Professional Documents
Culture Documents
The Key Elements of The WDM System
The Key Elements of The WDM System
The Key Elements of The WDM System
2. Connection loss There are two types of connection loss: fixed connection loss is
generated when optical fibers are directly spliced. Activity loss is generated on the ODF
or other active adapters. 3. Insertion loss of the board Indicates the loss generated
when the board hardware processes the optical model of the WDM equipment.
How to improve the optical power performance of a WDM
system?
1. Use high-quality optical cables.
2. Use optical modules with better performance. Increase the optical output power and
increase the threshold range of the received power.
3. Minimize artificial optical power attenuation. When laying optical fibers and optical
fibers and optical cables, reduce or avoid bending of optical fibers (The bending radius
of a common optical fiber must be greater than 0.03 m, that is greater than 3 cm. The
bending radius of an optical fiber cannot be less than 20 times the outer radius of the
cable) squeezing and moving connectors must not be loose.
4. Use the optical amplifier (OA) to compensate for the power. For more information,
read the rest of this post.
Optical power budget in WDM network design
1. Calculation formula
Fiber Loss(dB) = Pout (dBm) - Pin (dBm) = L (km) x ac (dB/km), ac: damping
coefficient.
G.652 and G.655 fibers at 1550nm window: a = 0.22dB/km (Usually,
0.2dB/km-0.3dB/km, The default fiber attenuation coefficient is 0.22 dB/km.)
G.652 and G.655 fibers at 1310nm window: a = 0.36dB/km (Usually,
0.3dB/km-0.4dB/km)
Generally, We set a 3dB fiber margin for each OTS span in network design.
If the optical supervisory channel (OSC) is used, consider the extra power of fiber line
units, which is considered 1 dB (the insertion loss of the FIUs at the two ends) in the
budget.
In the WDM network design, if the customer provides only the fiber distance and fiber
type but does not provide other parameters:
Line attenuation = Fiber length x 0.22 dB/km Default fiber attenuation coefficient +
3 dB fiber aging margin + Fiber switching site attenuation + FIU insertion
loss. The attenuation of a fiber transfer station = 0.5 dB/site. If no fiber transfer station
is available, this parameter is not required.
Example: If the fiber length between A and B is 90 km, the default fiber attenuation
coefficient is 0.22 dB/km, the fiber aging margin is 3 dB, and there are two fiber hop
sites, the attenuation is 0.5 dB/site, and the FIU insertion loss is 1 dB.
According to the preceding formula, the line attenuation can be calculated as follows:
Line attenuation = 90 km x 0.22dB/km + 3 dB + 2 x 0.5 dB + 1 dB = 24.8 dB
2. Optical amplifier (OA)
The optical amplifier (OA) is a component that can directly amplify optical signals
without optical-electrical-optical conversion, that is, a component that does not perform
optical-electrical conversion on colored optical signals on a line but performs signal
amplification. A measure of the amplification degree of an optical amplifier is called
gain.
Gain (dB) = Output optical power Pout (dBm) - Input optical power Pin (dBm).
The OA board consists of the OBU/OAU/HBA/RAU board. The logical structure of the
OA board is as follows:
The OAU is a bipolar amplifier. The RAU integrates the Raman amplifier with the OAU
amplifier.
3. What are the basic principles of OA configuration?
a. Ensure that the receiver sensitivity requirements are met. (After being transmitted,
the transmit light of the OTU reaches the receiving end of the OTU, and the receiving
end meets the sensitivity requirement of the receiving end.)
b. Ensure that the output optical power is locked and the OSNR of the system is
available.
c. The OA cost is optimal when the optical power budget is met.
d. Amplifiers are selected based on different gain coverage and output optical power
requirements. Gains include compensation for channel attenuation and attenuation
introduced by the dispersion module.
e. For the same project or customer group, the fewer amplifier types, the better.
4. What is the general sequence for selecting amplifiers?
a. Single-stage amplifiers take precedence over dual-stage amplifiers. (OBU is a single-
stage amplifier, and OAU is a dual-stage amplifier.)
b. Dual-stage amplifiers take precedence over two single-stage amplifiers.
c. Common power amplifiers take precedence over high-power amplifiers.
d. OAU05 /07 (+7 dBm/23 dBm) takes precedence over Raman amplifiers.
e. Raman amplifiers take precedence over HBA amplifiers.
5. What is the OA selection sequence in a coherent system?
a. Coherent OAs are preferred for coherent systems to provide the best performance.
b. Single-stage amplifiers take precedence over dual-stage amplifiers. Two-stage
amplifiers are preferred over two single-stage amplifiers for the best cost.
c. Common power amplifiers take precedence over high-power amplifiers.
d. If common OAs meet requirements, do not configure high-power or RAU OAs.
e. Newly deployed network: When the OSNR budget is insufficient, RAU is used to
improve the OSNR and reduce the number of regeneration boards.
Example: Configure optical amplifiers for each site of the following images.
Analysis:
1. Common Systems (For example, 40, 80, 96, 120, etc.) Both have requirements on
the single-wavelength nominal output of optical amplifiers, which is also called incident
optical power. For details, see the product documentation.
2. After the nominal output requirements are met, calculate the required gain range of
the optical amplifier based on the insertion loss of each component and determine the
type of the amplifier. Note that the amplifier with a small noise figure is preferred to
obtain better OSNR when the gain is met.
The reference solution is as follows:
La puissance optique est exprimée en milliwatts (mW) et en décibels milliwatts (dBm). Elles peuvent être
converties comme suit : dBm=10xlgP. Ici, P indique la puissance optique, en mW.
L'atténuation des signaux optiques de différentes longueurs d'onde dans la fibre G.652 est la suivante :
optique
2. Perte de connexion Il existe deux types de perte de connexion : la perte de connexion fixe est générée
lorsque les fibres optiques sont directement épissées. La perte d'activité est générée sur l'ODF ou
d'autres adaptateurs actifs. 3. Perte d'insertion de la carte Indique la perte générée lorsque le matériel
de la carte traite le modèle optique de l'équipement WDM.
2. Utilisez des modules optiques plus performants. Augmentez la puissance de sortie optique et
augmentez la plage de seuil de la puissance reçue.
4. Utilisez l'amplificateur optique (OA) pour compenser la puissance. Pour plus d'informations, lisez la
suite de ce billet.
Perte de la fibre (dB) = Pout (dBm) - Pin (dBm) = L (km) x ac (dB/km), ac : coefficient d'amortissement.
En général, nous définissons une marge de fibre de 3dB pour chaque portée OTS dans la conception du
réseau.
Si le canal de supervision optique (OSC) est utilisé, il faut considérer la puissance supplémentaire des
unités de ligne de fibre, qui est considérée comme 1 dB (la perte d'insertion des FIUs aux deux
extrémités) dans le budget.
Dans la conception du réseau WDM, si le client ne fournit que la distance et le type de fibre mais ne
fournit pas d'autres paramètres :
Atténuation de la ligne = Longueur de la fibre x 0,22 dB/km Coefficient d'atténuation de la fibre par
défaut + marge de vieillissement de la fibre de 3 dB + atténuation du site de commutation de la fibre +
perte d'insertion des CRF. L'atténuation d'une station de transfert de fibres = 0,5 dB/site. Si aucune
station de transfert de fibre n'est disponible, ce paramètre n'est pas nécessaire.
Exemple : Si la longueur de la fibre entre A et B est de 90 km, le coefficient d'atténuation de la fibre par
défaut est de 0,22 dB/km, la marge de vieillissement de la fibre est de 3 dB et il existe deux sites de saut
de fibre, l'atténuation est de 0,5 dB/site et la perte d'insertion de la CRF est de 1 dB.
fibre
Selon la formule précédente, l'atténuation de la ligne peut être calculée comme suit : Atténuation de
ligne = 90 km x 0,22dB/km + 3 dB + 2 x 0,5 dB + 1 dB = 24,8 dB.
Gain (dB) = Puissance optique de sortie Pout (dBm) - Puissance optique d'entrée Pin (dBm).
fibre optique
L'OAU est un amplificateur bipolaire. Le RAU intègre l'amplificateur Raman avec l'amplificateur OAU.
b. Assurez-vous que la puissance optique de sortie est verrouillée et que l'OSNR du système est
disponible.
c. Le coût de l'OA est optimal lorsque le budget de puissance optique est respecté.
d. Les amplificateurs sont sélectionnés en fonction des différentes couvertures de gain et des exigences
de puissance optique de sortie. Les gains comprennent la compensation de l'atténuation du canal et de
l'atténuation introduite par le module de dispersion.
e. Pour un même projet ou groupe de clients, moins il y a de types d'amplificateurs, mieux c'est.
b. Les amplificateurs à deux étages sont prioritaires par rapport à deux amplificateurs à un étage.
c. Les amplificateurs à puissance commune sont prioritaires sur les amplificateurs à puissance élevée.
d. L'OAU05 /07 (+7 dBm/23 dBm) a la priorité sur les amplificateurs Raman.
b. Les amplificateurs à un étage ont la priorité sur les amplificateurs à deux étages. Les amplificateurs à
deux étages sont préférés à deux amplificateurs à un étage pour le meilleur coût.
c. Les amplificateurs à puissance commune ont la priorité sur les amplificateurs à haute puissance.
d. Si les OA communs répondent aux exigences, ne configurez pas d'OA haute puissance ou RAU.
e. Réseau nouvellement déployé : Lorsque le budget OSNR est insuffisant, le RAU est utilisé pour
améliorer l'OSNR et réduire le nombre de cartes de régénération.
Exemple : Configurez des amplificateurs optiques pour chaque site des images suivantes.
fibre optique
Analyse :
1. Systèmes communs (par exemple, 40, 80, 96, 120, etc.) Les deux ont des exigences sur la sortie
nominale à longueur d'onde unique des amplificateurs optiques, qui est également appelée puissance
optique incidente. Pour plus de détails, voir la documentation du produit.
2. Une fois les exigences de sortie nominale satisfaites, calculez la plage de gain requise de
l'amplificateur optique en fonction de la perte d'insertion de chaque composant et déterminez le type
d'amplificateur. Notez que l'amplificateur avec un faible facteur de bruit est préférable pour obtenir un
meilleur OSNR lorsque le gain est satisfait.
fibre optique