42LSA - Manual Del Usuario
42LSA - Manual Del Usuario
Split
Console &
Underceiling
" ENGLISH/ESPAÑOL"
NOTA: Las Instrucciones en Español
Empiezan en la Página 20.
Index Cong ratulations
on your
Getting to know
We at United Technologies are quite satisfied to have you as ar our Carrier Split
your Split Console & 3
Underceiling
Console & Underceiling Unit user.
choice
Installation 5 We can assure you have purchased high technology, energy-saving, long-
lasting equipment.
Safety Instructions 6
For best results, it is paramount that you follow the instructions on this manual.
Join us through the last page and have a better understanding of why we invest so
Important Tips 7
much in state-of-the-art technology.
Getting to know
the wired 9
remote control
Getting to know
the wireless 13
remote control
Cleaning
and care
17
Troubleshooting
18 Because our service is focused on you!
guide
INSIDE UNIT
Getting to know your Split
Console and U nderceiling U nit
(kg)
weight (kg)
Inside Unit
NetWeitght
WxHxD
Control
Wireless
Sizes
Remote
Remote
(mm)
Control
Control
Panel
Wired
Deflector Switches Air filters
Net
42LSA12226 CL CW 1000 X 635 X 265 / 275 16,5
42LSA18226 CL CW 1000 X 635 X 265 / 275 22,0
Remote control 42LSA24226 CL CW 1380 X 635 X 265 / 275 28,5
42LSA30226 CL CW 1380 X 635 X 265 / 275 28,5
Interconnection piping 42LSA36226 CL CW 1760 X 635 X 265 / 275 39,5
and wiring 42LSA42226 CL CW 1760 X 635 X 265 / 275 39,5
(not supplied) 42LSA48226 CL CW 1760 X 635 X 265 / 275 39,5
42LSA60226 CL CW 2140 X 635 X 265 / 275 47,0
Air
intake
OUTSIDE
Operation (*)
Tension (V)
breaker (A)
Current (A)
(V-Ph-Hz)
Nominal
capacity
(BTU/h)
UNIT
Speeds
Air flow
Circuit
(m³/h)
Air 12000 208/230 - 1 - 60/50 0,60 10 680 3 C/HP
discharge 18000 208/230 - 1 - 60/50 0,70 15 800 3 C/HP
Drain 24000 208/230 - 1 - 60/50 0,83 15 1.100 3 C/HP
OPTION 1 30000 208/230 - 1 - 60/50 0,79 20 1.400 3 C/HP
36000 208/230 - 1 - 60/50 1,50 30 1.650 3 C/HP
42000 208/230 - 1 - 60/50 1,70 25 1.650 3 C/HP
48000 208/230 - 1 - 60/50 1,70 25 2.150 3 C/HP
60000 208/230 - 1 - 60/50 1,70 25 2.200 3 C/HP
(*) C: Cooling
HP : Heat Pump
OPTION 2 OPTION 4
OPTION 3 3
Air conditioners such as the Split Console & Underceiling Unit require
Installation
a more special and higher-quality installation, since the system must
be supplemented with copper tubes, electrical wires, etc. Such items
are NOT included with the indoor or outdoor unit, as their sizes and
quantities vary according to the installation site features.
To make sure that this task is safety and correctly accomplished, we
have a chain of factory-trained, authorized companies to provide you
with the comfort of hiring a technically reliable installer.
We suggest that you compare installation costs (interconnection parts
and service) only among air-conditioner service companies.
4
Safety Use the equipment only on the indicated voltage on the
identification plate.
!
Instructions No electrical appliance should ever be touched by children,
even when it is turned off.
If there is any damage on the electric parts of either unit, turn off
the breaker immediately and do not attempt to repair them. Call
an authorized company to do the maintenance.
5
Keep the air intake or outflow openings clear on the indoor or
Im portant
outdoor units. Obstructing them will result in low performance
and may damage the equipment. !
tips
Always check whether the adjusted temperature on the
thermostat is adequate for the comfort of the persons in the
room.
8
6
In case of electrical power failure, turn off your Split Console &
Underceiling Unit immediately and turn it on again only 1
minute after electrical power returns. This precaution will
prevent the tension oscillations which may burn the
compressor.
Make sure that the indoor unit is at least 1 meter away from any
electrical appliance, or there may be interference on the
7
8
1
By pressing the ON/OFF button on the wired
remote control you can turn your Split Console & Getting to know the
Underceiling Unit on and off.
2
By positioning the MODE switch you can select
wired remote control
the desired operation mode.
COOLING
On COOL mode the equipment will bring the room
temperature down to the temperature you have
set, between 18 and 30°C. Turn the
TEMPERATURE knob to select what you consider
COOLING to be the optimum temperature. On FAN mode,
& HEATING
only the indoor unit fan works, circulating the
ambient air. On this mode you have no control
over the room temperature. On HEAT mode the
equipment brings the temperature up to the
temperature you have set, between 18 and 30°C.
Turn the TEMPERATURE knob to select what you
consider to be the optimum temperature. The
HEAT option is available only in cooling and
heating units. (see "Getting to Know Your Split
In case of electrical power failure, turn off your Split Console &
Underceiling Unit immediately and turn it on again only 1 minute
after electrical power returns. This precaution will prevent the
tension oscillations which may burn the compressor.
8
3
By turning the TEMPERATURE knob you can perform the desired
TEMPERATURE SETTING, positioning it at the desired temperature between
18 and 30°C.
3 By setting the FAN switch you can select the desired FAN SPEED.
4
The AIR VERTICAL DIRECTION CONTROL is done manually, by
moving the deflector up and down.
9
8
By pressing the POWER button you can turn your
1
Split Console & Underceiling Unit on and off on
the wireless remote control. When you turn on the
Getting to know the
equipment the display will show all previous
settings. On turning off the equipment, all
wireless remote control
settings will disappear but the CURRENT TIME.
The START TIME and STOP TIME will also remain
if the TIMER mode is on.
8
10
On HEAT mode the equipment brings the temperature up to the temperature
you have set, between 18 and 30°C. Use the buttons to select
COOL what you consider to be the optimum temperature. The HEAT option is
available only in cooling and heating units. (see "Getting to Know Your Split
Console & Underceiling Unit").
On DRY (dehumidifier) mode, the electronic controller lowers the fan speed of
the whole unit to minimum levels with the outdoor unit working at full power,
FAN
thus enabling the removal of humidity from the room with minimum
temperature change. Use the buttons to set the temperature to a
comfortable range. On this mode, the fan information disappears from the
display.
3 On these buttons you can perform the desired TEMPERATURE
SETTING, between 18 and 30°C on the remote control display.
4
By pressing the FAN button you can select the desired FAN SPEED on the
display.
Bear in mind that on the AUTOMATIC FAN SPEED mode, the fan speed will be
selected by the unit's electronic controller, seeking to meet your needs, based
on the desired TEMPERATURE SETTING.
8
11
5 By pressing the SWEEP button you can perform AIR VERTICAL DIRECTION CONTROL. The
deflector moves constantly so as to distribute the air evenly in the entire room. To set the
deflector to a fixed position or release it for the automatic motion, just press the SWEEP
button. When you turn off the equipment, the deflector will remain in the last position.
MOVING
RANGE
8
12
5 The CLOCK button sets the CURRENT TIME on the display. After it is pressed,
the digits on the display will start flashing. Press the HOUR and MIN buttons to
perform the settings. When you are finished, press the CLOCK button again to
confirm the new settings.
7 The START button sets the START TIME on the TIMER, indicating to the
electronic controller the scheduled time for the unit to start. After pressing it,
the digits on the display will be flashing. Press the HOUR and MIN buttons to
perform the settings. When you are finished, press START again to confirm the
new settings. If you wish to undo the settings, press the button again so that the
information will disappear from the display.
8 The STOP button sets the STOP TIME, indicating to the electronic controller
the scheduled time for the unit to stop. After pressing it, the digits on the
display will be flashing. Press the HOUR and MIN buttons to perform the
settings. When you are finished, press STOP again to confirm the new settings.
If you wish to undo the settings, press the button again so that the information
will disappear from the display.
When the TIMER mode is on, the respective LED will turn on on indoor unit
front panel.
9
By pressing the HOUR and MIN buttons you can set hour and minutes
respectively for the START TIME and STOP on the TIMER and CURRENT TIME.
For the TIMER's START TIME and STOP TIME the minutes will be set for every
10 minutes.
8
13
Emergency Mode
- on turning on
- on turning off
- on switching modes
- on confirming start/stop timer schedule
14
Other information on the liquid crystal display
As explained before, when a mode is selected on the Split Console & Underceiling Unit the
display will show a symbol indicating that the given mode is in effect.
Data transmission between the remote control and the indoor unit will be confirmed if the
display shows and the indoor unit answers with a "BEEP" to the command.
The remote control also indicated when it is time to replace the batteries .
BASIC PROCEDURES
The remote control on the Split Console & Underceiling Unit uses two alkaline AAA 1.5 V
batteries.
Never used old batteries or any other than the recommended ones and keep in mind that
batteries for this purpose last approximately 1 (one) year. Do not replace batteries while the
8
15
Turn off the breaker before starting any cleaning procedure either on the
indoor or outdoor unit.
Cleaning
The frequency of the outdoor unit cleaning must be established
according to the environment where it is installed. and Care
!! Never use detergent or alcohol directly on the plastic parts.
Clean the cabinets with a flannel or soft cloth soaked in warm
water or soap. Do not use steel sponges to clean the units, or
they may be scratched.
The indoor unit has an easily removable filter which retains the impurities
of the atmosphere.
We recommend that the filter be cleaned every 15 days. In places where
the impurity rate is rather high, the cleaning should be carried out weekly.
To remove the filter, proceed as demonstrated on the right.
Clean it with a vacuum cleaner or wash it with warm water and soap.
Bear in mind that an obstructed air filter causes lower performance and
higher energy consumption.
Do not use your equipment with no air filter, or the impurities will gather
in the coils.
Call an authorized company once a year to clean the coils.
8
16
Troubleshooting OCCURRENCE POSSIBLE CAUSES SOLUTIONS
?
guide Equipment shut-off
1)Circuit breaker turned off.
2)Power cord unplugged.
1)Turn on the circuit breaker.
2)Connect the power cord into
the wall outlet.
Before calling the authorized
1) Clean the air filter.
company for technical assistance, 1) Dirty air filter.
2) Remove the obstructions
see how to proceed when your AIR 2) Air flow obstruction
3) Open room. (curtains, sofas,etc.).
SPLIT presents any of the 3) Close the open windows and
4) Thermostat knob not
symptoms described below. Equipment not well placed. doors.
cooling/heating 5) Equipment was not 4) Adjust the thermostat correctly
room satisfactorily. according to the instructions of
measured appropriately to
the room. this manual.
6) Presence of some heat 5) Define again the appropriate
source in the room model for the room.
6) Eliminate the heat source from
! atmosphere (cooling).
the room.
17
8
18
Índice ¡Felicitaciones
Conociendo su
Split Console &
Underceiling
3
por su
Nosotros de la United Technologies Carrier estamos muy satisfechos por tenerle
como usuario de un Split Console & Underceiling.
Nosotros podemos afirmar que usted adquirió un equipo de alta tecnología, bajo
Instalación
Precauciones
5
6
elección!
consumo de energía y gran durabilidad.
Para obtener el mejor desempeño del equipo, es fundamental seguir
correctamente las instrucciones contenidas en este manual.
Acompáñenos hasta la última página y pase a comprender mejor por qué
Recomendaciones
7 invertimos tanto en nuevas tecnologías.
Importantes
Conociendo el
Control Remoto 9
Con Cable
Conociendo el
Control Remoto 13
Inalámbrico
Limpieza y
Conservación
17 ¡En fin usted es el enfoque de toda nuestra atención!
Soluciones Prácticas 18
19
UNIDAD INTERNA
Conociendo su Split Console
y U nderceiling
Painel de
CONTROL
CONTROL
INTERNA
UNIDAD
AxAxP
CABLE
PESO
NETO
(mm)
CON
(kg)
42LSA12226 CL CW 1000 X 635 X 265 / 275 16,5
Control remoto
42LSA18226 CL CW 1000 X 635 X 265 / 275 22,0
42LSA24226 CL CW 1380 X 635 X 265 / 275 28,5
Tuberías y cables de 42LSA30226 CL CW 1380 X 635 X 265 / 275 28,5
interconexión 42LSA36226 CL CW 1760 X 635 X 265 / 275 39,5
(no suministradas) 42LSA42226 CL CW 1760 X 635 X 265 / 275 39,5
42LSA48226 CL CW 1760 X 635 X 265 / 275 39,5
42LSA60226 CL CW 2140 X 635 X 265 / 275 47,0
Tomada de aire
UNIDAD
EXTERNA
Operación (*)
Velocidades
Capacidad
Corriente (A)
(V - Ph - Hz)
Flujo de aire
Tensión (V)
Interruptor
de circuito
(BTU/h)
Nominal
(m³/h)
(A)
Descarga
de aire
Dreno 12000 208/230 - 1 - 60/50 0,60 10 680 3 C/HP
18000 208/230 - 1 - 60/50 0,70 15 800 3 C/HP
OPCIÓN 1 24000 208/230 - 1 - 60/50 0,83 15 1.100 3 C/HP
30000 208/230 - 1 - 60/50 0,79 20 1.400 3 C/HP
36000 208/230 - 1 - 60/50 1,50 30 1.650 3 C/HP
42000 208/230 - 1 - 60/50 1,70 25 1.650 3 C/HP
48000 208/230 - 1 - 60/50 1,70 25 2.150 3 C/HP
60000 208/230 - 1 - 60/50 1,70 25 2.200 3 C/HP
OPCIÓN 2
OPCIÓN 4
OPCIÓN 3 20
Los acondicionadores de aire, como el SPLIT CONSOLE & Instalación
UNDERCEILING, necesitan una instalación más especializada debido
a la necesidad de completarse a través de tubos de cobre, conexiones
eléctricas, etc. Tales artículos no son suministrados con las unidades
interna o externa porque varían sus cantidades y dimensiones de
acuerdo al perfil del lugar de instalación.
Para operase con éxito y seguridad, nos otros manteniemos una red de
empresas registradas, entrenadas en la fábrica para proporcionarle a
usted, usuario, la tranquilidad de quien contrata a un instalador
respetable técnicamente.
Le indicamos que pida un presupuesto de instalación (componentes
de la interconexión y mano de obra) solamente con empresas
especializadas en aire acondicionado.
21
¡Precauciones! ! Use el equipo solamente en el voltaje indicado en la etiqueta.
22
Mantenga libre las tomadas o descargas de aire de las unidades
¡Recomendaciones
interna o externa. Su obstrucción ocasiona reducción en el
rendimiento y puede provocar daños al equipo. !
Asegúrese siempre de que el ajuste de temperatura del
Importantes!
termostato esté coherente con el nivel de comodidad de los
ocupantes.
23
8
Si la energía es interrumpida, apague inmediatamente su SPLIT CONSOLE
& UNDERCEILING y vuelva a encenderlo solamente después del
restablecimiento. Ese procedimiento evitará las variaciones de tensión
que pueden quemar el compresor.
24
8
1
Presionando la tecla ON/OFF usted
ENCIENDE/APAGA su SPLIT CONSOLE &
UNDERCEILING a través del control remoto con
Conociendo el Control
2
cable.
Remoto con cable
Colocando en posición la tecla MODE usted opta
por la OPERACIÓN DESEADA.
ENFRIAMIENTO
En la operación ENFRIAMIENTO el equipo,
cuando está funcionando, reduce la temperatura
del ambiente hasta la temperatura que usted
estableció, entre 18 y 30°C. Gire la perilla
TEMPERATURE para colocar la temperatura en
ENFRIAMIENTO &
CALENTAMIENTO
la faja que usted considere ideal. En la
operación VENTILACIÓN, apenas el ventilador
en la unidad interna está en funcionamiento,
circulando el aire ambiente. En esta opción
usted no mantiene control sobre la temperatura
del ambiente. En la operación
CALENTAMIENTO, el equipo, cuando está
funcionando, aumenta la temperatura del
ambiente hasta la temperatura establecida por
usted, entre 18 y 30°C. Gire la perilla
TEMPERATURE para colocar la temperatura en
la faja que usted considere ideal. La opción
CALENTAMIENTO solamente está disponible en
unidades que operan en enfriamiento &
calentamiento (ver Conociendo su SPLIT
8
25
3
26
8
1 Presionando la tecla POWER usted ENCIENDE/APAGA
su SPLIT CONSOLE & UNDERCEILING a través del
control remoto inalámbrico. Al encender el equipo
Conociendo el Control
aparecerá en el display la totalidad de las informaciones
contenidas en la programación anterior. Lo mismo, al
Remoto Inalámbrico
apagar el equipo, desaparecerá restando apenas la hora
actual. LA HORA INICIO y HORA FIN de la función TIMER
estarán presentes solamente si las mismas están
activadas.
FAN
Indica la operación VENTILACIÓN, donde apenas el
ventilador en la unidad interna está en funcionamiento,
circulando el aire ambiente. En esta operación la
información de temperatura desaparece del display.
8
27
En la operación CALENTAMIENTO, el equipo, cuando está
funcionando, aumenta la temperatura del ambiente hasta la temperatura
COOL establecida por usted, entre 18 y 30°C. Utilice las teclas para
colocar la temperatura en la faja que usted considere ideal. La opción
CALENTAMIENTO solamente está disponible en unidades que operan en
enfriamiento & calentamiento (ver Conociendo su SPLIT CONSOLE
& U N D E R C E I L I N G ) .
En la operación DESHUMEDIFICACIÓN el controlador electrónico baja
FAN la velocidad de ventilación de la unidad entera a niveles mínimos con la unidad
externa en pleno funcionamiento, posibilitando la retirada de humedad en el
ambiente acondicionado con mínima alteración de temperatura. Utilice las
teclas para colocar la temperatura en la faja que usted considere
ideal. En esta operación la información de la ventilación desaparece del display.
28
8
5 Presionando la tecla SWEEP usted ejecuta el CONTROL VERTICAL DEL FLUJO DE AIRE. El
deflector se mueve constantemente para poder distribuir el aire por todo el ambiente
acondicionado. Para fijar el deflector en una posición específica o liberar el mismo para
movimiento automático, basta presionar la tecla SWEEP. Al apagar el equipo el deflector
quedará en la última posición asumida.
Banda de
movimentación
29
8
5
La tecla CLOCK tiene por finalidad ajustar en el display el HORARIO ACTUAL. Después
de presionar la misma, los dígitos en el visor estarán intermitentes. Presione las teclas
POWER y MIN para realizar el ajuste. Terminado el mismo presione la tecla CLOCK
nuevamente para confirmar la nueva programación.
7
La tecla START tiene por finalidad iniciar la función HORA INICIO del TIMER indicando
al controlador electrónico el horario programado para el inicio del funcionamiento de
la unidad. Después de presionar la misma, los dígitos en el visor estarán intermitentes.
Presione las teclas POWER y MIN para realizar el ajuste. Terminado el mismo presione
la tecla START nuevamente para confirmar la nueva información. En el caso de que
desee desprogramar, presione nuevamente la tecla para que la información
desaparezca del display.
8
La tecla STOP tiene por finalidad iniciar la función HORA FIN del TIMER indicando al
controlador electrónico el horario programado para el inicio del funcionamiento de la
unidad. Después de presionar la misma, los dígitos en el visor estarán intermitentes.
Presione las teclas POWER y MIN para realizar el ajuste. Terminado el mismo presione
la tecla STOP nuevamente para confirmar la nueva programación. En el caso de que
desee desprogramar, presione nuevamente la tecla para que la información
desaparezca del display.
Cuando la función TIMER esté activada en el panel frontal de la unidad interna se
encenderá el LED correspondiente al símbolo *.
9
Presionando las teclas POWER y MIN usted realiza el ajuste de la hora u de los minutos,
respectivamente para la función HORA INICIO y FIN del TIMER y HORARIO ACTUAL.
Para el ajuste de la HORA INICIO del TIMER y HORA FIN del TIMER, los minutos
30
8
Modo Emergencia
Como ya fue visto en los puntos anteriores, al seleccionar una función el control remoto del SPLIT CONSOLE & UNDERCEILING presentará en
el display un símbolo indicando que la referida función está en ejecución.
La transmisión de datos entre el control remoto y la unidad interna estará confirmada si en el display aparece * y si la unidad interna responde
con un BIP al comando propuesto.
El control remoto también indica cuándo hay que cambiar las pilas .
PROCEDIMENTOS BÁSICOS
32
8
Antes de empezar cualquier procedimiento de limpieza de la unidad
interna o externa, desconecte el enchufe.
Lim pieza y
La limpieza externa de la unidad debe obedecer a una periodicidad de
acuerdo con el tipo del ambiente donde el equipo está instalado. Conservación
!!
¡Nunca aplique detergente o alcohol directamente sobre las
piezas plásticas. Limpie los gabinetes con una franela o tela
suave empapada en agua tibia y jabón neutro! No use esponjas
de acero en las limpiezas de las unidades pues pueden
arañarlas.
8
33
16
Soluciones ?
PROBLEMAS POSIBLES CAUSAS SOLUCIONES
prácticas
1)interruptor de circuito 1)encienda nuevamente el
El equipo no funciona. apagado. interruptor.
2)cable de alimentación 2)conecte el cable de
desenchufado. alimentación en el enchufe.
¡ Si el problema continúa y
! no puede ser solucionado
Pérdida de agua para
dentro del ambiente
acondicionado.
1)dreno tapado.
2)instalación incorrecta.
1)desobstruya el dreno.
2)corrija la instalación
de acuerdo con las
orientaciones indicadas,
1)pilas descargadas. 1)sustituya las.
desenchufe el equipo y no Control Remoto 2)control remoto dañado. 2)use el modo emergencia hasta
vuelva a enchufarlo. no funciona sustituyr el control dañado.
Después, llame a la
empresa autorizada que
prefiera, para ayudarlo.
34
18
16
8
P.D.: The information contained in the guide may be modified at any time without notice.
P.D.: La información contenida en este manual puede ser modificada en cualquier momento sin previa notificación.
Av. Guilherme Schell, 10100 - Phone (00-55-51) 477-2244 - Fax (00-55-51) 477-9413 - ZIP 92420-000 - Canoas - Brazil.