Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

AIR INLET

HUMIDITY‑CONTROLLED, ACOUSTIC
Wall vent for Ø 100 or 125 mm holes

EM HY
5/45 m³/h
CERTIFIED

ACOUSTIC

CIRCULAR HOLE

w w w . a n j o s - v e n t i l a t i o n . c o m
EM HY
Used in MEV systems type Hygro B (Atech ALIZÉ 2018), the window inlet EM HY is used
in association with humidity-controlled and temporized exhaust valves.

IMPORTANT
• Sound attenuation (external wall): 30 dB(A) (EM HY 125) to 35 dB(A) (EM HY100)
• The air inlet and grille fit in externally or internally insulated walls
• Hole diameters: 100 or 125 mm
• Made of white polystyrene

VENTILATION HYGROREGLABLE

PRESENTAT I O N www.certita.fr

EM HY indoor air vents ensure a variable flow rate of 5 to Acoustic performance: Dn,e,w + Ctr ≥ 39 dB, required if
45 m³/h depending on room humidity levels and for a the square meterage of a room divided by the number of
20 Pa pressure difference. air inlets is less than 10 m².
Acoustic performance for 30 dB sound attenuation
(external wall):

OUTDOORS

EM HY Humidity-controlled air inlet: Ø 100 (EM HY 100) or Ø 125


(EM HY 125).
Made of white polystyrene.
Flow rate: 5 to 45 m³/h
L. (mm) H. (mm) Thk. (mm)
220 150 52

MMM Metal sleeve: Ø 100 (MMM 100), or Ø 125 mm (MMM


125). Length: 300 mm.
L. (mm) Diameter Ø
300 100 or 125

INDOORS

GAP External grille: Ø 100 (GAP 100) or Ø 125 (GAP 125).


Made of UV-resistant and weather-resistant white
polystyrene.
L. (mm) H. (mm) Thk. (mm)
150 150 20

For sound attenuation greater than 35 dB (external wall), refer to the


Anjos's documentation on the SC silencer.
INS TAL L AT I O N

Drill a hole in the wall with a slight outward slope. GAP grille adapter and clip the grille onto the outdoor
Insert the 100 mm (ID: 100 mm max/97 mm min) end of the sleeve.
or 125 (ID: 125 mm max/122 mm min) sleeve and Insert the air inlet into the indoor side of the sleeve. The
apply caulking around the circumference of the sleeve. inlet is held in place by an airtight lip seal.
Outdoors, once the wall coating is finished, screw on the

2
1 EM HY
2 MMM
1
3 GAP

I N S TA L L AT I O N E X A M P L E S

Installation example: 300 mm wall and Ø 125 mm hole

External insulation Internal insulation


CHAR AC T ER I ST I C S

AIR FLOW

60
The curve opposite shows the nominal air characteristics
as a function of humidity level of the indoor air and for a
20 Pa pressure difference.
40
Airflow in m³/h

20

0
0 20 40 60 80 100
Relative humidity HR %

ACOUSTIC
60
Air inlets are characterised by their acoustic performance
50
50 Dn,e,w(Ctr).

40 Type Dn,e,w (C) Dn,e,w (Ctr)


EM HY 100 + GAP grille 100 40 dB 39 dB
30 40
EM HY 125 + GAP grille 125 40 dB 39 dB
dB

20
Débit en m 3/h

endB
Dn,e in

10
Dn,e

0 30

0 20 40 60 80 100 125 250 500 1000 2000 4000


Humidité relative HR % EM HY + GAP Fréquence
Frequency en Hz
in Hz EM HY100 EM HY125

TEST REPORTS

Technical Opinion on humidity-controlled MEV systems. courbes rapport anjos du 7/10/2016

Lw dB

PRODUCT CODES 48

Description Code Description Code


EM HY 100 2201 External grille Ø 100 GAP 100 2204
38
EM HY 125 2202 External grille Ø 125 GAP 125 2205
Metal sleeve MMM 100 – Ø 100, L: 300 mm 2210
Metal sleeve MMM 125 – Ø 125, L: 300 mm 2212
January 2019 – Non-contractual document;

28
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
2150
4000
5000

Fréquence (Hz)

DISPLAY OF
PERFORMANCE
Products marked with this logo
comply with the performance display
recommendations defined by Uniclima

01230 Torcieu – France – Tel. +33 (0)4 74 37 44 44 – Fax +33 (0)4 74 36 20 60 – www.anjos-ventilation.com

You might also like