WALL ANGLE

3000x24x24x0.4
LxWxHxT

MAIN T
3600x24x32x0.3 Ceiling Light
LxWxHxT

CEILING LIGHT
200X200
CROSS T
1200x24x25x0.3
LxWxHxT
Gypsum Board
1200x1800

CROSS T
600X24X25X0.3
LxWxHxT

GYPSUM BOARD GYPSUM BOARD RCP POP RCP


595x595

GRID CEILING PLAN Perimeter


Perimeter
Channel
Channel
25x25x20x0.5
25x25x20x0.5
LxHxWxT
LxHxWxT

Ceiling Section
75x25x0.9
GRID CEILING SECTION LxHxT
A Ceiling Section
75x25x0.9
Main Ts are suspended by suspension system and carry the weight of LxHxT
the Grid system. These Ts have a system of interlocking with each
other in order to provide an additional length and thus form a
continuous mesh across the space where they are used.
Main T
They have following features Intermediate Channel Intermediate
Hanger holes
50x15x0.5 Channel
Slots to interlock Cross T LxHxT 50x15x0.5
Cross T
LxHxT

Cross Ts are used intermittently at the specified distances and are


inter locked with the Main Ts. Typically the Cross Ts are of 2 sizes:
1200 mm and 600 mm. They thus form modules which makes a Mesh
mesh/grid.
Cross T
Isometric
Scale 1:4
GYPSUM BOARD CEILING PLAN POP FALSE CEILING PLAN

GYPSUM BOARD CEILING SECTION POP FALSE CEILING SECTION A


Rawl plug
45x8
LxD Rawl plug
After the framing mesh if fixed below the frame with metal screws
45x8 A Rawl plug and after that pop is applied on the mesh to make the surface
Soffit cleat Connecting clips are used to connect LxD 45x8 smooth.
27x37x25x1.6 the intermediate and ceiling section channel When the pop dries the cut outs are made for the ceiling lights and
LxD fan
LxSxWxt Soffit cleat
27x37x25x1.6 Soffit cleat
Metal Screws are used to connect
Connecting clips Level Clip the gypsum board to the ceiling section LxSxWxt 27x37x25x1.6
D-4 CEILING SECTION LxSxWxt
False ceiling light Ceiling light connected Hanger Channel SCALE: 1:2 Hanger Channel
connected through a clip above Detail - A through clips 20x25 20x25
Cove light
SCALE: 1:4 LxW LxW