Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 7

EIM ASSESSMET

1. What is commonly used minimum b. Poisoning


size of conduit in laying-out luxury c. Theoretical knowledge
devices? d. Personal safety
a. ¾” diameter 9. In boring 1/2 “diameter hole in panel
b. ½” PVC molding board, what type of hand tools is
c. ¾” diameter commonly used?
d. ½” diameter a. Hand drill
2. Cells are connected in parallel to b. Knock-out Puncher and
_________. adjustable wrench
a. Increase the internal resistance c. Hacksaw and hammer
b. Decrease the current capacity d. Cold chesil and hammer
c. Increase the current capacity 10. A small light bulb with a resistance
d. Increase the output voltage of 2400 ohms is connected across
3. Which of the following is the output 120v source, the line current is
device? ______?
a. Biometric reader and controller a. 0.05 A
b. Door lock b. 2A
c. Exit button c. 20A
d. All of the above d. None of the above
4. A device used to measure the 11. What is the reason why the end of
diameter of the wire is _________? wire should pass around the screw in
a. Wire stripper the same direction as the screw is
b. Wire splicer tuned when tightening a terminal
c. Wire gauge screw connection with the splice
d. Wire nut wire?
5. The average dry cell gives an a. The wire will not turn off
appropriate voltage of______? b. The screw can be removed more
a. 1.7 easily
b. 1.1 c. Any pull on the wire will tighten
c. 1.5 the screw
d. 1.3 d. The wire will act as a locknut
6. What kind of diagram used to 12. What is the most advantage using
designing or troubleshooting rubber insulation tape in splice?
electrical installation control a. Does not absorb much moisture
equipment arranged to facilitate the b. Is able to withstand high
tracing of circuit? temperature
a. Pictorial drawing c. Does not deteriorate with age
b. Wiring diagram d. All of the above
c. Electrical lay-out 13. Why is that insulation should be
d. Schematic diagram “pencil down” rather than to cut
7. It is an electrical parameter applied square when skinning a small wire?
on labeled to all kind of switches. a. Allows more insulation in the
a. Rated current and rated splice
voltage b. Decrease danger of nicking the
b. Rated power and rated wire
voltage c. Prevent the braid from fraying
c. Rated resistance and rated d. Saves time in making the splice
current 14. Connection, locknut, and bushing are
d. Rated power and rated called electrical______?
current a. Expander
8. When using any instruments for b. Tighteners
measuring or testing an electrical c. Conduit
circuit, one should consider first - d. Fittings
________? 15. How much current is produced by
a. Clothing 40v across 10k resistance?
a. 0.4 A 23. It is a mechanical connector that is
b. 4A crimped unto a conductor for both
c. 0.04A splice and termination.
d. None of the above a. Bolt connector
16. In service entrance, the commonly b. Solderless connector
conduit is ? c. Mechanical lug
a. Flex conduit d. Split bolt connector
b. PVC 24. For joining PVC conduit, what
c. EMT commonly adhesive materials is
d. PSC/IMC being used?
17. The most important reason why an a. PVC solvent
electrician should always have his b. PVC varnish
tools in good working condition is? c. PVC adhesive
a. It is part of your job to keep tools d. PVC cement
in good working condition 25. In 40 A motor full load current, what
b. Your job cannot be satisfactory size of circuit breaker should be
done without good tools used?
c. Defective tools can cause a. Equal to 100AT
accidents or damage to b. Not less than 125% of the full
equipment load
d. You have to exert more effort c. Less than 50AT
when using defective tools d. More than 115% of the full load
18. By cutting______, a live duplex wire 26. An ammeter is connected _______
can be de-energized quickly and when measuring load current.
safety. a. In series with the load
a. Across with electrical pliers b. Across the terminal of the load
b. One by one with a knife c. From one load terminal to
c. One by one diagonal cutter ground
d. Across using a mechanical plier d. Parallel with the load
19. How much current flow in a filament 27. What is the ideal resistance of a wire
of a 80W bulb connect to a 110 V when measured at both ends?
line? a. 5 ohms
a. 0.5 A b. 50 ohms
b. 0.727A c. Infinity
c. 1.2A d. Depends on the type of wire
d. None of the above 28. The ohmmeter is connected______-
20. It is a fitting resembling a pipe or when measuring load resistance.
box with a removable cover access to a. Parallel with the source
electric conduit. b. Across the terminal load
a. Connector c. From load terminal to ground
b. Conduit strap/cramp d. In series with the load
c. Locknut and bushing 29. What current will be drawn by an
d. Condulet incandescent lamp labeled at 30W
21. What is a power in a circuit where and 110V?
the source produce 5A in a 20ohms A. 0.23 amps.
resistance? B. 2.7amps.
a. 500W C. 2.3 amps
b. 400W D. 0.27 amps
c. 300W 30. What is PPE?
d. None of the above A. Power Purchased equivalent
22. What type of box is used for B. Personal Properly Equipment
convenience outlet? C. Power Panel Enclosure
a. Square box D. Personal Protective Equipment
b. Pull box 31. 60 ohms resistors is connected in
c. Splice box parallel with another 6 ohms, the
d. Utility box equivalent resistance would be
_________?
a. 12 ohms
b. 6 ohms 39. Make sure circuit is _______when
c. 3 ohms measuring resistance with multi
d. None of the above tester?
32. The ampacity of #8.0 aq.mm. THW a. Open or de-energized
wire is? b. Closed and energize
a. 50 amperes c. Under grounded
b. 25 amperes d. Grounded
c. 20 amperes 40. A circuit breaker is an electrical
d. 35 amperes protective device which ______?
33. A wire stripper is used to ________? a. Breaks power flow when every
a. Remove wire insulation low voltage is encountered
b. Clean wire terminals b. Protects electrical equipment
c. Measure wire size from incoming spike voltage
d. Cut wire to exact length c. Trips off when every low current
34. Threes resistors pf 4,3 and 2 ohms is encountered
are connected in series across 18v d. Protects electrical equipment
source. How much will current will from current surges and
flow? overload
a. 6A 41. It is necessary that the source is
b. 0.4 A _______ when measuring ballast
c. 3A resistance if it is defective or good.
d. 2A a. Unloaded
35. If the load schedule reflects a b. De-energized
20AT/2.0sq.mm. Lighting Branch c. Loaded
Circuit of which circuit breaker is d. Energized
Overrated, what will you do? 42. The proper measuring of an
a. Change rating to 15AT to unknown voltage with multi-tester is
conform with PEC requirements _______.
b. Wait for your superior and let a. Start measuring at the highest
him do the corrections range
c. Look for wiring layout and check b. Start measuring at the mid-range
grouping c. De-energize the circuit
d. Look another load schedule and d. Start measuring the lower range
check for difference 43. What connection is between the
36. All switches that have been turn off grounded circuit conductor and the
before doing work on any electrical equipment grounding conductors at
equipment should be _____? the service?
a. Left with a note a. Bonding jumper, main
b. Left as it is b. Bonding jumper, equipment
c. Left with cover and padlock c. Bonding jumper
d. Left with cover open d. Grounding electrode conductor
37. An incandescent bulb was connected 44. Which of the following below is an
to a 115-volt circuit with a resistance output device?
of 264.5 ohms , what amount of a. Exit button
current will be drawn by the bulb? b. Emergency break glass
a. 0.45 amps c. Magnetic look
b. 0.43 amps d. Biometric reader and control
c. 0.42 amps 45. Transformer used to change value of
d. 2.3 amps ______?
38. What sheet metal though with hinge a. Frequency
or removable covers for housing and b. Power
protecting electrical wires and cables c. Voltage
and in which conductors are laid in d. Power factor
place? 46. THW wires are mostly in industrial
a. Cable trays wirings, the technical term for THW
b. Cable ducts is _____?
c. Bus ways a. Plastic covering
d. Wire ways b. Poly Vinyl Chloride
c. Moisture and Hear Resistant contacts with live parts in any
Thermoplastic direction.
d. PVC insulated Heat Resistant a. Switch gear
47. Commonly used types of fittings for b. Enclosure
tightening between the boxes and the c. Cabinet
circuit is ____? d. Panel board
a. Lock nut and bushing 56. It is an accessory such as bushing
b. Straight connector and access fittings which serve to
c. Condulet complete a conduit system
d. Conduit strap a. Sleeve
48. Equivalent size in English system of b. Bonding jumper
38 square millimeter wire. c. Threaded connector
a. # 4 AWG d. Conduit fitting
b. #2 AWG 57. When the size of the conductor is
c. #1.0 AWG specified in the square millimeter, it
d. 1/0 AWG s usually
49. In series circuit the ____ is constant. a. Stranded conductor
a. Voltage b. Solid conductor
b. Current c. Aluminum conductor
c. Resistance d. Copper conductor
d. None of the above 58. What is a point in the wiring system
50. What type of box is used for typical at which current is taken to supply a
switches? utilization system?
a. Pull box a. Jumper connection
b. Splice box b. Convenience outlet
c. Utility box c. Branch circuit
d. Square box d. Feeder cuircuit
51. The average wire gauge (AWG) size 59. You will use _______ mechanical
2.0 mm square is rather than an electrical function to
a. #18 make a 90 degrees bend in conduit
b. #10 installation.
c. # 12 a. Reducer
d. #14 b. Offset
52. Secondary current of 200 ampere c. Bending
flows from a transformer with a turn d. Elbow
ratio of 10:1 the primary current is 60. Commonly used fitting for tightening
_____amperes. between the boxes and DSC conduit.
a. 2 a. Locknut and bushing
b. 20 b. Condule
c. 200 c. Straight connector
d. 2000 d. Conduit strap
53. A portable grinder is considered 61. What is technical term for type TW
a______? wires used in building wirings?
a. Power tool a. Plastic
b. Plumbing tool b. PVC insulated resistance
c. Hydraulic tool c. Moisture resistance
d. All of the above d. Polyethylene insulated
54. The electrical that changes the 62. Which of the following materials is
magnitude of currents is? the best insulator of electricity?
a. Ammeter a. Rubber
b. Voltage transformer b. Porcelain
c. Current transformer c. Glass
d. Capacitor bank d. Paper
55. It is part of providing an appropriate 63. When two 5 ohms resistors
degree protection of equipment connected in parallel their total
against external influence and resistance is ______?
defined degree of protection against a. Ohms
b. 15 ohms
c. 10 ohms b. Decrease danger of nicking the
d. 2.5 ohms wire
64. Which of the following below is an c. Prevent the braid from fraying
input device? d. Saves time in making splice
a. Biometric reader and controller 73. In series circuit the ________ is
b. Door lock constant.
c. Exit button a. Voltage
d. All of the above b. Resistance
65. The unit of electrical potential is c. Power
_______? d. Current
a. Volts 74. What is the part of a auxiliary device
b. Amperes of CCTV that captures lives events
c. Ohms and saves video files?
d. Watts a. Monitor
66. The number of cycles that occurs in b. Camera
one second is known as ________? c. Recorder
a. Period d. Power splitter
b. Wave form 75. 500 ohms is equal to
c. Wave period a. 0.5 mega ohms
d. Frequency b. 5.00 mega ohms
67. What is the 24 hour protection to c. 0.5 kilo ohms
monitor and access the video for d. 50.0 kilo ohms
home and commercial building 76. A wire is properly connected to a
anytime anywhere on this device? terminal lug using
a. Telephone monitoring cabinet a. Long nose plier
b. Fire alarm system b. Crimping tools
c. CCTV Camera c. Screwdriver
d. Building remote controller d. Ballpen hammer
68. What is the standard height of switch 77. The standard color use as ground
from above finish floor line? wire is
a. 1.8 m a. Blue
b. 6 ft b. Yellow
c. 150 cm c. White
d. None of the above d. Green
69. Standing height of an outlet from
above finish floor line is________
What are the different types of conduits?
a. 0.5 m
b. 0.8 m Ans. The different types of conduit
c. 0.4 m commonly used for building wirings are:
d. 30 cm
70. What auxiliary device of CCTV that  Metallic non-flexible conduit-such as
motion daily? RMC,IMC,EMT,RSC Conduit
a. Camera  Metallic flexible conduit
b. Adapter  Non-metallic-nonflexible conduit
c. Monitor such as PVC conduit
d. Recorder  Non-metallic conduit
71. It is a part of the camera auxiliary What is the purpose of providing pull
system for each camera that set the boxes and gutter?
motion-trigger action individually.
a. Motion detection  For the purpose of cable pulling,
b. Recording splicing, and termination of wires.
c. Live previewing Name at least 3 types of personal
d. Camera scheduled protective required to be worn on most
72. Why is it insulation should be jobs.
“pencil down” rather that to cut
square when skinning a small wire? Answer:
a. Allows more insulation in the  Hard hot
splice
 Safety gloves What do you mean by “ PEC”
 Safety shoes
 Philippine Electrical Code
 Goggles apron
What is the purpose of using electrician
What will you do if the installation
knife instead of electrician piers?
manual for installing selector switch is not
 The purpose of using electrician available?
knife is to avoid nicking of wires or
 If you are not familiar with the
lessen the number of strands that will
installation/replacement of the
cause the wires heat-up.
selector switch, do not attempt to do
In standard practice, rubber tape is it
commonly used insulating bared  Bring the matter to your immediate
conductor especially outdoor installation supervisor and ask for assistance
for the purpose of what?
 It is increased to be use rubber tape A portable grinder is considered as what
for insulating bared conductor first kind of tool?
because it does not absorb much
 Portable grinder is a type of power
moisture when exposed.
tool
As a safety measure, why is it not
advisable to use water in extinguishing
Explain how grounding system can
electrical fires?
prevent someone from receiving an
electric shock?
 The main reason is that water may
 Grounding system has a low
transmit shock to the user.
resistance compared to the body, if
What is the best move in using power there is ground current, the current
tools during installation? will tend to flow to the lower
resistance, thereby preventing
 Inspect and test if the power tool are
someone from receiving a shock.
in good condition or safe use.
How do you protect the electrical
Give/ name at least 5 examples of fittings system from lighting?
used in installing conduits.  Install transient voltage surge
suppressor or lighting arrester.
 Locknut
 Bushing Explain why fuse and circuit breakers
 Straight connector cannot use solely to protects against
 Condulet overload?
 Coupling
 Fuses and circuit breakers sense the
 Conduit strap
branch circuit current. If there is an
overload, fuses and circuit breakers
What do you mean by enclosure? may not trip and will damage the
load.
 A part of providing an appropriate
degree of protection of equipment
against contains external influences What is the advantage of digital meter
and defined degree against contacts over an analog meter?
with live parts in any direction.
 A digital meter is more accurate than
analog meter due to its electronics
What are the types of services applied in components
building?  Easy to calibrate and more reliable

 Service drop
 Service entrance conductor What is the common cause of electric
 Service equipment drill’s breakdown?
 Worn-out carbon brush is the  door luck
common cause of electric drill’s  control system panel
breakdown.  biometric reader and controller
 exit button
What is the purpose of installing GFCI
outlet?
 GFCI outlets are usually installed in what is the function of motion detection in
wet locations where a person may CCTV?
experience electric shock. this is
 It is part of auxiliary system that the
because the purpose of the GFCI
set of the motion-trigger action
outlet is to turn off the way the
individually for each camera
power if there is any risk of an
electric shock close to a water
source.
What do you mean by wiring diagram
Identify the basic components of lighting in auxiliary device system?
protection system.
 A diagram that show location and
 Lighting terminal actual termination of auxiliary
 Down conductors devices
 Grounding rod
What is the acronym of “VOM” multi-
tester?
 V-voltmeter
 O-ohm-meter
 M-milli-meter

What are the different components of fire


alarm system?
 Fire alarm control panel
 Smoke detector
 Heat detector
 Fire alarm bell
 Manual pull station
What are the basic components of closed
circuit television system?
 Closed circuit camera
 Tv mpnitpr
 Sequential switch
 CCTV adapters/splitters
 DVR

What is video entry phone?


 Video entry phone is a
communication device which is
allow as the person to identify a
visitor trough picture image in a
monitor

Name the four major parts of door access


control system?

You might also like