Drop Hammer 1800 kg

Description Symbol Value Unit Remarks Reff Equation


WELD CALCULATION

Weld Strength p/(t x L) eq.1


Sy/SF eq.2

P = Force kg
t = welding height mm
L = weldinglength mm
Sy = yield strength, kg/m2
SF = safety Factor
=
Weld thickness H = 18 mm
= 0.018 m
=
weld height t = 12.73 mm eq.3 t=0,0707 x h
= 0,01 m
=
Electrode number = E7018
Sy = 50 ksi
Sy = 345 Mpa
Sy = 35,180,209.35 kg/m2
=
Safety Factor SF = 3 Unitless
=
Allowable stresses = 11,726,736.45 eq.2 Sy/SF

Transverse Load P = 1800 KG

From wq.1. we got L = P/(t x )


L = 0.01535 M