Download as pdf
Download as pdf
You are on page 1of 3
‘ACB ‘Consists of breaker body ©) and draw-out cradle), nals @, contol ci rminals G9, auxiliary switches 4), Draw-out eradle and position switches @. ‘Conse the ON-OFF mesa, he closing col tering dvi, nd ovreent Breaker bo boty release @. OFF bation Push to open the ACD, - ON button Push to close the ACB. = (ON-OFF indieaior Shows “OFF when the ACB is open and “ON when aa eae Shows "CHARGED" wen hein ingarcagel an "DISCHARGED a Charging handle mp to charge dhe coing speings Position indicator Indicates the presen breaker body poston: CONN, TEST, or ISOLATED. Grip Hold to draw out he breaker body Dey Insert the draw-out hand nt this hole to move the breaker body Release button Pash o move the breaker body Fom the TEST positon parser “Aecommedates upto three paocs to Tock the breaker body i he CONN., TEST or P ISOLATED posion, Padlocks arent supplied. Use padlock with a6 mm-dimeter lever (optional) oa Tockcin OFF pate adlocking tis plate allows the ACB tobe Tocked inthe open (OFF sate. (Padlocks are (cptionat) ot supplied, Use padlocks with a6 mmiameier shackle.) Provides protection against inadvertent buon operaion and ean be palocked. (Padiocks ON-OFF button cover are not supplied, Use padlocks witha 6 mm-diamter shackle.) Upto three padlocks canbe installed ON-OFF eyele Reads th number of ON-OFF oles: Tt coun a series of aperations fom close oops a counter (optional) one eye. See adler King is plate prevent stings oF overcurrent release @ tobe inadvertently betel changed. (Padlocks are not supplied. Use padlocks with a 6: mm-diameter shackle.) ‘This otecive deve is supplied power vie te power CT installed inthe ACB mais aera cult When the eurent sensor detects an overcurrent inthe main circuit, he OCR (OCR) instructs the magnet hold trigger (MH) to trip open the ACB Front cover “Aplastic cover ofthe breaker body front panel Teceats the type, applicable standards and ated breaking capacity of the ACB. Rating nameplate Tndicates the numberof poles, operation method, accessories, and serial number ofthe ACB. ‘Allows breaker body @) to be moved on draw-out rail ©. ‘Closes when the breaker body isin the CONN. position. (Closes wien the breaker body isin the CONN. or TEST positon are chambers ae fied pe Extinguishes the are that occurs in the breaking operation. Two eee ceaeets pole. See 6-2-2. "Arc chambers", ‘Eonvers the current in the main circu info a voltage signal in proportion to the magnitude (Current sensor of the current and sends the signal fo overcurrent release @. ® j@8| ® |e\a\e| © |ele| @|o| © |e\e|@ \a\e| © |o || © |@| © |6| © |e\O/o| © Jo\q\e) © | © [A ‘Mold cover ‘A plastic cover of the breaker body side face. ‘Mold base ‘A plastic eoverof the breaker body rear face. 5 ‘Allows the breaker body to be locked in the CONN. position even the ACB is subject to + aks Sxce O ‘Vibrations. Standard equipped on ACBS that conform to ship classiication society (ed) (optional) Song vation Standard equiped ACB that to ship y Draw-out ral ‘Use to draw oul the breaker body from the draw-out cradle. Draw-out rail end ‘Refer to chapter | “Operation Precautions”. Body stopper Refer to chapter 1 “Operation Precautions”. Prevents the breaker body from falling when the body is drawn out from the draw-out Hook pin ome Body stopper shaft ‘Refer to chapier I “Operation Precautions”. Rail stopper red) ‘Aifows the draw-out rail o be locked in the drawn-out or retracted stat, 5 a dicate the present breaker body position: CONN,, TEST, ISOLATED or INSERTED. The scree guiaaes position switches are available in 2C or 4C configuration. Connections to the position (one ‘switches are made through Md screws, KRB-5377¢ ae 7 mirol ci ne through Ma screw terminals Fg 1 shows the cont sean ene i teri Fig, 1 Control circuit terminals -Iiion switches, the eonirol eeu terminals and the auxiliary switches from ——genrarterminad == Protects the pos 5 @ _dlock cover (optional) damage. c gsc ‘Socues th con emninal block over Cover tving sewew 7 Sas the sate ofthe ACD (ON or OFF). The axilian switches are avaiable in 4C tothe i -Ausiliany switehes eat guration (standard), or 7C or 10C configuration (opina), Connect ® —copionsh softehes are made through Md serew erminals Tenia lock se Honaches contol cul rola and onan veh a Sno Ground terminal MS ‘Allows connection of a ground ‘terminal, a pes daca Ts abr a ii ion we @ Govexhast port ions te AC. 0g gl opal fo ae wes ACE © Arcgss tai aan @ Ling hole (020m) @ Cover fxing sere Position padlock lever @ Release buton ae ‘Drav-out handle insertion hole Position switches © ‘Control circuit terminal Control circuit eontact © y switches Main circuit contact & Boy stoppet @ Hook pin @ Body stopper sha @ Rail stopper Breaker fixing bolt (ed) @ Draw-out rail O— 19 Draw-out rail end © Protrusion @ Specification nameplate O— @ Draw-out era (front view) & Cont cit contet @ Mold cover @ Mold tase a © Sesion amet M0 oii Me as! zs > O Breaker body roller Are chamber Gas exhaust port S creat sesor © ‘Main eircutterninal @— @ dawout cradle (er view) © Breaker body (ear view) Fig. 14 Gener view and parts designation a KRB-5377¢

You might also like