO
Bodenschraube . . . . . . . . . . . . . . . . . . . M8 × 10
D ±5 zul. Drehmoment . . . . . . . . . . . . . . . . . 5Nm
DIMENSIONAL DRAWINGS_MASSZEICHNUNGEN_AW
11
UP201R/3-250VPK.SA Product no.
REFERENCE
DESIGN
1: Product description : Roadway luminaire
: Application : Roadway or industrial , outdoors
: Color : Gray
8: Degree of protection : IP 65 (dust tight and water jet proof)
: Material of housing : Aluminum
: Housing fabrication : Extruded aluminum anodized, end cover are die-cast
aluminum secured to housing by screws and sealed
: Glass cover : Frosted tempered glass
4: Reflector : Symmetrical rollformed specular hammered finish
aluminum
: Mounting options : Semi-recess mounted
: Accessory : With external fuse terminal.
: Cable entry : 21.0mm dia. hole each end of housing with glands
: Cable connection : Socket & plug Terminal 3-pole, with connection for
grounding
: Dimensions of fixture : Reference catalogue UP201
ELECTRICAL
2: Light source : 250 watts metal halide tubular lamp
: Lamp type : High intensity discharge
: Lamp holder : E 40
3: Voltage rating & circuitry : 230V/60Hz, Reactor
: Voltage fluctuation allowable : ± 10%
: Ballast construction : Electromagnetic, IEC 922, 923
: Input power : 275 watts
: Power factor : HPF, >0.90
: Line current : 1.27 A
: Internal wiring : 1.0 mm² solid copper wire, 105°C
Cable Entry Cable entry through PG13.5 cable gland at the side of the luminaire.
130 B
Lamps 18,36 W & 58W - T8 Fluorescent lamp, switch start or electronic start.
17,32 W & 40W - T8 Flourescent lamp, electronic start.
PHOTOMETRY
A
2-150W max. Metal Halide Elliptical Lamp.
I [cd/10001m]
3- 400W max. Metal Halide Tubular Lamp.
4- 150W max. High Pressure Sodium Elliptical Lamp.
5- 400W max. High Pressure Sodium Tubular Lamp.
105° 120° 150°
50
50°
50
0°
150° 120° 105° MOUNTING SYSTEM
6- 180W max. Low Pressure Sodium Tubular Lamp. 90° 90°
Other lamp sources available on request. 80°
80°
10
00°
0 0
75° 75°
Voltage 120, 220, 240 or 227 VAC, 50/60 Hz.
Other voltage and Frequency upon request. 20
200
00°
0 0
60° 60°
Control Gear 30
300
00°
0 0
High Power Factor
40
400
00°
0 0
Ligh Controller GL-Clear, plain tempered flat glass in frame. 45° 45°
SA- Symmetrically roll formed alum. reflector, hammered pattern specular finish. 30° 15° 0° 15° 30°
GF- Clear, frosted tempered flat glass in frame.
AA- Asymmetrically formed alum. reflector, hammered pattern specular finish.
SA3-Symmetrically roll formed alum. reflector, plain pattern specular finish. C180 ___________ C0 ___________ CEILING MOUNTED SEMI RECESSED MOUNTED WALL MOUNTED PENDANT MOUNTED
C270 _ _ _ _ _ _ _ _ C90 _ _ _ _ _ _ _ _
J
ADDITIONAL ACCESSORIES Section: U J
49 50
TECHNICAL DATA SHEET
Ballasts for discharge lamps
Technical data:
ELECTRICAL DATA TEMPERATURE
Normative
A 127 mm
B 113 mm
C 86.6 mm
D 73.2 mm
Remarks: FT425721000
Product Dept.
29/06/12
The use of this document out of theCompany is not controlled. Technical data subject to change without warning.
Metal halide lamps
T tubular, E40 base, for enclosed luminaires
Quartz technology
2 up to 400 W
Product Product
reference number
POWERSTAR® HQI®-T
Benefits
• Output of up to 400 W
• Different light colours
• Also available in BLUE, GREEN and MAGENTA
• UV FILTER technology (see 5.04)
1) Operate with NAV® control gear. If operated with HQI® control gear see 5.15
“Technical data” from page 5.37
2) Lamps with virtually monochromatic light
E06./E02.***
TYPE A
250V
Optional
For parallel compensation of fluorescent lamps
Für die Parallelkompensation von Leuchtstofflampen
discharge resistor Entladewiderstand < 50V in 60 sec. option without temperature fuse
CN tolerance Toleranz ±10% (optional ±5%) Option ohne Temperatursicherung
** capacitor surface_Kondensatoroberfläche
E02.XXX-XXXXXX
9 30 x 70 E06.C70-300900/220001 72/FB4
10 30 x 70 E06.C70-301000/220001 72/FB4
12 30 x 90 E06.C90-301200/220001 72/FB3
12 30 x 70 E06.C70-301200/220001 72/FB4
13.5 30 x 90 E06.C90-381300/220001 72/FB3
16 30 x 90 E06.C90-301600/220001 72/FB3
18 35 x 90 E06.D90-301810/220001 50/FB3
20 35 x 90 E06.D90-302010/220001 50/FB3
24 40 x 90 E06.E90-302410/220001 36/FB3
25 40 x 90 E02
E06.E90-302510/220001 36/FB3
30 40 x 90 E06.E90-303010/220001 36/FB3
32 35 x 135 E06.D35-403210/220001 50/FB1
32 45 x 90 E06.F90-403210/220001 32/FB1
40 45 x 90 E06.F90-404010/220001 32/FB1
50 45 x 135 E06.F35-405010/220001 32/FB1
55 45 x 135 E06.F35-405510/220001 32/FB1
8
AW
DESIGN AW
DESIGN AW
L ±2.5
Bechermaterial . . . . . . . . . . . . . . . . . . Aluminium
Füllmittel . . . . . . . . . . . . . . . . . . . . . . . ohne (trocken)
Einbaulage . . . . . . . . . . . . . . . . . . . . . . beliebig
Entladewiderstand . . . . . . . . . . . . . . . . intern
Imax (Anschlüsse) . . . . . . . . . . . . . . . . . . 10A
Schutzgrad . . . . . . . . . . . . . . . . . . . . . . IP 20
Feuchtegrad . . . . . . . . . . . . . . . . . . . . . . G
B Anschlüsse
Steckklemme . . . . . . . . . . . . . . . . . . WAGO
Bodenschraube . . . . . . . . . . . . . . . . . . . M8 × 10
D ±5 zul. Drehmoment . . . . . . . . . . . . . . . . . 5Nm
DIMENSIONAL DRAWINGS_MASSZEICHNUNGEN_AW
11
UP201R/2-150VPK.SA Product no.
REFERENCE
DESIGN
1: Product description : Roadway luminaire
: Application : Roadway or industrial , outdoors
: Color : Gray
8: Degree of protection : IP 65 (dust tight and water jet proof)
: Material of housing : Aluminum
: Housing fabrication : Extruded aluminum anodized, end cover are die-cast
aluminum secured to housing by screws and sealed
: Glass cover : Frosted tempered glass
4: Reflector : Symmetrical rollformed specular hammered finish
aluminum
: Mounting options : Semi-recess mounted
: Accessory : With external fuse terminal.
: Cable entry : 21.0mm dia. hole each end of housing with glands
: Cable connection : Socket & plug Terminal 3-pole, with connection for
grounding
: Dimensions of fixture : Reference catalogue UP201
ELECTRICAL
2: Light source : 150 watts metal halide elliptical lamp
: Lamp type : High intensity discharge
: Lamp holder : E 27
3: Voltage rating & gear type : 230V/60Hz, reactor
: Voltage fluctuation : ± 10 %
: Ballast construction : Electromagnetic, IEC 922, 923
: Input power : 167 watts
: Power factor : HPF, >0.90
: Line current : 0.84 A
: Internal wiring : 1.0 mm² stranded copper wire, 150°C
Cable Entry Cable entry through PG13.5 cable gland at the side of the luminaire.
130 B
Lamps 18,36 W & 58W - T8 Fluorescent lamp, switch start or electronic start.
17,32 W & 40W - T8 Flourescent lamp, electronic start.
PHOTOMETRY
A
2-150W max. Metal Halide Elliptical Lamp.
I [cd/10001m]
3- 400W max. Metal Halide Tubular Lamp.
4- 150W max. High Pressure Sodium Elliptical Lamp.
5- 400W max. High Pressure Sodium Tubular Lamp.
105° 120° 150°
50
50°
50
0°
150° 120° 105° MOUNTING SYSTEM
6- 180W max. Low Pressure Sodium Tubular Lamp. 90° 90°
Other lamp sources available on request. 80°
80°
10
00°
0 0
75° 75°
Voltage 120, 220, 240 or 227 VAC, 50/60 Hz.
Other voltage and Frequency upon request. 20
200
00°
0 0
60° 60°
Control Gear 30
300
00°
0 0
High Power Factor
40
400
00°
0 0
Ligh Controller GL-Clear, plain tempered flat glass in frame. 45° 45°
SA- Symmetrically roll formed alum. reflector, hammered pattern specular finish. 30° 15° 0° 15° 30°
GF- Clear, frosted tempered flat glass in frame.
AA- Asymmetrically formed alum. reflector, hammered pattern specular finish.
SA3-Symmetrically roll formed alum. reflector, plain pattern specular finish. C180 ___________ C0 ___________ CEILING MOUNTED SEMI RECESSED MOUNTED WALL MOUNTED PENDANT MOUNTED
C270 _ _ _ _ _ _ _ _ C90 _ _ _ _ _ _ _ _
J
ADDITIONAL ACCESSORIES Section: U J
49 50
TECHNICAL DATA SHEET
Ballasts for discharge lamps
Technical data:
ELECTRICAL DATA TEMPERATURE
Normative
A 135.3 mm
B 121.3 mm
C 65 mm
D 52.3 mm
E 116.3 mm
Weight 2050 grs.
Remarks: FT415720000
Product Dept.
The use of this document out of theCompany is not controlled. Technical data subject to change without warning.
06/03/12
Metal halide lamps
E elliptical, E27/E40 base, for open luminaires
Quartz technology
1 2
Product Product
reference number
Benefits Comments
• E27 or E40 screw base for simple lamp handling • NAV® 100 W chokes and HQI® 150 W igniters are
• Different light colours suitable for operating HQI®-E 100 W lamps.
• Available in clear and coated versions
• UV FILTER technology (see 5.04)
1) Reduced colour shift over lifetime, but has a faster loss of luminous flux. 2) Operate with NAV® control gear. If operated with HQI® control 5.19
This may be offset by a lower maintenance factor gear see “Technical data” from page 5.37
E06./E02.***
TYPE A
250V
Optional
For parallel compensation of fluorescent lamps
Für die Parallelkompensation von Leuchtstofflampen
discharge resistor Entladewiderstand < 50V in 60 sec. option without temperature fuse
CN tolerance Toleranz ±10% (optional ±5%) Option ohne Temperatursicherung
** capacitor surface_Kondensatoroberfläche
E02.XXX-XXXXXX
9 30 x 70 E06.C70-300900/220001 72/FB4
10 30 x 70 E06.C70-301000/220001 72/FB4
12 30 x 90 E06.C90-301200/220001 72/FB3
12 30 x 70 E06.C70-301200/220001 72/FB4
13.5 30 x 90 E06.C90-381300/220001 72/FB3
16 30 x 90 E02
E06.C90-301600/220001 72/FB3
18 35 x 90 E06.D90-301810/220001 50/FB3
20 35 x 90 E06.D90-302010/220001 50/FB3
24 40 x 90 E06.E90-302410/220001 36/FB3
25 40 x 90 E06.E90-302510/220001 36/FB3
30 40 x 90 E06.E90-303010/220001 36/FB3
32 35 x 135 E06.D35-403210/220001 50/FB1
32 45 x 90 E06.F90-403210/220001 32/FB1
40 45 x 90 E06.F90-404010/220001 32/FB1
50 45 x 135 E06.F35-405010/220001 32/FB1
55 45 x 135 E06.F35-405510/220001 32/FB1
8
AW
DESIGN AW
DESIGN AW
L ±2.5
Bechermaterial . . . . . . . . . . . . . . . . . . Aluminium
Füllmittel . . . . . . . . . . . . . . . . . . . . . . . ohne (trocken)
Einbaulage . . . . . . . . . . . . . . . . . . . . . . beliebig
Entladewiderstand . . . . . . . . . . . . . . . . intern
Imax (Anschlüsse) . . . . . . . . . . . . . . . . . . 10A
Schutzgrad . . . . . . . . . . . . . . . . . . . . . . IP 20
Feuchtegrad . . . . . . . . . . . . . . . . . . . . . . G
B Anschlüsse
Steckklemme . . . . . . . . . . . . . . . . . . WAGO
Bodenschraube . . . . . . . . . . . . . . . . . . . M8 × 10
D ±5 zul. Drehmoment . . . . . . . . . . . . . . . . . 5Nm
DIMENSIONAL DRAWINGS_MASSZEICHNUNGEN_AW
11
TYPE M1
ECO-824
PRODUCT IDENTIFICATION
Product ECO-824
Functional Cabled tunnel stud
Characteristics
CHARACTERISTICS
Advantages Project for tunnel illumination
Robust construction
Easy replacement
Low maintenance
Waterproof
MECHANICAL CHARACTERISTICS
Dimensions See below
(mm)
Bottom Part Aluminum
Material
Fixation 2
points
Screws M5x25mm / M5x20mm
Prepare and install the edge (100mmx30mm) in the wall that will be
illuminated
BEAMLITE
• High light output Beamlite can be used for a wide variety of interior
emergency lighting applications, particularly for
• Robust construction
warehouses and high ceiling commercial areas. The high
• Hinged front access door intensity light source provides efficient illumination of
• Multi-directional lamp heads long, narrow escape routes, but can also provide general
coverage of a specific area when aimed at 90° to each
• Weatherproof
p IP55 option
p
other, for such as critical task locations where higher
• EasiCheck™ central addressable self-test options illumination is required. Beamlite has keyhole slot screw
fixing holes and a hinged front access door providing
ease of installation, whilst the standard twin LED’s give
separate early warning of failure of each lamp, in
addition to mains and charging status. For wet or dusty
areas, a weatherproof version is available. 289
Emergency - Projectors
PHOTOMETRIC DATA
290 INSTALLATION NOTES
• Suitable for wall mounting
• Cable entry on rear and top
• Direct screw fixed with keyhole slots
• Weatherproof version drilled on site for fixing and entry holes Ø Ø
• Lamp heads swivel and tilt, locked in position by screws H
• Supplied complete with lamps
DIMENSIONS
L
D1 D2
2 x 55W
10 45° 7.2 14.5
D
15 45° 11.0 23.0
20 37° 15.5 31.0
L (mm) H (mm) D (mm) 25 34° 20.0 40.0
Standard 325 370 82 30 34° 24.0 48.0
Weatherproof 300 565 180 35 32° 28.5 57.0
40 32° 33.0 66.0
45 31° 37.0 74.0
50 31° 41.0 82.0
Notes:
1. Spacing achieves 1 lux min on centre line of escape route
CATALOGUE NUMBERS 2. Aiming angle at 4m height restricted by glare cut-off restriction
3. K factor of 0.55 and S factor of 0.8 have been applied
System Mode Duration Lamp Rating Cat. No. Weight (kg) 4. 2 x 55W spacing distances for mounting heights below 10M are same as for
2 x 21W unit.
Standard IP20 housing
Non-maintained 3 hour 2 x 21W BEN3 8.70
Emergency - Projectors
Also available with EasiCheck™ automatic testing functionality - see page 195 for system features
Contact our Technical Support and Application department for further details - 01302 303350
Weatherproof Beamlite
BEAMLITE
Note : Type HM has been Changed from flood light of high mast to street lighting to
reduce the glare and to improve the uniformity as per submitted lighting calculation.
GENERAL
DESIGN
1: Product description : Semi cut-off roadway lighting fixture
: Application : Major roads and highways
: Color : Gray
8: Degree of protection : IP 54 ( dust proof & water splash proof)
: Material of housing : Body is extruded aluminum & die-cast aluminum
end covers.
: Optical : Reflector is made of anodized aluminum,
glass frame is made of die-cast aluminum and clear
curved tempered glass
: Mounting : Bracket mounted on high mast.
: Accessory : n/a
: Cable entry : Wiring access through gear compartment
: Cable connection : Terminal block, 3-pole, screw type with grounding
: Overall dimension of fixture : Refer to attached catalogue XP201
ELECTRICAL
2: Light source : 1000 W high pressure sodium tubular lamp
: Lamp type : High intensity discharge
: Lamp holder : E 40
3: Voltage rating & gear type : 230V/60Hz, reactor
: Voltage fluctuation allowable : ± 10 %
: Ballast construction : Electromagnetic , IEC 922, 923
: Input power : 1056 watts
: Power factor : HPF, 0.90
: Line current : 5.33 A
: Internal wiring : 1.5 mm sq., stranded Cu., wire, 180C
Mounting C1
High mast Mounting ( HM, HMB ) C C 103
Post Side Mounting ( PS, Q, QA, QB, QBA) A
Cable Entry Supplied with quick disconnect plug and socket for 2.5mm
PHOTOMETRY XP201HM XP201Q XP201HMB XP201HM
103
B B B A
2 supply cable.
I [cd/10001m]
C1 XP201Q
C1
Lamps 2-400W max. Metal Halide Elliptical Lamp. 120° 150° 150° 120° C
105° 1
105°
50
50°
50
0°
3-1000W max. Metal Halide Tubular Lamp. XP201PS / XP201QA XP201QBA XP201QB
90°° 9
90°
XP201PS / XP201QA
5-1000W max. High Pressure Sodium Tubular Lamp.
Other lamp sources available on request. 75°
75°°
300
30
00°
0
6
60° MOUNTING SYSTEM
Voltage 120, 220, 240, 227 VAC, 50/60 Hz. 45
450
50°
5 0
Other Voltage and Frequency upon request. 60°° 4
45° Ø60.3
600
60
00°
0
J
ADDITIONAL ACCESSORIES Section: U J
51 52
TECHNICAL DATA SHEET
Ballasts for discharge lamps
Technical data:
ELECTRICAL DATA TEMPERATURE
Normative
Weight: 7.95Kg
Packing units: 2
Remarks: FT490633000
Product Dept.
The use of this document out of theCompany is not controlled. Technical data subject to change without warning. 10/09/13
High-pressure sodium vapour lamps
T tubular, clear
Product Product
reference number
NAV® as a clear tubular lamp PLANTASTAR® 400 W and 600 W lamps were
Clear tubular NAV® lamps enable light to be directed developed specifically for applications in commercial
with great precision. For new street light installations, horticulture. They enable plants to be intensively
this means that mast spacing can be greater. This cultivated throughout the year.
applies in particular to NAV®-T Super 4Y® lamps with
their extremely high luminous efficacy. Potential
savings are considerable.
The other product characteristics and possible
applications are as described in previous pages.
Approval marks
Rated values
Rated capacitance 45.0 µF
Tolerance of capacitance ± 10 %
Rated voltage 250 V~
Rated frequency 50/60 Hz
Temperature range -40 °C to +85 °C
Type (protection class) A
Test class 40/85/10 (IEC 68)
Limit values of relative humidity Class G acc. to DIN 40 040
65% annual means
85% maximum value on 30 days
75% on all others days
Condensation not permitted
Test voltage
between terminals (2.15 · UN) V~
between terminals and case 3,000 V~
Construction
Terminal push-wire terminal with
integrated discharge resistor
Case aluminum
with base mounting stud (DIN 40011)
washer (DIN 6797) ø 8.4 enclosed
nut (DIN 439) M8 enclosed
max. fixing torque 5.0 Nm
Dimensions
Diameter D = 50 mm
Length L = 95 mm
Base mounting stud B: M 8 x 10 mm
We reserve the right to make technical changes without prior notice. No liability can be assumed for the accuracy of data content.
©2010 ELECTRONICON Kondensatoren GmbH, Keplerstrasse 2, 07549 Gera, Germany Date: 2010-11-19
Fon: +49 365 7346-100, Fax: -110, email: research@electronicon.com
Sign: EE3-JG-PRE
E06./E02.***
TYPE A
250V
Optional
For parallel compensation of fluorescent lamps
Für die Parallelkompensation von Leuchtstofflampen
discharge resistor Entladewiderstand < 50V in 60 sec. option without temperature fuse
CN tolerance Toleranz ±10% (optional ±5%) Option ohne Temperatursicherung
** capacitor surface_Kondensatoroberfläche
E02.XXX-XXXXXX
9 30 x 70 E06.C70-300900/220001 72/FB4
10 30 x 70 E06.C70-301000/220001 72/FB4
12 30 x 90 E06.C90-301200/220001 72/FB3
12 30 x 70 E06.C70-301200/220001 72/FB4
13.5 30 x 90 E06.C90-381300/220001 72/FB3
16 30 x 90 E06.C90-301600/220001 72/FB3
18 35 x 90 E06.D90-301810/220001 50/FB3
20 35 x 90 E06.D90-302010/220001 50/FB3
24 40 x 90 E06.E90-302410/220001 36/FB3
25 40 x 90 E06.E90-302510/220001 36/FB3
30 40 x 90 E06.E90-303010/220001 36/FB3
32 35 x 135 E06.D35-403210/220001 50/FB1
32 45 x 90 E06.F90-403210/220001 32/FB1
40 45 x 90 E02
E06.F90-404010/220001 32/FB1
50 45 x 135 E06.F35-405010/220001 32/FB1
55 45 x 135 E06.F35-405510/220001 32/FB1
8
AW
DESIGN AW
DESIGN AW
L ±2.5
Bechermaterial . . . . . . . . . . . . . . . . . . Aluminium
Füllmittel . . . . . . . . . . . . . . . . . . . . . . . ohne (trocken)
Einbaulage . . . . . . . . . . . . . . . . . . . . . . beliebig
Entladewiderstand . . . . . . . . . . . . . . . . intern
Imax (Anschlüsse) . . . . . . . . . . . . . . . . . . 10A
Schutzgrad . . . . . . . . . . . . . . . . . . . . . . IP 20
Feuchtegrad . . . . . . . . . . . . . . . . . . . . . . G
B Anschlüsse
Steckklemme . . . . . . . . . . . . . . . . . . WAGO
Bodenschraube . . . . . . . . . . . . . . . . . . . M8 × 10
D ±5 zul. Drehmoment . . . . . . . . . . . . . . . . . 5Nm
DIMENSIONAL DRAWINGS_MASSZEICHNUNGEN_AW
11
7435E/5-150VPK.2A.FU Product no.
REFERENCE
ELECTRICAL
2: Light source : 150 watts high pressure sodium tubular lamp
: Lamp type : High intensity discharge
: Lamp holder : E 40
3: Voltage rating & gear type : 230V/60Hz , reactor
: Voltage fluctuation allowable : ± 10 %
: Ballast construction : Electromagnetic, IEC 922, 923
: Input power : 168.5 watts
: Power factor : HPF, >0.90
: Line current : 0.85 A
: Internal wiring : 1.0 mm sq. stranded copper wire, 150°C
30° 15° 0° 15° 30° POST SIDE MOUNTING POST TOP MOUNTING
Light Controller GC-Clear, formed, plain tempered glass.
SA-Symmetrically formed alum.reflector,semi-specular finish. C180 ___________ C0 ____________
C270 _ _ _ _ _ _ _ _ C90 _ _ _ _ _ _ _ _
J
ADDITIONAL ACCESSORIES Section: U J
23 24
TECHNICAL DATA SHEET
Ballasts for discharge lamps
Technical data:
ELECTRICAL DATA TEMPERATURE
Normative
A 135.3 mm
B 121.3 mm
C 65 mm
D 52.3 mm
E 116.3 mm
Weight 2050 grs.
Remarks: FT415720000
Product Dept.
The use of this document out of theCompany is not controlled. Technical data subject to change without warning.
06/03/12
High-pressure sodium vapour lamps
T tubular, clear
Product Product
reference number
NAV® as a clear tubular lamp PLANTASTAR® 400 W and 600 W lamps were
Clear tubular NAV® lamps enable light to be directed developed specifically for applications in commercial
with great precision. For new street light installations, horticulture. They enable plants to be intensively
this means that mast spacing can be greater. This cultivated throughout the year.
applies in particular to NAV®-T Super 4Y® lamps with
their extremely high luminous efficacy. Potential
savings are considerable.
The other product characteristics and possible
applications are as described in previous pages.
Optional
For parallel compensation of fluorescent lamps
Für die Parallelkompensation von Leuchtstofflampen
discharge resistor Entladewiderstand < 50V in 60 sec. option without temperature fuse
CN tolerance Toleranz ±10% (optional ±5%) Option ohne Temperatursicherung
** capacitor surface_Kondensatoroberfläche
E02.XXX-XXXXXX
9 30 x 70 E06.C70-300900/220001 72/FB4
10 30 x 70 E06.C70-301000/220001 72/FB4
12 30 x 90 E06.C90-301200/220001 72/FB3
12 30 x 70 E06.C70-301200/220001 72/FB4
13.5 30 x 90 E06.C90-381300/220001 72/FB3
16 30 x 90 E02
E06.C90-301600/220001 72/FB3
18 35 x 90 E06.D90-301810/220001 50/FB3
20 35 x 90 E06.D90-302010/220001 50/FB3
24 40 x 90 E06.E90-302410/220001 36/FB3
25 40 x 90 E06.E90-302510/220001 36/FB3
30 40 x 90 E06.E90-303010/220001 36/FB3
32 35 x 135 E06.D35-403210/220001 50/FB1
32 45 x 90 E06.F90-403210/220001 32/FB1
40 45 x 90 E06.F90-404010/220001 32/FB1
50 45 x 135 E06.F35-405010/220001 32/FB1
55 45 x 135 E06.F35-405510/220001 32/FB1
8
AW
DESIGN AW
DESIGN AW
L ±2.5
Bechermaterial . . . . . . . . . . . . . . . . . . Aluminium
Füllmittel . . . . . . . . . . . . . . . . . . . . . . . ohne (trocken)
Einbaulage . . . . . . . . . . . . . . . . . . . . . . beliebig
Entladewiderstand . . . . . . . . . . . . . . . . intern
Imax (Anschlüsse) . . . . . . . . . . . . . . . . . . 10A
Schutzgrad . . . . . . . . . . . . . . . . . . . . . . IP 20
Feuchtegrad . . . . . . . . . . . . . . . . . . . . . . G
B Anschlüsse
Steckklemme . . . . . . . . . . . . . . . . . . WAGO
Bodenschraube . . . . . . . . . . . . . . . . . . . M8 × 10
D ±5 zul. Drehmoment . . . . . . . . . . . . . . . . . 5Nm
DIMENSIONAL DRAWINGS_MASSZEICHNUNGEN_AW
11
7435E/5-400VPX.2A.FU Product no.
REFERENCE
ELECTRICAL
2: Light source : 400 watts high pressure sodium tubular lamp
: Lamp type : High intensity discharge
4: Lamp holder : E 40, standard position
3: Voltage rating & gear type : 230V/60Hz, reactor
: Voltage fluctuation allowable : ± 10 %
: Ballast construction : Electromagnetic, IEC 60923
: Input power : 432 watts
: Power factor : HPF, >0.90
: Line current : 2.0 A
: Internal wiring : 1.0 mm² dia. stranded copper wire, 150°C
30° 15° 0° 15° 30° POST SIDE MOUNTING POST TOP MOUNTING
Light Controller GC-Clear, formed, plain tempered glass.
SA-Symmetrically formed alum.reflector,semi-specular finish. C180 ___________ C0 ____________
C270 _ _ _ _ _ _ _ _ C90 _ _ _ _ _ _ _ _
J
ADDITIONAL ACCESSORIES Section: U J
23 24
TECHNICAL DATA SHEET
Ballasts for discharge lamps
Technical data:
Normative
167 mm
B 153 mm
C 86.6 mm
D 73.2 mm
E 143 mm
Weight 4700 grs.
Remarks: FT44022HP
The use of this document out of theCompany is not controlled. Technical data subject to change without warning. Product Dept.
05/05/11
High-pressure sodium vapour lamps
T tubular, clear
Product Product
reference number
NAV® as a clear tubular lamp PLANTASTAR® 400 W and 600 W lamps were
Clear tubular NAV® lamps enable light to be directed developed specifically for applications in commercial
with great precision. For new street light installations, horticulture. They enable plants to be intensively
this means that mast spacing can be greater. This cultivated throughout the year.
applies in particular to NAV®-T Super 4Y® lamps with
their extremely high luminous efficacy. Potential
savings are considerable.
The other product characteristics and possible
applications are as described in previous pages.
Optional
For parallel compensation of fluorescent lamps
Für die Parallelkompensation von Leuchtstofflampen
discharge resistor Entladewiderstand < 50V in 60 sec. option without temperature fuse
CN tolerance Toleranz ±10% (optional ±5%) Option ohne Temperatursicherung
** capacitor surface_Kondensatoroberfläche
E02.XXX-XXXXXX
9 30 x 70 E06.C70-300900/220001 72/FB4
10 30 x 70 E06.C70-301000/220001 72/FB4
12 30 x 90 E06.C90-301200/220001 72/FB3
12 30 x 70 E06.C70-301200/220001 72/FB4
13.5 30 x 90 E06.C90-381300/220001 72/FB3
16 30 x 90 E06.C90-301600/220001 72/FB3
18 35 x 90 E06.D90-301810/220001 50/FB3
20 35 x 90 E06.D90-302010/220001 50/FB3
24 40 x 90 E06.E90-302410/220001 36/FB3
25 40 x 90 E06.E90-302510/220001 36/FB3
30 40 x 90 E02
E06.E90-303010/220001 36/FB3
32 35 x 135 E06.D35-403210/220001 50/FB1
32 45 x 90 E06.F90-403210/220001 32/FB1
40 45 x 90 E06.F90-404010/220001 32/FB1
50 45 x 135 E06.F35-405010/220001 32/FB1
55 45 x 135 E06.F35-405510/220001 32/FB1
8
AW
DESIGN AW
DESIGN AW
L ±2.5
Bechermaterial . . . . . . . . . . . . . . . . . . Aluminium
Füllmittel . . . . . . . . . . . . . . . . . . . . . . . ohne (trocken)
Einbaulage . . . . . . . . . . . . . . . . . . . . . . beliebig
Entladewiderstand . . . . . . . . . . . . . . . . intern
Imax (Anschlüsse) . . . . . . . . . . . . . . . . . . 10A
Schutzgrad . . . . . . . . . . . . . . . . . . . . . . IP 20
Feuchtegrad . . . . . . . . . . . . . . . . . . . . . . G
B Anschlüsse
Steckklemme . . . . . . . . . . . . . . . . . . WAGO
Bodenschraube . . . . . . . . . . . . . . . . . . . M8 × 10
D ±5 zul. Drehmoment . . . . . . . . . . . . . . . . . 5Nm
DIMENSIONAL DRAWINGS_MASSZEICHNUNGEN_AW
11
TYPE F1 - PENDENT
TYPE: F1 PENDANT
3DFLILF7&:
7&:[7/':+)3.,7
7&:SFV0$67(57/':+)3HUIRUPHU
3DFLILF7&:LVDIXQFWLRQDOGXVWMHWVKRFNDQGYDQGDOSURRI
OXPLQDLUHDQGFDQDFFRPPRGDWHERWK7/'DQG7/PP
IOXRUHVFHQWODPSV7KHFRYHULVIL[HGWRWKHKRXVLQJE\PHDQVRIDQ
LQQRYDWLYHFRQFHSWXVLQJLQWHJUDWHGIL[LQJSRLQWVWRDYRLGH[WHUQDO
ORFNHUV7KHUHLVDFKRLFHRIGLIIHUHQWVWDQGDUGYHUVLRQVDYDLODEOH7KH
OXPLQDLUHFDQEHPRXQWHGLQGLYLGXDOO\RULQOLQHZLWKHDV\
FOLFN
LQVWDOODWLRQ)OH[LELOLW\LVHQVXUHGZLWKDFKRLFHRIIL[LQJSRLQWVDQG
GLIIHUHQWFDEOHHQWULHV7KH7&:FDQDOVREHVXVSHQGHGIURP
3KLOLSV77;OLJKWOLQHV\VWHPV
3URGXFWGDWD
WITH FUSE
3DFLILF7&:
'LPHQVLRQDOGUDZLQJ
7&:[7/':+)3.,7
7&:[7/':+)3.,7
3KRWRPHWULFGDWD
7&:[7/':+)3
-XQH
GDWDVXEMHFWWRFKDQJH
STANLESS STEEL NUT
STANLESS STEEL MOUNTING 17X3mm - M13X1.0
PLATE 60X15mm
PIPE 14X1500 mm
1000
2014, February 21
data subject to change
An energy-efficient
solution
HF-Performer III for TL-D lamps
Benefits
• The programmed start enables the lamp to be switched on and off
without reducing useful lamp life.
• DC emergency operation in line with IEC/EN 60598-2-22 luminaire
norms
• Smart power ensures constant light, irrespective of mains-voltage
fluctuations
• Suitable for luminaires in protection class I and, after testing, class II
• The universal connector Wago 251 offers the flexibility for
horizontal-manual or push-in robot wiring or vertical ALF-robot
wiring.
Features
• Robust design for 100,000 hours lifetime at Ta=50 ˚C and over
100,000 on/off switching operations on one lamp
• Programmed, flicker-free, pre-heated start (< 0.5 s) which allows the
lamp to be switched on and off without reducing useful lamp life
• Active power factor correction to ensure constant light, irrespective
of mains-voltage fluctuations
• The unit is protected against excessive mains voltage and incorrect
connections.
Application
• Used with movement-detection control systems like Philips
OccuPlus
• Indoor applications, such as office buildings, hospitals, supermarkets,
department stores, industrial premises and schools
• Class I outdoor applications, e.g. industrial premises and parking lots
HF-Performer III for TL-D lamps 2
Related products
Dimensional drawing
HF-P 118 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
B1
HF-P 118 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 218 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 218 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 3/418 TL-D III 220-240V 280.0 265.0 40.0 28.0 4.2
C1
50/60Hz IDC
HF-P 136 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 136 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
A1 50/60Hz IDC
HF-P 236 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 236 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 336 TL-D III 220-240V 280.0 265.0 40.0 28.0 4.2
50/60Hz IDC
HF-P 158 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 158 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
HF-P 258 TL-D III 220-240V 280.0 265.0 30.0 28.0 4.2
50/60Hz IDC
2014, February 21
data subject to change
HF-Performer III for TL-D lamps 3
General Characteristics
Order code Full product name Applica- Rated Rated Rated Line Line Housing Energy
tion Lamptype Number of Ballast- Voltage Frequency Efficiency
code Lamps Lamp Index
Power
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz III TL-D 1 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz III TL-D 1 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz III TL-D 2 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz III TL-D 2 piece 18 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz III TL-D 3/4 piece 18 220-240 V 50/60 Hz L 280x40x28 A2 BAT
IDC
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz III TL-D 1 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz III TL-D 1 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz III TL-D 2 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz III TL-D 2 piece 36 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz III TL-D 3 piece 36 220-240 V 50/60 Hz L 280x40x28 A2 BAT
IDC
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz III TL-D 1 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz III TL-D 1 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz III TL-D 2 piece 58 220-240 V 50/60 Hz L 280x30x28 A2 BAT
IDC
Performance diagrams
Wiring data
1
2
1 3
HF 2
BALLAST 1 4
3
4 5
L 2 HF 6
N HF-P 3 BALLAST 7
13 L 8
BALLAST
12 4 N 9
11 5 10
6
1
2
HF-P 2 TL-D/TL5 (keep wires 1;2 & 5;6 short) 3
4
5
HF 6
BALLAST 7
L 8
N 9
10
2014, February 21
data subject to change
HF-Performer III for TL-D lamps 4
Order code Full product name Lamp Power on TL-D Order code Full product name Bal Lm Fac Emergency
operation
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz IDC 15.8
913713031266 HF-P 118 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz IDC 15.8
913713031267 HF-P 118 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz IDC 32.2
913713031366 HF-P 218 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz IDC 32.2
913713031367 HF-P 218 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz IDC 48.7/66.2
913713031466 HF-P 3/418 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz IDC 32.5
913713031566 HF-P 136 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz IDC 32.5
913713031567 HF-P 136 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz IDC 62.5
913713031666 HF-P 236 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz IDC 62.5
913713031667 HF-P 236 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz IDC 95
913713031766 HF-P 336 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz IDC 51.9
913713031866 HF-P 158 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz IDC 51.9
913713031867 HF-P 158 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031963 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031966 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz IDC 98
913713031967 HF-P 258 TL-D III 220-240V 50/60Hz IDC 0.7 -
Specifications are subject to change without notice. Trademarks are the property of
Koninklijke Philips N.V. (Royal Philips) or their respective owners.
Efficient fluorescent
lighting with improved
color rendering
MASTER TL-D Super 80
Benefits
• Good color rendering
• Relatively high efficacy, both initially and during lamp lifetime, with
high lumen maintenance
• Create atmospheres from warm white to cool daylight
Features
• Highly efficient 3-band fluorescent coating
• High initial light output compared with standard colors
• Low mercury dose
• Can be used with conventional or electronic gear
• Higher efficacy is achieved with electronic gear
Application
• Suitable for use in a wide range of luminaires for TL-D fluorescent
lamps for 'human' applications such as schools, offices, shops, factory
halls etc.
MASTER TL-D Super 80 2
Related products
G13, T8
Dimensional drawing
2014, January 6
data subject to change
MASTER TL-D Super 80 3
Dimensional drawing
Order Full product name Cap- Bulb Life to Life to 10% Life to 10% Life to Life to 50% Life to 50% LSF EM LSF EM
code Base 10% fail fail 50% fail fail 2000h 4000h
failures Preheat Nonpreh failures Preheat Nonpreh Rated,3h Rated,3h
EM EL,3h EL,3h EM EL,3h EL,3h cycle cycle
927920082712 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/827 1SL
927920082723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/827 1SL
927920083023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/830 1SL
927920083069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/830 UNP
927920083523 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/835 1SL
927920084023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 1SL
927920084069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 UNP
927920084093 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/840 1SL
927920086544 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
18W/865 1SL
927920582723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 97 %
30W/827 1SL
927920583023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/830 1SL
927920584023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/840 1SL
927920586514 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
30W/865 1SL
927921082712 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/827 1SL
927921082723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/827 1SL
927921083023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/830 1SL
2014, January 6
data subject to change
MASTER TL-D Super 80 4
Order Full product name Cap- Bulb Life to Life to 10% Life to 10% Life to Life to 50% Life to 50% LSF EM LSF EM
code Base 10% fail fail 50% fail fail 2000h 4000h
failures Preheat Nonpreh failures Preheat Nonpreh Rated,3h Rated,3h
EM EL,3h EL,3h EM EL,3h EL,3h cycle cycle
927921083069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/830 UNP
927921083523 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/835 1SL
927921084023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/840 1SL
927921084069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/840 UNP
927921084093 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/840 1SL
927921086544 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/865 1SL
927922082712 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/827 1SL
927922082723 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/827 1SL
927922083023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/830 1SL
927922083069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/830 UNP
927922083081 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/830 1SL
927922083523 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/835 1SL
927922084023 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/840 1SL
927922084069 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/840 UNP
927922084081 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/840 1SL
927922084093 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/840 1SL
927922086544 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
58W/865 1SL
927922282714 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
15W/827 1SL
927922283014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
15W/830 1SL
927922284014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
15W/840 1SL
927922286514 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
15W/865 1SL
927922583014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
23W/830 1SL
927922584014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
23W/840 1SL
927922586514 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 10000 hr 99 % 99 %
23W/865 1SL
927923083014 MASTER TL-D Super 80 1m G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/830 1SL
927923084014 MASTER TL-D Super 80 1m G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/840 1SL
927923086514 MASTER TL-D Super 80 1m G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 99 %
36W/865 1SL
927923583014 MASTER TL-D Super 80 G13 T8 12000 hr 17000 hr 10000 hr 15000 hr 20000 hr 12000 hr 99 % 97 %
38W/830 1SL
2014, January 6
data subject to change
UP201/5-150VPK.AA Product no.
REFERENCE
DESIGN
1: Product description : Roadway Luminaire
: Classification & application : Outdoor
: Color : Gray
8: Degree of protection : IP 65 (dust tight and water jet proof)
: Material of housing : Aluminum
: Housing fabrication : Extruded aluminum anodized, end cover are die-cast
aluminum secured to housing by screws and sealed
4: Reflector : Assymmetrical die-formed aluminum
: Mounting options : Surface or suspended mounted by brackets or pipes
: Accessory : Construct with fuse
: Cable entry : 20.5mm dia. hole each end of housing with glands
: Cable connection : Terminal block, 5-pole, screw type with grounding
ELECTRICAL
Cable Entry Cable entry through PG13.5 cable gland at the side of the luminaire.
130 B
Lamps 18,36 W & 58W - T8 Fluorescent lamp, switch start or electronic start.
17,32 W & 40W - T8 Flourescent lamp, electronic start.
PHOTOMETRY
A
2-150W max. Metal Halide Elliptical Lamp.
I [cd/10001m]
3- 400W max. Metal Halide Tubular Lamp.
4- 150W max. High Pressure Sodium Elliptical Lamp.
5- 400W max. High Pressure Sodium Tubular Lamp.
105° 120° 150°
50
50°
50
0°
150° 120° 105° MOUNTING SYSTEM
6- 180W max. Low Pressure Sodium Tubular Lamp. 90° 90°
Other lamp sources available on request. 80°
80°
10
00°
0 0
75° 75°
Voltage 120, 220, 240 or 227 VAC, 50/60 Hz.
Other voltage and Frequency upon request. 20
200
00°
0 0
60° 60°
Control Gear 30
300
00°
0 0
High Power Factor
40
400
00°
0 0
Ligh Controller GL-Clear, plain tempered flat glass in frame. 45° 45°
SA- Symmetrically roll formed alum. reflector, hammered pattern specular finish. 30° 15° 0° 15° 30°
GF- Clear, frosted tempered flat glass in frame.
AA- Asymmetrically formed alum. reflector, hammered pattern specular finish.
SA3-Symmetrically roll formed alum. reflector, plain pattern specular finish. C180 ___________ C0 ___________ CEILING MOUNTED SEMI RECESSED MOUNTED WALL MOUNTED PENDANT MOUNTED
C270 _ _ _ _ _ _ _ _ C90 _ _ _ _ _ _ _ _
J
ADDITIONAL ACCESSORIES Section: U J
49 50
TECHNICAL DATA SHEET
Ballasts for discharge lamps
Technical data:
ELECTRICAL DATA TEMPERATURE
Normative
A 135.3 mm
B 121.3 mm
C 65 mm
D 52.3 mm
E 116.3 mm
Weight 2050 grs.
Remarks: FT415720000
Product Dept.
The use of this document out of theCompany is not controlled. Technical data subject to change without warning.
06/03/12
High-pressure sodium vapour lamps
T tubular, clear
Product Product
reference number
NAV® as a clear tubular lamp PLANTASTAR® 400 W and 600 W lamps were
Clear tubular NAV® lamps enable light to be directed developed specifically for applications in commercial
with great precision. For new street light installations, horticulture. They enable plants to be intensively
this means that mast spacing can be greater. This cultivated throughout the year.
applies in particular to NAV®-T Super 4Y® lamps with
their extremely high luminous efficacy. Potential
savings are considerable.
The other product characteristics and possible
applications are as described in previous pages.
Optional
For parallel compensation of fluorescent lamps
Für die Parallelkompensation von Leuchtstofflampen
discharge resistor Entladewiderstand < 50V in 60 sec. option without temperature fuse
CN tolerance Toleranz ±10% (optional ±5%) Option ohne Temperatursicherung
** capacitor surface_Kondensatoroberfläche
E02.XXX-XXXXXX
9 30 x 70 E06.C70-300900/220001 72/FB4
10 30 x 70 E06.C70-301000/220001 72/FB4
12 30 x 90 E06.C90-301200/220001 72/FB3
12 30 x 70 E06.C70-301200/220001 72/FB4
13.5 30 x 90 E06.C90-381300/220001 72/FB3
16 30 x 90 E02
E06.C90-301600/220001 72/FB3
18 35 x 90 E06.D90-301810/220001 50/FB3
20 35 x 90 E06.D90-302010/220001 50/FB3
24 40 x 90 E06.E90-302410/220001 36/FB3
25 40 x 90 E06.E90-302510/220001 36/FB3
30 40 x 90 E06.E90-303010/220001 36/FB3
32 35 x 135 E06.D35-403210/220001 50/FB1
32 45 x 90 E06.F90-403210/220001 32/FB1
40 45 x 90 E06.F90-404010/220001 32/FB1
50 45 x 135 E06.F35-405010/220001 32/FB1
55 45 x 135 E06.F35-405510/220001 32/FB1
8
AW
DESIGN AW
DESIGN AW
L ±2.5
Bechermaterial . . . . . . . . . . . . . . . . . . Aluminium
Füllmittel . . . . . . . . . . . . . . . . . . . . . . . ohne (trocken)
Einbaulage . . . . . . . . . . . . . . . . . . . . . . beliebig
Entladewiderstand . . . . . . . . . . . . . . . . intern
Imax (Anschlüsse) . . . . . . . . . . . . . . . . . . 10A
Schutzgrad . . . . . . . . . . . . . . . . . . . . . . IP 20
Feuchtegrad . . . . . . . . . . . . . . . . . . . . . . G
B Anschlüsse
Steckklemme . . . . . . . . . . . . . . . . . . WAGO
Bodenschraube . . . . . . . . . . . . . . . . . . . M8 × 10
D ±5 zul. Drehmoment . . . . . . . . . . . . . . . . . 5Nm
DIMENSIONAL DRAWINGS_MASSZEICHNUNGEN_AW
11
A201/5-150VPK.SA5.FU Product no.
REFERENCE
DESIGN
1: Product description : Amenity luminaire
: Application : Outdoors
: Color : Gray
8: Degree of protection : IP 55 (dust proof & water jet proof)
: Material of housing : Galvanized sheet steel
: Housing fabrication : Die-formed, spot welded, pre-treated stove enameled,
4: Optical : Parabolic shape hammered finish aluminum.
Clear tempered flat glass in hinged frame lock by screws
: Mounting options : Pole arm bracket or wall arm bracket mounted ordered
separately. Direct ceiling mounted.
: Cable entry : Wiring access through control gear compartment
5 : Accessory : Construct with fuse
: Cable connection : Terminal block, 3-pole, screw type with grounding
: Dimensions of fixture : Reference catalogue A201
ELECTRICAL
2: Light source : 150 watts high pressure sodium elliptical lamp
: Lamp type : High intensity discharge
: Lamp holder : E 40
3: Voltage rating & circuitry : 230V/60Hz, reactor type
: Voltage fluctuation allowable : ± 10 %
: Ballast construction : Electromagnetic, IEC 922, 923
: Input power : 167 watts
: Power factor : HPF,>0.90
: Line current : 0.84 A
: Internal wiring : 1.0 mm² solid copper wire, 150°C
A201
* GL-Clear, plain, tempered flat glass , SA-Symmetrically formed alum. reflector,specular finish in frame , AA-Asymmetrically formed alum. reflector,specular finish.
A201 / 5 250 B P . GL . SA
Product Number
Lamp Type Symmetrically formed alum. reflector, specular finish in frame
SPECIFICATION FEATURES
DIMENSIONAL DRAWING
Design Body and Glass frame are made of formed zinc coated steel sheet,
A
pre-treated and powder coated in grey color. (Other colors available
on request)
Gear tray is made of formed galvanized steel sheet.
Reflector is made of roll formed aluminum sheet, anodized with
specular finish.
Glass is tempered clear and flat, resistant to high temperatures.
Gasket is provided between glass frame and housing to seal out B
dust and water.
C
Mounting Surface mounted by means of L-shaped mounting bracket.
Recessed mounted inside the cavity.
Swivel mounted on 600 x 600 cut-out on concrete slab.
Cable Entry Cable entry through 21.0 dia. hole with compression gland at the
PHOTOMETRY
back of the luminaire. I [cd/10001m]
Lamps 1 - 400 W max. Mercury Vapor “MV” elliptical lamp. 105° 120° 150°150° 120° 105°
MOUNTING SYSTEM
2 - 400 W max. Metal Halide “MH” elliptical lamp.
4 - 400 W max. High pressure Sodium “HPS” elliptical lamp. 90° 90°
3 - 400 W max. Metal halide “MH” tubular lamp. 80° 80° CONCRETE CEILING CONCRETE CAVITY
5 - 400 W max. High pressure Sodium “HPS” tubular lamp. 75° 150
°0 75°
J
ADDITIONAL ACCESSORIES Section: U J
33 34
TECHNICAL DATA SHEET
Ballasts for discharge lamps
Technical data:
ELECTRICAL DATA TEMPERATURE
Normative
A 135.3 mm
B 121.3 mm
C 65 mm
D 52.3 mm
E 116.3 mm
Weight 2050 grs.
Remarks: FT415720000
Product Dept.
The use of this document out of theCompany is not controlled. Technical data subject to change without warning.
06/03/12
High-pressure sodium vapour lamps
T tubular, clear
Product Product
reference number
NAV® as a clear tubular lamp PLANTASTAR® 400 W and 600 W lamps were
Clear tubular NAV® lamps enable light to be directed developed specifically for applications in commercial
with great precision. For new street light installations, horticulture. They enable plants to be intensively
this means that mast spacing can be greater. This cultivated throughout the year.
applies in particular to NAV®-T Super 4Y® lamps with
their extremely high luminous efficacy. Potential
savings are considerable.
The other product characteristics and possible
applications are as described in previous pages.
Optional
For parallel compensation of fluorescent lamps
Für die Parallelkompensation von Leuchtstofflampen
discharge resistor Entladewiderstand < 50V in 60 sec. option without temperature fuse
CN tolerance Toleranz ±10% (optional ±5%) Option ohne Temperatursicherung
** capacitor surface_Kondensatoroberfläche
E02.XXX-XXXXXX
9 30 x 70 E06.C70-300900/220001 72/FB4
10 30 x 70 E06.C70-301000/220001 72/FB4
12 30 x 90 E06.C90-301200/220001 72/FB3
12 30 x 70 E06.C70-301200/220001 72/FB4
13.5 30 x 90 E06.C90-381300/220001 72/FB3
16 30 x 90 E02
E06.C90-301600/220001 72/FB3
18 35 x 90 E06.D90-301810/220001 50/FB3
20 35 x 90 E06.D90-302010/220001 50/FB3
24 40 x 90 E06.E90-302410/220001 36/FB3
25 40 x 90 E06.E90-302510/220001 36/FB3
30 40 x 90 E06.E90-303010/220001 36/FB3
32 35 x 135 E06.D35-403210/220001 50/FB1
32 45 x 90 E06.F90-403210/220001 32/FB1
40 45 x 90 E06.F90-404010/220001 32/FB1
50 45 x 135 E06.F35-405010/220001 32/FB1
55 45 x 135 E06.F35-405510/220001 32/FB1
8
AW
DESIGN AW
DESIGN AW
L ±2.5
Bechermaterial . . . . . . . . . . . . . . . . . . Aluminium
Füllmittel . . . . . . . . . . . . . . . . . . . . . . . ohne (trocken)
Einbaulage . . . . . . . . . . . . . . . . . . . . . . beliebig
Entladewiderstand . . . . . . . . . . . . . . . . intern
Imax (Anschlüsse) . . . . . . . . . . . . . . . . . . 10A
Schutzgrad . . . . . . . . . . . . . . . . . . . . . . IP 20
Feuchtegrad . . . . . . . . . . . . . . . . . . . . . . G
B Anschlüsse
Steckklemme . . . . . . . . . . . . . . . . . . WAGO
Bodenschraube . . . . . . . . . . . . . . . . . . . M8 × 10
D ±5 zul. Drehmoment . . . . . . . . . . . . . . . . . 5Nm
DIMENSIONAL DRAWINGS_MASSZEICHNUNGEN_AW
11
1 - LIGHTING CALCULATION
TABLE OF CONTENT
LIGHTING CLACULATION
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 278 cd/klm
Luminaire Wattage: 400.0 W at 80°: 128 cd/klm
Arrangement: on Median at 90°: 84 cd/klm
Pole Distance: 30.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 14.000 m Arrangement complies with glare index class D.5.
Height: 14.030 m
Overhang (2): -0.500 m
Boom Angle (3): 20.0 °
Boom Length (4): 2.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
28.00 0.83
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
17.91 0.85
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Luminaire Arrangements
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
3 RAMP-2
Length: 80.000 m, Width: 7.300 m
Grid: 27 x 5 Points
Accompanying Street Elements: RAMP-2.
Selected Lighting Class: CE2
Eav [lx] U0
43.68 0.68
4 RAMP-1
Length: 80.000 m, Width: 7.300 m
Grid: 27 x 5 Points
Accompanying Street Elements: RAMP-1.
Selected Lighting Class: CE2
Eav [lx] U0
45.84 0.70
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (2) SLC Propsal / Valuation Field Roadway 1 / Results overview
Grid: 27 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (2) SLC Propsal / Valuation Field Roadway 1 / Isolines (E)
Grid: 27 x 6 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (2) SLC Propsal / Valuation Field Roadway 1 / Value Chart (E)
Grid: 27 x 6 Points
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (2) SLC Propsal / Valuation Field Roadway 2 / Results overview
Grid: 27 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (2) SLC Propsal / Valuation Field Roadway 2 / Isolines (E)
Grid: 27 x 6 Points
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (2) SLC Propsal / Valuation Field Roadway 2 / Value Chart (E)
Grid: 27 x 6 Points
Page 13
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-150B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 13354 lm Maximum luminous intensities
Luminous flux (Lamps): 16000 lm at 70°: 166 cd/klm
Luminaire Wattage: 150.0 W at 80°: 90 cd/klm
Arrangement: Single row, bottom at 90°: 19 cd/klm
Pole Distance: 25.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 8.000 m Arrangement complies with luminous intensity class G3.
Height: 7.939 m Arrangement complies with glare index class D.6.
Overhang (2): 0.500 m
Boom Angle (3): 10.0 °
Boom Length (4): 1.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
22.17 0.50
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
18.14 0.81
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 10 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 10 x 6 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (2) RAMP-1A / Valuation Field Roadway 2 / Value Chart (E)
Grid: 10 x 6 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Luminaire Arrangements
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
3 RAMP-2
Length: 80.000 m, Width: 7.300 m
Grid: 27 x 5 Points
Accompanying Street Elements: RAMP-2.
Selected Lighting Class: CE2
Eav [lx] U0
48.67 0.73
4 RAMP-1
Length: 80.000 m, Width: 7.300 m
Grid: 27 x 5 Points
Accompanying Street Elements: RAMP-1.
Selected Lighting Class: CE2
Eav [lx] U0
48.69 0.74
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 6 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 6 Points
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 5 Points
Accompanying Street Elements: RAMP-2.
Selected Lighting Class: CE2
Eav [lx] U0
48.67 0.73
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 5 Points
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 5 Points
Page 13
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-150B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 13354 lm Maximum luminous intensities
Luminous flux (Lamps): 16000 lm at 70°: 166 cd/klm
Luminaire Wattage: 150.0 W at 80°: 90 cd/klm
Arrangement: Single row, bottom at 90°: 19 cd/klm
Pole Distance: 25.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 8.000 m Arrangement complies with luminous intensity class G3.
Height: 7.939 m Arrangement complies with glare index class D.6.
Overhang (2): 0.500 m
Boom Angle (3): 10.0 °
Boom Length (4): 1.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
22.17 0.50
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
18.14 0.81
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 10 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 10 x 6 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (3) RAMP-1A / Valuation Field Roadway 2 / Value Chart (E)
Grid: 10 x 6 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-150B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 13354 lm Maximum luminous intensities
Luminous flux (Lamps): 16000 lm at 70°: 205 cd/klm
Luminaire Wattage: 150.0 W at 80°: 102 cd/klm
Arrangement: Single row, bottom at 90°: 53 cd/klm
Pole Distance: 25.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 8.000 m Arrangement complies with glare index class D.6.
Height: 7.985 m
Overhang (2): 0.500 m
Boom Angle (3): 15.0 °
Boom Length (4): 1.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (3) STREET NEAR FIRE TANK / Luminaire parts list
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
20.07 0.49
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
24.68 0.77
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (3) STREET NEAR FIRE TANK / False Color Rendering
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (3) STREET NEAR FIRE TANK / Valuation Field Roadway 2 / Results overview
Grid: 10 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (3) STREET NEAR FIRE TANK / Valuation Field Roadway 2 / Isolines (E)
Grid: 10 x 6 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (3) STREET NEAR FIRE TANK / Valuation Field Roadway 2 / Value Chart (E)
Grid: 10 x 6 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Luminaire Arrangements
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Luminaire Arrangements
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
1 RAMP-1A
Length: 80.000 m, Width: 7.300 m
Grid: 27 x 5 Points
Accompanying Street Elements: RAMP-1A.
Selected Lighting Class: CE2
Eav [lx] U0
55.01 0.64
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 5 Points
Accompanying Street Elements: RAMP-1A.
Selected Lighting Class: CE2
Eav [lx] U0
55.01 0.64
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 5 Points
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 5 Points
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 9 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 9 Points
Page 13
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 27 x 9 Points
Page 14
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 278 cd/klm
Luminaire Wattage: 400.0 W at 80°: 128 cd/klm
Arrangement: on Median at 90°: 84 cd/klm
Pole Distance: 35.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 12.000 m Arrangement complies with glare index class D.5.
Height: 12.030 m
Overhang (2): -0.499 m
Boom Angle (3): 20.0 °
Boom Length (4): 2.001 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
22.14 0.84
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
22.17 0.86
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A) & (5B) / Valuation Field Roadway 1 / Results overview
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME2
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A) & (5B) / Valuation Field Roadway 1 / Isolines (E)
Grid: 9 x 3 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A) & (5B) / Valuation Field Roadway 1 / Value Chart (E)
Grid: 9 x 3 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A), (5-B), (6-A), (6-B) AND (6-C) / Planning data
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 278 cd/klm
Luminaire Wattage: 400.0 W at 80°: 128 cd/klm
Arrangement: on Median at 90°: 84 cd/klm
Pole Distance: 35.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 12.000 m Arrangement complies with glare index class D.5.
Height: 12.030 m
Overhang (2): -0.500 m
Boom Angle (3): 20.0 °
Boom Length (4): 2.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A), (5-B), (6-A), (6-B) AND (6-C) / Luminaire parts list
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A), (5-B), (6-A), (6-B) AND (6-C) / Photometric Results
Eav [lx] U0
22.14 0.84
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A), (5-B), (6-A), (6-B) AND (6-C) / Photometric Results
Eav [lx] U0
22.16 0.86
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A), (5-B), (6-A), (6-B) AND (6-C) / False Color Rendering
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A), (5-B), (6-A), (6-B) AND (6-C) / Valuation Field Roadway 1 / Results
overview
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A), (5-B), (6-A), (6-B) AND (6-C) / Valuation Field Roadway 1 / Isolines (E)
Grid: 9 x 3 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (5-A), (5-B), (6-A), (6-B) AND (6-C) / Valuation Field Roadway 1 / Value Chart (E)
Grid: 9 x 3 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / Planning data
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-150B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 13354 lm Maximum luminous intensities
Luminous flux (Lamps): 16000 lm at 70°: 166 cd/klm
Luminaire Wattage: 150.0 W at 80°: 90 cd/klm
Arrangement: Single row, bottom at 90°: 19 cd/klm
Pole Distance: 25.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 8.000 m Arrangement complies with luminous intensity class G3.
Height: 7.939 m Arrangement complies with glare index class D.6.
Overhang (2): 0.500 m
Boom Angle (3): 10.0 °
Boom Length (4): 1.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / Luminaire parts
list
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / Photometric
Results
Eav [lx] U0
22.17 0.50
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / Photometric
Results
Eav [lx] U0
18.14 0.81
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / 3D Rendering
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / False Color
Rendering
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / Valuation Field
Roadway 2 / Results overview
Grid: 10 x 6 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / Valuation Field
Roadway 2 / Isolines (E)
Grid: 10 x 6 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
TYPICAL RAMPS (RAMP3, RAMP4, RAMP3A, RAMP4A, RAMP5 AND RAMP6) / Valuation Field
Roadway 2 / Value Chart (E)
Grid: 10 x 6 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 234 cd/klm
Luminaire Wattage: 400.0 W at 80°: 120 cd/klm
Arrangement: on Median at 90°: 68 cd/klm
Pole Distance: 30.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 14.000 m Arrangement complies with glare index class D.5.
Height: 13.985 m
Overhang (2): 1.500 m
Boom Angle (3): 15.0 °
Boom Length (4): 4.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
28.91 0.84
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
43.85 0.88
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (M-BR-1) &(H-2) / Valuation Field Roadway 1 / Value Chart (E)
Grid: 9 x 3 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 278 cd/klm
Luminaire Wattage: 400.0 W at 80°: 128 cd/klm
Arrangement: on Median at 90°: 84 cd/klm
Pole Distance: 30.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 14.000 m Arrangement complies with glare index class D.5.
Height: 14.030 m
Overhang (2): 0.500 m
Boom Angle (3): 20.0 °
Boom Length (4): 3.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
29.28 0.87
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
43.40 0.90
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (M-BR-1), (H-1), (H-2) / Valuation Field Roadway 2 / Results overview
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (M-BR-1), (H-1), (H-2) / Valuation Field Roadway 2 / Isolines (E)
Grid: 9 x 3 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (M-BR-1), (H-1), (H-2) / Valuation Field Roadway 2 / Value Chart (E)
Grid: 9 x 3 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (M-BR-1), (H-1), (H-2) / Valuation Field Roadway 1 / Results overview
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME4a
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (M-BR-1), (H-1), (H-2) / Valuation Field Roadway 1 / Isolines (E)
Grid: 9 x 3 Points
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
CROSS SECTION (M-BR-1), (H-1), (H-2) / Valuation Field Roadway 1 / Value Chart (E)
Grid: 9 x 3 Points
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 278 cd/klm
Luminaire Wattage: 400.0 W at 80°: 128 cd/klm
Arrangement: on Median at 90°: 84 cd/klm
Pole Distance: 30.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 14.000 m Arrangement complies with glare index class D.5.
Height: 14.030 m
Overhang (2): -0.500 m
Boom Angle (3): 20.0 °
Boom Length (4): 2.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
29.46 0.87
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
29.43 0.88
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 234 cd/klm
Luminaire Wattage: 400.0 W at 80°: 120 cd/klm
Arrangement: Double row, opposing at 90°: 68 cd/klm
Pole Distance: 40.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for
Mounting Height (1): 12.000 m use.
Height: 11.985 m Arrangement complies with glare index class D.5.
Overhang (2): -0.205 m
Boom Angle (3): 15.0 °
Boom Length (4): 1.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-150B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 13354 lm Maximum luminous intensities
Luminous flux (Lamps): 16000 lm at 70°: 205 cd/klm
Luminaire Wattage: 150.0 W at 80°: 102 cd/klm
Arrangement: Single row, bottom at 90°: 53 cd/klm
Pole Distance: 25.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 8.000 m Arrangement complies with glare index class D.6.
Height: 7.985 m
Overhang (2): -12.000 m
Boom Angle (3): 15.0 °
Boom Length (4): 1.000 m
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
1 CARRIAGEWAY
Length: 40.000 m, Width: 7.300 m
Grid: 14 x 5 Points
Accompanying Street Elements: CARRIAGEWAY.
Selected Lighting Class: CE2
Eav [lx] U0
42.61 0.58
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Accompanying Street Elements: CARRIAGEWAY.
Selected Lighting Class: CE2
Eav [lx] U0
42.61 0.58
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Page 13
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 14
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 6 Points
Page 15
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 6 Points
Page 16
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 234 cd/klm
Luminaire Wattage: 400.0 W at 80°: 120 cd/klm
Arrangement: Double row, opposing at 90°: 68 cd/klm
Pole Distance: 40.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for
Mounting Height (1): 12.000 m use.
Height: 11.985 m Arrangement complies with glare index class D.5.
Overhang (2): -0.205 m
Boom Angle (3): 15.0 °
Boom Length (4): 1.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 234 cd/klm
Luminaire Wattage: 400.0 W at 80°: 120 cd/klm
Arrangement: Single row, bottom at 90°: 68 cd/klm
Pole Distance: 40.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 22.200 m Arrangement complies with glare index class D.5.
Height: 22.185 m
Overhang (2): -12.000 m
Boom Angle (3): 15.0 °
Boom Length (4): 1.000 m
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
1 CARRIAGEWAY
Length: 40.000 m, Width: 7.300 m
Grid: 14 x 5 Points
Accompanying Street Elements: CARRIAGEWAY.
Selected Lighting Class: CE2
Eav [lx] U0
40.65 0.65
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
36.42 0.56
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Accompanying Street Elements: CARRIAGEWAY.
Selected Lighting Class: CE2
Eav [lx] U0
40.65 0.65
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Page 13
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 6 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 14
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 6 Points
Page 15
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 6 Points
Page 16
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 234 cd/klm
Luminaire Wattage: 400.0 W at 80°: 120 cd/klm
Arrangement: Single row, top at 90°: 68 cd/klm
Pole Distance: 40.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 12.000 m Arrangement complies with glare index class D.5.
Height: 11.985 m
Overhang (2): 0.000 m
Boom Angle (3): 15.0 °
Boom Length (4): 1.000 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 234 cd/klm
Luminaire Wattage: 400.0 W at 80°: 120 cd/klm
Arrangement: Single row, bottom at 90°: 68 cd/klm
Pole Distance: 25.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 18.200 m Arrangement complies with glare index class D.5.
Height: 18.185 m
Overhang (2): -14.500 m
Boom Angle (3): 15.0 °
Boom Length (4): 1.000 m
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
1 CARRIAGEWAY
Length: 40.000 m, Width: 7.300 m
Grid: 14 x 5 Points
Accompanying Street Elements: CARRIAGEWAY.
Selected Lighting Class: CE2
Eav [lx] U0
86.06 0.59
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
36.02 0.75
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Accompanying Street Elements: CARRIAGEWAY.
Selected Lighting Class: CE2
Eav [lx] U0
86.06 0.59
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 5 Points
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Accompanying Street Elements: Roadway 2.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 14 x 9 Points
Page 13
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Street Profile
Luminaire Arrangements
Luminaire: SAUDILIGHTING 7435PS/5-400B (LHP 2A) G.E. Lamp Post-Side Mounted Semi Cut-Off Road
Luminaire
Luminous flux (Luminaire): 41997 lm Maximum luminous intensities
Luminous flux (Lamps): 51000 lm at 70°: 278 cd/klm
Luminaire Wattage: 400.0 W at 80°: 128 cd/klm
Arrangement: on Median at 90°: 84 cd/klm
Pole Distance: 40.000 m Any direction forming the specified angle from the downward vertical, with the luminaire installed for use.
Mounting Height (1): 12.000 m Arrangement complies with glare index class D.5.
Height: 12.030 m
Overhang (2): -1.001 m
Boom Angle (3): 20.0 °
Boom Length (4): 1.500 m
Page 1
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
21.63 0.79
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Eav [lx] U0
21.65 0.81
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Accompanying Street Elements: Roadway 1.
tarmac: R3, q0: 0.070
Selected Lighting Class: ME1
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 26.03.2014
Grid: 9 x 3 Points
Page 9
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Maintenance factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
SAUDILIGHTING UP201S/3-400.SA TUNNEL
2 320 22940 35000 400.0
LIGHT (1.000)
Total: 8376754 Total: 12236512 138620.0
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 1
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE / Luminaire parts list
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 2
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 3
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 4
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 5
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 6
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 7
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 8
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 9
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 10
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 11
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 12
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 13
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 14
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 15
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 16
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 17
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 18
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 19
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 20
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 21
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 22
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 23
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Maintenance factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
SAUDILIGHTING UP201S/3-400.SA TUNNEL
2 244 22940 35000 400.0
LIGHT (1.000)
Total: 6633288 Total: 9576512 108220.0
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 1
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 TRANSITION ZONE 1 / Luminaire parts list
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 2
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 3
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 4
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 5
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 6
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 7
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 8
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 9
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 10
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 11
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 12
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 13
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 14
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 15
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 16
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 17
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 18
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 19
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 20
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 21
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Maintenance factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
SAUDILIGHTING UP201S/3-250B.SA Surface
2 200 13109 20000 250.0
Mounted Heavy-Duty Tunnel Luminaire (1.000)
Total: 3657597 Total: 5036512 60620.0
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 1
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 TRANSITION ZONE 2 / Luminaire parts list
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 2
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 3
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 4
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 5
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 6
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 7
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 8
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 9
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 10
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 11
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 12
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 13
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 14
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 15
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 16
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 17
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 18
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 19
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 20
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Maintenance factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
SAUDILIGHTING UP201S/3-150B.SA Surface
2 132 8521 13000 150.0
Mounted Heavy-Duty Tunnel Luminaire (1.000)
Total: 2160576 Total: 2752512 30420.0
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 1
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 TRANSITION ZONE 3 / Luminaire parts list
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 2
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 3
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 4
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 5
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 6
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 7
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 8
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 9
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 10
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 11
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 12
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 13
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 14
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 15
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 16
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 17
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Order, Page
please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 18
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Maintenance factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
Total: 1035843 Total: 1036512 10620.0
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 1
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 INTERIOR ZONE / Luminaire parts list
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 2
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 INTERIOR ZONE / Luminaires (layout plan)
Scale 1 : 679
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 3
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 4
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 5
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 6
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 7
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 8
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 9
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 INTERIOR ZONE / False Colour Rendering
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 10
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 11
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 12
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 13
MAKKAH FIRST RING ROAD (J14-054)
09.03.2014
Grid: 15 x 3 Points
Rotation: 90.0°
[DISCLAIMER: Luminaire Part Numbers used in this report are for design selection purposes only. For Request for Quotation or Purchase Page
Order, please refer to SLC Sales Engineer for the Final Commercial Part Numbers.] 14
2- GENERAL COMPARISON FOR
LIGHTING CALCULATION.
Ahmad Alazizi
From: Anas Mahmud
Sent: Monday, April 07, 2014 12:14 PM
To: ahmed mohamed asaad
Cc: belal mahmoud; Amer Jundi; Gamal Mostafa Mohamed; khaled elsheikh;
meliwasbg@gmail.com; 'Mohammad Javed'; fdibis@saudilighting.com'; Ahmad Alazizi
Subject: RE: MFRR/BID2002/Material Submittal
Attachments: MAKKAH FIRST RING ROAD (J14-054).pdf
Dear Ahmed
Please find the attached lighting calculation comparison for QUSHASHIAH Tunnel THRESHOLD ZONE using 6
types of tunnel lighting as follow
1. SLC UP201
2. PHILIPS SGX320
3. PHILIPS SRX509
4. SCHREDER AF4 / 200681
5. SCHREDER AF4 / 240041
6. SCHREDER AF4 / 972644
The result as follow
Lighting Fixture Luminance (Cd/m2)
SLC UP201 168
PHILIPS SGX320 149
PHILIPS SRX509 151
SCHREDER AF4 / 200681 173
SCHREDER AF4 / 240041 182
SCHREDER AF4 / 972644 169
As a result the maximum deferent between the achieved levels not exceeding 20%.
Eng. Anas Mahmoud,MIES,AILP
Saudi Lighting Company
Product Specifier and Lighting Designer Eng.
Western Area
: 00966 2 6691872 Ext. 111
: 00966 2 6690972
: 00966 5 01075850
E‐mail : mailto:anas@saudilighting.com
1
From: ahmed mohamed asaad [mailto:ahmed.asaad@sbg-mp.com]
Sent: Saturday, April 05, 2014 9:17 PM
To: fdibis@saudilighting.com'; Ahmad Alazizi; Anas Mahmud
Cc: belal mahmoud; Amer Jundi; Gamal Mostafa Mohamed; khaled elsheikh; meliwasbg@gmail.com; 'Mohammad
Javed'
Subject: MFRR/BID2002/Material Submittal
Dear Eng.Ahmed
Reference to our last meeting on last week.
Kindly edit the material submittal of lighting fixture with our comments as we agreed, also please prepare
the received technical submittal for standard lighting poles and high mast to be submitted also as a
material submittal for standard lighting poles and high mast.
Moreover; please refer to the non‐standard lighting poles in the material submittal “ to be submitted
separately after receiving the final CCTV system design from CCTV suppliers”.
Waiting your feedback in order to determine a appointment for a meeting with Dar Al Handasa to get them
approval for the material submittal.
Notice: Please make sure that you include in material submittal the required comparison sheet for all
lighting fixtures.
Notice: Please prepare (3 hard copies+ 3 soft copies) for each material submittals.
Dear Eng. Anas
Please prepare the several proposals for tunnel lighting calculation as we agreed to discuss this issue with
Dar Al Handasa in our next meeting with them.
Thanks for your cooperation.
Regards;
Ahmed Asaad
ABCD‐Technical Office
Mob: +966‐50234‐3211
Tel: +9662‐6165703/04 Ext. 3036
2
MAKKAH FIRST RING ROAD (J14-054)
Date: 07.04.2014
Operator: Eng. Anas Mahmoud
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Table of contents
Page 2
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Table of contents
Isolines (E) 42
Value Chart (E) 43
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHRED...
Planning data 44
Luminaire parts list 45
Street-valuation fields (list of coordinates) 46
GR Observer (Results Overview) 47
3D Rendering 49
False Color Rendering 50
Exterior Surfaces
Street-valuation field 1
Isolines (L) 51
Value Chart (L) 52
Isolines (E) 53
Value Chart (E) 54
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHRED...
Planning data 55
Luminaire parts list 56
Street-valuation fields (list of coordinates) 57
GR Observer (Results Overview) 58
3D Rendering 60
False Color Rendering 61
Exterior Surfaces
Street-valuation field 1
Isolines (L) 62
Value Chart (L) 63
Isolines (E) 64
Value Chart (E) 65
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHRED...
Planning data 66
Luminaire parts list 67
Street-valuation fields (list of coordinates) 68
GR Observer (Results Overview) 69
3D Rendering 71
False Color Rendering 72
Exterior Surfaces
Street-valuation field 1
Isolines (L) 73
Value Chart (L) 74
Isolines (E) 75
Value Chart (E) 76
Page 3
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can be
CIE flux code: 38 76 98 100 84 displayed for this luminaire.
Page 4
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can be
CIE flux code: 38 75 98 100 78 displayed for this luminaire.
Page 5
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Luminous emittance 1:
Luminaire classification according to CIE: 99 Due to missing symmetry properties, no UGR table can be
CIE flux code: 40 76 97 99 79 displayed for this luminaire.
Page 6
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can be
CIE flux code: 42 75 97 100 70 displayed for this luminaire.
SGX320 Tunnelite
Tunnel luminaire SGX320 suitable for use with SON-T 150-400W high pressure
sodium vapour lamps
Page 7
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can be
CIE flux code: 49 83 99 100 64 displayed for this luminaire.
SRX509
Underpass luminaire suitable for use with SON-T 150W, 250W, 400W high
pressure sodium vapour lamps.
Page 8
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can be
CIE flux code: 50 83 98 100 100 displayed for this luminaire.
Multi Mounted IP65 Tunnel LED Luminaire with Symmetrical Distribution installed with
90W LED Strip and electronic control gears.
Page 9
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can be
CIE flux code: 62 91 99 100 66 displayed for this luminaire.
IP65 Tunnel Lighting with 400W MH Lamp
Page 10
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Light loss factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) ) (Luminaire) [lm] ) (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
SAUDILIGHTING UP201S/3-400.SA TUNNEL LIGHT
2 320 22940 35000 400.0
(1.000)
Total: 8376754 Total: 12236512 138620.0
Page 11
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE / Luminaire parts list
Page 12
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
Page 13
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Scale 1 : 679
GR Observerlist
Page 14
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
GR Observerlist
2) The calculated equivalent veil luminance of the environment is based on the assumption of a complete diffuse reflection behavior of the environment (acc. EN 12464-2).
Page 15
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Page 16
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE / False Color Rendering
Page 17
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 18
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 19
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Grid: 15 x 3 Points
Rotation: 90.0°
Page 20
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
Grid: 15 x 3 Points
Rotation: 90.0°
Page 21
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 /
Planning data
Light loss factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) ) (Luminaire) [lm] ) (Lamps) [lm] P [W]
PHILIPS SRX509 1xSON-TPP400W SGR S (Type 1)*
1 320 22400 35000 433.0
(1.000)
SAUDILIGHTING 6444J/8 LED strips TUNNEL
2 118 8778 8784 90.0
LUMINAIRE (1.000)
*Modified Technical Specifications Total: 8203843 Total: 12236512 277180.0
Page 22
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 /
Luminaire parts list
Page 23
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / Street-
valuation fields (list of coordinates)
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
Page 24
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / GR
Observer (Results Overview)
Scale 1 : 679
GR Observerlist
Page 25
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / GR
Observer (Results Overview)
GR Observerlist
2) The calculated equivalent veil luminance of the environment is based on the assumption of a complete diffuse reflection behavior of the environment (acc. EN 12464-2).
Page 26
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / 3D
Rendering
Page 27
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / False
Color Rendering
Page 28
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / Street-
valuation field 1 / Isolines (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 29
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / Street-
valuation field 1 / Value Chart (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 30
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / Street-
valuation field 1 / Isolines (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 31
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SRX509 / Street-
valuation field 1 / Value Chart (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 32
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 /
Planning data
Light loss factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) ) (Luminaire) [lm] ) (Lamps) [lm] P [W]
PHILIPS SGX320 1xSON-TPP400W SGR (Type 1)*
1 320 24500 35000 433.0
(1.000)
SAUDILIGHTING 6444J/8 LED strips TUNNEL
2 118 8778 8784 90.0
LUMINAIRE (1.000)
*Modified Technical Specifications Total: 8875843 Total: 12236512 277180.0
Page 33
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 /
Luminaire parts list
320 Pieces PHILIPS SGX320 1xSON-TPP400W SGR (Type 1) See our luminaire catalog
Article No.: for an image of the
Luminous flux (Luminaire): 24500 lm luminaire.
Luminous flux (Lamps): 35000 lm
Luminaire Wattage: 433.0 W
Luminaire classification according to CIE: 100
CIE flux code: 42 75 97 100 70
Fitting: 1 x HQI-BT 400/D (Correction Factor 1.000).
Page 34
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / Street-
valuation fields (list of coordinates)
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
Page 35
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / GR
Observer (Results Overview)
Scale 1 : 679
GR Observerlist
Page 36
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / GR
Observer (Results Overview)
GR Observerlist
2) The calculated equivalent veil luminance of the environment is based on the assumption of a complete diffuse reflection behavior of the environment (acc. EN 12464-2).
Page 37
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / 3D
Rendering
Page 38
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / False
Color Rendering
Page 39
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / Street-
valuation field 1 / Isolines (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 40
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / Street-
valuation field 1 / Value Chart (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 41
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / Street-
valuation field 1 / Isolines (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 42
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using Philips SGX320 / Street-
valuation field 1 / Value Chart (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 43
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
Planning data
Light loss factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) ) (Luminaire) [lm] ) (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
SCHREDER AF4 / 1289 / HPS 400W / 972644 (Type 1)*
2 320 27578 35000 400.0
(1.000)
*Modified Technical Specifications Total: 9860912 Total: 12236512 266620.0
Page 44
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
Luminaire parts list
Page 45
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
Street-valuation fields (list of coordinates)
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
Page 46
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
GR Observer (Results Overview)
Scale 1 : 679
GR Observerlist
Page 47
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
GR Observer (Results Overview)
GR Observerlist
2) The calculated equivalent veil luminance of the environment is based on the assumption of a complete diffuse reflection behavior of the environment (acc. EN 12464-2).
Page 48
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
3D Rendering
Page 49
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
False Color Rendering
Page 50
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
Street-valuation field 1 / Isolines (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 51
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
Street-valuation field 1 / Value Chart (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 52
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
Street-valuation field 1 / Isolines (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 53
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/972644 /
Street-valuation field 1 / Value Chart (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 54
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
Planning data
Light loss factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) ) (Luminaire) [lm] ) (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
SCHREDER AF4 / 1400 / HPS 400W / 240041 (Type 1)*
2 320 27327 35000 400.0
(1.000)
*Modified Technical Specifications Total: 9780462 Total: 12236512 266620.0
Page 55
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
Luminaire parts list
Page 56
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
Street-valuation fields (list of coordinates)
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
Page 57
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
GR Observer (Results Overview)
Scale 1 : 679
GR Observerlist
Page 58
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
GR Observer (Results Overview)
GR Observerlist
2) The calculated equivalent veil luminance of the environment is based on the assumption of a complete diffuse reflection behavior of the environment (acc. EN 12464-2).
Page 59
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
3D Rendering
Page 60
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
False Color Rendering
Page 61
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
Street-valuation field 1 / Isolines (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 62
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
Street-valuation field 1 / Value Chart (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 63
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
Street-valuation field 1 / Isolines (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 64
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/240041 /
Street-valuation field 1 / Value Chart (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 65
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
Planning data
Light loss factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:930
No. Pieces Designation (Correction Factor) ) (Luminaire) [lm] ) (Lamps) [lm] P [W]
SAUDILIGHTING 6444J/8 LED strips TUNNEL
1 118 8778 8784 90.0
LUMINAIRE (1.000)
SCHREDER AF4 / 1400 / HPS 400W / 200681 (Type 1)*
2 320 29390 35000 400.0
(1.000)
*Modified Technical Specifications Total: 10440579 Total: 12236512 266620.0
Page 66
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
Luminaire parts list
Page 67
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
Street-valuation fields (list of coordinates)
Scale 1 : 679
No. Designation Position [m] Size [m] Viewing direction [°] Grid
X Y Z L W
1 Street-valuation field 1 10.000 50.000 0.100 50.000 10.950 90.0 15 x 3
Page 68
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
GR Observer (Results Overview)
Scale 1 : 679
GR Observerlist
Page 69
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
GR Observer (Results Overview)
GR Observerlist
2) The calculated equivalent veil luminance of the environment is based on the assumption of a complete diffuse reflection behavior of the environment (acc. EN 12464-2).
Page 70
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
3D Rendering
Page 71
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
False Color Rendering
Page 72
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
Street-valuation field 1 / Isolines (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 73
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
Street-valuation field 1 / Value Chart (L)
Grid: 15 x 3 Points
Observer Position: (10.000 m, -35.000 m, 1.600 m)
Viewing direction: 90.0 °
tarmac: R3, q0: 0.070
Page 74
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
Street-valuation field 1 / Isolines (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 75
MAKKAH FIRST RING ROAD (J14-054)
MAKKAH FIRST RING ROAD (J14-054) 07.04.2014
QUSHASHIAH Tunnel Sample (100M) Stage 1 THRESHOLD ZONE Using SCHREDER AF4/200681 /
Street-valuation field 1 / Value Chart (E)
Grid: 15 x 3 Points
Rotation: 90.0°
Page 76